FORM NO. G11-491 REV. 1
Supersedes Form No. G11-491
GAS FURNACES
SUPER QUIET 80
™
(A.F.U.E.✝) TWO STAGE
DOWNFLOW
GAS FURNACES
The Rheem Classic®Plus Super Quiet 80™2-Stage line of
downflow gas furnaces is designed for installation in closets, alcoves, utility rooms, or attics. The design is certified
by CSA International.
Features
■ Patented heat exchanger, constructed of both stainless
and aluminized steel for the maximum in corrosion
resistance.
■ Low profile “34 inch” [864 mm] design is lighter and easier
to handle, and leaves room for optional equipment.
■ Left or right side gas and electric inlet connections with
quick, simple change.
■ Direct spark ignition.
■ Integrated control board with humidifier and electronic air
cleaner hookups.
■ Insulated blower compartment, a two stage gas valve and
a specially designed two speed draft inducer motor make
it one of the quietest furnaces on the market today.
■ Pre-paint galvanized steel cabinet.
■ Grab-holes in doors to aid in easy door removal and
replacement.
■ Compatible with single or two-stage thermostat. (For opti-
mal performance, two-stage thermostat recommended.)
A variety of cooling coils and plenums designed to use with
Rheem Classic
®
Plus Super Quiet 80™2-Stage gas fur-
naces are available as optional accessories.
✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
of Energy test procedures.
RGLQ- SERIES
Models with Input Rates from
50,000 to 150,000 BTU/HR
[15 to 44 kW]
(U.S. & Canadian Models)
Annual Fuel Utilization Efficiency - AFUE
THIS MODEL
97%78%
HIGH
MID
82% 88%
80.0%
ENER UIDE

2 Rheem Heating, Cooling and Water Heating
STANDARD EQUIPMENT
Completely assembled and wired; 2 speed induced draft blower; high and low
pressure switches; 2 stage redundant main gas control; blower compartment
door safety switch; solid state time on/time off blower control; limit control;
transformer; direct drive multi-speed blower motor. Furnaces are equipped
with cooling/heating relay and transformer (40VA) ready for air conditioning
applications. (Please note: a thermostat is not included as standard equipment.)
Flame sensor diagnostics; fused-protection (secondary).
NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
The complete terms of limited and other warranties are available at our
sales office, or through local installer.
All models can be converted by a qualified Rheem professional or local service
dealer to use L.P. (propane) gas without changing burners. Factory approved
kits must be used to convert from natural to L.P. (propane) gas and may be
ordered as optional accessories.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
NOTE: For natural and L.P. (propane) gas models, direct spark ignition is 100%
lockout type.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
Integrated
Furnace Control
Heat Exchanger
In-Shot Burners
Direct Spark Ignitor
CLASSIC®PLUS SUPER QUIET 80
™
TWO STAGE
DOWNFLOW GAS FURNACE
Remote Sensor
Two-Speed Draft
Inducer Motor

