
FORM NO. G11-494 REV. 6
Supersedes Form No. G11-494 Rev. 5
GAS FURNACES
90 PLUS
MODULATING
HORIZONTAL
GAS FURNACES
WITH CONTOUR
COMFORT CONTROL
®
The Rheem Prestige Series™90 Plus High Efficiency line of
horizontal gas furnaces are designed for utility rooms, closets,
or alcoves, attics or crawl spaces.
The design is certified by CSA.
Features
■ Heat exchanger is constructed of all stainless steel for
maximum corrosion resistance and thermal fatigue
reliability.
■ Modulating Function: when used with a modulating ther-
mostat, modulation rate between 40% and 100% of total
capacity.
■ Two-stage Function: when used with a two-stage thermo-
stat, furnace operates at 40% on first stage, and stages
up to 65%, then 100% for second stage.
■ Multistage Function: when used with a single-stage ther-
mostat, furnace functions as a three stage furnace operating at 40%, 65% and 100% of total capacity.
■ Reduced firing rates, electrically efficient ECM2+ motor,
and solid doors provide the ultimate in quiet operation.
■ Low speed constant fan.
■ Constant temperature rise for superior comfort.
■ Seven segment LED for system diagnostics.
■ Diagnostic history for troubleshooting.
■ Two-speed induced draft motor.
■ Direct spark ignition with remote sense.
■ Top electrical connections.
■ Optional indoor or outdoor combustion air.
A variety of cooling coils and plenums designed to use with
the Rheem Prestige Series
™
90 Plus gas furnaces are
available as optional accessories.
✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
of Energy test procedures.
RGJD- SERIES
Models with Input Rates
from 60,000 to 120,000 BTU/HR
[17.58 to 35.16 kW]
RHC-TST401MDMS
(See Accessory Section)
Modulating Furnace
Thermostat

2 Rheem Heating, Cooling and Water Heating
STANDARD EQUIPMENT
Completely assembled and wired; heat exchanger; primary: 409 and aluminized
409 stainless steel, secondary: 29-4C stainless steel; induced draft; pressure
switches; redundant modulating main gas control; blower compartment door
safety switch; solid state time on/off blower control; limit controls; manual shutoff valve; 100% safety lock out; cool fan off delay; one hour automatic retry;
power and self-test diagnostics; flame sense current diagnostics; electronic air
cleaner connections; humidifier connections; humidifier on/off delay, dehumidification connection; low speed continuous fan option; transformer; direct drive,
ECM variable speed blower motor. (Please note: a thermostat is not included as
standard equipment. See “Accessories”).
OPTIONAL EQUIPMENT
NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
All models can be converted by a qualified distributor or local service dealer to
use L.P. (propane) gas without changing burners. Factory approved kits must
be used to convert from natural to L.P. (propane) gas and may be ordered as
optional accessories from a parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
Fossil Fuel Kits for use with heat pumps.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
REMOTE
SENSOR
DIRECT SPARK
IGNITION
DRAFT
INDUCER
INTEGRATED
FURNACE
CONTROL
GAS VALVE
PRESSURE
SWITCHES
PRIMARY AND SECONDARY
HEAT EXCHANGER
BLOWER
ASSEMBLY WITH
ELECTRONIC
COMMUTATED
MOTOR
PRESTIGE SERIES™90 PLUS HIGH EFFICIENCY
MODULATING HORIZONTAL GAS FURNACE
IN-SHOT BURNERS
IGNITION
CONTROL

