Rudd RGTJ-07EMAES User Manual

FORM NO. G11-464 REV. 7
Supersedes Form No. G11-464 Rev. 6
GAS FURNACES
Annual Fuel Utilization Efficiency -
AFUE
THIS MODEL
97%78%
HIGH
MID
82% 88%
92.0%
RGTJ- SERIES
Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kW]
(All Models 90% A.F.U.E.† or Above)
CLASSIC®90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES
The Rheem®Classic®90 High Efficiency line of downflow/ horizontal gas furnaces are designed for utility rooms, clos­ets, alcoves, attics or crawl spaces. The RGTJ is shipped in the downflow configuration and is easily converted for hori­zontal left-hand airflow applications.
The design is certified by CSA.
Features
Low profile “34 inch” design is lighter and easier to handle
and leaves room for optional accessories.
Top electrical connections, left or right gas and conden-
sate drainage connections on downflow models.
Condensate drain for horizontal application provided
standard.
Integrated control board manages all operational functions
and provides hookups for an electronic air cleaner.
A slow-opening gas valve and a specially designed
inducer system make it one of the quietest furnaces on the market today.
Galvanized steel cabinet.
Optional indoor or outdoor combustion air.
Control board diagnostics.
A variety of cooling coils and plenums designed to use with the Classic 90 gas furnaces are available as optional acces­sories for air conditioning models.
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
of Energy test procedures.
2 Rheem Manufacturing Company
STANDARD EQUIPMENT
Completely assembled and wired; heat exchanger; primary: 409 stainless steel, secondary: 29-4C stainless steel; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut-off valve; 100% safety lock out; cool fan off delay; field selectable heat fan off delay; one hour automatic retry; self-test diagnostics; control diagnostics; electronic air cleaner connections; pressure regulator for natural and L.P. (propane) gases; transformer; direct drive, multi-speed blower motor. (Please note: a thermostat is not included as standard equipment.)
OPTIONAL EQUIPMENT
(See Accessory Page)
All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
90 HIGH EFFICIENCY DOWNFLOW/HORIZONTAL GAS FURNACE
PRIMARY AND SECONDARY HEAT EXCHANGER
REMOTE SENSOR
HOT SURFACE IGNITOR
IN-SHOT BURNERS
PRESSURE SWITCH
DRAFT INDUCER
INTEGRATED FURNACE CONTROL
GAS VALVE AND MANIFOLD
Rheem Manufacturing Company 3
GENERAL TERMS OF LIMITED WARRANTY
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS DOWNFLOW/HORIZONTAL MODELS
U.S. and Canadian Models
NOTES: All models are 115V, 60HZ, 1
ø.
Gas connection size for all models is
1
/2
" [13 mm] N.P.T.
See Conversion Kit Index Form for high altitude derate.Canadian installations only.In accordance with D.O.E. test procedures.
MODEL IDENTIFICATION
Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy.
Primary and Secondary Heat Exchanger ...Twenty (20) Years
*Any Other Part.............................................Five (5) Years
*This five year limited warranty is applicable only to single-phase prod-
ucts installed in residential applications on or after January 1, 2001.
RG T J
07E AMES
Rheem Gas
Furnace
Downflow/
Horizontal
Condensing
Gas Furnace
Design
Series
Heating Input
Designation
Variations
A = Std. B = Wide
Cabinet
Blower Size
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
Z = 12 x 11
[305 x 279 mm]
Y = 12 x 7
