Rudd RGPR-07EBRQR User Manual

FORM NO. G11-489 REV. 1
Supersedes Form No. G11-489
GAS FURNACES
SUPER QUIET 80
TWO STAGE UPFLOW/HORIZONTAL GAS FURNACES
The Rheem Prestige Series®Super Quiet 80 Two Stage line of upflow/horizontal gas furnaces are designed for util­ity rooms, closets, alcoves, or attics. Because of the Pres-
tige’s low-profile 34 inch [864 mm] height, the upflow model installed vertically can also be used to satisfy most applications that traditionally call for a horizontal furnace.
The design is certified by CSA International.
Features
Patented Heat Exchanger, constructed of both stainless
and aluminized steel for the maximum in corrosion resis­tance.
Low profile “34 inch” [864 mm] design is lighter and eas-
ier to handle, and leaves room for optional equipment.
Energy efficient and quiet ECM 2+ motor.
Improves cooling efficiency when matched with rated
condensing unit and coil.
Constant CFM.
Dip switch settings for selectable cooling airflow.
On-demand dehumidification terminal for improved com-
fort in cooling mode.
Convertible from upflow to horizontal left or right.
Left or right side gas and electric inlet connections.
All models equipped with flame sensor feature, an inte-
grated board with humidifier and electronic air cleaner hookups.
Insulated blower compartment, a slow-open gas valve, a
specially designed draft inducer motor and blower motor make it one of the quietest furnaces on the market today.
Pre-paint galvanized steel cabinet.
Molded permanent filter.
Easy door removal and replacement.
Compatible with single or two-stage thermostat. (For opti-
mal performance, two-stage thermostat recommended.) A variety of cooling coils and plenums designed to use with Rheem Prestige Series
®
Super Quiet 80 Two Stage gas fur-
naces are available as optional accessories.
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
of Energy test procedures.
RGPR- SERIES
ECM Equipped Models with Input Rates from 50,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single Phase [15 to 37 kW] (U.S. & Canadian Models)
ENER UIDE
Annual Fuel Utilization Efficiency -
THIS MODEL
80.0%
MID
82% 88%
HIGH
AFUE
2 Rheem Manufacturing Company
Direct Spark Ignitor
Flame Sensor
In-Shot Burners
Pressure Switch
IFC Integrated Furnace Control
ECM Interface Furnace Control
Heat Exchanger
Two-Speed Draft Inducer Motor
ECM Motor
The complete terms of limited and other warranties are available at our sales office, or through local installer.
All models can be converted by a qualified HVAC professional or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheem parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
STANDARD EQUIPMENT
Completely assembled and wired; 2 speed draft inducer; high and low pressure switches; redundant 2 stage main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; transformer; ECM blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; fused protection (secondary).
RHEEM PRESTIGE SERIES SUPER QUIET 80 TWO STAGE UPFLOW/HORIZONTAL GAS FURNACE
Rheem Manufacturing Company 3Rheem Manufacturing Company 3
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS (UPFLOW) U.S. AND CANADA MODELS
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy.
Gas Heat Exchanger Limited Warranty ......Twenty (20) Years
*Any Other Part.............................................Five (5) Years
*This five year limited warranty is applicable only to single-phase
products installed in residential applications on or after January 1, 2001.
MODEL IDENTIFICATION—UPFLOW MODELS
[ ] Designates Metric Conversions
In accordance with D.O.E. test procedures.See Conversion Kit Index Form for high altitude derate.
G P R
Furnace
A M K R
Rheem Gas Upflow/ Design Heating Input Designation
Horizontal Series
Variations Blower Heating & Cooling Fuel Type
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
K = 600-1200 CFM
[283-566 L/s]
M = 1200-2000 CFM
[566-944 L/s]
Q = 1000-1600 CFM
[566-944 L/s]
Electric
Ignition
05E 07E 10E 12E
A = Std.
