Rosemount 370XA Gas Chromatographs Quick Start Guide

Page 1
Gas Supply Separation Kit
for Rosemount™ 370XA Gas Chromatographs
Quick Start Guide
2-3-9000-763, Rev A
April 2019
Page 2
Safety and information notices
WILL CAUSE DEATH
Failure to follow this warning will result in death or serious injury to personnel.
WARNING
DANGER TO PERSONNEL
Failure to follow this warning may result in serious injury to personnel.
CAUTION
MAY CAUSE DAMAGE TO EQUIPMENT
Failure to follow this warning may result in damage to the equipment.
NOTICE
Important messages will appear in this format.
2
Page 3
Quick Start Guide Contents
2-3-9000-763 April 2019

Contents

Chapter 1 Safety requirements.......................................................................................................5
Chapter 1.1 Rosemount™ Gas Chromatograph safety warnings..............................................................5
Chapter 2 Installation.....................................................................................................................7
2.1 Installing the gas separation kit........................................................................................................ 7
Chapter 3 Ordering information.....................................................................................................9
Chapter 3.1 Carrier and actuation gas kit................................................................................................9
Gas Supply Separation Kit iii
Page 4
Contents Quick Start Guide
April 2019 2-3-9000-763
iv Emerson.com/RosemountGasAnalysis
Page 5
Quick Start Guide Safety requirements
2-3-9000-763 April 2019

1 Safety requirements

1.1 Rosemount™ Gas Chromatograph safety warnings

Observe these safety messages for the Rosemount 370XA Gas Chromatograph.
WARNING
EXPLOSION HAZARD Do not open when energized or when an explosive atmosphere may be present.
Failure to de-energize the analyzer may cause serious injury or death to personel.
WARNING
EXPLOSION HAZARD Keep cover tight while circuits alive.
Failure to de-energize the analyzer before removing the cover may cause serious injury or death to personel.
WARNING
EXPLOSION/FIRE HAZARD Do not open when an explosive atmosphere may be present.
Do not open while energized.
Use supply cables or wires suitable for at least 80 (176 ).
Failure to observe this warning may cause serious injury or death to personnel.
WARNING
PHYSICAL ACCESS Unauthorized personnel may potentially cause significant damage to and/or misconfiguration of end users’ equipment. This could be intentional or unintentional and needs to be protected against.
Physical security is an important part of any security program and fundamental to protecting your system. Restrict physical access by unauthorized personnel to protect end users’ assets. This is true for all systems used within the facility.
Gas Supply Separation Kit 5
Page 6
Safety requirements Quick Start Guide
April 2019 2-3-9000-763
6 Emerson.com/RosemountGasAnalysis
Page 7
Quick Start Guide Installation
2-3-9000-763 April 2019

2 Installation

2.1 Installing the gas separation kit

These are the installation instructions for the actuation and carrier gas hardware separation kit for the Rosemount™ 370XA Gas Chromatograph.
This installation kit contains the hardware necessary to separate the actuation gas supply from the carrier gas supply for the analyzer.
The contents of the kit are listed in Table 3-1 and are illustrated in Figure 3-1.
Procedure
1. Shut off the carrier and actuation gas supply.
2. Disconnect the actuation gas tubing from the tee fitting and analyzer manifold as shown in Figure 3-2. Note that the tee fitting may be positioned differently in the original installation.
3. Screw the cap plug (Figure 3-2, Item A) onto the tee fitting where the actuation gas tubing was attached. If the analyzer is in a factory supplied enclosure proceed with
Step 4, Step 5 and Step 6. Otherwise skip to Step 7.
4. If the analyzer is in a factory supplied enclosure, drill another hole through the enclosure to install a bulkhead fitting for the actuation gas supply. The gas line bulkhead fittings are located on the lower left side of the enclosure. Drill a 29/64 in. diameter hole approximately 1 in. to 1½ in. horizontally from the forward bulkhead fitting as shown in Figure 3-3. Install the bulkhead fitting (Table 3-1, Item G).
5. Cut a length of in. tubing (Item F) sufficient to extend from the actuation gas manifold inlet to the bulkhead fitting. A tubing nut and front and rear ferrules (Table 3-1, Items C, D and E) are required to connect the tubing to the manifold. The bulkhead union includes the nut and ferrules.
6. Trim the remaining unused tubing to connect the other end of the bulkhead fitting to the actuation gas supply. A in. tube fitting with male NPT threads (Figure
3-2, Item B) is commonly used to connect in. tubing to the actuation gas pressure
regulator.
7. Cut a length of in. tubing (Table 3-1, Item F) sufficient to extend from the actuation gas manifold inlet to the actuation gas supply. A tubing nut and front and rear ferrules (Table 3-1, Items C, D and E) are required to connect the tubing to the manifold. A in. tube fitting with male NPT threads (Table 3-1, Item B) is used to connect in. tubing to the actuation gas pressure regulator.
8. Open the carrier and actuation gas supplies and set the pressures as appropriate.
Gas Supply Separation Kit 7
Page 8
Installation Quick Start Guide
April 2019 2-3-9000-763
8 Emerson.com/RosemountGasAnalysis
Page 9
Quick Start Guide Ordering information
2-3-9000-763 April 2019

