Rudd RCFN-HM2421AC Installation Manual

Page 1
FORM NO. C11-213 REV. 4
Supersedes Form No. C11-213 Rev. 3
INDOOR COILS
CASED/UNCASED COILS FOR GAS AND OIL FURNACES
AIRFLOW CAPACITIES 600-1,900 CFM [283-897 L/s]
Rheem®Indoor Coils are designed for use with Rheem out­door units and are available for vertical upflow or downflow, and horizontal left or horizontal right airflow. When matched with Rheem outdoor units, the coils provide a nominal capacity of 24,000 to 60,000 BTU/HR [7.03 to 17.6 kW].
Constructed of aluminum fins bonded to internally
grooved copper tubing.
Coils are tested at the factory with an extensive refriger-
ant leak check.
Coils have sweat refrigerant connections.
Ideally suited for new installations or add on air
conditioning.
Feature two sets of
3
/4" [14.1 mm] N.P.T. Condensate
drain connections for ease of connection.
Coils are AHRI certified for system application with variety
of Rheem outdoor units.
Condensate drain pan is constructed of high grade, heat
resistant, corrosion free thermal-set material.
Compatible with Germicidal Light System (UV resistant)
Bi-Directional airflow eliminates the need to switch any
internal components from horizontal left to right.
Unique drain pan design maximizes application flexibility
and condensate removal.
RCFN- featuring Industry Standard R-410A Refrigerant
Page 2
2 Rheem Heating, Cooling and Water Heating
RCFN—HM2417AC
Gas/Oil Furnace Coil
C = Cased U = Uncased
Design Variation
A = 1st Design
Coil Size
17 = 17.5" [444 mm] 21 = 21" [533 mm] 24 = 24.5" [622 mm]
Nominal Capacity
24 = 24,000 BTU/HR
[7.03 kW]
36 = 36,000 BTU/HR
[10.6 kW]
48 = 48,000 BTU/HR
[14.7 kW]
60 = 60,000 BTU/HR
[17.6 kW]
Cased Coil Airflow:
HM = A/C or Heat Pump, Multi-Position
Uncased Coil Airflow:
HU = A/C or Heat Pump, Upflow/Downflow
Refrigerant
N = R-410A (18 SEER)
F = Product Generation
Classification
C = Coil
Rheem
MODEL NUMBER DATA
Table 1: Coil Specifications/Airflow Pressure Drop
NOTE: Represents Coil-Only Airflow Ratings
[ ] Designates Metric Conversions
Coil
Model
Number
Approx.
Design
Air Flow
CFM [L/s]
Range
Face Area
Sq. Ft.
2
[m
]
Fins-in.
Rows Deep
HIGH EFFICIENCY COOLING COILS
2417
2421
3624
4824
6024
600/800
[283/378]
600/800
[283/378]
825/1175
[389/555]
1000/1600
[472/755]
1050/1700
[496/802]
5.70
[0.53]
5.70
[0.53]
9.98
[0.93]
9.98
[0.93]
9.98
[0.93]
16/2
16/2
14/3
14/3
14/3
600
[283]
0.07
[0.02]
0.05
[0.01]
700
[330]
0.12
[0.03]
0.10
[0.02]
Static Pressure Drop Through Wet Cooling Coil [kPa] (Inches W.C.) CFM [L/s]
800
900
1000
[378]
0.17
[0.04]
0.15
[0.04]
0.07
[0.02]
[425]
0.21
[0.05]
0.18
[0.04]
0.09
[0.02]
1100
[472]
[519]
0.11
0.11
0.11
0.14
[0.03]
0.14
[0.03]
0.14
[0.03]
[0.03]
[0.03]
[0.03]
1200 [566]
0.16
[0.04]
0.16
[0.04]
0.16
[0.04]
1300
1400
1500
1600
1700
[614]
[661]
[708]
[756]
[802]
1800 [850]
0.19
0.21
0.24
[0.05]
0.19
[0.05]
[0.05]
0.21
[0.05]
[0.06]
0.24
[0.06]
0.27
[0.07]
0.27
[0.07]
0.31
[0.08]
1900 [897]
Page 3
Rheem Heating, Cooling and Water Heating 3
[ ] Designates Metric Conversions
FRONT VIEW
SIDE VIEW
FIGURE 1: DIMENSIONS
PLENUM WIDTH
Casing top and bottom openings are the same dimensions.
Table 2: Coil Dimensions and Weights
Coil
Model
Number
Liquid I.D. Suction I.D. A B
2417 2421 3624 4824 6024
Sweat (in.) [mm]
3
/8[9.53]
3
/8[9.53]
3
/8[9.53]
3
/8[9.53]
3
/8[9.53]
Connections
3
/4[19.05] 171/2[445] 177/8[454] 52 [24] 57 [26]20 [508]
3
/4[19.05] 21 1/2[533] 171/2[445]
7
/8[22.23] 241/2[622] 301/4[768]
7
/8[22.23] 241/2[622] 301/4[768]
7
/8[22.23] 241/2[622] 301/4[768]
Cased Coil Dimensions
(in) [mm]
Weight
C
Coil Weight
(lbs.) [Kg.]
