FORM NO. G11-485 REV. 6
Supersedes Form No. G11-485 Rev. 5
GAS FURNACES
CLASSIC SERIES
®
SUPER QUIET 80
80.0% A.F.U.E.
✝
UPFLOW/
HORIZONTAL
GAS FURNACES
The Rheem Classic Series®Super Quiet 80 line of upflow/horizontal gas furnaces are designed for utility rooms, closets,
alcoves, or attics. Because of the Super Quiet 80’s low-profile
34 inch [864 mm] height, the upflow model can also be used
to satisfy most applications that traditionally call for a horizontal furnace.
The design is certified by CSA International.
Features
■ Innovative combustion design results in reliable, efficient
operation at sound levels which provide distinct competitive
advantage.
■ Patented Heat Exchanger, constructed of both stainless and
aluminized steel for the maximum in corrosion resistance.
■ Low profile “34 inch” design is lighter and easier to handle,
and leaves room for optional equipment.
■ Convertible from upflow to horizontal left or right without field
conversion.
■ Left or right side gas and electric inlet connections with quick,
simple change.
■ Robust and reliable direct spark ignition utilizing remote
sense and an integrated board with humidifier and electronic
air cleaner hookups.
■ Insulated blower compartment helps to reduce jacket loss
and noise.
■ Pre-paint galvanized steel cabinet.
■ Molded permanent filter.
■ Grab-holes in doors to aid in easy door removal and
replacement.
A variety of cooling coils and plenums designed to use with
Rheem Classic Series
®
Super Quiet 80 gas furnaces are available as optional accessories.
These furnaces can be installed in an upflow position or laid on
either side in a horizontal position. Field conversion not required.
✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of
Energy test procedures.
RGPN- SERIES
Models with Input Rates from
50,000 to 150,000 BTU/HR
[15 to 44 kW]
(U.S. & Canadian Models)
ENER UIDE
Annual Fuel Utilization Efficiency -
THIS MODEL
80.0%
MID
82% 88%
HIGH
AFUE
97%78%
2 Rheem Manufacturing Company
CLASSIC SERIES SUPER QUIET 80
UPFLOW/HORIZONTAL GAS FURNACE
STANDARD EQUIPMENT
Completely assembled and wired; induced draft blower; pressure switch;
redundant main gas control; blower compartment door safety switch; solid
state time on/time off blower control; limit control; manual shut-off valve,
pressure regulator for natural and L.P. (propane) gas; transformer; direct drive
multi-speed blower motor. Furnaces are equipped with cooling/heating relay and
transformer (40VA) ready for air conditioning applications. (Please note: a
thermostat is not included as standard equipment.) Flame sensor diagnostics;
on-board twinning options; fused-protection (secondary), 3rd speed fan
option for continuous fan; common heat/cool terminal.
OPTIONAL EQUIPMENT
Side filter frame assembly. Return air cabinet for all sizes. (See Page 6)
NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
The complete terms of limited and other warranties are available at our
sales office, or through local installer.
All models can be converted by a qualified Rheem distributor or local service
dealer to use L.P. (propane) gas without changing burners. Factory approved
kits must be used to convert from natural to L.P. (propane) gas and may be
ordered as optional accessories from a Rheem parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
Direct Spark Ignitor
Remote Sensor
In-Shot Burners
Draft Inducer Motor
Integrated
Furnace
Control
Heat Exchanger
Rheem Manufacturing Company 3
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS
U.S. AND CANADA MODELS (UPFLOW/HORIZONTAL)
MODEL IDENTIFICATION—UPFLOW MODELS
NOTES: All models are 115V, 60HZ, 1Ø. Gas connection size for all models is 1/2" [12.7 mm] N.P.T.
➀ In accordance with D.O.E. test procedures.
➁ See Conversion Kit Index Form for high altitude derate in U.S. applications. For Canadian applications, reference the furnace installation instructions.
*
Data references Canadian applications only.
[ ] Designates Metric Conversions
MODEL NUMBERS
RGPN- SERIES
Input-BTU/Hr [kW] ➁
Heating Capacity BTU/Hr [kW] ➀
High Altitude Input [kW]* 45,000 [13] 67,500 [20]
High Altitude Output
Capacity [kW]*
Heat Ext. Static Pressure [kPa] .10 [.025] .12 [.029]
Blower (D x W) [mm]
Motor H.P.–Speeds–
PSC Type [W]
Motor Full Load Amps 6.8 7.1
Heating Speed MED-LOW MED-HIGH
Cooling Speed HIGH HIGH
Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s]
Rated E.S.P. (In. W.C.) [kPa] 0.5 [.12] 0.5 [.12]
Temperature Rise Range °F
[°C]
Max. Outlet Air Temp. °F
[°C]
Standard Filter–In.
