T/C, volt, mV, mA T r ansmitters - Field Configuratio n Options—DIN R ail Mounti ng
X54-3212 2-Wire (output loop powered) Dual Ch. Universal T/C, V, mV, mA Transmitter
High Density Dual Channel Packaging Field Configurable Options Including:
(6) T/C types, volt, mV or mA inputs + (7) std. input spans
with selectable zero offsets (for non-linearized ranges only)
Ideal for Dual Channel I-to-I Isolator Applications Max. Loop Load = 700 ohms at 24 vdc Loop Power Full Input/Output/Power and Channel Isolation
Standard 35 mm DIN Rail Mounting
DESCRIPTION: The X54-3212 is a dual channel transmitter
powered by the output 4-20 mA current loop. Features include: two piece plug-in connectors for easy wiring and maintenance; internal cold junction compensation for T/C inputs, field configurable input types and ranges; optional linearized outputs; full 1000 vac isolation; and front panel access to ZERO and SPAN adjustments. RFI protec­tion, wide operating temperature, and high accuracy are standard fea­tures. Custom inputs, outputs, scaling and linearization are available from the factory.
SPECIFICATIONS:
Inputs:
Thermocouple type E, J, K, T, R, S, or mV, volt, mA (linearized outputs available for thermocouples only)
Input Impedance:
T/C or mV > 100 M ohm; volts = >550 K ohm mA = 10 ohm
Outputs: 4-20 mA into 700 ohms with 24 vdc loop power
I.e.: Max Rload = (Vloop supply– 10 vdc) / 20 mA
Span Adjustment:
Front-accessible, multi-turn, infinite resolution potentiometer permits minimum +/- 5% adjustment.
Zero Adjustment:
Front-accessible, multi-turn, infinite resolution potentiometer permits minimum +/- 5% adjustment
Sensor Failure Response: Red front-panel LED with upscale drive or down scale drive
(mA input are down scale only)
Calibrated Accuracy: +/- 0.1% of span (linearization errors additional on large
span applications, consult factory )
Isolation: 1,000 vac between channels, input and output.
Specifications apply at 23 + /- 2°C (74 +/- 2°F) unless other wise specifi ed, and are subject to change without notice,
Common Mode Rejection: > 120 dB, DC at 60 Hz. Common Mode Voltage:
1000 volts peak AC maximum without damage.
Ambient Temperature Coefficient: Ambient temperature range: 32 to 158
Gain: < +/- 0.01 % / Zero: < +/- 0.005 % /
Ambient Temperature Range: Operating: -20 to 158°F (-25 to 70°C).
Storage: -40 to 158
Power Supply Range: 10 to 40 vdc (max. allowable at X54)
(reverse polarity protected)
Radio Frequency Ef fects:
< 0.4 mV (referred to input) + 0.2% of span (referred to out­put) when exposed to 5W transmitter with frequency range 20-460 MHz at a distance of meter.
Calibration: Typically, factory calibrated to customer specified ranges.
Customer configurable for non-linearized applications.
Terminals:
High temperature polyester type, wire size 12 AWG max., 10 A max., 300 V max.
A Family of
Products!!!
Transmitters
Alarm Trips
I/I Isolators
°F (0 to 70°C).
°F.
°F.
°F (-40 to 70°C).
Page 1 of 2
Ph: 800-327-6626 Fax: 661-295-6063 E-mail: sales@ronan.com Web: www.ronan.com
Rev. 1
X54-3212 Dual Channel Thermocouple T/C, volt, mV, mA Transmitter (continued)
TERMINAL ARRANGEMENT:
Outputs
Ch1
Ch2
NC= No Connection
J2*J2*
+
1
-
2
NC
3
+
4
-
5
NC
6
*
1.) Plug-in connector design simplifies installation and maintenance.
2.) Use up to 12 awg wiring.
3.) When inserted, case back cover provides a mechanical cover for connector screws (as required by European standards).
Thermocouple
J1*
+
1
-
2
NC
3
+
4
-
5
NC
6
or
MV, volt & mA
Inputs
1 2 3 4 5 6
+
-
NC
+
-
NC
Ch1
Ch2
Inputs
Ch1
Ch2
MECHANICAL DETAIL:
2.47”
62.7mm
DIN Rail
2.23”
54.6mm
C
L
0.850”
21.6mm
5.80”
147.3mm
ORDERING INFORMAT ION:
X54-3212-(I) (II) - (I) (II)
Channel #2 Channel #1
I = input type (E, J, K, R, S, or T) T/C (V) Volt or mV (I) milliamp II = Standard Range code (A - H) or specify special range; e.g. 0-750°F = (0/750)
or special range; e.g. 0-25 mvdc = (0/25mvdc)
Example: Std. Range 0-2500°F linearized for type K T/C X54-3212-KD-KD
Example: Special Range 0-750°F linearized for type J T/C X54-3212-JL(0/750°F) - JL(0/450°F) (add “L” after T/C type to request linearized output)
Accessories:
D2-35X7.5 35 mm X 7.5 mm “U” style DIN rail, sold per foot
STANDARD INPUT RANGES :
ºF or input
Code
A -450 to 0 -267 to -18 T, K, E B 0 to +750 -18 to +399 J, T
C 0 to +2100 -18 to +1149 J, E D 0 to +2500 -18 to +1371 K
E 0 to +3200 -18 to +1760 R, S F 4-20 mA
G H 1 - 5 vdc V
Above codes A-E are standard linearized T/C tem-
perature ranges for fastest delivery. Conta c t Ronan
for price and delivery of non-st an d ar d ran g es wit h or
without linearization. Codes F and H are also stan-
These transmitters can be configured in the field or
pre-configured at the factory to the customer’s spe-
cific input type and temperature range. Factory con-
figurat i on is onl y n ec essary if li n eari z at i on is re-
quired. Only the thermocouples inputs have
range
Not available
dards for faste st delivery.
the linearized output option.
ºC or input
range
Sensor/Input
Types
I
Page 2 of 2
Ph: 800-327-6626 Fax: 661-295-6063 E-mail: sales@ronan.com Web: www.ronan.com
Rev. 1