Rheem Heating, Cooling and Water Heating 3
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS
U.S. AND CANADA MODELS (DOWNFLOW)
MODEL IDENTIFICATION—DOWNFLOW MODELS
RG L Q
—
07E A M E R
Rheem Gas Downflow Design Heating Input Designation Variations Blower Heating & Cooling Fuel Type
U = 11 x 6
[279 x 152 mm]
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
E = 1100-1330 CFM
[519-628 L/s]
J = 1800-2075 CFM
[850-979 L/s]
Furnace Series
Electric
Ignition
05E
07E
10E
12E
15E
A = Std.
Cabinet
B = Wide
Cabinet
Designation Designation R = Natural Gas,
U.S. and
Canadian
Standard
Furnace
Electric
Ignition–
NO
x
Models
05N
07N
10N
12N
15N
Input
BTU/HR
50,000 [15 kW]
75,000 [22 kW]
100,000 [29 kW]
125,000 [37 kW]
150,000 [44 kW]
[ ] Designates Metric Conversions
NOTES: All models are 115V, 60HZ, 1
Ø
. Gas connection size for all models is
1
/2
" [12.7 mm] N.P.T.
➀
In accordance with D.O.E. test procedures.
➁
See Conversion Kit Index for high altitude derate in U.S. applications. For Canadian applications, reference the furnace installation instructions.
MODEL NUMBERS
RGLQ- SERIES
High Input–BTU–BTU/Hr [kW] ➁
Heating Capacity–BTU/Hr [kW] ➀
Low Input–BTU/Hr [kW] 35,000 [10] 52,500 [15]
Heating Capacity–BTU/Hr [kW] 28,000 [8] 41,600 [12]
Heating–Ext. Static Pressure [kPa] .10 [.025] .12 [.029] .15 [.037] .15 [.037] .20 [.05] .20 [.05]
Blower (D x W) [mm]
Motor H.P.–[W]
Speeds–Type
Motor Full Load Amps 6.8 7.1
Heating Speed–High Fire MED-LOW MED-HIGH
Heating Speed–Low Fire LOW MED-LOW LOW LOW LOW LOW
Cooling Speed HIGH HIGH
Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s]
Max. E.S.P. (In. W.C.) [kPa] 0.5 [.12] 0.5 [.12]
Temperature Rise Range °F [°C]
High Input
Temperature Rise Range °F [°C]
Low Input
Max. Outlet Air Temp. °F
[°C]
Standard Filter–In.
[mm]
Approx. Shipping Weight (Lbs.)
[kg]
AFUE ➀
05EAUER
05NAUER
50,000 [15] 75,000 [22]
40,360 [12] 61,020 [18]
11 x 6
[279 x 152]
1
/2 [373]
4-PSC
1200
[566]
25-55
[13.9-30.6]
20-50
[11.1-27.8]
155
[68.3]
(1) 14 x 20
[356 x 508]
85
[39]
80.0% 80.0%
07EAMER
07NAMER
11 x 7
[279 x 178]
1
/2 [373]
4-PSC
1200
[566]
35-65
[19.4-36.1]
30-60
[16.7-33.0]
165
[78.3]
(2) 12 x 20
[306 x 508]
105
[48]
10EAMER
10NAMER
100,000 [29] 100,000 [29] 125,000 [37]
81,600 [24] 81,040 [24] 101,750 [29]
70,000 [20] 70,000 [20] 87,500 [25]
56,000 [16] 56,000 [16] 70,000 [20]
[279 x 178]
1
/2 [373]
MED-HIGH MED-HIGH MED-HIGH
0.5 [.12] 0.5 [.12] 0.5 [.12]
[25.0-41.7]
[11.1-27.8]
(2) 12 x 20
[306 x 508]
10EBRJR
10NBRJR
11 x 7
4-PSC
7.1 9.5 9.5
HIGH HIGH HIGH
1200
[566]
45-75
20-50
180
[82.2]
115
[52]
80.0% 80.0% 80.0%
11 x 10
[279 x 254]
3
/4 [559]
4-PSC
2000
[944]
30-60
[16.7-33.3]
35-65
[19.4-36.1]
180
[82.2]
(2) 14 x 20
[356 x 508]
120
[54]
12EARJR
12NARJR
11 x 10
[279 x 254]
3
/4 [559]
4-PSC
2000
[944]
35-65
[19.4-36.1]
25-55
[13.9-30.6]
180
[82.2]
(2) 14 x 20
[356 x 508]
140
[63]
15EARJR
15NARJR
150,000 [44]
121,550 [35]
105,000 [30]
84,000 [24]
11 x 10
[279 x 254]
3
/4 [559]
4-PSC
9.5
MED-HIGH
HIGH
2000
[944]
0.5 [.12]
50-80
[27.8-44.4]
30-60
[16.7-33.3]
190
[87.7]
(2) 14 x 20
[356 x 508]
150
[68]
80.0%

