The Rosemount 3900 and 3900VP pH/ORP combination sensors are used for reliable pH or oxidation/
reduction potential measurements of aqueous solutions in pipelines, open tanks, or ponds. Its robust
sensor design allows the Rosemount 3900 and 3900VP sensors to be used in a wide range of applications.
Rosemount 3900/3900VPOctober 2019
Overview
A robust sensor design
■
Extended sensor life and protection against poisoning ions
using a double junction reference.
■
Enhanced performance and increased life with cracking
resistant glass.
■
Maximum chemical resistance provided by a rugged
polyphenylene sulfide body.
■
Operates in sub-zero temperatures down to 14 °F (-10 °C).
■
Built-ins solution ground for advanced diagnostics.
Versatile installation options
■
The sensor body features a one-piece construction with both front facing and rear facing process threads.
■
¾-in. and 1-in. MNPT process connections to meet a variety of application installation requirements.
Automatic recognition of pH sensors by Rosemount transmitters: 1066, 1057, 1056, and 56.
■
pH calibration data is stored, which allows sensors to be calibrated in advance for "plug and play" installations in the field.
Ordering information
The Rosemount 3900 and 3900VP General Purpose pH/ORP
sensors feature a chemically resistant Ryton® plastic body,
along with a built-in solution ground for advanced diagnostics
and a Pt-100 resistance temperature device (RTD) for
temperature compensation. These sensors are available with
either an integral cable connection (Rosemount 3900) or
Variopol (VP8) connector (Rosemount 3900VP). Variopol cables
are sold separately (see Accessories).
Dimensional and installation drawings.............................................................................................................................................. 5
LCLoop Calibration Certificate (sensor and transmitter calibrated together, with test
data)
ECElectronic Calibration Certificate (sensor calibrated against factory instrument, with
test data)
Note
The Rosemount 3900 pH/ORP sensor is housed in a Ryton plastic body with built-in solution ground for advanced diagnostics.
Pt-100 is offered for a temperature compensator. The sensor is available with an integral cable. You can mount the sensor using a
process connector, both ordered separately. You can also order junction box kits with preamplifiers separately if the transmitter
does not have an integral preamplifier with 15 ft. (5 m) of the sensor.
Table 2: Rosemount 3900VP Ordering Information
OptionDescription
3900VPGeneral Purpose pH/ORP Sensor with Variopol connector
Preamplifier option
01SMART preamplifier (standard preamplifier if used with ORP)
14 to 212 °F (-10 to 100 °C), automatic temperature compensation from 14 to 212 °F (-10 to 100 °C)
Maximum pressure
100 psig (790 kPa [abs]) at 212 °F (100 °C)
CRN rating: 60 psig up to 212 °F (100 °C)
Materials of construction
Sensor bodyRyton®: polyphenylene sulfide (PPS)
O-ringEPDM
pH electrodeGlass
ORP electrodeGlass, platinum
Solution groundStainless steel
Reference junctionPFTE (Teflon®)
Conductivity
Responds to changes in pH at a minimum conductivity of 0.1 µS/cm when used with the low flow panel. The sample flow rate
must be controlled to 2 gallons per hour (7.61 liters per hour).
Flow rate2 to 5 gallons per hour (7,6 to 18,9 liters per hour)
Sensor threaded connection
24091-001-in. NPT adapter
24091-02¾-in. NPT adapter
8Emerson.com/Rosemount
October 2019
Figure 5: Low Flow Cell (PN 24091-00)
Rosemount 3900/3900VP
A. Inches
B. Millimeters
C. Outlet
D. Inlet
Rosemount 3900/3900VP9
Rosemount 3900/3900VP
Figure 6: Flow-through Tee (2-in.) (PN 914240-XX)
October 2019
A. Adapter
10Emerson.com/Rosemount
October 2019Rosemount 3900/3900VP
The following flow-through tees are available for the Rosemount 3900/3900VP.
■
915240-03
■
915240-04
■
915240-05
For a new installation, use the appropriate tee above and add the S10283-LQD adapter.
When replacing an existing Rosemount 399 with a Rosemount 3900 sensor, add the S10283-LQD adapter to convert the tee to
accept the Rosemount 3900 sensor.
Rosemount 3900/3900VP11
Rosemount 3900/3900VP
Figure 7: Jet Spray Cleaner
October 2019
A. Cleaning solution by others.
B. Solenoid valve or manual valve (supplied by others).
C. Corrosion resistant tubing (supplied by others).
D. Polypropylene ¼-in. compression fitting.
E. ¼-in. 316 stainless steel.
F. ¼-in. polypropylene.
G. Stainless set screw for adjustable spray nozzle height.
H. 2-in. NPT threads.
I. Sensor.
J. 1-in. PVC coupling for submersible applications (supplied by others).
K. 1-in. PVC or stainless conduit (supplied by others).
L. Cable.
M. Timer supplied by others or use timer feature in Rosemount instrument.
12Emerson.com/Rosemount
October 2019Rosemount 3900/3900VP
Figure 8: Rosemount 3900 Sensor with Jet Spray Cleaner
The jet spray cleaner eliminates routine, manual sensor maintenance by cleaning the sensor with water or compressed air. You can
control flow through the cleaner with a solenoid valve.
Note
You can use the jet spray cleaner with the handrail mounting assembly (PN 11275-01, not shown), or you can mount it through the
conduit as shown in Figure 8.
Rosemount 3900/3900VP13
Rosemount 3900/3900VPOctober 2019
Figure 9: Low Flow Panel PN SQP10077-LQD
14Emerson.com/Rosemount
October 2019Rosemount 3900/3900VP
Table 7: Low Flow Panel Specifications
Inlet flow3 to 80 gallons per hour (11,4 to 304 liters per hour)
Inlet pressure3 to 65 psig (122 to 549 kPa [abs])
(1)
Temperature32 to 122 °F (0 to 50 °C)
The minimum inlet pressure is required to open a check valve, which prevents the flow cell from draining if sample flow is lost. Removing the
(1)
check valve lowers the inlet pressure requirement to a few feet of water head.
Rosemount 3900/3900VP15
Rosemount 3900/3900VPOctober 2019
Accessories
Table 8: Accessories
Part numberDescription
11275-01Handrail mounting assembly
12707-00Jet spray cleaner
2002011CPVC flow-through tee, 1½-in. NPT process connection
23242-02Mounting adapter, 1½-in. insertion, 1 x ¾-in.
Emerson Terms and Conditions of Sale are available upon request. The Emerson logo is a
trademark and service mark of Emerson Electric Co. Rosemount is a mark of one of the
Emerson family of companies. All other marks are the property of their respective owners.