FORM NO. G11-492 REV. 2
Supersedes Form No. G11-492 Rev. 1
SUPER QUIET 80
™
(A.F.U.E.✝)TWO STAGE
UPFLOW/HORIZONTAL
GAS FURNACES
The Rheem Classic®Plus Super Quiet 80™2-Stage line of
upflow/horizontal gas furnaces are designed for utility
rooms, closets, alcoves, or attics. Because of the low-
profile 34 inch [864 mm] height, the upflow model can
also be used to satisfy most applications that traditionally call for a horizontal furnace.
The design is certified by CSA International.
Features
■ Patented heat exchanger, constructed of both stainless
and aluminized steel for the maximum in corrosion
resistance.
■ Low profile “34 inch” design is lighter and easier to han-
dle, and leaves room for optional equipment.
■ Convertible from upflow to horizontal left or right without
field conversion.
■ Left or right side gas and electric inlet connections with
quick, simple change.
■ Direct spark ignition models equipped with remote sense
and feature an integrated board with humidifier and electronic air cleaner hookups.
■ Insulated blower compartment, a two stage gas valve and
a specially designed two speed draft inducer motor make
it one of the quietest furnaces on the market today.
■ Pre-paint galvanized steel cabinet.
■ Molded permanent filter.
■ Grab-holes in doors to aid in easy door removal and
replacement.
■ Compatible with single or two-stage thermostat. (For opti-
mal performance two-stage thermostat recommended.)
A variety of cooling coils and plenums designed to use with
Rheem Classic
®
Plus Super Quiet 80™2-Stage gas fur-
naces are available as optional accessories.
Furnaces can be installed in an upflow position or laid on
either side in a horizontal position. Field conversion not
required.
✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
of Energy test procedures.
RGPQ- SERIES
Models with Input Rates from
50,000 to 150,000 BTU/HR
[15 to 44 kW]
(U.S. & Canadian Models)
GAS FURNACES
ENER UIDE
Annual Fuel Utilization Efficiency -
THIS MODEL
80.0%
MID
82% 88%
HIGH
AFUE
97%78%
2 Rheem Heating, Cooling and Water Heating
The complete terms of limited and other warranties are available at our
sales office, or through local installer.
All models can be converted by a qualified local service professional to use L.P.
(propane) gas without changing burners. Factory approved kits must be used
to convert from natural to L.P. (propane) gas and may be ordered as optional
accessories.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
RHEEM CLASSIC®PLUS SUPER QUIET 80
™
TWO STAGE
UPFLOW/HORIZONTAL GAS FURNACE
Direct Spark Ignitor
In-Shot Burners
Integrated
Furnace Control
Heat Exchanger
STANDARD EQUIPMENT
Completely assembled and wired; 2 speed draft inducer; high and low pressure
switches; redundant 2 stage main gas control; blower compartment door safety
switch; solid state time on/time off blower control; limit control; transformer;
direct drive multi-speed blower motor. Furnaces are equipped with cooling/
heating relay and transformer (40VA) ready for air conditioning applications.
(Please note: a thermostat is not included as standard equipment.) Flame
sensor diagnostics; Twinning options; fused-protection (secondary).
OPTIONAL EQUIPMENT
Side filter frame assembly. Return air cabinet for all sizes.
NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
Remote Sensor
Two-Speed Draft
Inducer Motor
Rheem Heating, Cooling and Water Heating 3
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS
U.S. AND CANADA MODELS (UPFLOW)
MODEL IDENTIFICATION—UPFLOW MODELS
NOTES: All models are 115V, 60HZ, 1Ø. Gas connection size for all models is 1/2" [12.7 mm] N.P.T.
➀
In accordance with D.O.E. test procedures.
➁
See Conversion Kit Index Form for high altitude derate in U.S. applications. For Canadian applications, reference the furnace installation instructions.
[ ] Designates Metric Conversions
R G P Q
—
07E A M E R
Rheem Gas Upflow/ Horizontal Heating Input Designation Variations Blower Heating & Cooling Fuel Type
Furnace
Horizontal
Series
Electric
Ignition
05E
07E
10E
12E
15E
NOx
Models
05N
07N
10N
12N
15N
Input
BTU/HR
50,000 [15 kW]
75,000 [22 kW]
100,000 [29 kW]
125,000 [37 kW]
150,000 [44 kW]
A = Std.