4 Rheem Heating, Cooling and Water Heating
NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
➁ May be 0" [0 mm] with type B vent.
➂ May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with
local codes.
[ ] Designates Metric Conversions
DOWNFLOW DIMENSIONS
DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm]
MODEL
RGLQ-
05
07
10 (A) 171/2 [445] 1611/32 [415] 121/8 [308]
10 (B)
12 241/2 [622] 2311/32 [593] 155/8 [397]
15
A B C D E
14 [356] 1227/32 [326] 103/8 [264]
171/2 [445] 1611/32 [415] 121/8 [308]
21 [533] 1927/32 [504] 137/8 [352]
241/2 [622] 2311/32 [593] 155/8 [397]
LEFT
SIDE
➀
131/8 [333]
➀
165/8 [422]
➀
165/8 [422] 0
➀
201/8 [511]
➀
235/8 [600] 0 0 0 1 [25] 3 [76]
➀
235/8 [600]
RIGHT
SIDE
0
4 [102]
0
3 [76]
3 [76] ➁
0
0 0 0 1 [25] 3 [76]
REDUCED CLEARANCES (IN.) [mm]
BACK TOP FRONT VENT
0 1 [25] 3 [76]
➁
0 1 [25] 3 [76]
➁
0 1 [25] 3 [76]
0
0 1 [25] 3 [76]
6 [152]
6 [152]
6 [152] ➂
6 [152]
6 [152] ➂
6 [152]
➂
➂
➂
➂
SHIP. WGTS.
(LBS.) [kg]
85 [38.6]
105 [47.6]
115 [52.2]
120 [54.4]
140 [63.5]
150 [68]

Rheem Heating, Cooling and Water Heating 5
NOTES: ➀ Not to be used as a low stage heating speed.
Data compiled with factory filters installed.
See Form Number C11-211 for “N” Coil Data.
Factory rated to 0.5" W.C.
*E = Standard
*N = NOx Models
[ ] Designates Metric Conversions
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited
warranty.
*For Complete Details of the Limited Warranty, Including Applicable
Terms and Conditions, See Your Local Installer or Contact the
Manufacturer for a Copy.
Gas Heat Exchanger Limited Warranty .........Limited Lifetime
Conditional Parts* (Registration Required) ......Ten (10) Years
BLOWER PERFORMANCE DATA—DOWNFLOW MODELS
MODEL
NUMBER
RGLQ-
SERIES
05*AUER
07*AMER
10*AMER
10*BRJR
12*ARJR
15*ARJR
BLOWER
SIZE
[mm]
11 x 6
[279 x 152]
11 x 7
[279 x 178]
11 x 7
[279 x 178]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
MOTOR
H.P.
[W]
1/2
[373]
1/2
[373]
1/2
[373]
3/4
[559]
3/4
[559]
3/4
[559]
BLOWER
SPEED
LOW
MED-LO
MED-HI
HIGH
LOW ➀
MED-LO
MED-HI
HIGH
LOW 895 [422] 874 [412] 852 [402] 825 [389] 798 [376]
MED-LO
MED-HI
HIGH
LOW
MED-LO
MED-HI
HIGH
LOW
MED-LO
MED-HI
HIGH
LOW
MED-LO
MED-HI
HIGH
EXTERNAL STATIC PRESSURE INCHES [kPa] WATER COLUMN
.1 [.02] .2 [.05] .3 [.07] .4 [.10] .5 [.12] .6 [.15] .7 [.17]
655 [309]
975 [460]
180 [557]
1335 [630]
910 [429]
1074 [507]
1229 [580]
1409 [665]
1052 [496]
1238 [584]
1383 [652]
1374 [648]
1709 [806]
2132 [1006]
2362 [1114]
1315 [620]
1618 [763]
2065 [974]
2275 [1074]
1300 [614]
1675 [791]
2105 [993]
—
630 [297]
943 [445]
1140 [538]
1290 [608]
887 [418]
1054 [497]
1207 [569]
1385 [653]
1033 [487]
1217 [574]
1366 [644]
1356 [640]
1686 [795]
2085 [984]
2300 [1085]
1292 [609]
1597 [753]
2025 [956]
2219 [1047]
1280 [604]
1650 [779]
2075 [979]
2340 [1104]
CFM [L/s] AIR DELIVERY
600 [283]
915 [432]
1105 [521]
1250 [590]
863 [407]
1034 [488]
1184 [558]
1361 [642]
1013 [478]
1196 [564]
1348 [636]
1339 [632]
1663 [784]
2038 [961]
2237 [1055]
1269 [599]
1576 [743]
1984 [936]
2163 [1021]
1230 [580]
1620 [765]
2035 [960]
2290 [1081]
565 [266]
886 [418]
1067 [503]
1202 [567]
839 [396]
1007 [475]
1159 [547]
1329 [627]
991 [467]
1169 [551]
1317 [621]
1323 [624]
1635 [771]
1988 [938]
2173 [1025]
1250 [590]
1552 [732]
1938 [915]
2103 [992]
1205 [569]
1570 [741]
1990 [939]
2215 [1045]
532 [251]
852 [402]
1027 [484]
1157 [546]
814 [384]
979 [462]
1134 [535]
1297 [612]
968 [457]
1143 [539]
1286 [607]
1286 [607]
1607 [758]
1937 [914]
2108 [994]
1231 [581]
1528 [721]
1891 [892]
2042 [964]
1170 [552]
1545 [729]
1955 [923]
2145 [1012]
500 [236]
813 [383]
980 [462]
1110 [524]
776 [366]
944 [455]
1099 [518]
1260 [594]
766 [362] 734 [346]
930 [439]
1094 [516]
1245 [587]
1249 [589]
1562 [737]
1882 [888]
2036 [960]
1194 [563]
1486 [701]
1824 [861]
1982 [935]
1115 [526]
1485 [701]
1900 [897]
2080 [982]
467 [220]
770 [363]
924 [436]
1060 [500]
738 [348]
908 [428]
1063 [501]
1223 [577]
891 [420]
1044 [492]
1203 [567]
1212 [572]
1516 [715]
1827 [862]
1964 [926]
1157 [546]
1443 [681]
1756 [829]
1921 [907]
1030 [486]
1425 [673]
1815 [857]
1995 [942]

