Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to 35.16 kW] (U.S. & Canadian Models)
COMFORT CONTROL
®
The Rheem Prestige Series™90 Plus High Efficiency line of downflow gas furnaces are designed for utility rooms, closets, or alcoves, attics or crawl spaces.
The design is certified by CSA.
Features
Heat exchanger is constructed of all stainless steel for
maximum corrosion resistance and thermal fatigue reliability.
Modulating Function: when used with a modulating ther-
mostat, modulation rate between 40% and 100% of total capacity.
Two-stage Function: when used with a two-stage thermo-
stat, furnace operates at 40% on first stage, and stages up to 65%, then 100% for second stage.
Multistage Function: when used with a single-stage ther-
mostat, furnace functions as a three stage furnace oper­ating at 40%, 65% and 100% of total capacity.
Reduced firing rates, electrically efficient ECM2+ motor,
and solid doors provide the ultimate in quiet operation.
Low speed constant fan.
Constant temperature rise for superior comfort.
Seven segment LED for system diagnostics.
Diagnostic history for troubleshooting.
Two-speed induced draft motor.
Direct spark ignition with remote sense.
Top electrical connections, left or right gas and conden-
sate drainage connections on downflow models.
Optional indoor or outdoor combustion air.
All models comply with Department of Energy test proce-
dures for 2% or less electrical efficiency ratings. A variety of cooling coils and plenums designed to use with the Rheem Prestige Series
90 Plus gas furnaces are
available as optional accessories.
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
of Energy test procedures.
RHC-TST412MDMS
Modulating Furnace
Thermostat
“Visit www.Rheem.com/
taxcredit for complete details.”
2 Rheem Heating, Cooling and Water Heating
STANDARD EQUIPMENT
Completely assembled and wired; heat exchanger; primary: 409 and aluminized 409 stainless steel, secondary: 29-4C stainless steel; induced draft; pressure switches; redundant modulating main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut­off valve; 100% safety lock out; cool fan off delay; one hour automatic retry; power and self-test diagnostics; flame sense current diagnostics; electronic air cleaner connections; humidifier connections; humidifier on/off delay, dehumid­ification connection; low speed continuous fan option; transformer; direct drive, ECM variable speed blower motor. (Please note: a thermostat is not included as standard equipment. See “Accessories”).
OPTIONAL EQUIPMENT
NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form. Fossil Fuel Kits for use with heat pumps.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
PRIMARY AND SECONDARY HEAT EXCHANGER
IN-SHOT
BURNERS
PRESSURE SWITCHES
BLOWER ASSEMBLY WITH
ELECTRONIC COMMUTATED
MOTOR
DRAFT INDUCER
INTEGRATED FURNACE CONTROL
GAS VALVE
IGNITION CONTROL
PRESTIGE SERIES
90 PLUS HIGH EFFICIENCY
MODULATING DOWNFLOW GAS FURNACE
REMOTE SENSOR
DIRECT SPARK IGNITION
Rheem Heating, Cooling and Water Heating 3
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS—DOWNFLOW MODELS
U.S. and Canadian Models
MODEL IDENTIFICATION
R G G D
07E CM K S
Rheem Gas
Furnace
Downflow
Modulating
Prestige Series
90 Plus
Gas Furnace
Design
Series
Heating Input
Designation
Variations
C = Single/
Multi Zone
Blower Size
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
Z = 12 x 11
[305 x 279 mm]
Heat/Cool
Designation
K = 600-1200 CFM
[283-566 L/s]
M = 1200-2000 CFM
[566-944 L/s]
Fuel Code
S = U.S. or
Canadian Natural Gas
Electric
Ignition
06E 07E 09E 10E 12E
[ ] Designates Metric Conversions
Electric
Ignition–
NOx Models
06N 07N 09N 10N 12N
Input
BTU/HR
60,000 [17.6 kW] 75,000 [22.0 kW]
90,000 [26.4 kW] 105,000 [30.7 kW] 120,000 [35.2 kW]
Option 278
278 = Factory Supplied
High Altitude Conversion Kit
MODEL NUMBERS RGGD-06EMCK RGGD-09EZCM RGGD-10EZCM RGGD-12ERCM
INPUT–MAXIMUM (BTU/HR) [kW] 60,000 [17.58] 90,000 [26.38] 105,000 [30.77] 120,000 [35.17] HEATING CAPACITY–MAXIMUM [kW] 54,720 [16.03] 83,160 [24.37] 95,865 [28.09] 110,880 [32.49] INPUT–MINIMUM (BTU/HR) [kW] 24,000 [7.03] 36,000 [10.55] 42,000 [12.31] 48,000 [14.07] HEATING CAPACITY–MINIMUM [kW] 21,888 [6.41] 33,264 [9.75] 38,346 [11.24] 44,352 [12.99] HEATING EXT. STATIC PRESSURE [kPa] 0.12 [.029] 0.15 [.037] 0.20 [.049] 0.20 [.049] BLOWER (D X W IN.) [mm] 11 x 7 [279 x 178] 12 x 11 [305 x 279] 12 x 11 [305 x 279] 11 x 10 [279 x 254] ECM MOTOR HP [W] 1/2 [373] 1 [746] 1 [746] 1 [746] UNIT AMPS 8.7 12.0 12.0 12.0
HEATING CFM–MAXIMUM [L/s] 795 [375] 1195 [564] 1395 [658] 1595 [753] HEATING CFM–MINIMUM [L/s] 320 [151] 515 [243] 600 [283] 685 [323] COOLING CFM–RANGE [L/s] 600-1200 [283-566] 1200-2000 [566-944] 1200-2000 [566-944] 1200-2000 [566-944] MAXIMUM EXT. STATIC PRESSURE [kPa] 0.80 [0.20] 0.80 [0.20] 0.80 [0.20] 0.80 [0.20] TEMPERATURE RISE RANGE °F [°C] 40-70 [22.2-38.9] 40-70 [22.2-38.9] 40-70 [22.2-38.9] 40-70 [22.2-38.9] MAX OUTLET AIR TEMPERATURE °F [°C] RETURN AIR CABINETS–RXGR- C17B C21B C21B C24B FILTER SIZE (IN.) [mm] BOTTOM 153/4 x 25 [400 x 635] 191/4 x 25 [489 x 635] 191/4 x 25 [489 x 635] 223/4 x 25 [578 x 635]
APPROX. SHIPPING WEIGHT (LBS.) [kg] 127 [57.6] 158 [71.7] 162 [73.5] 170 [77.1] AFUE 90.3% 92.3% 91% 92.2%
180 [82.2] 180 [82.2] 190 [87.8] 195 [90.6]
4 x 25 [400 x 635]
153/
RGGD-07EMCK
75,000 [21.98] 69,000 [20.22] 30,000 [8.79] 27,600 [8.09]
0.12 [.029]
11 x 7 [279 x 178]
1/2 [373]
8.7 15MAXIMUM OVERCURRENT PROTECTION 15 15 15 15
995 [470] 430 [203]
600-1200 [283-566]
0.80 [0.20]
40-70 [22.2-38.9]
180 [82.2]
C17B
153/4 x 25 [400 x 635]
4 x 25 [400 x 635]FILTER SIZE (IN.) [mm] SIDE
153/
133 [60.3]
90.3%
4 x 25 [400 x 635]
153/
4 x 25 [400 x 635]
153/
4 x 25 [400 x 635]
153/
Loading...