3 Ordering information

3.1 Carrier and actuation gas kit

Table 3-1: Gas Supply Separation Kit P/N 7A00215G01
ITEM QTY PART NO. DESCRIPTION UNITS
A 1 2-4-4000-143 Cap Plug, in. Tubing Connection EA
B 1 2-4-9500-013 Connector, in. MNPT X in. Tubing EA
C 3 2-4-9500-022 in.Tubing Nut, SST EA
D 5 2-6-5000-336 Rear Ferrule, in. Tubing EA
E 5 2-6-5000-334 Front Ferrule, in. Tubing EA
F 10 2-6-5000-487 TUBING, in. OD X .085 in. ID, 316 SS FT
G 1 2-4-4000-119 Bulkhead Union, in. SST Tubing EA
Figure 3-1: Carrier and Actuation Gas Separation Kit - Table Items
A. Cap plug B. in. tubing connector C. in.tubing nut
D. Rear ferrule
E. Front ferrule F. SST tubing, in. OD X .085 in. ID
G. Bulkhead union
Gas Supply Separation Kit 9
Page 10
Ordering information Quick Start Guide
April 2019 2-3-9000-763
Figure 3-2: View of the Rosemount™ 370XA Inlet Gas Manifold
A. Tee fitting B. Acutation gas tubing nuts C. Actuation gas tubing
D. Common carrier and actuation gas supply
10 Emerson.com/RosemountGasAnalysis
Page 11
Quick Start Guide Ordering information
2-3-9000-763 April 2019
Figure 3-3: View of the Rosemount 370XA Actuation Bulkhead Connection
A. Bulkhead fitting drilled hole B. Enclosure
Gas Supply Separation Kit 11
Page 12
2-3-9000-763
Rev. A
2019
AMERICAS
Emerson Automation Solutions 10241 West Little York, Suite 200 Houston, TX 77040 USA
Toll Free 866 422 3683 +1 713 396 8880 (North America) +1 713 396 8759 (Latin America) +1 713 466 8175 gc.csc@emerson.com
EUROPE
Emerson Neuhofstrasse 19a PO Box 1046 CH-6340 Baar Switzerland
+41 (0) 41 768 6111 +41 (0) 41 768 6300 gc.csc@emerson.com
Linkedin.com/company/Emerson-Automation-Solutions
twitter.com/rosemount_news
Facebook.com/Rosemount
youtube.com/RosemountMeasurement
MIDDLE EAST AND AFRICA
Emerson Emerson FZE Jebel Ali Free Zone Dubai, United Arab Emirates, P.O. Box 17033
+971 4 811 8100 +971 4 886 5465 gc.csc@emerson.com
©
2019 Emerson. All rights reserved.
The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners.
ASIA-PACIFIC
Emerson 1 Pandan Crescent Singapore 128461 Republic of Singapore
+65 6 777 8211 +65 6 777 0947 gc.csc@emerson.com
Loading...