Shipping Weight
(lbs.) [Kg.]
52 [24] 60 [27]20 [508] 32 [813] 108 [49] 118 [54] 32 [813] 108 [49] 118 [54] 32 [813] 108 [49] 118 [54]
197/8
[505 mm]
A MINUS ONE INCH
NOTE: FLANGES ARE PROVIDED FOR FIELD INSTALLATION
13
/16[46 mm]
53/8
[136.5 mm]
PRIMARY DRAIN
3
/4N.P.T. (VERTICAL & HORIZONTAL)
1
1
/4[57.1 mm]
2
SECONDARY DRAIN
3
/4N.P.T. (VERTICAL)
7
/16
[11.1 mm]
1
1
/4
[31.7 mm]
PRIMARY DRAIN
3
/4N.P.T. (VERTICAL)
SUCTION LINE
LIQUID LINE
15
5
[150.8 mm]
1
17/16
[36.5 mm]
/16
1
/8
4
[104.7 mm]
11
/16
21
[550.8 mm]
/2[12.7 mm]
Page 4
4 Rheem Heating, Cooling and Water Heating
Table 4: Horizontal Adapter Kit Model No.
Accessories
• RXBA-AC (Upflow/Horizontal)
These plenum adapter accessories are for use when a cooling coil is matched with a gas furnace of one smaller size.
• HORIZONTAL ADAPTER KIT RXHH (See Figure 2)
This horizontal adapter kit is used to convert a upflow or downflow coil for a horizontal application. See Table 4 to order the proper horizontal adapter kit.
Table 3: Coil Application
Coils can be matched to heating products as listed in table below.
FIGURE 2: HORIZONTAL ADAPTER KIT ILLUSTRATION
RXBC—D21AI
INSULATION
I = Insulated Blank = Uninsulated
HEIGHT
A = 20" [508 mm] B = 28" [711 mm]
CABINET WIDTH
17 = 17.5" [444 mm] 21 = 21" [533 mm] 24 = 24.5" [622 mm]
DESIGN SERIES
COIL CASING
BLOWER UNIT
ACCESSORY
RHEEM
Table 5: Unit Dimensions and Weights- RXBC Indoor Coil Casings
• INDOOR COIL CASING- RXBC (See Table 5)
HORIZONTALADAPTER KIT (RXHH-)
*Note: Due to the proximity of the drain pan to the high temperature oil furnace drum, horizontal left application is NOT permitted on all oil furnaces.
[ ] Designates Metric Conversions
Furnace Width
Coil Model
Oil* Gas
2417 21 [533]
21 [533]2421
3624 4824
241/2[622]
(In.) (mm)
171/2[444] 14 [356] 21 [533]
[444]
171/
2
241/2[622]
21 [533]6024
Coil Model Horizontal Adapter Kit Model No.
2417/2421 RXHH-A03
3624/4824/6024 RXHH-A05
Unit Weight
Weight
(lbs.) [Kg.]
18 [8] 161/2[419]23 [10]
8
Ship. Wt.
(lbs.) [Kg.]
26 [12] 36 [16]RXBC-D21B1 21 [533] 28 [711] 27 [12] 20 [508] 44 [20]RXBC-D24A1 241/2[622] 321/2[826] 34 [15] 231/2[597]
Model
Number
RXBC-D17A1 171/2[445] 20 [508] RXBC-D21A1 21 [533] 20 [508] 20 [9] 20 [508]
Width
(in.) [mm]
(in.) [mm]
Height
Depth
(in.)
[mm]
215/ [549]
Supply Air/Return
Air Openings
Depth
Width
(in.) [mm]
[mm]
1931/
[507]
(in.)
32
AIR FLOW HORIZONTAL-DUAL DIRECTION
Page 5
Rheem Heating, Cooling and Water Heating 5
Accessories (cont.)
UNCASED COIL ADAPTER KIT RXBA- (See Figure 3 & 4)
This uncased coil adapter kit is used to adapt the coil to a furnace or ductwork. See Table 6 to order the proper adapter kit. Each kit contains a quantity of 20 adapters.
FIGURE 3: UNCASED COIL ADAPTER KIT ILLUSTRATION
FIGURE 4: UNCASED COIL ADAPTER KIT ASSEMBLED
Note: Sliding the coil into the coil rail before attaching coil rack front.
[ ] Designates Metric Conversions
Table 6: Uncased Coil Adapter Kit
11/2
[41 mm]
11
/16
7
[196 mm]
A
[516 mm]
Uncased Coil Adapter
Model Number RXBA
B17x20 165/8[422] B21x20 201/8[511]
5
20
/16
A
Width (in.) [mm]
Uncased Coil
Model RCFA/L
-HUxx17
-HUxx21
-HUxx24B24x20 235/8[599]
Page 6
6 Rheem Heating, Cooling and Water Heating
NOTES
Page 7
Rheem Heating, Cooling and Water Heating 7
NOTES
Page 8
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
Rheem Heating, Cooling and Water Heating
P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A. 7-10 DC FORM NO. C11-213 REV. 4
Supersedes Form No. C11-213 Rev. 3
Loading...