INDOOR COILS
RCQC­SUPER HIGH EFFICIENCY INDOOR COILS
AIRFLOW CAPACITIES 600-1,900 CFM [283-897 L/s]
Rheem®Indoor Coils are designed for use with Rheem out­door units and are available for vertical upflow, horizontal left or horizontal right airflow. When matched with Rheem outdoor units, the coils provide a capacity range from 24,000 BTU/HR [7.04 kW] to 54,500 BTU/HR [16.0 kW].
Constructed of aluminum fins bonded to intergrooved
copper tubing.
Coils are tested at the factory with an extensive refriger-
ant leak check for improved quality control.
Coils have sweat fitting refrigerant connections.
Ideally suited for new installations or add on air
conditioning.
Condensate drain connections are
3
/4" [19.1 mm] N.P.T. for
ease of connection.
Coils are A.R.I. certified for system application with variety
of Rheem outdoor units.
Condensate drain pan is constructed of high grade, heat
resistant, corrosion free thermal-setting material.
Compatible with Germicidal Light System
2 Rheem Manufacturing Company
RCQC—2417AS
Sweat
Variation A = Standard High Efficiency Coil B = 16-SEER Application
Coil Casing 17 = 17" [431.8 mm] 21 = 21" [533.4 mm] 24 = 24" [609.6 mm]
Nominal Capacity 24 = 24,000 BTUH
[7.03 kW] 30 = 30,000 BTUH [8.79 kW] 31 = 30,000 BTUH [8.79 kW] 36 = 30,000 to 36,000 BTUH
[8.79 to 10.55 kW] 48 = 42,000 to 48,000 BTUH
[12.31 to 14.06 kW] 49 = 42,000 to 48,000 BTUH
[12.31 to 14.06 kW] 60 = 48,000 to 60,000 BTUH
[14.06 to 17.58 kW] 61 = 60,000 BTUH
[17.58 kW]
Design Series
Type of Coi l Q = High Efficiency A/C
with Expansion Valve
Coil
Rheem
MODEL NUMBER DATA
Coil Specifications/Airflow Pressure Drop
H = Horizontal airflow, U = Upflow
Approx.
Design
Air Flow
CFM [L/s]
Range
600/1000
[283/472]
1000/1200
[472/566]
1000/1200
[472/566]
800/1200
[378/566]
800/1400
[378/661]
1200/1600
[566/755]
1200/1800
[566/850]
1200/1400
[566/661]
100/1600
[47/755]
1500/1900
[708/897]
1400/1700
[661/802]
640/800
[302/378]
800/1000
[378/472]
960/1275
[453/602]
Face Area
Sq. Ft.
2
[m
]
3.89
[0.36]
5.83
[0.54]
5.83
[0.54]
4.38
[0.41]
4.38
[0.41]
5.83
[0.54]
5.83
[0.54]
5.83
[0.54]
5.83
[0.54]
5.83
[0.54]
7.29
[0.68]
4.38
[0.41]
5.83
[0.54]
5.83
[0.54]
Fins-in.
Rows Deep
14/3
14/3
14/3
14/3
14/3
14/3
14/3
13/4
13/4
14/3
14/4
14/3
14/3
14/3
600
[285]
.10
[.025]
.06
[.015]
700
[330]
.14
[.035]
.10
[.025]
Static Pressure Drop Through Wet Cooling Coil [kPa] (Inches H20) CFM [L/s]
800
[380]
.19
[.047]
[.057]
.14
[.035]
[.042]
.08
[.020]
[.025]
.14
[.035]
[.042]
.08
[.020]
[.027]
Model
Number
RCQC-
Type
Air
Flow
STANDARD HORIZONTAL COOLING COILS
2417AS U-H
3121AS U-H
3124AS U-H
3617AS U-H
3621AS U-H
4821AS U-H
4824AS U-H
4921AS U-H
4924AS U-H
6024AS U-H
6124AS U-H
HIGH EFFICIENCY COOLING COILS
2417BS U-H
3021BS U-H
3624BS U-H
900
[425]
.23
.17
.10
.17
.11
1000 [470]
.27
[.067]
.14
[.035]
.11
[.027]
.21
[.052]
.13
[.032]
.14
[.035]
.11
[.027]
.14
[.035]
.11
[.027]
1100 [519]
.17
[.042]
.13
[.032]
.25
[.062]
.16
[.040]
.17
[.042]
.13
[.032]
.13
[.032]
1200 [565]
.19
[.047]
.15
[.037]
.29
[.072]
.18
[.045]
.19
[.047]
.15
[.037]
.23
[.057]
.15
[.037]
.15
[.037]
1300 [614]
.21
[.052]
.22
[.055]
.17
[.042]
.26
[.065]
.18
[.045]
.17
[.042]
.17
[.042]
1400 [660]
.24
[.060]
.25
[.062]
.19
[.047]
.30
[.075]
.21
[.052]
.19
[.047]
.21
[.052]
1500 [708]
.29
[.072]
.23
[.057]
.23
[.057]
.22
[.055]
.23
[.057]
1600 [755]
.32
[.080]
.25
[.062]
.27
[.067]
.24
[.060]
.27
[.067]
1700 [802]
.28
[.070]
.30
[.075]
.27
[.067]
.30
[.075]
1800 [850]
.31
[.077]
.29
[.072]
1900 [897]
.32
[.080]
Loading...