Rudd RCFA-HM2414AC, RCFA-2417 Installation Manual

FORM NO. C11-211 REV. 3
Supersedes Form No. C11-211 Rev. 2
INDOOR COILS
CASED/UNCASED COILS FOR GAS AND OIL FURNACES
AIRFLOW CAPACITIES 600-1,900 CFM [283-897 L/s]
Rheem®Indoor Coils are designed for use with Rheem out­door units and are available for vertical upflow or downflow, and horizontal left or horizontal right airflow. When matched with Rheem outdoor units, the coils provide a nominal capacity range from 18,000 BTU/HR [5.24 kW] to 60,000 BTU/HR [17.58 kW].
Constructed of aluminum fins bonded to internally
grooved copper tubing.
Coils are tested at the factory with an extensive refriger-
ant leak check.
Coils have sweat refrigerant connections.
Ideally suited for new installations or add on air
conditioning.
Feature two sets of
3
/4" [14.1 mm] N.P.T. Condensate
drain connections for ease of connection.
Coils are A.R.I. certified for system application with variety
of Rheem outdoor units.
Condensate drain pan is constructed of high grade, heat
resistant, corrosion free thermal-set material.
Compatible with Germicidal Light System (UV resistant)
Bi-Directional airflow eliminates the need to switch any
internal components from horizontal left to right.
Unique drain pan design maximizes application flexibility
and condensate removal.
Universal Duct Flanges are included with all coil models.
RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant
earth friendly refrigerant
RCFA(L)-HM2414AC RCFA(L)-HM2417AC RCFA(L)-HM3617AC RCFA(L)-HM3621AC RCFA(L)-HM4821AC RCFA(L)-HM4824AC RCFA(L)-HM6024AC RCFA(L)-AU2414BC RCFA(L)-AU2417BC RCFA(L)-AU3617BC RCFA(L)-AU3621BC
RCFA(L)-AU4821BC RCFA(L)-AU4824BC RCFA(L)-AU6024BC RCFA(L)-HU2414AU RCFA(L)-HU2417AU RCFA(L)-HU3617AU RCFA(L)-HU3621AU RCFA(L)-HU4821AU RCFA(L)-HU4824AU RCFA(L)-HU6024AU
Available Models of RCFA(L) Coils
2 Rheem Manufacturing Company
RCFA—HM2414AC
Gas/Oil Furnace Coil
C = Cased U = Uncased
Design Variation
A = 1st Design B = 2nd Design
Coil Size
14 = 14" [356 mm] 17 = 17.5" [431.8 mm] 21 = 21" [533.4 mm] 24 = 24.5" [609.6 mm]
Nominal Capacity
24 = 18,000 to 24,000 BTU/HR
[5.27 to 7.03 kW]
36 = 30,000 to 36,000 BTU/HR
[8.79 to 10.55 kW]
48 = 42,000 to 48,000 BTU/HR
[12.31 to 14.06 kW]
60 = 60,000 BTU/HR
[17.58 kW]
Cased Coil Airflow:
HM = A/C or Heat Pump, Multi-Position AU = A/C Only, Upflow/Downflow
Uncased Coil Airflow:
HU = A/C or Heat Pump, Upflow/Downflow
Refrigerant
A = R-22 L = R-410A
F = Product Generation
Classification
C = Coil
Rheem
MODEL NUMBER DATA
Table 1: Coil Specifications/Airflow Pressure Drop
NOTE: Represents Coil-Only Airflow Ratings
[ ] Designates Metric Conversions
Coil Model RCFA/
RCFL
Approx.
Design
Air Flow
CFM [L/s]
Range
Face Area
Sq. Ft.
2
[m
]
Fins-in.
