FORM NO. G11-507
Supersedes Form No. G11-507
GAS FURNACES
CLASSIC®SERIES
SUPER QUIET 80
™
80.0% A.F.U.E.
✝
UPFLOW/HORIZONTAL
GAS FURNACES
w/ECM MOTOR
The Rheem Classic®Series Super Quiet 80™line of upflow/horizontal
gas furnaces are designed for utility rooms, closets, alcoves, or attics.
Because of the Super Quiet 80’s low-profile 34 inch [864 mm]
height, the upflow model can also be used to satisfy most applications that traditionally call for a horizontal furnace.
The design is certified by CSA International.
Features
■ Innovative combustion design results in reliable, efficient
operation at sound levels which provide distinct competitive
advantage.
■ Patented Heat Exchanger, constructed of both stainless and
aluminized steel for the maximum in corrosion resistance.
■ Low profile “34 inch” design is lighter and easier to handle, and
leaves room for optional equipment.
■ Convertible from upflow to horizontal left or right without field
conversion.
■ Left or right side gas and electric inlet connections with quick,
simple change.
■ Robust and reliable direct spark ignition utilizing remote sense and
an integrated board with humidifier and electronic air cleaner
hookups.
■ Insulated blower compartment helps to reduce jacket loss and
noise.
■ Pre-paint galvanized steel cabinet.
■ Molded permanent filter.
■ Grab-holes in doors to aid in easy door removal and replacement.
■ ECM X-13 Blower Motor.
A variety of cooling coils and plenums designed to use with Rheem
Classic
®
Series Super Quiet 80™gas furnaces are available as
optional accessories.
These furnaces can be installed in an upflow position or laid on either
side in a horizontal position. Field conversion not required.
✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy
test procedures.
RGPT- SERIES
Models with Input Rates from
50,000 to 125,000 BTU/HR
[15 to 37 kW]
(U.S. & Canadian Models)
ENER UIDE
Annual Fuel Utilization Efficiency -
THIS MODEL
80.0%
MID
82% 88%
HIGH
AFUE
97%78%
2 Rheem Heating, Cooling and Water Heating
CLASSIC®SERIES SUPER QUIET 80
™
UPFLOW/HORIZONTAL GAS FURNACE
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
The complete terms of limited and other warranties are available at our
sales office, or through local installer.
All models can be converted by a qualified Rheem distributor or local service
dealer to use L.P. (propane) gas without changing burners. Factory approved
kits must be used to convert from natural to L.P. (propane) gas and may be
ordered as optional accessories from a Rheem parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
Direct Spark Ignitor
Remote Sensor
X-13 Motor
In-Shot Burners
Gas Valve
Draft Inducer Motor
Integrated
Furnace
Control
Heat Exchanger
STANDARD EQUIPMENT
Completely assembled and wired; induced draft blower; pressure switch;
redundant main gas control; blower compartment door safety switch; solid
state time on/time off blower control; limit control; manual shut-off valve,
pressure regulator for natural and L.P. (propane) gas; transformer; direct drive
multi-speed blower with Regal Beloit X-13 Motor. Furnaces are equipped with
cooling/heating relay and transformer (40VA) ready for air conditioning
applications. (Please note: a thermostat is not included as standard
equipment.) Flame sensor diagnostics; on-board twinning options; fusedprotection (secondary), 3rd speed fan option for continuous fan; common
heat/cool terminal.
OPTIONAL EQUIPMENT
Side filter frame assembly. Return air cabinet for all sizes.
NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
Rheem Heating, Cooling and Water Heating 3
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS
U.S. AND CANADA MODELS (UPFLOW/HORIZONTAL)
MODEL IDENTIFICATION—UPFLOW MODELS
NOTES: All models are 115V, 60HZ, Single Phase. Gas connection size for all models is 1/2" [12.7 mm] N.P.T.
➀ In accordance with D.O.E. test procedures.
➁ See Conversion Kit Index Form for high altitude derate in U.S. applications. For Canadian applications, reference the furnace installation instructions.
*
Data references Canadian applications only.