[mm]
Approx. Shipping Weight (Lbs.)
[kg]
Return Air Cabinets
(Opt.) RXGRFilter Size [mm]
AFUE–Electric Ignition Models ➀
05EAUER
05NAUER
50,000 [15] 75,000 [22]
41,000 [12] 60,000 [18]
36,500 [11] 53,500 [16]
11 x 6
[279 x 152]
1
/2-4-PSC
[373]
1200
[566]
25-55
[13.9-30.6]
155
[68.3]
153/4 x 25
[400 x 635]
85
[39]
C14B
(2) 12 x 16
[305 x 406]
80.0% 80.0%
07EAMER
07NAMER
11 x 7
[279 x 178]
1
/2-4-PSC
[373]
1200
[566]
35-65
[19.4-36.1]
165
[73.8]
153/4 x 25
[400 x 635]
105
[48]
C17B
(2) 12 x 16
[305 x 406]
07EAMGR
07NAMGR
75,000 [22] 100,000 [29] 100,000 [29] 125,000 [37]
60,000 [18] 80,000 [23.4] 81,000 [23.7] 99,000 [29]
67,500 [20] 90,000 [26] 90,000 [26] 112,500 [33]
54,000 [16] 72,000 [21] 72,500 [21] 89,000 [26.1]
.12 [.029] .15 [.037] .15 [.037] .20 [.05]
11 x 7
[279 x 178]
3
/4-4-PSC
[559]
9.5 7.1 9.5 9.5
MED-LOW MED-HIGH MED-LOW MED-LOW
MED-HIGH HIGH MED-HIGH MED-HIGH
1600
[755]
0.5 [.12] 0.5 [.12] 0.5 [.12] 0.5 [.12]
25-55
[13.9-30.6]
155
[68.3]
153/4 x 25
[400 x 635]
105
[48]
C17B
(2) 12 x 16
[305 x 406]
80.0% 80.0% 80.0% 80.0%
10EAMER
10NAMER
11 x 7
[279 x 178]
1
/2-4-PSC
[373]
1200
[566]
45-75
[25.0-41.7]
190
[87.7]
153/4 x 25
[400 x 635]
115
[52]
C17B
(2) 12 x 16
[305 x 406]
10EBRJR
10NBRJR
11 x 10
[279 x 254]
3
/4-4-PSC
[559]
2000
[944]
40-70
[22.2-38.9]
170
[76.6]
191/4 x 25
[489 x 635]
120
[54]
C21B
(2) 20 x 16
[508 x 406]
12EARJR
12NARJR
11 x 10
[279 x 254]
3
/4-4-PSC
[559]
2000
[944]
35-65
[19.4-36.1]
180
[82.2]
223/4 x 25
[578 x 635]
140
[63]
C24B
(2) 24 x 16
[610 x 406]
15EARJR
15NARJR
150,000 [44]
119,000 [35]
135,000 [39.6]
107,500 [31.5]
.20 [.05]
11 x 10
[279 x 254]
3
/4-4-PSC
[559]
9.5
MED-LOW
MED-HIGH
2000
[944]
0.5 [.12]
50-80
[27.8-44.4]
190
[87.7]
223/4 x 25
[578 x 635]
150
[68]
C24B
(2) 24 x 16
[610 x 406]
80.0%
RG P N
Rheem Gas Upflow/ Design Heating Input Designation Variations Blower Heating & Cooling Fuel Type
Furnace Horizontal Series
—
Electric
Ignition
05E
07E
10E
12E
15E
07E A M E R
NO
Model
05N
07N
10N
12N
15N
x
50,000 [15 kW]
75,000 [22 kW]
100,000 [29 kW]
125,000 [37 kW]
150,000 [44 kW]
Input
BTU/HR
A = Std.
Cabinet
B = Wide
Cabinet
Designation
U = 11 x 6
[279 x 152 mm]
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
Designation
E = 1100-1330 CFM
[519-628 L/s]
G = 1450-1750 CFM
[684-826 L/s]
J = 1800-2075 CFM
[850-979 L/s]
R = Natural Gas,
U.S. and
Canadian
Standard
Furnace