Rudd RGPN-10EBRJR User Manual

FORM NO. G11-485 REV. 6
Supersedes Form No. G11-485 Rev. 5
GAS FURNACES
CLASSIC SERIES
®
SUPER QUIET 80
80.0% A.F.U.E.
The Rheem Classic Series®Super Quiet 80 line of upflow/hori­zontal gas furnaces are designed for utility rooms, closets, alcoves, or attics. Because of the Super Quiet 80’s low-profile
34 inch [864 mm] height, the upflow model can also be used to satisfy most applications that traditionally call for a hori­zontal furnace.
The design is certified by CSA International.
Features
Innovative combustion design results in reliable, efficient
operation at sound levels which provide distinct competitive advantage.
Patented Heat Exchanger, constructed of both stainless and
aluminized steel for the maximum in corrosion resistance.
Low profile “34 inch” design is lighter and easier to handle,
and leaves room for optional equipment.
Convertible from upflow to horizontal left or right without field
conversion.
Left or right side gas and electric inlet connections with quick,
simple change.
Robust and reliable direct spark ignition utilizing remote
sense and an integrated board with humidifier and electronic air cleaner hookups.
Insulated blower compartment helps to reduce jacket loss
and noise.
Pre-paint galvanized steel cabinet.
Molded permanent filter.
Grab-holes in doors to aid in easy door removal and
replacement.
A variety of cooling coils and plenums designed to use with Rheem Classic Series
®
Super Quiet 80 gas furnaces are avail­able as optional accessories. These furnaces can be installed in an upflow position or laid on either side in a horizontal position. Field conversion not required.
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of
Energy test procedures.
RGPN- SERIES
Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kW] (U.S. & Canadian Models)
ENER UIDE
Annual Fuel Utilization Efficiency -
THIS MODEL
80.0%
MID
82% 88%
HIGH
AFUE
97%78%
2 Rheem Manufacturing Company
CLASSIC SERIES SUPER QUIET 80 UPFLOW/HORIZONTAL GAS FURNACE
STANDARD EQUIPMENT
Completely assembled and wired; induced draft blower; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; manual shut-off valve, pressure regulator for natural and L.P. (propane) gas; transformer; direct drive multi-speed blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics;
on-board twinning options; fused-protection (secondary), 3rd speed fan option for continuous fan; common heat/cool terminal.
OPTIONAL EQUIPMENT
Side filter frame assembly. Return air cabinet for all sizes. (See Page 6) NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
The complete terms of limited and other warranties are available at our sales office, or through local installer.
All models can be converted by a qualified Rheem distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheem parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
Direct Spark Ignitor
Remote Sensor
In-Shot Burners
Draft Inducer Motor
Integrated
Furnace
Control
Heat Exchanger
Rheem Manufacturing Company 3
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS U.S. AND CANADA MODELS (UPFLOW/HORIZONTAL)
MODEL IDENTIFICATION—UPFLOW MODELS
NOTES: All models are 115V, 60HZ, 1Ø. Gas connection size for all models is 1/2" [12.7 mm] N.P.T.
In accordance with D.O.E. test procedures.See Conversion Kit Index Form for high altitude derate in U.S. applications. For Canadian applications, reference the furnace installation instructions.
*
Data references Canadian applications only.
[ ] Designates Metric Conversions
MODEL NUMBERS RGPN- SERIES
Input-BTU/Hr [kW] Heating Capacity BTU/Hr [kW] High Altitude Input [kW]* 45,000 [13] 67,500 [20] High Altitude Output
Capacity [kW]* Heat Ext. Static Pressure [kPa] .10 [.025] .12 [.029]
Blower (D x W) [mm]
Motor H.P.–Speeds– PSC Type [W]
Motor Full Load Amps 6.8 7.1 Heating Speed MED-LOW MED-HIGH Cooling Speed HIGH HIGH Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s] Rated E.S.P. (In. W.C.) [kPa] 0.5 [.12] 0.5 [.12] Temperature Rise Range °F
[°C] Max. Outlet Air Temp. °F
[°C] Standard Filter–In.
