Robustel EG8001 Installation Quick Manual

Page 1
- 1 -
Installation and Configuration Quick Guide
EG8001
Industrial Elevator Gateway
2xEth + 1xVoice + 2xRS-232 + 1xRS-485 + 1xConsole + 1xUSB Host
Environmental Requirements
Power input: 9 to 36V DC
Power consumption: 100 mA@12 V in idle state, 400 mA (peak) @12 V in communication state Operating temperature: -40 °C to 75 °C Relative humidity: 5% to 95% RH
Package Contents
Optional Accessories (sold separately)
SMA cellular antenna (3G/4G) magnet antenna 35 mm DIN rail mounting kit
Power cable Serial cable
Audio cable
Before installing the EG8001 Gateway, verify the kit contents as following.
1 x Robustel EG8001 gateway 1 x 2-pin 3.81mm pluggable terminal block for power
*If any of the above items is missing or damaged, please contact your Robustel sales representative.
Page 2
- 2 -
Hardware Introduction
1.
Overview
2.
Dimensions
3. Pinouts
XRS4 (Debug)
PIN
Function
Direction
1
RX
Device EG9012
2
TX
EG9012Device
3
GND
--
XIT (FXS)
PIN
Function
Direction
1
RING
Device EG9012
2
--
3
TIP
EG9012Device
XPW (Power supply interface)
PIN
Function
Direction
1
V+
Adapter EG8001
2
V-
EG8001Adapter
XRS1/XRS2 (RS232 serial port)
PIN
Function
Direction
1
RX
Device EG8001
2
TX
EG8001Device
3
GND
--
XRS3 (RS485 serial port)
PIN
Function
Direction
1
GND
-- 2 A
-- 3 B
--
Page 3
- 3 -
4. LED Indicators
Name
Color
Status
Description
RUN
Green
On
Gateway is running
DEV1
Green
On
Connected to controller1
DEV2
Green
On
Connected to controller2
NET
Green
Always On
Connected to 4G network
Blinking every 100ms
Connected to 3G network
Blinking every 1s
Connected to 2G network
RSSI
Green
Blinking every 1s
Signal level: 0-9 (Low Signal)
Blinking every 100ms
Signal level: 10-19 (Medium Signal)
Always on
Signal level: 20-31 (High Signal)
Off
No signal
DC
Green
On
Connected to the Data Center
ERR
Green
On
Gateway in fault
5. USB Interface
Function
Operation
Firmware
upgrade
USB interface is used for batch firmware upgrading, but cannot be
used for sending or receiving data from slave devices which
connected to it. You can insert a USB storage device into the
routers USB interface, such as a U disk or a hard disk. If there have
a supported configuration file or a EG8001 firmware in this USB
storage device, the EG8001 router will automatically update the
configuration file or the firmware.
6. Ethernet Ports
Each Ethernet port has two LED indicators (please check the picture above). The yellow one is Speed indicator and the green one is Link indicator. There are three status of each indicator. For details please refer to the form below.
Indicator
Status
Description
Speed Indicator
Off
10 Mbps mode.
On
100 Mbps mode.
Link Indicator
Off
Connection is down.
On
Connection is up.
Blink
Data is being transmitted
Page 4
- 4 -
Hardware Installation
1. Insert or Remove SIM Card
2. Attach External Antenna (SMA Type)
Attach an external SMA antenna to the gateway’s connector and twist tightly. Make sure the antenna is within the correct frequency range provided by the ISP and with 50 Ohm impedance. Note: Recommended torque for tightening is 0.35 N.m.
Inserting SIM Card
1. Power off the gateway.
2. Use a pointed stick to press the Push Button, and then take out the
SIM Card Tray.
3. Place the SIM card on the tray, and insert them to the slot until you
hear “a cracking sound”.
Removing SIM card
1. Power off the gateway.
2. Press the Push Button, and the tray with SIM card will pop up to be
pulled out.
Note:
1. Don’t touch the metal surface of the SIM card in case information
in the card is lost or destroyed.
2. Don’t bend or scratch your SIM card. Keep the card away from
electricity and magnetism.
3. Make sure to disconnect the power source from your gateway
before inserting and removing your SIM card.
Page 5
- 5 -
3.
Mount the Gateway
Use 3 pcs of M3*6 flat head Phillips screws to fix the DIN rail to the gateway, and then hang the DIN rail on the mounting bracket. It is
necessary to choose a standard bracket.