[305 x 178 mm]
Heat/Cool
Designation
E = 1100-1300 CFM
[519-613.5 L/s]
G = 1500-1700 CFM
[707.9-802.3 L/s]
J = 1900-2100 CFM
[896.7-991.1 L/s]
Fuel Code
S = U.S. and
Canadian Natural Gas
Hot Surface
Ignition
04E 06E 07E 09E 10E 12E
Input
BTU/HR
45,000 [13 kW] 60,000 [17.6 kW] 75,000 [20.5 kW]
90,000 [26.4 kW] 105,000 [30.7 kW] 120,000 [35.2 kW]
[ ] Designates Metric Conversions
MODEL NUMBERS RGTJ- SERIES
INPUT-BTU/HR [kW]
HEATING CAPACITY BTU/HR [kW]
HIGH ALTITUDE INPUT [kW]
HIGH ALTITUDE OUTPUT CAPACITY [kW]
BLOWER (D x W) [mm]
MOTOR H.P. [W] SPEEDS-TYPE
MOTOR FULL LOAD AMPS 6.8 6.8 6.8 8.0 9.5 8.0 8.0 9.5 8.0
HEATING SPEED Med-Low Low Med Med Low Med Med Low Med
COOLING SPEED High High High High High High High High High
HEAT EXT. STATIC PRESSURE (IN. W.C.) [kPA]
RATED EXT. STATIC PRESSURE (IN. W.C.) [kPA]
HEATING C.F.M. @ .2" W.C. E.S.P. [L/s]
COOLING C.F.M. @ .5" W.C. E.S.P. [L/s]
TEMPERATURE RISE RANGE °F [°C]
STANDARD FILTER [mm]
APPROX. SHIPPING WEIGHT (LBS.) [kG]
AFUE
CALIFORNIA SEASONAL EFFICIENCY
04EMAES 06EMAES 07EMAES 07EYBES 07EYBGS 09EZAGS 10EZAGS 10EZAJS 12ERAGS
45,000 [13.19]
42,000 [12.31]
40,500 [11.87]
37,800 [11.07]
11 x 7
[279 x 178]
1/2 [373]
4-PSC
.10 [.025] .12 [.029] .12 [.029] .12 [.029] .12 [.029] .15 [.037] .20 [.049] .20 [.049] .20 [.049]
.50 [.12] .50 [.12] .50 [.12] .50 [.12] .50 [.12] .50 [.12] .50 [.12] .50 [.12] .50 [.12]
890 [420] 885 [418] 1060 [500] 1275 [602] 1275 [602] 1400 [661] 1425 [673] 1425 [673] 1565 [739]
1220 [576] 1180 [557] 1150 [543] 1370 [647] 1625 [767] 1570 [740] 1560 [736] 1820 [859] 1700 [802]
30-60
[16.7-33.3]
(2) 12" x 20"
[305 x 508]
111 [50.3] 117 [53.1] 123 [55.8] 123 [55.8] 123 [55.8] 148 [67.1] 152 [68.9] 152 [68.9] 160 [72.6]
92.0% 92.4% 92.0% 92.3% 92.3% 92.4% 92.0% 92.0% 92.1%
84.35% 86.46% 89.96% 85.00% 85.00% 86.40% 87.02% 87.02% 87.37%86.40%
60,000 [17.58]
56,000 [16.41]
54,000 [15.83]
50,400 [14.77]
11 x 7
[279 x 178]
1/2 [373]
3-PSC
40-70
[22.2-38.9]
(2) 12" x 20"
[305 x 508]
75,000 [21.98]
70,000 [20.51]
67,500 [19.78]
63,000 [18.46]
11 x 7
[279 x 178]
1/2 [373]
3-PSC
45-75
[25-41.7]
(2) 12" x 20"
[305 x 508]
75,000 [21.98]
70,000 [20.51]
67,500 [19.78]
63,000 [18.46]
12 x 7
[305 x 178]
1/2 [373]
3-PSC
35-65
[19.4-36.1]
(2) 12" x 20"
[305 x 508]
75,000 [21.98]
70,000 [20.51]
67,500 [19.78]
63,000 [18.46]
12 x 7
[305 x 178]
3/4 [559]
3-PSC
35-65
[19.4-36.1]
(2) 12" x 20"
[305 x 508]
90,000 [26.37]
84,000 [24.61]
81,000 [23.73]
76,000 [22.27]
12 x 11
[305 x 279]
1/2 [373]
3-PSC
35-65
[19.4-36.1]
(2) 12" x 20"
[305 x 508]
09EZAJS
90,000 [26.37]
84,000 [24.61]
81,000 [23.73]
76,000 [22.27]
12 x 11
[305 x 279]
3/4 [559]
3-PSC
9.5
Low
High
.15 [.037]
.50 [.12]
1400 [661]
1850 [873]
35-65
[19.4-36.1]
(2) 12" x 20"
[305 x 508]
148 [67.1]
92.4%
105,000
[30.77]
97,000 [28.43]
94,500 [27.70]
87,500 [25.64]
12 x 11
[305 x 279]
1/2 [373]
3-PSC
50-80
[27.8-44.4]
(2) 12" x 20"
[305 x 508]
105,000
[30.77]
97,000 [28.43]
94,500 [27.70]
87,500 [25.64]
12 x 11
[305 x 279]
3/4 [559]
3-PSC
50-80
[27.8-44.4]
(2) 12" x 20"
[305 x 508]
[279 x 254]
1/2 [373]
[27.8-44.4]
(2) 14" x 20"
[609 x 508]
120,000
[35.17]
113,000
[33.12]
108,000
[31.65]
100,000
[29.31]
11 x 10
3-PSC
50-80
12ERAJS
120,000
[35.17]
113,000
[33.12]
108,000
[31.65]
100,000
[29.31]
11 x 10
[279 x 254]
3/4 [559]
3-PSC
9.5
Low
High
.20 [.049]
.50 [.12]
1565 [739]
2040 [963]
50-80
[27.8-44.4]
(2) 14" x 20"
[609 x 508]
160 [72.6]
92.1%
87.37%
Loading...