Description:
RLL is a Ronan Engineering term that stands for “Radiation Low Level.” RLL Technology utilizes up to a total of 0.9 mCi (0.033 GBq) of cesium 137 capsules. The RLL-1 utilizes from one to ten 0.09 mCi (0.003 GBq) cesium 137 capsules, while the RLL-A utilizes a single 0.9 mCi (0.033 GBq) cesium 137 capsule. The RLL-2 is a strip source with up to a total of 100 µCi ( 0.004 GBq) cesium 137. RLL designs are not required to have shutters.
Source Holder:
Construction: Carbon Steel (Stainless Steel Available) With
Weight: RLL-1, 1A Approximately 20 lbs (9 kg)
SPECIFICATIONS
Lead, or Tungsten Shielding Surrounding A Doubly Encapsulated, Heliarc-Welded Stainless Steel Source Capsule. A Lead-Free Option Is Available, Dependant On Isotope Activity
RLL-2 Approximately 1 lb (0.5 kg)
Paint: Protective Coating-Epoxy Based (Grey as
Standard, Customer Specified Colors Available)
Temperature Limit: Standard Option, 455 Degrees F. (235 Degrees C), Fire Resistant Option, 800°C/ 20 min
Collimation: Beam Pattern up to 45 Degrees. (Dependant Upon
Application)
Maximum Source Size: RLL-1: Multiple Capsules up to 0.9 mCi (0.033 GBq) CS-137 Multiple Capsules up to 0.2 mCi (0.007 GBq) Co-60
RLL-1A: Single Capsule up to 0.09 mCi ( 0.003 GBq)CS-137 Single Capsule up to 0.01 mCi Co-60
RLL-2: Strip Source with Multiple Capsules up to 100 µCi (0.004 GBq) CS-137
Radiation Fields: 0.5 mrem/hr @ 12" (at maximum source size)
Ronan Measurements Division · 8050 Production Drive Florence, KY 41042
Web: www.ronanmeasure.com · E-Mail: ronan@ronanmeasure.com
(859) 342-8500 · FAX (859) 342-6426