[mm] Approx. Shipping Weight (Lbs.)
[kg] Return Air Cabinets
(Opt.) RXGR­Filter Size [mm]
AFUE–Electric Ignition Models
05EAUER 05NAUER
50,000 [15] 75,000 [22] 41,000 [12] 60,000 [18]
36,500 [11] 53,500 [16]
11 x 6
[279 x 152]
1
/2-4-PSC
[373]
1200 [566]
25-55
[13.9-30.6]
155
[68.3]
153/4 x 25
[400 x 635]
85
[39]
C14B
(2) 12 x 16
[305 x 406]
80.0% 80.0%
07EAMER 07NAMER
11 x 7
[279 x 178]
1
/2-4-PSC
[373]
1200 [566]
35-65
[19.4-36.1]
165
[73.8]
153/4 x 25
[400 x 635]
105 [48]
C17B
(2) 12 x 16
[305 x 406]
07EAMGR 07NAMGR
75,000 [22] 100,000 [29] 100,000 [29] 125,000 [37] 60,000 [18] 80,000 [23.4] 81,000 [23.7] 99,000 [29] 67,500 [20] 90,000 [26] 90,000 [26] 112,500 [33]
54,000 [16] 72,000 [21] 72,500 [21] 89,000 [26.1]
.12 [.029] .15 [.037] .15 [.037] .20 [.05]
11 x 7
[279 x 178]
3
/4-4-PSC
[559]
9.5 7.1 9.5 9.5
MED-LOW MED-HIGH MED-LOW MED-LOW
MED-HIGH HIGH MED-HIGH MED-HIGH
1600 [755]
0.5 [.12] 0.5 [.12] 0.5 [.12] 0.5 [.12] 25-55
[13.9-30.6]
155
[68.3]
153/4 x 25
[400 x 635]
105 [48]
C17B
(2) 12 x 16
[305 x 406]
80.0% 80.0% 80.0% 80.0%
10EAMER 10NAMER
11 x 7
[279 x 178]
1
/2-4-PSC
[373]
1200 [566]
45-75
[25.0-41.7]
190
[87.7]
153/4 x 25
[400 x 635]
115 [52]
C17B
(2) 12 x 16
[305 x 406]
10EBRJR 10NBRJR
11 x 10
[279 x 254]
3
/4-4-PSC
[559]
2000 [944]
40-70
[22.2-38.9]
170
[76.6]
191/4 x 25
[489 x 635]
120 [54]
C21B
(2) 20 x 16
[508 x 406]
12EARJR 12NARJR
11 x 10
[279 x 254]
3
/4-4-PSC
[559]
2000
[944]
35-65
[19.4-36.1]
180
[82.2]
223/4 x 25
[578 x 635]
140 [63]
C24B
(2) 24 x 16
[610 x 406]
15EARJR 15NARJR
150,000 [44] 119,000 [35]
135,000 [39.6]
107,500 [31.5]
.20 [.05]
11 x 10
[279 x 254]
3
/4-4-PSC
[559]
9.5
MED-LOW
MED-HIGH
2000 [944]
0.5 [.12] 50-80
[27.8-44.4]
190
[87.7]
223/4 x 25
[578 x 635]
150 [68]
C24B
(2) 24 x 16
[610 x 406]
80.0%
RG P N
Rheem Gas Upflow/ Design Heating Input Designation Variations Blower Heating & Cooling Fuel Type
Furnace Horizontal Series
Electric Ignition
05E 07E 10E 12E 15E
07E A M E R
NO
Model
05N 07N 10N 12N 15N
x
50,000 [15 kW]
75,000 [22 kW] 100,000 [29 kW] 125,000 [37 kW] 150,000 [44 kW]
Input
BTU/HR
A = Std.
Cabinet
B = Wide
Cabinet
Designation
U = 11 x 6
[279 x 152 mm]
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
Designation
E = 1100-1330 CFM
[519-628 L/s]
G = 1450-1750 CFM
[684-826 L/s]
J = 1800-2075 CFM
[850-979 L/s]
R = Natural Gas,
U.S. and Canadian Standard Furnace
4 Rheem Manufacturing Company
NOTES: May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
May be 0" [0 mm] with type B vent.May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes.