Rheem Heating, Cooling and Water Heating 3
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS—HORIZONTAL MODELS
MODEL IDENTIFICATION
R
G J D 07E CM K S
Rheem Gas
Furnace
Horizontal
Modulating
Prestige
Series
™
90 Plus
Gas Furnace
Design
Series
Heating Input
Designation
Variations
C = Single/
Multi Zone
Blower Size
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
Z = 12 x 11
[305 x 279 mm]
Heat/Cool
Designation
K = 600-1200 CFM
[283-566 L/s]
M = 1200-2000 CFM
[566-944 L/s]
Fuel Code
S = U.S. or
Canadian
Natural Gas
Electric
Ignition
06E
07E
09E
10E
12E
[ ] Designates Metric Conversions
Electric
Ignition–
NOx Models
06N
07N
09N
10N
12N
Input
BTU/HR
60,000 [17.6 kW]
75,000 [22.0 kW]
90,000 [26.4 kW]
105,000 [30.7 kW]
120,000 [35.2 kW]
Option 278
278 = FactorySupplied High
Altitude Conversion
Kit (Not Required
on 60K BTU Model)
–
MODEL NUMBERS RGJD-06EMCK RGJD-09EZCM RGJD-10EZCM RGJD-12ERCM
INPUT–MAXIMUM (BTU/HR) [kW] 60,000 [17.58] 90,000 [26.38] 105,000 [30.77] 120,000 [35.17]
HEATING CAPACITY–MAXIMUM [kW] 54,720 [16.03] 83,160 [24.37] 95,865 [28.09] 110,880 [32.49]
INPUT–MINIMUM (BTU/HR) [kW] 24,000 [7.03] 36,000 [10.55] 42,000 [12.31] 48,000 [14.07]
HEATING CAPACITY–MINIMUM [kW] 21,888 [6.41] 33,264 [9.75] 38,346 [11.24] 44,352 [12.99]
HEATING EXT. STATIC PRESSURE [kPa] 0.12 [.029] 0.15 [.037] 0.20 [.049] 0.20 [.049]
BLOWER (D X W IN.) [mm] 11 x 7 [279 x 178] 12 x 11 [305 x 279] 12 x 11 [305 x 279] 11 x 10 [279 x 254]
ECM MOTOR HP [W] 1/2 [373] 1 [746] 1 [746] 1 [746]
UNIT AMPS 8.7 12.0 12.0 12.0
HEATING CFM–MAXIMUM [L/s] 795 [375] 1195 [564] 1395 [658] 1595 [753]
HEATING CFM–MINIMUM [L/s] 320 [151] 515 [243] 600 [283] 685 [323]
COOLING CFM–RANGE [L/s] 600-1200 [283-566] 1200-2000 [566-944] 1200-2000 [566-944] 1200-2000 [566-944]
MAXIMUM EXT. STATIC PRESSURE [kPa] 0.80 [0.20] 0.80 [0.20] 0.80 [0.20] 0.80 [0.20]
TEMPERATURE RISE RANGE °F [°C] 40-70 [22.2-38.9] 40-70 [22.2-38.9] 40-70 [22.2-38.9] 40-70 [22.2-38.9]
MAX OUTLET AIR TEMPERATURE °F [°C]
180 [82.2] 180 [82.2] 190 [87.8] 195 [90.6]
RETURN AIR CABINETS–RXGR- C17B C21B C21B C24B
FILTER SIZE (IN.) [mm] BOTTOM 153/4 x 25 [400 x 635] 191/4 x 25 [489 x 635] 191/4 x 25 [489 x 635] 223/4 x 25 [578 x 635]
4 x 25 [400 x 635]
153/
APPROX. SHIPPING WEIGHT (LBS.) [kg] 127 [57.6] 158 [71.7] 162 [73.5] 170 [77.1]
AFUE 94.8 92.3 93.3 93.4
RGJD-07EMCK
75,000 [21.98]
69,000 [20.22]
30,000 [8.79]
27,600 [8.09]
0.12 [.029]
11 x 7 [279 x 178]
1/2 [373]
8.7
15MAXIMUM OVERCURRENT PROTECTION 15 15 15 15
995 [470]
430 [203]
600-1200 [283-566]
0.80 [0.20]
40-70 [22.2-38.9]
180 [82.2]
C17B
153/4 x 25 [400 x 635]
4 x 25 [400 x 635]FILTER SIZE (IN.) [mm] SIDE
153/
133 [60.3]
93.1
4 x 25 [400 x 635]
153/
4 x 25 [400 x 635]
153/
4 x 25 [400 x 635]
153/

