Read this manual before working with the product. For personal and system
safety, and for optimum performance, make sure you thoroughly understand the
contents of this manual before installing, using or maintaining this product.
For Assistance:
Within the United States, contact Rosemount Nuclear at
1-952-949-5200.
Outside the United States, contact th e neares t Ros em ount representative.
Customer Feedback:
Your feedback is important to us, please send comments or suggestions to:
Chan.RNII-CustomerFeedback@emersonprocess.com
NOTICE
Title Page iii
Rosemount 356
Reference Manual
00809-0100-4856 Rev AE
February 2020
shown below:
Rosemount 356 Connectors are manufactured under a quality system that meets the requirements of ISO
Rosemount Nucl ear Warranty and Limitations of
Remedy
The warranty and limitations of remedy applicable to this Rosemount equipment are as stated on the
reverse side of the current Rosemount quotation and customer acknowledgment forms.
RETURN OF MATERIAL
Authorization for return is required from Rosemount Nuclear prior to shipment. Contact Rosemount Nuclear
(1-952-949-5200) for details on obtaining Return Material Authorization (RMA). Rosemount Nuclear Instruments will not accept any returned material without a Return Material Authorization. Material
returned without authorization is subject to return to customer.
Material returned for repair, whether in or out of warranty, should be shipped prepaid to:
Rosemount Nuclear
8200 Market Boulevard
Chanhassen, MN 55317
USA
IMPORTANT
Rosemount 356 Nuclear Connector has been tested for Nuclear Class 1E usage according to the standards
•KTA 3505-2005
9001, KTA 1401, KTA 3507 and the applicable portions of IAEA-50-C-Q. During qualification testing,
interfaces were defined betw een trans mitter/connector and the surrounding environment that are essential to
meeting requirements of the qualification standards listed above.
In order to maintain the qualified status of the transmitter/connector system, the essential environmental
interfaces must not be compromised. Performance of any operations on the connector other than those
specifically authorized in this manual has the potential for compromising an essential environmental interface.
Where the manual uses the terms requirement, mandatory, must or required, the instructions so
referenced must be carefully followed. Rosemount Nuclear expressly disclaims all responsibility and
liability for connectors for which the foregoing has not been complied with by the user.
iv Title Page
Reference Manual
00809-0100-4856 Rev AE
February 2020
Rosemount 356
Page
(Rev AD)
Page
(Rev AE)
Cover,
throughout
Cover,
throughout
Change revision date from March 2013 to February 2020; change revision from
AD to AE.
Cover,
throughout
Cover,
throughout
Replace Rosemount Nuclear Instruments, Inc. with Rosemount Nuclear per
current practice.
Throughout
Throughout
Replace reference to Loctite PST 580 with Loctite® 580™.
TOC-2,
1-2, 2-8
TOC-2,
1-2, 2-8
2-2
2-2
Add “as indicated in the 356 Product Data Sheet” for available options.
2-2
2-2
Remove reference to 4-wire configuration.
2-3
2-3
Replace figure 2-1 with better resolution for clarity.
2-3
2-3
Fix typos in “Customer Installed Instrument Side Connector”.
Add figure 2-4a for current configuration with footnote of (As of February 2020)
footnote (Up to February 2020).
2-5
2-5
Fix typo in ‘TEST’ terminal.
2-7
2-7
Add border to figure 2-7.
3-2
3-2
Update figures 3-2 and 3-3 description to remove material reference.
3-3
3-3
Add “Original” to figures 3-4 and 3-5 and footnote of (Up to February 2020).
A-2
A-2
Amend General Considerations.
NOTE
The above Revision Status list summarizes the changes made. Please refer to both manuals for complete
comparison details.
Revision Status
Changes from March 2013 (Rev AD) to February 2020 (Rev AE)
Throughout Throughout
Changes
Replace Emerson logo.
Add “This page intentionally left blank” for clarity.