[ ] Designates Metric Conversions
MODEL NUMBERS
RGPT- SERIES
Input
in BTU's/Hr [kW] ➁
Heating Capacity
in BTU's/Hr [kW] ➀
High Altitude Input
in BTU's/Hr [kW]*
High Altitude Output Capacity
in BTU's/Hr [kW]*
Heat Ext. Static Pressure
in "wc [kPa]
Blower (D x W) in inches [mm]
Motor H.P.-Speeds Type [W]
Motor Full Load Amps 8.4 6.8
Heating Speed (factory setting) MED-LOW MED
Cooling Speed (factory setting) HIGH HIGH
Cooling in CFM [L/s] @ 0.5"wc
[0.12 kPa] E.S.P. (nominal)
Rated E.S.P.
in "wc [kPa]
Temperature Rise Range
in °F [°C]
Max Outlet Air
in °F [°C]
Standard Filter Dimensions
in inches [mm]
Approx. Shipping Weight
in Lbs. [kg]
Return Air Cabinets (Opt.)
RXGR-?? Filter Size
in inches [mm]
AFUE - Electronic Ignition Modules ➀
05EBMKR
05NBMKR
50,000
[15]
41,000
[12]
45,000
[13]
36,500
[11]
0.1
[0.025]
11 x 7
[279 x 178]
3/4hp, 5spd,
X-13 [559]
1600
[775]
0.5
[0.12]
25-55
[13.9-30.6]
155
[68.3]
15-3/4 x 25
[400 x 635]
105
[48]
C17B
(2) 12 x 16
[305 x 406]
80.0% 80.0%
[279 x 178]
1/2hp, 5spd,
X-13 [373]
[19.4-36.1]
15-3/4 x 25
[400 x 635]
(2) 12 x 16
[305 x 406]
07EAMKR
07NAMKR
75,000
[22]
60,000
[18]
67,500
[20]
53,500
[16]
0.12
[0.029]
11 x 7
1200
[566]
0.5
[0.12]
35-65
165
[73.8]
105
[48]
C17B
07EBRQR
07NBRQR
75,000
[22]
60,000
[18]
67,500
[20]
53,500
[16]
0.12
[0.029]
11 x 10
[279 x 254]
1hp, 5spd,
X-13 [746]
10.9 10.9 10.9
MED-LOW MED-HIGH MED-HIGH
HIGH HIGH HIGH
2000
[944]
0.5
[0.12]
25-55
[13.9-30.6]
165
[73.8]
19-1/4 x 25
[489 x 635]
120
[54]
C21B
(2) 20 x 16
[508 x 406]
80.0% 80.0% 80.0%
10EBRMR
10NBRMR
100,000
[29]
81,000
[24]
90,000
[26]
72,500
[21]
0.15
[0.037]
11 x 10
[279 x 254]
1hp, 5spd,
X-13 [746]
2000
[944]
0.5
[0.12]
30-60
[17-33]
190
[87.7]
19-1/4 x 25
[489 x 635]
120
[54]
C21B
(2) 20 x 16
[508 x 406]
12EARMR
12NARMR
125,000
[37]
99,000
[29]
112,500
[33]
89,000
[26.1]
0.2
[0.05]
11 x 10
[279 x 254]
1hp, 5spd,
X-13 [746]
2000
[944]
0.5
[0.12]
35-65
[19.4-36.1]
180
[82.2]
22-3/4 x 25
[578 x 635]
140
[63]
C24B
(2) 24 x 16
[610 x 406]
R G P T 07E A M K R
Rheem Gas Upflow/ Design Heating Input Designation Variations Blower Heating & Cooling Fuel Type
Furnace Horizontal Series
–
Electric
Ignition
05E
07E
10E
12E
NO
Model
05N
07N
10N
12N
x
50,000 [15 kW]
75,000 [22 kW]
100,000 [29 kW]
125,000 [37 kW]
Input
BTU/HR
A = Std.
Cabinet
B = Wide
Cabinet
Designation Designation R = Natural Gas,
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
K = 600-1200 CFM
[283 x 566 L/s]
Q = 1000-1600 CFM
[472 x 755 L/s]
M = 1200-2000 CFM
[566 x 944 L/s]
U.S. and
Canadian
Standard
Furnace