4 Rheem Heating, Cooling and Water Heating
HORIZONTAL MODELS
[ ] Designates Metric Conversions
Illustration
A084901.S01D
Illustration
A084901.S01A
Illustration
A084901.S01C
Illustration
A084901.S01B
TOP
RIGHT (RETURN AIR) LEFT (SUPPLY AIR)
MODEL
RGJD-
06
A B C D E F
171/2 [445] 1611/32 [415] 155/8 6[397]
07 171/2 [445] 1611/32 [415] 155/8 6[397] 2 [51] 165/8 [422] 137/8 [352] 0 0 0 1 [25] 2 [51] 0
09
21 [533] 1927/32 [504] 193/16 [487]
10 21 [533] 1927/32 [504] 193/16 [487] 2 [51] 201/8 [511] 173/8 [441] 0 0 0 1 [25] 2 [51] 0
12 241/2 [622] 2311/32 [593] 225/86 [575] 2 [51] 235/8 [600] 207/8 [530] 0 0 0 1 [25] 2 [51] 0
2 [51]
2 [51]
165/8 [422] 137/8 [352]
201/8 [511] 173/8 [441]
LEFT
SIDE
MINIMUM CLEARANCE (IN.) [mm]
RIGHT
SIDE
BACK TOP FRONT VENT
0 0 0 1 [25] 2 [51] 0
0 0 0 1 [25] 2 [51] 0

Rheem Heating, Cooling and Water Heating 5
BLOWER PERFORMANCE DATA—RGJD MODELS
[ ] Designates Metric Conversions
GENERAL TERMS OF LIMITED WARRANTY*
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited
warranty.
Primary and Secondary Heat Exchanger ......Limited Lifetime
Rheem will provide a replacement RGJD Gas Furnace to the
original purchaser if the Heat Exchanger fails AND if the following additional conditions are satisfied:
a) Unit is still owned by the original purchaser; in the
original installation location; AND
b) Warranty is registered with Rheem Manufacturing
Company, Air Conditioning Division within 60 Days of
original installation or closing of your home. Product
registration is available online at www
.RheemAC.com/
register or by filling out the Warranty Registration card
and returning it to the address listed on the reverse side
of the card.
All Other Parts ..............................................Five (5) Years
*For Complete Details of the Limited Warranty, Including Applicable Terms
and Conditions, See Your Local Installer or Contact the Manufacturer for
a Copy.
MODEL
RGJD-
06
07
09
10
12
BLOWER SIZE
(D x W)
IN. [mm]
11 x 7
[279 x 178]
11 x 7
[279 x 178]
12 x 11
[305 x 279]
12 x 11
[305 x 279]
11 x 10
[279 x 254]
ICM
MOTOR H.P.
[W]
1/2
[373]
1/2
[373]
1
[746]
1
[746]
1
[746]
BLOWER
SPEED
HIGH
MED-HI
MED
LOW
HIGH
MED-HI
MED
LOW
HIGH
MED-HI
MED
LOW
HIGH
MED-HI
MED
LOW
HIGH
MED-HI
MED
LOW
CFM [L/s] AIR DELIVERY
EXTERNAL STATIC PRESSURE
INCHES WATER COLUMN [kPa]
0.1 [.02]-0.8 [.20]
1200 [566]
1000 [472]
800 [378]
600 [283]
1200 [566]
1000 [472]
800 [378]
600 [283]
2000 [944]
1600 [755]
1400 [661]
1200 [566]
2000 [944]
1600 [755]
1400 [661]
1200 [566]
2000 [944]
1600 [755]
1400 [661]
1200 [566]