Note: Recommended torque for mounting is 1.0 N.m, and the maximum allowed is 1.2 N.m.
4.
Ground the Gateway
Gateway grounding helps prevent the noise effect due to
electromagnetic interference (EMI). Connect the gateway to the site
ground wire by the ground screw before powering on. Note: This product is appropriate to be mounted on a sound grounded
device surface, such as a metal panel.
5. Connect the Gateway to a Computer
Connect an Ethernet cable to ETH0 or ETH1 at the bottom of the EG8001, and connect the other end of the cable to your computer.
6. Power Supply
EG8001 Gateway supports reverse polarity protection, but always refers to the figure above to connect the power adapter correctly. Note: The range of power voltage is 9 to 36V DC.
Page 6
- 6 -
Configure the PC
There are two methods to get IP address for the PC, one is to obtain an IP address automatically from Local Area Connection”, and another is to configure a
static IP address manually within the same subnet of the Gateway. Please refer to the steps below.
Here take Windows 7 as example, and the configuration for windows system is similar.
2. Click Properties in the window of Local Area
Connection Status.
1. Click Start > Control panel, double-click Network
and Sharing Center, and then double-click Local
Area Connection.
3. Choose Internet Protocol Version 4
(TCP/IPv4) and click Properties.
4. Two ways for configuring the IP
address of PC
Obtain an IP address automatically:
Use the following IP address:
(Configured a static IP address manually within the
same subnet of EG8001 Gateway)
5. Click OK to finish the configuration.
Page 7
- 7 -
Configure the Gateway
1.
Log in the Gateway
To log in to the management page and view the configuration status of
your Gateway, please follow the steps below:
1. On the PC, open a web browser such as Internet Explorer, Google
and Firefox etc.
2. From your web browser, type the IP address of the Gateway into the address bar and press enter. The default IP address of EG8001 Gateway is 192.168.0.1, though the actual address may vary
3. In the login page, enter the username and password, choose language and then click LOGIN.
Note: If enter the wrong username or password over six times, the login web will be locked for 5 minutes.
4. After logging in, the home page of the EG8001 Gateway’s web interface is displayed, for example.
Note: To configure parameters should follow this order modify parameter 1 > Submit > modify parameter 2 > Submit > Save & Apply.
2. Check the Cellular Connection Status
Click Interface > Cellular > Status to view the connection status.
Click the row of status, the details status information will be displayed under the row.
Page 8
- 8 -
3. Configure the IP of the Gateway
There are two Ethernet ports on EG8001 Gateway, including ETH0 and ETH1. The ETH0 and ETH1 can freely choose from lan0~lan1, but at least one LAN port must be assigned as lan0. In another word, ETH0+ETH1 can be configured as lan0+lan0, lan0+lan1, or lan1+lan0. Both of ETH0 and ETH1 default to lan0, and their default IP are 192.168.0.1/255.255.255.0.
Configure lan0
Click Interface > LAN > LAN, click lan0s edit button to configure its configuration, and modify its IPv4 address and Netmask.
Click lan0s edit button and configure its parameters in the pop up window.
When finished, click Submit > Save & Apply for the configuration to take effect.
Configure lan1
Click Interface > Ethernet > Ports, click eth1’s edit button, choose lan1 as the assigned port, and click Submit”. Note: By default, there is a LAN port (lan0) in the list. To begin adding a new LAN port (lan1), please configure eth0 or eth1 as lan1 first in Ethernet > Ports > Port Settings. Otherwise, the operation will be prompted as “List is full”.
Click Interface > LAN in the homepage, and click the add button.
Page 9
- 9 -
Choose lan1 as the interface, and configure its IPv4 address and Netmask.
When finished, click Submit > Save & Apply for the configuration to take effect.
Guangzhou Robustel Technologies Co., Ltd
Address: 3rd Floor, Building F, Kehui Park, No.95 Daguan Road, Guangzhou, China 510660 Tel: 086-20-29019902
Email: info@robustel.com
Configure Multiple IP
Click Interface > LAN > Multiple IP, and click the edit button of lan0.
Note: You may click to edit the multiple IP of the LAN port, or click to delete the multiple IP of the LAN port. Now, click to add a multiple IP to the LAN port.
When finished, click Submit > Save & Apply for the configuration to take effect.
Loading...