Ronan X54-3402 User Manual

ISO 9001
REGISTERED
RTD Alarm Trips - Field Configuration Options - High Density DIN Rail Packaging
X54-3402 Dual Channel Universal RTD Alarm Trip
High Density Dual Channel Packaging
Field Configurable Options Including:
f o u r ( 4 ) R T D t y p e s , s e v e n ( 7 ) s t a n d a r d i n p u t s p a n s
with selectable zero offsets, and relay operation
Full Input/Output/Power and Channel Isolation
Front Panel Power/Sensor Fail LED Indicator
Front Access to Zero, Span and Setpoint Controls
Standard 35 mm DIN Rail Mounting
DESCRIPTION:
powered by 24 vdc. Features include: two piece plug-in connectors for easy wiring and maintenance; Power/Sensor Fail LEDs; field configur­able ranges and RTD types; 1000 vac isolation; and front panel ZERO, SPAN, and setpoint adjustments. RFI protection, wide operat­ing temperature, and high accuracy are standard. Dual setpoints are user configured for high or low and have adjustable deadband. Output relays are form “C” and can be normally energized or de-energized. Custom inputs, outputs, and scaling are available from the factory.
SPECIFICATIONS:
Input: RTD sensor types: 100 ohm platinum, 120 ohm nickel,
10 ohm copper. Factory or field configurable.
Input Ranges: Standard factory ranges or field configurable to
application requirements
Input Impedance:
> 100 K ohms.
Setpoint Adjustment:
Front-accessible, multi-turn, infinite resolution potentiometer 2 setpoints per channel. Field select normally energized or de-energized and high or low setpoint relay operation.
Setpoint Repeatability: +/- 0.1% of span Alarm Indication: Front panel Red LED for each setpoint Power On/Sensor Failure Response: Green “Power On” LED turns Red if sensor fails. Up scale
drive on sensor failure is standard.
Response Time:
100 milliseconds. Hysteresis:
Internal adjustments provide deadband adjustment from ap­proximately 1-15% of range.
The X54-3402 is a dual channel RTD alarm trip
Contact Outputs: One set of normally open and closed contacts per setpoint. Contact Rating: standard relays = 0.6 amps at 125 vac or 110 vdc, 2 amps at
30 vdc, (resistive loads)
optional relays = 14 amps at 120 vac, 10 amps at 240 vac, 8
amps at 24 vdc (resistive load; meets international standards)
Isolation: 1,000 V between channels. Common Mode Voltage:
1000 volts peak AC maximum without damage.
Radio Frequency Effects:
< 0.4 mV (referred to input) + 0.2% of span (referred to out-
put) when exposed to 5W transmitter with frequency range 20-460 MHz at a distance of 1 m.
Ambient Temperature Range: Operating: -20 to 158
Storage: -40 to 158
Power Supply Range: 18 to 30 VDC.
(max. current in alarm state = 190 mA@ 24 vdc)
Terminals:
High temperature polyester type, wire size 12 AWG max., 10
amps max., 300 V max.
A Family of
Products!!!
Transmitters
Alarm Trips
I/I Isolators
° F (-25 to 70° C).
° F (-40 to 70° C).
Page 1 of 2
Specifications apply at 23 +/- 2°C (74 +/- 2°F) unless otherwise specified, and are subject to change without notice,
Ph: 800-327-6626 Fax: 818-992-6435 E-mail: sales@ronan.com Web: www.ronan.com
Rev. 0
X54-3402 Dual Channel Universal RTD Alarm Trip (continued)
TERMINAL ARRANGEMENT:
Outputs
B Setpt.
Ch1
A Setpt .
B Setpt.
Ch2
A Setpt .
18-30 vdc Power Input
J2*
J2*
NC
1
NO
2
C
3
NC
4 5
NO
6
C
J4*
NC
1
NO
2
C
3
NC
4
NO
5
C
6
1
+
2
-
3
GND
J5*
*
1.) Plug-in connector design simplifies installation and maintenance.
2.) Use up to 12 awg wiring.
3.) When inserted, case back cover provides a mechanical cover for connector screws (as required by European standards).
J1*
1 2 3 4 5 6
3-wire RTD
Ch1
Ch2
Inputs
MECHANICAL DETAIL:
2.47”
62.7mm
DIN Rail
2.23”
54.6mm
C
L
0.850”
21.6mm
5.80”
147.3mm
ORDERING INFORMATION:
X54-3402-(I) (II) - (I) (II)
Channel #2 Channel #1
I = RTD type (100 = 100 ohm Platinum 0.00385) (120 = 120 ohm Nickel) ( 10 = 10 ohm Copper @ 0°C) ( 9 = 10 ohm Copper @ 25°C) II = Standard Range code (A - G) or specify special range; e.g. 0-450°F = (0/450°F)
Example: Standard Ranges 0-500°F X54-3402-100E-100E
Example: Special Range 0-450°F X54-3402-100(0/450°F) -100(0/450°F)
Accessories:
D2-35X7.5 35 mm X 7.5 mm “U” style DIN rail, sold per foot
STANDARD INPUT RANGES:
Code
A
B -40 to +104
C
D 32 to +212
E
F 32 to +932
G
configured in the field or pre-configured at the factory to the customer’s specific RTD
ºF
-40 to +40
32 to +100
0 to +500
0 to +1500
Above ranges are standard offerings for
fastest delivery. Contact Ronan for price
and delivery of non-standard ranges.
These standard ranges can be re-
type and temperature range.
ºC
-40 to +4 100, 120
-40 to +40
0 to +38 100, 120,
0 to +100
-18 to +260 100, 120
0 to +500
-18 to +815 100
Sensor
Types
100, 120
10, 9
100, 120,
10, 9
100
Page 2 of 2
Ph: 800-327-6626 Fax: 818-992-6435 E-mail: sales@ronan.com Web: www.ronan.com
Rev. 0
Loading...