6 Rheem Heating, Cooling and Water Heating
RXPF-F01 and F02
FOSSIL FUEL KIT—is for use with Rheem Heat Pumps and Classic
Series warm air furnaces. RXPF-F02 meets TVA requirements.
ACCESSORIES—DOWNFLOW
DOWNFLOW WARNING: Unit design is certified for installation on non-combustible floor. A special factory supplied combustible floor sub-base is
required when installing on a combustible floor. Failure to install the sub-base
may result in fire, property damage and personal injury.
FOR HIGH ALTITUDES:
HIGH ALTITUDE CONVERSION:
See Installation Instructions for more high altitude information.
CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines
when converting furnaces for high altitudes.
COMBUSTIBLE FLOOR BASE DIMENSIONS
RXGF-CC*
FILTER RACK—Downflow top
return mount.
NOTE: Filter racks are shipped
without filters.
*Filters available through PROSTOCK
®
.
[ ] Designates Metric Conversions
COMBUSTIBLE
FLOOR BASE
RXGC-B14
RXGC-B17 18 [457] 163/4 [425]RGLQ-07, RGLQ-10(-)A
RXGC-B21 211/2 [546] 201/4 [514]RGLQ-10(-)B
RXGC-B24
USE WITH
FURNACE SIZES
RGLQ-05
RGLQ-12, RGLQ-15
A
IN. [mm]BIN. [mm]
141/2 [368] 131/4 [337]
25 [635] 233/4 [603]
C
IN. [mm]
111/4 [286]
143/4 [451]
181/4 [464]
213/4 [552]
FURNACE
WIDTH
IN. [mm]
141/2 [356] 45 [13.19] & 50 [14.65] 14 [356] x 20 [508] 1
171/2 [445] 67 [19.64], 75 [21.98] & 100 [29.31] 12 [305] x 20 [508] 1
211/2 [533] 100 [29.31] 12 [305] x 20 [508] 2
241/2 [622] 125 [36.63] & 150 [44.0] 14 [356] x 20 [508] 2
DOWNFLOW FILTER SIZES
INPUT
BTUH [kW]
SIZE
IN. [mm]
QUANTITY

Rheem Heating, Cooling and Water Heating 7
NOTES

Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.
Rheem Heating,
Cooling and
Water Heating
P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A. 10-09 DC FORM NO. G11-491 REV. 1
Supersedes Form No. G11-491