Cabinet
B = Wide
Cabinet
Designation Designation R = Natural Gas,
U.S. and Canadian Standard Furnace
Input
BTU/HR
50,000 [15 kW]
75,000 [22 kW] 100,000 [29 kW] 125,000 [37 kW]
NO
x
Model
05N 07N 10N 12N
278
Option Code
for High Altitude,
(available on
certain models)
R 07E
MODEL NUMBERS RGPR- SERIES
100% High Input–BTU/Hr [kW] High Heating Capacity–BTU/Hr [kW] 70% Low Input–BTU/Hr [kW] Low Heating Capacity–BTU/Hr [kW] Heating–Ext. Static Pressure [kPa]
Blower (D x W) [mm]
ECM Motor H.P. [W] Motor Full Load Amps. Unit Amps Maximum Overcurrent Protection Heating Speed CFM–High Fire [L/s] Heating Speed CFM–Low Fire [L/s] Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s] Max. E.S.P. (In. W.C.) [kPa] Temperature Rise Range
°F [°C] Max. Outlet Air Temp. °F [°C] Standard Filter Size–Inches
[mm] Approx. Shipping Weight (Lbs.) [kg] Return Air Cabinets
(Opt.) RXGR­Filter Size [mm]
AFUE
High Input Low Input
05EBMKR 05NBMKR
50,000 [15] 75,000 [22] 100,000 [29] 125,000 [37] 40,000 [12] 60,000 [18] 80,000 [23] 100,000 [29] 35,000 [10] 52,500 [15] 70,000 [20] 87,500 [25] 28,000 [8] 42,000 [12] 56,000 [16] 70,000 [20]
.10 [.025] .15 [.037] .20 [.05] .20 [.05]
11 x 7
[279 x 178]
3
/4 [559]
9.6 7.7 12.8 12.8
8.7 8.7 12.0 12.0 15 15 15 15
850 [401] 1176 [555] 1600 [753] 1832 [865] 625 [295] 980 [462] 1300 [615] 1420 [670]
1200 [566]
0.8 [.2] 0.8 [.2] 0.8 [.2] 0.8 [.2] 25-55 [13.9-30.6] 30-60 [17-33] 30-60 [17-33] 35-65 [19.4-36.1] 20-50 [11.1-27.8]
155 [68.3] 153/4 x 25
[400 x 635]
110 [50] 115 [52] 120 [54] 140 [63]
C17B
(2) 12 x 16
[305 x 406]
80% 80% 80% 80%
07EAMKR 07NAMKR
11 x 7
[279 x 178]
1
/2 [373]
1200 [566]
20-50 [11.1-27.8] 25-55 [13.9-30.6] 30-60 [17-33]20-50 [11.1-27.8]
165 [73.8] 170 [76.6] 180 [82.2] 153/4 x 25
[400 x 635]
C17B
(2) 12 x 16
[305 x 406]
07EBRQR 07NBRQR
75,000 [22] 60,000 [18] 52,500 [15] 42,000 [12]
.15 [.037]
11 x 10
[279 x 254]
3
/4 [559]
9.6
12.0 15
1305 [616] 1125 [533]
1600 [755]
0.8 [.2]
25-55 [13.9-30.6]
165 [73.8]
191/4 x 25
[489 x 635]
115 [52]
C21B
(2) 20 x 16
[508 x 406]
80%
10EBRMR 10NBRMR
11 x 10
[279 x 254]
1 [746] 1 [746]
2000 [944]
191/4 x 25
[489 x 635]
C21B
(2) 20 x 16
[508 x 406]
12EARMR 12NARMR
[279 x 254]
223/4 x 25
[578 x 635]
(2) 24 x 16
[610 x 406]
11 x 10
2000 [944]
C24B
4 Rheem Manufacturing Company
NOTES: May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
May be 0" [0 mm] with type B vent.May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes.
[ ] Designates Metric Conversions
UPFLOW DIMENSIONS
UPFLOW DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm]
MODEL
RGPR-
05, 07A 171/2 [445] 1611/32 [415] 123/8 [314] 07B, 10 211/2 [533] 1927/32 [504] 141/8 [359]
12
A B C D E
241/2 [622] 2311/32 [593] 157/8 [403]
F
LEFT
SIDE
151/2 [381] 0
181/2 [470] 0 0 0 1 [25] 3 [76]
221/2 [559]
21/2 [64] 21/2 [64] 21/2 [64]
3 [76]
0 0 0 1 [25] 3 [76]
REDUCED CLEARANCES (IN.) [mm]
RIGHT
SIDE
BACK TOP FRONT VENT
0 1 [25] 3 [76]
6 [152] 6 [152] 6 [152]
SHIP. WGTS.
(LBS.) [Kg]
105 [47.6]
120 [54.4] 140 [63.5]
Rheem Manufacturing Company 5
NOTES: May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
May be 0" [0 mm] with type B vent.May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes.
[ ] Designates Metric Conversions
HORIZONTAL DIMENSIONS
HORIZONTAL DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm]
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED FOR INSTALLATION
ON ITS BACK, WITH ACCESS DOORS
FACING UPWARDS.
NOTE: In horizontal configuration, return air cutout is not permitted.
MODEL
RGPR-
05, 07A 07B, 10
12
A B C D E
171/2 [445] 1611/32 [415] 123/8 [314] 21 [533] 1927/32 [504] 141/8 [359] 241/2 [622] 2311/32 [593] 157/8 [403]
15 [381] 181/2 [470] 22 [559]
F
21/2 [64] 21/2 [64] 21/2 [64]
LEFT SIDE
0
3 [76] 0 0 0 1 [25] 3 [76] 0 0 0 1 [25] 3 [76]
REDUCED CLEARANCES (IN.) [mm]
RIGHT
SIDE
BACK TOP FRONT VENT
0 1 [25] 3 [76]
6 [152] 6 [152] 6 [152]
SHIP. WGTS.
(LBS.) [Kg]
110 [49.9] 120 [54.4]
140 [63.5]
6 Rheem Manufacturing Company
BLOWER PERFORMANCE DATA—UPFLOW/HORIZONTAL MODELS
Note: See Coil Specification Sheet for coil data.