6 Rheem Heating, Cooling and Water Heating
ACCESSORIES—HORIZONTAL
PLENUM DATA FOR “A” COILS
Plenum adapters are required in some instances for use
on horizontal applications when plenum and furnace size do
not match.
VENT TERMINATION KITS CONCENTRIC: HORIZONAL/
VERTICAL =
RXGY-E03A (US & Canadian Installations)
HORIZONTAL TWO PIPE: RXGY-D02, RXGY-D03, RXGY-D04
(US Installations)
RXGY-D02A, RXGY-D03A, RXGY-D04A (Canadian Installations)
RXGY-G02 (US Only)
FUEL KIT: Use Modulating Programmable Thermostat
(see below) for Dual Fuel/Fossil Fuel Kits.
HORIZONTAL: RXGY-G02
NEUTRALIZER KIT: RXGY-A01
Note: See Form Number C11-206 for MultiFlex®coil data.
FOR HIGH ALTITUDES:
RGJD HIGH ALTITUDE FIELD CONVERSION KITS:
*5000 ft. & above only (except where noted).
OPTION CODE FOR HIGH ALTITUDE: U.S. & CANADA – 278
NOTE: High altitude kits and options do NOT include additional
burner orifices. If a burner orifice change is necessary, they
must be ordered through PROSTOCK
®
. See Installation
Instructions for more information.
Option – 278 furnaces are shipped with #51 DMS orifices installed.
This is one drill size smaller than standard furnaces to account for
expected average elevations and heating values typically seen in
these areas.
CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines
when converting furnaces for high altitudes.
For all installations above 2000 ft. (including all option – 278
models), the burner orifice size must be recalculated and
verified. A burner orifice change may still be required. See
Installation Instructions for more information.
Manifold gas pressure reduction methods may NOT be used on
these models. The only method permitted on modulating furnace
models is to recalculate the burner orifice size. See Installation
Instructions for more information.
[ ] Designates Metric Conversions
*PROGRAMMABLE THERMOSTAT ACCESSORIES:
Adapter Plate = F61-2600
Remote F1451328 and F1451378 Sensor
*Available through PROSTOCK
®
.
LP KIT: (Available through PROSTOCK
®
)
U.S./Canadian = RXGJ-FP07
• 7 Day 5/1/1 Programmable Modulating/Two Cool Hardwired
• Works in Modulating Furnace and Modulating Furnace Dual Fuel
applications (requires optional external sensor)
• Bright, 12 sq. inch touchscreen display
• Keypad lockout option
• Hardwired
• Easy, menu-driven programming
• Audio prompting to ensure program change confirmation
• Intuitive red/blue temperature keys
• Large, easy-to-see characters
• Available only through professional contractors
RHC-TST401MDMS
THERMOSTATS
RECOMMENDED MODULATING FURNACE THERMOSTAT
FURNACE
WIDTH
IN. [mm]
171/2 [445] 161/4 [413] RXAA-C186 RXAL-B16BU
171/2 [445] 201/4 [514] RXAA-C173 RXAL-B20BU
171/2 [445] 215/8 [549] RXAA-C187 RXAL-B21BU
171/2 [445] 251/4 [641]
21 [533] 251/4 [641]
21 [533] 221/4 [565] RXAA-C176 RXAL-B22BU
21 [533] 215/8 [549]
241/2 [622] 251/4 [641] RXAA-C177 RXAL-B25BU
241/2 [622] 215/8 [549] RXAA-C187 RXAL-B21BU
PLENUM
WIDTH
IN. [mm]
PLENUM ADAPTER
UPFLOW
RXAA-C174 RXAL-B25BU
RXAA-C175 RXAL-B25BU
RXAA-C188 RXAL-B21BU
PLENUM
COIL
MODEL INPUT
RGJD-06* 60,000 None Needed
RGJD-07* 75,000
RGJD-09* 90,000
RGJD-10* 105,000
RGJD-12* 120,000
RXGY-F23 (8000 ft. and above only)
RXGY-F24
RXGY-F25
RXGY-F26
HIGH ALTITUDE
FIELD CONVERSION KIT NO.

Rheem Heating, Cooling and Water Heating 7
NOTES

Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.
Rheem Heating,
Cooling and
Water Heating
P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A. 12-08 DC FORM NO. G11-494 REV. 6
Supersedes Form No. G11-494 Rev. 5