[ ] Designates Metric Conversions
UPFLOW DIMENSIONS
UPFLOW DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm]
MODEL
RGPN-
05
07 10 (A) 171/2 [445] 1611/32 [415] 123/8 [314] 10 (B)
12 241/2 [622] 2311/32 [593] 157/8 [403]
15
A B C D F
14 [356] 1227/32 [326] 105/8 [270] 171/2 [445] 1611/32 [415] 123/8 [314]
21 [533] 1927/32 [504] 141/8 [359]
241/2 [622] 2311/32 [593] 157/8 [403]
E
111/2 [292] 15 [381] 15 [381] 181/2 [470] 22 [559] 22 [559]
LEFT SIDE
17/8 [48] 21/2 [64] 21/2 [64] 0 21/2 [64] 21/2 [64] 0 0 0 1 [25] 3 [76] 21/2 [64]
0
4 [102]
0
3 [76] 3 [76]
0
0 0 0 1 [25] 3 [76]
REDUCED CLEARANCES (IN.) [mm]
RIGHT
SIDE
BACK TOP FRONT VENT
0 1 [25] 3 [76]
0 1 [25] 3 [76]
0 1 [25] 3 [76]
0
0 1 [25] 3 [76]
6 [152] 6 [152] 6 [152] 6 [152] 6 [152] 6 [152]
SHIP. WGTS.
(LBS.) [kg]
85 [38.6] 105 [47.6] 115 [52.2] 120 [54.4] 140 [63.5] 150 [68]
Rheem Manufacturing Company 5
NOTES: May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
May be 0" [0 mm] with type B vent.May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes.
[ ] Designates Metric Conversions
HORIZONTAL DIMENSIONS
HORIZONTAL DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm]
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED FOR INSTALLATION
ON ITS BACK, WITH ACCESS DOORS
FACING UPWARDS.
MODEL
RGPN-
05 14 [356] 1227/32 [326] 105/8 [270]
07 171/2 [445] 1611/32 [415] 123/8 [314] 10 (A) 171/2 [445] 1611/32 [415] 123/8 [314] 10 (B) 21 [533] 1927/32 [504] 141/8 [359]
12 241/2 [622] 2311/32 [593] 157/8 [403]
15 241/2 [622] 2311/32 [593] 157/8 [403]
A B C D F
E
111/2 [292] 15 [381] 15 [381] 181/2 [470] 22 [559] 22 [559]
13/4 [45] 0 21/2 [63] 0 21/2 [63] 0 21/2 [63] 0 21/2 [63] 0 0 0 1 [25] 3 [76] 21/2 [63] 0 0 0 1 [25] 3 [76]
LEFT
SIDE
4 [102] 3 [76] 3 [76]
REDUCED CLEARANCES (IN.) [mm]
RIGHT
SIDE
BACK TOP FRONT VENT
0 1 [25] 3 [76] 0 1 [25] 3 [76] 0 1 [25] 3 [76]
0
0 1 [25] 3 [76]
6 [152] 6 [152] 6 [152] 6 [152] 6 [152] 6 [152]
SHIP. WGTS.
(LBS.) [kg]
85 [38.6] 105 [47.6] 115 [52.2] 120 [54.4] 140 [63.5] 150 [68]
6 Rheem Manufacturing Company
ACCESSORIES—UPFLOW
† Filter racks are shipped without filters.
Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter.
*Designates “E” or “N”.
RXPF-F01 and F02
FOSSIL FUEL KITS are for use with Rheem Classic Heat Pumps
and Super Quiet 80 warm air furnaces. The RXPF-F02 meets TVA requirements.
ACCESSORY RETURN AIR CABINETS
Return Air Cabinets may be installed on either side application except RXGR-C24B (side application must be on side opposite gas and electrical connections).
THE RXGR-C24B MUST ONLY BE INSTALLED ON THE SIDE OPPOSITE THE GAS AND ELECTRICAL CONNECTIONS.