Cabinet
B = Wide
Cabinet
Designation
Designation
R = Natural Gas,
U.S. and
Canadian
Standard
Furnace
U = 11 x 6
[279 x 152 mm]
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
E = 1100-1300 CFM
[519-614 L/s]
J = 1900-2100 CFM
[897-991 L/s]
G = 1500-1700 CFM
[708-802 L/s]
MODEL NUMBERS
RGPQ- SERIES
High Inpu
Heating Capa
Low Input–BTU/Hr [kW] 35,000 [10] 52,500 [15]
Heating Capacity–BTU/Hr [kW] 28,000 [8] 41,600 [12]
Heating–Ext. Static Pressure [kPa] .10 [.025] .12 [.029] .12 [.029] .15 [.037] .15 [.037] .20 [.05] .20 [.05]
Blower (D x W) [mm]
Motor H.P.–[W]
Speeds–Type
Motor Full Load Amps 7.1 7.1
Heating Speed–High Fire MED-LOW MED-HIGH
Heating Speed–Low Fire LOW MED-LOW LOW LOW LOW LOW LOW
Cooling Speed HIGH HIGH
Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s]
Max. E.S.P. (In. W.C.) [kPa] 0.5 [.12] 0.5 [.12]
Temperature Rise Range °F
High Input [°C]
Temperature Rise Range °F
Low Input [°C]
Max. Outlet Air Temp. °F
[°C]
Standard Filter–In.
[mm]
Approx. Shipping Weight (Lbs.)
[kg]
Return Air Cabinets (Opt.) RXGR-
Filter Size–In.
[mm]
AFUE ➀
t–BTU–B
city–BTU
TU/Hr [kW] ➁
/Hr [kW] ➀
05EAUER
05NAUER
50,000 [15] 75,000 [22]
40,900 [12] 61,280 [18]
11 x 6
[279 x 152]
1
/2 [373]
4-PSC
1200
[566]
25-55
[13.9-30.6]
20-50
[11.1-27.8]
155
[68.3]
153/4 x 25
[400 x 635]
85
[39]
C14B
(2) 12 x 16
[305 x 406]
80.0% 80.0%
07EAMER
07NAMER
11 x 7
[279 x 178]
1
/2 [373]
4-PSC
1200
[566]
30-60
[16.7-33.3]
25-55
[13.9-30.6]
165
[73.9]
153/4 x 25
[400 x 635]
105
[48]
C17B
(2) 12 x 16
[305 x 406]
07EAMGR
07NAMGR
75,000 [22] 100,000 [29] 100,000 [29] 125,000 [37]
61,410 [18] 81,470 [23] 81,340 [23] 101,660 [29]
52,500 [15] 70,000 [20] 70,000 [20] 87,500 [25]
41,600 [12] 56,000 [16] 56,000 [16] 70,080 [20]
11 x 7
[279 x 178]
3
/4 [559]
4-PSC
9.5 7.1 9.5 9.5
MED-LOW MED-HIGH MED-HIGH MED-HIGH
MED-HIGH HIGH HIGH HIGH
1600
[755]
0.5 [.12] 0.5 [.12] 0.5 [.12] 0.5 [.12]
25-55
[13.9-30.6]
15-45
[8.3-25.0]
155
[68.3]
153/4 x 25
[400 x 635]
105
[48]
C17B
(2) 12 x 16
[305 x 406]
80.0% 80.0% 80.0% 80.0%
10EAMER
10NAMER
11 x 7
[279 x 178]
1
/2 [373]
4-PSC
1200
[566]
45-75
[25-41.7]
35-65
[19.4-36.1]
190
[87.7]
153/4 x 25
[400 x 635]
115
[52]
C17B
(2) 12 x 16
[305 x 406]
10EBRJR
10NBRJR
11 x 10
[279 x 254]
3
/4 [559]
4-PSC
2000
[944]
30-60
[16.7-33.3]
25-55
[13.9-30.6]
170
[76.6]
191/4 x 25
[489 x 635]
120
[54]
C21B
(2) 20 x 16
[508 x 406]
12EARJR
12NARJR
11 x 10
[279 x 254]
3
/4 [559]
4-PSC
2000
[944]
35-65
[19.4-36.1]
30-60
[16.7-33.3]
180
[82.2]
223/4 x 25
[578 x 635]
140
[63]
C24B
(2) 24 x 16
[610 x 406]
15EARJR
15NARJR
150,000 [44]
121,920 [35]
105,000 [30]
84,000 [24]
11 x 10
[279 x 254]
3
/4 [559]
4-PSC
9.5
MED-HIGH
HIGH
2000
[944]
0.5 [.12]
50-80
[27.8-44.4]
40-70
[22.2-38.9]
190
[87.7]
223/4 x 25
[578 x 635]
150
[68]
C24B
(2) 24 x 16
[610 x 406]
80.0%