Ronan X54-3202 User Manual

ISO 9001
REGISTERED
RTD Transmitters - Field Configuration Options - High Density DIN Rail Packaging
X54-3202 2-Wire (output loop powered) Dual Channel Universal RTD Transmitter
High Density Dual Channel Packaging
Field Configurable Options Including:
four (4) RTD types, seven (7) standard input spans
with selectable zero offsets (for non-linearized ranges only)
Max. Loop Load = 700 ohms at 24 vdc Loop Power
Full Input/Output/Power and Channel Isolation
Front Access to Zero and Span Adjustments
Standard 35 mm DIN Rail Mounting
DESCRIPTION: The X54-3202 is a dual channel RTD transmit-
ter powered by the output 4-20 mA current loop. Features include: two piece plug-in connectors for easy wiring and maintenance; field configurable ranges and RTD types; optional linearized outputs; full 1000 vac isolation; and front panel access to ZERO and SPAN adjust­ments. RFI protection, wide operating temperature, and high accuracy are standard features. Custom inputs, outputs, scaling and linearization are available from the factory.
SPECIFICATIONS:
Input: RTD sensor types: 100 ohm platinum, 120 ohm nickel,
10 ohm copper. (linearized outputs available for Platinum or Nickel only)
Input Impedance:
> 100 K ohms.
Outputs: 4-20 mA into 700 ohms with 24 vdc loop power i.e.: Max. Rload = (Vloop supply - 10 vdc)/ 20 mA
Span Adjustment:
Front-accessible, multi-turn, infinite resolution potentiometer permits minimum +/- 5% adjustment.
Zero Adjustment:
Front-accessible, multi-turn, infinite resolution potentiometer permits minimum +/- 5% adjustment
Calibrated Accuracy: +/- 0.1% of span (linearization errors additional on large
span applications, consult factory )
Isolation: 1,000 vac between channels, input and output.
Input and output circuits isolated by transformers.
Common Mode Rejection:
> 120 dB, DC at 60 Hz.
Specifications apply at 23 +/- 2°C (74 +/- 2°F) unless otherwise specified, and are subject to change without notice,
Common Mode Voltage:
1000 volts peak AC maximum without damage.
Ambient Temperature Coefficient: Ambient temperature range: 32 to 158
Gain: < +/- 0.01 % / Zero: < +/- 0.01 % /
Ambient Temperature Range: Operating: -20 to 158°F (-25 to 70°C).
Storage: -40 to 158
Power Supply Range: 10 to 40 vdc (max. allowable at X54)
(reverse polarity protected)
Radio Frequency Effects:
< 0.4 mV (referred to input) + 0.2% of span (referred to out­put) when exposed to 5W transmitter with frequency range 20-460 MHz at a distance of 1 m.
Calibration: Typically, factory calibrated to customer specified ranges.
Customer configurable for non-linearized applications.
Terminals:
High temperature polyester type, wire size 12 AWG max., 10 A max., 300 V max.
A Family of
Products!!!
Transmitters
Alarm Trips
I/I Isolators
°F (0 to 70°C). °F. °F.
°F ( -40 to 70°C).
Page 1 of 2
Ph: 800-327-6626 Fax: 818-992-6435 E-mail: sales@ronan.com Web: www.ronan.com
Rev. 0
X54-3202 2-Wire (loop powered) Dual Ch. Universal RTD Transmitter (continued)
TERMINAL ARRANGEMENT:
Outputs
Ch1
Ch2
J2*J2* J1*
+
1
-
2
NC
3
+
4
-
5 6
NC
*
1.) Plug-in connector design simplifies installation and maintenance.
2.) Use up to 12 awg wiring.
3.) When inserted, case back cover provides a mechanical cover for connector screws (as required by European standards).
3-wire RTD
1 2 3 4 5 6
Inputs
Ch1
Ch2
MECHANICAL DETAIL:
2.47”
62.7mm
DIN Rail
2.23”
54.6mm
C
L
0.850”
21.6mm
5.80”
147.3mm
ORDERING INFORMATION:
X54-3202-(I) (II) - (I) (II)
Channel #2 Channel #1
I = RTD type (100 = 100 ohm Platinum 0.00385) ( 1 2 0 = 1 2 0 o h m N i c k e l ) ( 1 0 = 1 0 o h m C o p p e r @ 0 ° C ) ( 9 = 10 ohm Copper @ 25°C) II = Standard Range code (A - G) or specify special range; e.g. 0-450°F linearized = (0/450°F)
Example: Standard Ranges 0-500°F linearized X 5 4 - 3 2 0 2 - 1 0 0 E - 1 0 0 E
Example: Special Range 0-450°F linearized X54-3202-100L(0/450°F) - 100L(0/450°F)
(add “L” after RTD type to request linearized output)
Accessories:
D2-35X7.5 35 mm X 7.5 mm “U” style DIN rail, sold per foot
STANDARD INPUT RANGES:
Code
A -40 to +40 -40 to +4 100, 120
B -40 to +104 -40 to +40 100, 120
C 32 to +100 0 to +38 100, 120,
D 32 to +212 0 to +100 100, 120,
E 0 to +500 -18 to +260 100, 120
F 32 to +932 0 to +500 100
G 0 to +1500 -18 to +815 100
Above ranges are standard offerings for fastest deliv-
ery, and they are linearized for Platinum and Nickel RTDs only. Contact Ronan for price and delivery of
non-standard ranges with or without linearization.
These transmitters can be configured in the field or pre-configured at the factory to the customer’s spe­cific RTD type and temperature range. Factory con-
figuration is only necessary if linearization is re-
quired. Only the Platinum and Nickel RTDs hav e
ºF
the linearized output option.
ºC
Sensor
Types
10, 9
10, 9
Page 2 of 2
Ph: 800-327-6626 Fax: 818-992-6435 E-mail: sales@ronan.com Web: www.ronan.com
Rev. 0
Loading...