FORM NO. C11-208 REV. 6
Supersedes Form No. C11-208 Rev. 5
INDOOR COILS
RCQCSUPER HIGH
EFFICIENCY
INDOOR COILS
AIRFLOW CAPACITIES
600-1,900 CFM
[283-897 L/s]
Rheem®Indoor Coils are designed for use with Rheem outdoor units and are available for vertical upflow, horizontal
left or horizontal right airflow. When matched with Rheem
outdoor units, the coils provide a capacity range from
24,000 BTU/HR [7.04 kW] to 54,500 BTU/HR [16.0 kW].
■ Constructed of aluminum fins bonded to intergrooved
copper tubing.
■ Coils are tested at the factory with an extensive refriger-
ant leak check for improved quality control.
■ Coils have sweat fitting refrigerant connections.
■ Ideally suited for new installations or add on air
conditioning.
■ Condensate drain connections are
3
/4" [19.1 mm] N.P.T. for
ease of connection.
■ Coils are A.R.I. certified for system application with variety
of Rheem outdoor units.
■ Condensate drain pan is constructed of high grade, heat
resistant, corrosion free thermal-setting material.
■ Compatible with Germicidal Light System
2 Rheem Manufacturing Company
RCQC—2417AS
Sweat
Variation
A = Standard High Efficiency Coil
B = 16-SEER Application
Coil Casing
17 = 17" [431.8 mm]
21 = 21" [533.4 mm]
24 = 24" [609.6 mm]
Nominal Capacity
24 = 24,000 BTUH
[7.03 kW]
30 = 30,000 BTUH [8.79 kW]
31 = 30,000 BTUH [8.79 kW]
36 = 30,000 to 36,000 BTUH
[8.79 to 10.55 kW]
48 = 42,000 to 48,000 BTUH
[12.31 to 14.06 kW]
49 = 42,000 to 48,000 BTUH
[12.31 to 14.06 kW]
60 = 48,000 to 60,000 BTUH
[14.06 to 17.58 kW]
61 = 60,000 BTUH
[17.58 kW]
Design Series
Type of Coi l
Q = High Efficiency A/C
with Expansion Valve
Coil
Rheem
MODEL NUMBER DATA
Coil Specifications/Airflow Pressure Drop
➀ H = Horizontal airflow, U = Upflow
➀
Approx.
Design
Air Flow
CFM [L/s]
Range
600/1000
[283/472]
1000/1200
[472/566]
1000/1200
[472/566]
800/1200
[378/566]
800/1400
[378/661]
1200/1600
[566/755]
1200/1800
[566/850]
1200/1400
[566/661]
100/1600
[47/755]
1500/1900
[708/897]
1400/1700
[661/802]
640/800
[302/378]
800/1000
[378/472]
960/1275
[453/602]
Face
Area
Sq. Ft.
2
[m
]
3.89
[0.36]
5.83
[0.54]
5.83
[0.54]
4.38
[0.41]
4.38
[0.41]
5.83
[0.54]
5.83
[0.54]
5.83
[0.54]
5.83
[0.54]
5.83
[0.54]
7.29
[0.68]
4.38
[0.41]
5.83
[0.54]
5.83
[0.54]
Fins-in.
Rows
Deep
14/3
14/3
14/3
14/3
14/3
14/3
14/3
13/4
13/4
14/3
14/4
14/3
14/3
14/3
600
[285]
.10
[.025]
.06
[.015]
700
[330]
.14
[.035]
.10
[.025]
Static Pressure Drop Through Wet Cooling Coil [kPa] (Inches H20) CFM [L/s]
800
[380]
.19
[.047]
[.057]
.14
[.035]
[.042]
.08
[.020]
[.025]
.14
[.035]
[.042]
.08
[.020]
[.027]
Model
Number
RCQC-
Type
Air
Flow
STANDARD HORIZONTAL COOLING COILS
2417AS U-H
3121AS U-H
3124AS U-H
3617AS U-H
3621AS U-H
4821AS U-H
4824AS U-H
4921AS U-H
4924AS U-H
6024AS U-H
6124AS U-H
HIGH EFFICIENCY COOLING COILS
2417BS U-H
3021BS U-H
3624BS U-H
900
[425]
.23
.17
.10
.17
.11
1000
[470]
.27
[.067]
.14
[.035]
.11
[.027]
.21
[.052]
.13
[.032]
.14
[.035]
.11
[.027]
.14
[.035]
.11
[.027]
1100
[519]
.17
[.042]
.13
[.032]
.25
[.062]
.16
[.040]
.17
[.042]
.13
[.032]
.13
[.032]
1200
[565]
.19
[.047]
.15
[.037]
.29
[.072]
.18
[.045]
.19
[.047]
.15
[.037]
.23
[.057]
.15
[.037]
.15
[.037]
1300
[614]
.21
[.052]
.22
[.055]
.17
[.042]
.26
[.065]
.18
[.045]
.17
[.042]
.17
[.042]
1400
[660]
.24
[.060]
.25
[.062]
.19
[.047]
.30
[.075]
.21
[.052]
.19
[.047]
.21
[.052]
1500
[708]
.29
[.072]
.23
[.057]
.23
[.057]
.22
[.055]
.23
[.057]
1600
[755]
.32
[.080]
.25
[.062]
.27
[.067]
.24
[.060]
.27
[.067]
1700
[802]
.28
[.070]
.30
[.075]
.27
[.067]
.30
[.075]
1800
[850]
.31
[.077]
.29
[.072]
1900
[897]
.32
[.080]