WARNING: IMPORTANT NOTICE
A SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THE FURNACE IS INSTALLED WITH SIDE AIR RETURN DUCTS. FAILURE TO INSTALL A BASE PLATE COULD CAUSE PRODUCTS OF COMBUSTION TO BE CIRCULATED INTO THE LIVING SPACE AND CREATE POTENTIALLY HAZARDOUS CONDITIONS.
FURNACE BASE
WIDTH
SOLID BOTTOM BASE
PLATE SIZE
IN. [mm]
KIT NO. PLATE NO.
IN. [mm]
14 [356] RXGB-D14 AE-61874-01 11
5
/8 x 239/16 [295 x 598]
17
1
/2 [445] RXGB-D17 AE-61874-02 151/8 x 239/16 [384 x 598]
21 [533] RXGB-D21 AE-61874-03 18
5
/8 x 239/16 [473 x 598]
24
1
/2 [622] RXGB-D24 AE-61874-04 255/8 x 239/16 [651 x 598]
FOR HIGH ALTITUDES:
OPTION CODE FOR HIGH ALTITUDE: U.S. & Canada
None required for high altitudes. HIGH ALTITUDE CONVERSION KITS: U.S. & Canada
None required for high altitudes.
80+ HIGH ALTITUDE INSTRUCTIONS CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines
when converting for high altitudes. High altitude option codes are not required for these models.
However, the burner orifice size needs to be recalculated and verified at elevations above 2000 ft. See Installation Instructions for more information.
NOTE: For Canadian installations only, an optional derate (manifold
gas pressure reduction) method may be used to adjust the furnace for altitude. See Installation Instructions for more information. This optional method may NOT be used for U.S. installations.
[ ] Designates Metric Conversions
EXTERNAL BOTTOM FILTER RACK: RXGF-CB
FILTER RACK FILTER SIZES† INCHES [mm]
MODEL
RGPN-
05, 07, 10*A
10*BRJ
12, 15
RXGF-CA
(SIDE)
153/4 x 25
[400 x 635]
153/4 x 25
[400 x 635]
153/4 x 25
[400 x 635]
RETURN AIR CABINETS
RXGR-C14B 14 [356] (2) 12 x 16 [305 x 406] RXGR-C17B 171/2 [445] (2) 12 x 16 [305 x 406] RXGR-C21B 21 [533] (2) 20 x 16 [508 x 406] RXGR-C24B 241/2 [622] (2) 24 x 16 [610 x 406]
A
IN. [mm]
FILTER SIZE
IN. [mm]
Rheem Manufacturing Company 7
BLOWER PERFORMANCE DATA—UPFLOW/HORIZONTAL MODELS
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy.
Gas Heat Exchanger Limited Warranty .......Twenty (20) Years
*Any Other Part..............................................Five (5) Years
*This five year limited warranty is applicable only to single-phase products
installed in residential applications on or after January 1, 2001.
NOTES: *Not to be used as a heating speed.
Data compiled with factory filters installed. Recommended blower speeds are in bold.
See Form Number C11-206 for MultiFlex®coil data.
[ ] Designates Metric Conversions
MODEL
NUMBER
RGPN-
SERIES
05EAUER 05NAUER
07EAMER 07NAMER
07EAMGR 07NAMGR
*
10EAMER 10NAMR
10EBRJR 10NBRJR
12EARJR 12NARJR
15EARJR 15NARJR
BLOWER
SIZE
[mm]
11 x 6
[279 x 152]
11 x 7
[279 x 178]
11 x 7
[279 x 178]
*
11 x 7
[279 x 178]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
MOTOR
H.P.
