Rockwell Automation 800F-AMEGY User Manual

EMO Switch Guard
)
)
)
)
)
)
)
)
(
)
)
)
(
)
)
)
(
)
)
)
(
)
)
)
(
)
)
)
(
)
)
)
(
)
)
)
p
g
g
(Cat _-AMEGY)
WARNING
To prevent electrical shock, disconnect from power source before installing or servicing.
ATTENTION
Read this instruction sheet carefully before using the switch guard. This EMO guard is designed for use on semiconductor manufacturing equipment and is SEMI S2 compliant when properly installed per SEMI S2 0706.
Installation
NEMA: For use on a flat surface of a Type 4x indoor use only or Type 13 enclosure. IEC:IP66
_-ATW1
EMO
41063-311-01
DIR 41063-311 (Version 03)
Printed in China
(1 - 7.7 mm) 3/64 - 19/64 in.
Mountin
1638 mm(64.5 in 1524 mm(60.0 in 1422 mm (56.0 in) 1321 mm (52.0 in) 1219 mm (49.0 in) 1118 mm (44.0 in) 1016 mm (40.0 in)
An E-Stop has to be within 10 feet or 3 m of every operation and maintenance location. The location of the E-Sto
Dimensions per SEMI S8 Ergonomic Requirements for reach of critical controls:
Height from floor Corresponding Depth
914 mm (36.0 in) 838 mm (33.0 in)
Workstation
(from leading edge of
workstation)
254 mm(10.0 in 368 mm(14.5 in 432 mm 470 mm 483 mm 470 mm 394 mm 292 mm 178 mm
17.0 in
18.5 in
19.0 in
18.5 in
15.5 in
11.5 in
7.0 in
could not be obstructed and must be easily visible.
Height from floor
1397 mm(55.0 in 1270 mm(50.0 in 1168 mm(46.0 in 1067 mm(42.0 in
965 mm(38.0 in 864 mm(34.0 in 762 mm(30.0 in 660 mm(26.0 in 533 mm(21.0 in
Seated WorkstationStandin
Corresponding Depth (from leading edge of
workstation)
366 mm(14.5 in 432 mm(17.0 in 470 mm(18.5 in 483 mm(19.0 in 483 mm(19.0 in 470 mm(18.5 in 445 mm(17.5 in 381 mm(15.0 in 254 mm(10.0 in