2-4 2-4
and amended figure 2-4 to be figure 2-4b, Former/Original Configuration with
Title Pagev
Reference Manual
00809-0100-4856 Rev AE
February 2020
Rosemount 356
SECTION 1
Using this Manual ........................................................................ 1-1
This manual is designed to assist in installing, operating and
maintaining the Rosemount 356 Nuclear Connector. The manual is
organized into the following sections:
NOTE
Refer to Rosemount Qualification/Test Reports and Product Data
Sheet
dimensional drawings.
SECTION 1: INTRODUCTION
Section 2: Installation of Instrument Side onto Device
Provides mechanical and electrical installation considerations of
the Instrument Side portion of the connector.
Section 3: Installation of Field Side onto Instrument Side
Provides mechanical and electrical installation considerations of
the Field Side portion of the connector.
Section 4: Maintenance
Provides basic hardware maintenance considerations for the 356
Connector
Appendix A: Procedure for On-site Assembly of Field Side
Connector
Provides instructions for assembling the field side portion of the
connector on-site.
s for details on testing, performance specifications and
o Polarity
o Factory Installed Instrument Side Connector
o Customer Installed Instrument Side Connector
• Mechanical Considerations
• Installation Procedure
o Preparation of the Instrument Side Connector
o Installation of the Instrument Side onto 3152 Pressure
Transmitter
o Electrical Connection to 3152 Pressure Transmitter
precautions to ensure the safety of the personnel performing the
operation. Refer to the following safety messages before performing
an operation preceded by this symbol.
Electrical shock can result in death or in jury.
•Avoid contact with the connector leads and device terminals
When installing the instrument side of the connector onto the
housing of the device, take care to prevent the lead wires from
becoming twisted or from being cut by any potential sharp edges
inside the electronics housing. The same care must be taken when
removing the connector from the device.
Rosemount 356
Reference Manual
00809-0100-4856 Rev AE
February 2020
or to Rosemount transmitters.
NOTE
the instrument/connector interface becomes the user’s responsibility.
NOTE
When installing the 356 on other devices, consult the device
device.
GENERAL
CONSIDERATIONS
Measurement accuracy of any type of instrument depends upon
proper installation of the device and its associated piping, valves,
and electrical connections. W hen insta lling the 356 Connector onto
a device, consider the need for easy access, personnel safety and
suitable connector/device environment.
The 356 Connector is available with M20x1.5 threads or PG13.5
threads as indicated in the 356 Produc t Data Shee t . Before
installing the instrument side onto the intended device, ensure that
the device housing includes compatible threads or that a qualified
thread adaptor is available f or use.
The instructions contained in this section apply only when the 356
Connector is ordered separately from the intended device. If the
356 is not factory-installed, qualification of the device/connector
interface becomes the end user’s responsibility.
The KTA qualification of the 356 was completed in conjunction with
the Rosemount 3152 Pressure Transmitter. As such, most
instructions in this section are focused on activities related to
installation of the instrument side onto the 3152. However, it should
be noted that the use of the 356 Connector is not limited to t he 315 2
If the 356 Connector is not factory-installed by RNII, qualification of
ELECTRICAL
CONSIDERATIONS
Polarity
manufacturer’s documentation for specific instructions related to the
This section contains information to be considered prior to preparing
the instrument side connector for installation. Read this section
carefully before proceeding to ensure the connector and device will
function properly when installed.
Prior to installing a 356 instrument side connector, it is important to
understand the polarity requirements and characteristics of the
connector. Incorrect polarity can lead to non-functioning de vices or ,
in some cases, a damaged device.
The 356 instrument side connector can be provided in 2- or 3-wire
configurations. Figure 2-1 shows the wiring scheme for 2- and 3wire configurations.
Pin #1 or pin #2 can be connected to positive (+) terminal of the
intended device. Careful consideration must be given to ensure that
the same pin is designated and identified as positive (+) on both
instrument side and field side connectors.
2-2
Loading...
+ 25 hidden pages