[W]
1/2
[373]
1/2
[373]
3/4
[559]
*
1/2
[373]
3/4
[559]
3/4
[559]
3/4
[559]
BLOWER
SPEED
LOW
MED-LO
MED-HI
HIGH LOW
MED-LO
MED-HI
HIGH LOW
MED-LO
MED-HI
HIGH
LOW
MED-LO
MED-HI
HIGH LOW
MED-LO
MED-HI
HIGH LOW
MED-LO
MED-HI
HIGH LOW
MED-LO
MED-HI
HIGH
EXTERNAL STATIC PRESSURE INCHES [kPa] WATER COLUMN
.1 [.02] .2 [.05] .3 [.07] .4 [.10] .5 [.12] .6 [.15] .7 [.17]
675 [319]
950 [448]
1115 [526] 1270 [599]
921 [435]
1093 [563]
1241 [586]
1393 [657] 1245 [588]
1555 [734]
1810 [854] 2050 [967]
925 [437]*
1050 [496]
1220 [576]
1410 [665] 1295 [611]
1645 [776]
2045 [965] 2320 [1095]
1280 [604]
1645 [776]
2050 [967] 2365 [1116]
1270 [599]
1620 [765]
2010 [949] 2340 [1104]
655 [309]
930 [439]
1090 [514] 1250 [590]
897 [423]
1066 [503]
1212 [572]
1359 [642] 1220 [576]
1515 [715]
1755 [828] 1985 [937]
890 [420]*
1040 [491]
1195 [564]
1380 [651] 1275 [602]
1615 [762]
2000 [944] 2260 [1067]
1275 [602]
1635 [772]
2015 [951] 2310 [1090]
1250 [590]
1595 [753]
1985 [937] 2275 [1074]
635 [300]
905 [427]
1070 [505] 1225 [578]
872 [411]
1039 [490]
1183 [558]
1326 [626] 1195 [564]
1475 [696]
1705 [805] 1915 [904]
865 [408]*
1030 [486]
1160 [547]
1345 [635] 1250 [590]
1580 [746]
1955 [923] 2200 [1038]
1265 [597]
1615 [762]
1960 [925] 2250 [1062]
1220 [576]
1570 [741]
1960 [925] 2215 [1045]
CFM [L/s] AIR DELIVERY
610 [288]
880 [415]
1040 [491] 1200 [566]
845 [399}
1008 [476]
1150 [543]
1293 [610] 1165 [550]
1435 [677]
1645 [776] 1845 [871]
835 [394]* 990 [467]
1140 [538]
1300 [614] 1225 [578]
1550 [732]
1905 [899] 2130 [1005]
1245 [588]
1590 [750]
1935 [913] 2185 [1031]
1195 [564]
1545 [729]
1915 [904] 2145 [1012]
1015 [479] 1165 [550]
1118 [528]
1259 [594] 1135 [536]
1395 [658]
1585 [748] 1785 [842]
1105 [522]
1255 [592] 1195 [564]
1510 [713]
1845 [871] 2060 [972]
1215 [573]
1560 [736]
1885 [890] 2115 [998]
1165 [550]
1515 [715]
1850 [873] 2080 [982]
585 [276]
860 [406]
818 [386] 977 [461]
810 [382]* 960 [453]
555 [262]
830 [392]
985 [465]
1130 [533]
795 [375] 941 [444]
1076 [508]
1214 [573] 1105 [522]
1350 [637]
1530 [722] 1715 [809]
775 [366]* 920 [434]
1065 [503]
1205 [569] 1165 [550]
1465 [691]
1785 [842] 1985 [937]
1185 [559]
1520 [717]
1835 [866] 2035 [960]
1135 [536]
1480 [698]
1800 [850] 2010 [949]
520 [245]
800 [378]
945 [446]
1085 [512]
746 [352] 905 [427]
1033 [487]
1169 [552] 1065 [503]
1300 [614]
1470 [694] 1655 [781]
745 [352]* 890 [420]
1020 [481]
1150 [543] 1135 [536]
1425 [673]
1720 [812] 1910 [901]
1145 [540]
1470 [694]
1775 [838] 1950 [920]
1105 [522]
1440 [680]
1730 [816] 1940 [916]
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
RHEEM AIR CONDITIONING DIVISION
5600 Old Greenwood Road, Fort Smith, Arkansas 72908
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A. 8-07 DC FORM NO. G11-485 REV. 6
Supersedes Form No. G11-485 Rev. 5
Loading...