Chip Tantalum capacitors
(Bottom surface electrode type : Large capacitance)
TCT Series PL Case
Features (PL) Dimensions (Unit : mm)
1) Vital for all hybrid integrated circuits
board application.
2) Wide capacitance range.
3) Screening by thermal shock.
Part No. Explanation
Anode mark
H
L
SS
(Unit : mm)
Dimensions
W
1
W
2
L
1
W
2
W
H
S
PL case
2.0
1.25
0.85
0.9
0.5
±
0.2
±
0.2
±
0.2
±
0.1
±
0.2
11
Series name
TCT
Case style
2
PL
Rated voltage
3
Rated voltage (
CODE
M0 J 8 RT T 4 7 6C P L
2
3 641
Nominal capacitance
4
Nominal capacitance in pF in 3 digits:
2 significant figures followed by the figure
representing the number of 0's.
5
Capacitance tolerance
+
M :
20%
−
4
6.30J101A161C20 35
2.5
V)
0G
0E
25
1D 1V
1E
6
Taping
Reel width : 8mm
8 :
Positive electrode on the side opposite to sprocket hole
R :
5
www.rohm.com
1/6
c
2011 ROHM Co., Ltd. All rights reserved.
○
2011.12 - Rev.H
TCT Series PL Case
Rated table
(μF)
42.5
1.0 (105)
1.5 (155)
2.2 (225)
3.3 (335)
4.7 (475)
6.8 (685)
10 (106)
15 (156)
22 (226)
33 (336)
47 (476)
68 (686)
100 (107)
150 (157)
Remark) Case size codes (PL) in the above show products line-up.
Under development
∗
∗
∗
∗
PL
PL
PL
PL
PL
Marking
The indications listed below should be given on the surface of a capacitor.
(1) Polarity
(2) Rated DC voltage
(3) Capacitance value
: The polarity should be shown by bar. (on the anode side)
: Due to the small size of PL case, a voltage code is used as shown below.
: Due to the small size of PL case,a capacitance code is used as shown below.
Rated voltage (V,DC)
6.3 10 16 20 35
∗
PL
PL
∗
PL
PL
PL
PL
∗
PL
PL
PLPL
Data Sheet
25
PL
∗
PL
PL
Voltage
Code
e 2.5
g
j
A
C
D
E
V
[PL case] note 1)
(1)voltage code (2)capacitance code
Rated DC
Voltage (V)
4
6.3
10
16
20
25
35
−
(1)
j
Capacitance
n
−
(2)
Code
Nominal
Capacitance (μF)
A 1.0
E 1.5
J 2.2
N 3.3
S
W
a
e
j
n
s47
w68
e
j n
4.7
6.8
10
15
22
33
100a
150
note 2) voltage code and capacitance code are variable with parts number
manufacture code
www.rohm.com
2/6
c
2011 ROHM Co., Ltd. All rights reserved.
○
2011.12 - Rev.H
TCT Series PL Case
Characteristics
+125
±20%
of initial value
Performance
°C
35
22
44
Item
Operating Temperature −55
Maximum operating
temperature with no voltage
derating
Rated voltage (VDC) 20 2516106.34
Category voltage (VDC) 13 16106.342.5
Surge voltage (VDC) 1385.2
DC Leakage current Shall be satisfied the voltage on
Capacitance tolerance
Tangent of loss angle
(Df, tan δ)
Impedance
Resistance to
Soldering heat
Appearance
L.C.
ΔC / C
Df (tan δ)
°C to
+85
°C
2.5
1.6
3.2 2620 32
" Standard list "
Shall be satisfied allowance range.
±
20%
Shall be satisfied the voltage on
" Standard list "
Shall be satisfied the voltage on
" Standard list "
There should be no significant abnormality.
The indications should be clear.
Less than initial limit
Within
Less than 200% of initial limit
Data Sheet
Test conditions (based on JIS C 5101−1 and JIS C 5101−3)
85
Voltage reduction when temperature exceeds +
at 85
°C
at 125
°C
at 85
°C
As per 4.9 JIS C 5101-1
As per 4.5.1 JIS C 5101-3
Voltage : Rated voltage for 5min
As per 4.7 JIS C 5101-1
As per 4.5.2 JIS C 5101-3
Measuring frequency : 120
Measuring voltage : 0.5Vrms +1.5 to 2V.DC
Measuring circuit
As per 4.8 JIS C 5101-1
As per 4.5.3 JIS C 5101-3
Measuring frequency : 120
Measuring voltage : 0.5Vrms +1.5 to 2V.DC
Measuring circuit
As per 4.10 JIS C 5101-1
As per 4.5.4 JIS C 5101-3
Measuring frequency : 100
Measuring voltage : 0.5Vrms or less
Measuring circuit
As per 4.14 JIS C 5101-1
As per 4.6 JIS C 5101-3
Dip in the solder bath
Solder temp : 260
Duration : 5±0.5s
Repetition
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
: 1
±
12Hz
: DC Equivalent series circuit
±
12Hz
: DC Equivalent series circuit
±
10kHz
: DC Equivalent series circuit
±
5
°C
°C
Temperature
cycle
Moisture
resistance
Appearance
L.C.
ΔC / C
Df (tan δ)
Appearance
L.C.
ΔC / C
Df (tan δ)
There should be no significant abnormality.
The indications should be clear.
Less than 200% of initial limit
Within
±20%
of initial value
Less than 200% of initial limit
There should be no significant abnormality.
The indications should be clear.
Less than 200% of initial limit
Within
±20%
of initial value
Less than 200% of initial limit
As per 4.16 JIS C 5101-1
As per 4.10 JIS C 5101-3
Repetition : 5 cycles
(1 cycle : steps 1 to 4) without discontinuation.
Temp. Time
1
2
3
4
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
As per 4.22 JIS C 5101-1
As per 4.12 JIS C 5101-3
After leaving the sample under such atmospheric
condition that the temperature and humidity are
60±2°C and 90 to 95% RH, respectiveiy, for 500±12h
leave it at room
temperature for over 24h and then measure the
sample.
−
Room temp.
+
125 2°C
−
Room temp.
+
−55 3°C
30±3min.
3min. or less
30±3min.
3min. or less
www.rohm.com
3/6
c
2011 ROHM Co., Ltd. All rights reserved.
○
2011.12 - Rev.H