Rows Deep
HIGH EFFICIENCY COOLING COILS
2414
2417
3617
3621
4821
4824
6024
600/1000
[283/472]
600/1000
[283/472]
900/1400
[424/661]
900/1400
[424/661]
1200/1800
[566/850]
1200/1800
[566/850]
1600/1900
[755/897]
4.56
[0.42]
4.56
[0.42]
5.70
[0.53]
5.70
[0.53]
8.55
[0.79]
8.55
[0.79]
9.98
[0.93]
16/2
16/2
16/2
16/2
16/2
16/2
14/3
600
[285]
.17
[.043]
.15
[.039]
700
[330]
.21
[.053]
.19
[.049]
Static Pressure Drop Through Wet Cooling Coil [kPa] (Inches W.C.) CFM [L/s]
800
900
1000
[380]
.25
[.063]
.23
[.059]
.17
[.043]
.15
[.038]
[425]
.31
[.080]
.30
[.076]
.21
[.053]
.18
[.047]
[470]
.40
[.100]
.38
[.096]
.26
[.064]
.23
[.058]
1100 [519]
.46
[.117]
.45
[.113]
.31
[.080]
.27
[.069]
1200
1300
1400
1500
1600
1700
[565]
[614]
[660]
[708]
[755]
[802]
1800 [850]
.36
.41
[.092]
.31
[.080]
.22
[.056]
.22
[.056]
[.103]
[.094]
[.063]
[.063]
.37
.25
.28
.32
.25
[.071]
.28
[.071]
[.081]
[.081]
.32
.36
[.092]
.32
[.081]
[.103]
[.103]
.27
[.070]
[.076]
.41
.41
.30
.34
[.084]
1900 [897]
.37
[.094]
Rheem Manufacturing Company 3
[ ] Designates Metric Conversions
FRONT VIEW
SIDE VIEW
FIGURE 1: DIMENSIONS
Casing top and bottom openings are the same dimensions.
Table 2: Coil Dimensions and Weights
*The 14 inch, 2 ton RCFA/RCFL coil (2414) is part of the “N-Coil” design series, even though the coil shape resembles an “A” coil design.
[ ] Designates Metric Conversions
PLENUM WIDTH
Coil
Model
RCFA/RCFL
2417 3617 3621 4821 4824
Sweat (in.) [mm]
Liquid Suction
I.D. I.D.
3
/8[9.53]
3
/8[9.53]
3
/8[9.53]
3
/8[9.53]
3
/8[9.53]
3
/8[9.53]
3
/8[9.53]
3
/4[19.05] 14 1/2[356] 21 1/2[533] 46 [21] 233/16[584]
3
/4[19.05] 171/2[445] 141/2[368] 46 [21]
3
/4[19.05] 171/2[445] 177/8[454] 52 [24] 57 [26]20 1/2[508]
3
/4[19.05] 21 1/2[533] 171/2[445] 54 [24] 60 [27]20 1/2[508]
7
/8[22.23] 21 1/2[533] 257/8[657] 76 [34]
7
/8[22.23] 241/2[622] 253/8[645] 89 [40] 99 [45]32 1/2[812]
7
/8[22.23] 241/2[622] 301/4[768] 108 [49]
A B
Connections
Cased Coil Dimensions
(in) [mm]
C
28 1/2[711]
Coil Weight
(lbs.) [Kg.]
Weight
Shipping Weight
(lbs.) [Kg.]
50 [23]2414* 51 [23]20 1/2[508]
83 [38]
118 [55]32 1/2[812]6024
197/8
[505 mm]
A MINUS ONE INCH
NOTE: FLANGES ARE PROVIDED FOR FIELD INSTALLATION
13
/16[46 mm]
53/8
[136.5 mm]
PRIMARY DRAIN
3
/4N.P.T. (VERTICAL & HORIZONTAL)
1
1
/4[57.1 mm]
2
SECONDARY DRAIN
3
/4N.P.T. (VERTICAL)
7
/16
[11.1 mm]
1
1
/4
[31.7 mm]
PRIMARY DRAIN
3
/4N.P.T. (VERTICAL)
SUCTION LINE
LIQUID LINE
15
5
[150.8 mm]
1
17/16
[36.5 mm]
/16
1
/8
4
[104.7 mm]
11
/16
21
[550.8 mm]
/2[12.7 mm]