The product information and design
disclosed herein were originated by and are
the property of Bosch Security Systems, Inc.
Bosch reserves all patent, proprietary design,
manufacturing, reproduction, use and sales
rights thereto, and to any article disclosed
therein, except to the extent rights are
expressly granted to others.
Copyright Notice
Copyright 2012 by Bosch Security Systems,
Inc. All rights reserved. Reproduction, in
whole or in part, without prior written
permission from Bosch is prohibited.
Warranty Notice
See the enclosed warranty card for further
details.
Customer Support
Technical questions should be directed to:
Customer Service Department
Bosch Security Systems, Inc.
12000 Portland Avenue South
Burnsville, MN 55337 USA
Telephone: 800-392-3497
Fax: 800-323-0498
Factory Service: 800-553-5992
Shipping to the Manufacturer
All shipments of product should be made via
UPS Ground, prepaid (you may request from
Factory Service a different shipment
method). Any shipment upgrades will be
paid by the customer. The equipment should
be shipped in the original packing carton. If
the original carton is not available, use any
suitable container that is rigid and of
adequate size. If a substitute container is
used, the equipment should be wrapped in
paper and surrounded with at least four (4)
inches of excelsior or similar shockabsorbing material. All shipments must be
sent to the following address and must
include the Proof of Purchase for warranty
repair. Upon completion of any repair the
equipment will be returned via United Parcel
Service or specified shipper, collect.
Factory Service Department
Bosch Security Systems, Inc.
8601 East Cornhusker Hwy.
Lincoln, NE 68507 U.S.A.
Attn: Service
Return Shipping Instructions
Parts & Service Department
Bosch Security Systems, Inc. (Lincoln, NE)
Telephone: 402-467-5321
Fax: 402-467-3279
Factory Service: 800-553-5992
Please include a note in the box which
supplies the company name, address, phone
number, a person to contact regarding the
repair, the type and quantity of equipment, a
description of the problem and the serial
number(s).
1. Remove the two (2) screws holding the mounting plate to the operator assembly.
(See Figure 2 .)
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
2 Installation and Operation ICW-6 Window Intercom
2. Measure and identify the location where the intercom is to be mounted.
3. Attach the mounting template (supplied in box) to the window (customer
assembly side) being sure to center the appropriate guide in the location identified
in step 2.
NOTE: Use either the single large hole, or multiple small holes depending
on which method you choose. Using the multiple small hole
method with bullet-proof glass will afford maximum operator
protection (Figure 4).
4. Cut and/or drill the hole(s) from the customer assembly side.
5. Have an assistant place the customer assembly against the window. Make sure
the holes line up correctly.
6. Attach the mounting plate removed from the operator assembly (See Step 1)
using the three (3) supplied mounting screws and rubber washers. (See Figure 5).
7. Remove the lower left screw and washer and attach the ground wire (See
Figure 6).
CAUTION: Do not let the intercom hang by the ground wired. The connection
may break.
8. Attach the cable harness from the customer assembly to the connector on the
operator assembly (See Figure 6).
9. Attach the operator assembly to the mounting plate using the screws removed
in Step 1.
10. Screw the threaded end of the ICW-6 power supply interface cord into the ICW-
6. The connector is located on the bottom of the ICW-6 on the operator assembly
side.
11. Secure the cord to the glass using wide clear adhesive tape.
12. Connect the power supply to AC power using the supplied IEC cord.
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
ICW-6 Window IntercomInstallation and Operation 3
13. Attach the ICW-6’s power cord to the power supply.
FIGURE 3. Operator and Customer assemblies
FIGURE 4. Mounting Template
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
4 Installation and Operation ICW-6 Window Intercom
FIGURE 5. Customer Side Mounted
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
ICW-6 Window IntercomInstallation and Operation 5
FIGURE 6. Connecting customer and operator assemblies prior to final
mounting.
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
6 Installation and Operation ICW-6 Window Intercom
Operation
Inside and Outside Mic Adjustment Pot
On the ICW-6, you can adjust the sensitivity of the inside and outside mic. This
means the how far away from the microphone a person can stand to talk and still be
heard.
Mic Adjustment Pot Location
By default, the following applies:
•The inside mic is set midpoint, 2”- 3” Speak Zone
•The outside mic is set midpoint, 1’ - 2’ Speak Zone
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
ICW-6 Window IntercomInstallation and Operation 7
FIGURE 7. ICW-6 Inside and Outside Mic Pot Location
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
To adjust the inside or outside mic sensitivity level, do the following:
1.Using a small screwdriver, remove the two (2) side screws from the operator
side unit.
FIGURE 8. Side Screws Holding the Back Plate to the Operator Unit
2.Carefully remove the back plate from the operator side unit.
3.Using Figure 7 , locate the mic pot you want to adjust.
4.With a flathead screwdriver, turn the mic pot clockwise to increase the
sensitivity.
OR
Turn the mic pot counter-clockwise to decrease the sensitivity.
ICW-6 Window IntercomInstallation and Operation 9
Notes
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
Bosch Security Systems, Inc.
12000 Portland Avenue South
Burnsville, MN 55337 U.S.A.
www.boschcommunications.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.