[ ] Designates Metric Conversions
MODEL RGPR-
BLOWER SIZE
INCHES [mm]
05
07A
07B
10, 12
(D X W)
11 x 7
[279 x 178]
11 x 7
[279 x 178]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
ECM
MOTOR H.P.
[W]
3/4
[559]
1/2
[373]
3/4
[559]
1
[746]
BLOWER
SPEED
HIGH
MED-HI
MED LOW
HIGH
MED-HI
MED LOW
HIGH
MED-HI
MED LOW
HIGH
MED-HI
MED LOW
CFM [L/s] AIR DELIVERY
EXTERNAL STATIC PRESSURE
INCHES WATER COLUMN [kPa]
.1 [.025]–.8 [.2]
1200 [566] 1000 [472]
800 [378] 600 [283]
1200 [566] 1000 [472]
800 [378] 600 [283]
1600 [755] 1400 [661] 1200 [566] 1000 [472]
2000 [944] 1600 [755] 1400 [661] 1200 [566]
Rheem Manufacturing Company 7
†Filter racks are shipped without filters. Filters shipped with furnace may be used or a suitable 1” [25.4 mm] filter. *Designates “E” or “N”.
THE RXGR-C24B MUST ONLY BE INSTALLED ON THE SIDE OPPOSITE THE GAS AND ELECTRICAL CONNECTIONS.
WARNING: IMPORTANT NOTICE
A SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THE FURNACE IS INSTALLED WITH SIDE AIR RETURN DUCTS. FAILURE TO INSTALL A BASE PLATE COULD CAUSE PRODUCTS OF COMBUSTION TO BE CIRCULATED INTO THE LIVING SPACE AND CREATE POTENTIALLY HAZARDOUS CONDITIONS.
FURNACE BASE
WIDTH
SOLID BOTTOM BASE
PLATE SIZE
IN. [mm]
KIT NO. PLATE NO.
IN. [mm]
17
1
/2 [445] RXGB-D17 AE-61874-02 151/8 x 239/16 [384 x 598]
21
1
/2 [533] RXGB-D21 AE-61874-03 185/8 x 239/16 [473 x 598]
24
1
/2 [622] RXGB-D24 AE-61874-04 255/8 x 239/16 [651 x 598]
RXGW-B01 CHIMNEY ADAPTER
See Installation Instructions for application limitations.
FOR HIGH ALTITUDES:
HIGH ALTITUDE OPTION CODE: U.S. & Canada – 278 HIGH ALTITUDE KIT: RXGY-F13 (for all models) NOTE: High altitude kits and options do NOT include additional
burner orifices. If a burner orifice change is necessary, they must be ordered through PROSTOCK
®.
. See Installation
instructions for more information.
Option — 278 furnaces are shipped with #51 DMS orifices installed. This is one drill size smaller than standard furnaces to account for expected average elevations and heating values typically seen in these areas.
CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines
when converting furnaces for high altitudes.
For all installations above 2000 ft. (including all option — 278 models), the burner orifice size needs to be recalculated and verified. A burner orifice change may still be required. See Installation Instructions for more information.
NOTE: For Canadian installations only, an optional derate (manifold
gas pressure reduction) method may be used to adjust the furnace for altitude. See Installation Instructions for more information. This optional method may NOT be used for U.S. installations.
(U.S. Models—Kit packaged with furnace.
Requires field installation).
[ ] Designates Metric Conversions
INTERNAL FILTER RACK FOR BOTTOM OR SIDE RETURN: RXGF-DA*
*Filters available through PROSTOCK
®
.
SIDE RETURN FILTER RACK: RXGF-CA BOTTOM RETURN FILTER RACK FOR
UPFLOW APPLICATION: RXGF-CB
ACCESSORY RETURN AIR CABINETS
Return Air Cabinets may be installed on either side application except RXGR-C24B (side application must be on side opposite gas and electrical connections).
RXPF-F01 and F02
FOSSIL FUEL KIT—is for use with Rheem Heat Pumps and
Super Quiet 80 warm air furnaces. RXPF-F02 also meets TVA requirements.
ACCESSORIES—UPFLOW
FILTER RACK FILTER SIZES† INCHES [mm]
MODEL
RGPR-
05, 07*AMK
07*BRQ, 10
12
RXGF-CA
(SIDE)
153/4 x 25
[400 x 635]
153/4 x 25
[400 x 635]
153/4 x 25
[400 x 635]
RETURN AIR CABINETS
RXGR-C17B 171/2 [445] (2) 12 x 16 [305 x 406] RXGR-C21B RXGR-C24B 241/2 [622] (2) 24 x 16 [610 x 406]
A
IN. [mm]
211/4 [533]
FILTER SIZE
IN. [mm]
(2) 20 x 16 [508 x 406]
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
RHEEM AIR CONDITIONING DIVISION
5600 Old Greenwood Road, Fort Smith, Arkansas 72908
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A. 8-07 DC FORM NO. G11-489 REV. 1
Supersedes Form No. G11-489