CHEMICAL SANITIZING GLASSWASHER DISHMACHINE SERIES
INSTALLATION & OPERATION MANUAL
FOR JACKSON MODELS:
R24
R30
July 31, 2006
P/N 7610-002-24-71 (Revision E)
HIGHWAY 25E
www.jacksonmsc.com
DEFECTS IN MATERIAL OR WORKMANSHIP, UNDER NORMAL USE AND OPERATION FOR A PERIOD OF (1) ONE
YEAR FROM THE DATE OF PURCHASE, BUT IN NO EVENT TO EXCEED (18) EIGHTEEN MONTHS FROM THE DATE
Jackson MSC agrees under this warranty to repair or replace , at its discretion, any original part which fails under normal use due to faulty
tained and operated in accordance with the applicable factory instruction manual furnished with the machine and the failure is reported to
the authorized service agency within the warranty period. This includes the use of factory specified genuine replacement parts, purchased
The labor to repair or replace such failed part will be paid by Jackson MSC, within the continental United States, Hawaii and Canada, during
the warranty period provided a Jackson MSC authorized service agency, or those having prior authorization from the factory, performs the
service. Any repair work by persons other than a Jackson MSC authorized service agency is the sole responsibility of the customer. Labor
es, pressure regulators, pre rinse units, etc. that are shipped with the unit and installed at the site are included. Labor to repair or replace
thorized persons, improper installation, if serial number has been removed or altered, or if unit is used for purpose other than it was origi
Jackson MSC limits warranty travel time to (2) two hours and mileage to (100) one hundred miles. Jackson MSC will not pay for travel time
Jackson replacement parts are warranted for a period of 90 days from the date of installation or 180 days from the date of shipment from the
THERE ARE NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING FOR FITNESS OR MERCHANTABILITY, THAT ARE NOT SET
LIABLE FOR ANY LOSS OR DAMAGE, DIRECT OR CONSEQUENTIAL, OR FOR THE DAMAGES IN THE NATURE OF PENALTIES,
ers at anytime. Nor does it cover adjustments such as, but not limited to timer cams, thermostats or doors, beyond 30 days from the date
of installation. In addition, the warranty will only cover the replacement of wear items such as curtains, drain balls, door guides or gaskets
during the first 30 days after installation. Also, not covered are conditions caused by the use of incorrect (non-Commercial) grade detergents,
MANUFACTURERS WARRANTY
ONE YEAR LIMITED PARTS & LABOR WARRANTY
ALL NEW JACKSON DISHWASHERS ARE WARRANTED TO THE ORIGINAL PURCHASER TO BE FREE FROM
OF SHIPMENT FROM THE FACTORY.
material or workmanship during the warranty period, providing the equipment has been unaltered, and has been properly installed, main
directly from a Jackson authorized parts distributor or service agency. Use of generic replacement parts may create a hazard and void war
ranty certification.
coverage is limited to regular hourly rates, overtime premiums and emergency service charges will not be paid by Jackson MSC.
Accessory components not installed by the factory carry a (1) one year parts warranty only. Accessory components such as table limit switch
these components is not covered by Jackson MSC.
This warranty is void if failure is a direct result from shipping, handling, fire, water, accident, misuse, acts of god, attempted repair by unau
nally intended.
TRAVEL LIMITATIONS
and mileage that exceeds this, or any fees such as those for air or boat travel without prior authorization.
WARRANTY REGISTRATION CARD
The warranty registration card supplied with the machine must be returned to Jackson MSC within 30 days to validate the warranty.
REPLACEMENT PARTS WARRANTY
factory, which ever occurs first.
PRODUCT CHANGES AND UPDATES
Jackson MSC reserves the right to make changes in design and specification of any equipment as engineering or necessity requires.
THIS IS THE ENTIRE AND ONLY WARRANTY OF JACKSON MSC. JACKSON’S LIABILITY ON ANY CLAIM OF ANY KIND, INCLUDING
NEGLIGENCE, WITH RESPECT TO THE GOODS OR SERVICES COVERED HEREUNDER, SHALL IN NO CASE EXCEED THE PRICE
OF THE GOODS OR SERVICES OR PART THEREOF WHICH GIVES RISE TO THE CLAIM.
FORTH HEREIN, OR THAT EXTEND BEYOND THE DURATION HEREOF. UNDER NO CIRCUMSTANCES WILL JACKSON MSC BE
ARISING OUT OF THE USE OR INABILITY TO USE ANY OF ITS PRODUCTS.
ITEMS NOT COVERED
This warranty does not cover cleaning or deliming of the unit or any component such as, but not limited to, wash arms, rinse arms or strain
incorrect water temperature or pressure, or hard water conditions.
ARRET!
CALL 1-888-800-5672 TO REGISTER THIS PRODUCT!
LLAME AL 1-888-800-5672 PARA REGISTRAR ESTE PRODUCTO!
S.V.P. APPELER 1-888-800-5672 POUR ENREGISTRER CE PRODUIT,
LA GARANTIE SERA ANNULEE POUR TOUT PRODUIT NON- ENREGISTREE
FAILURE TO DO SO WILL VOID THE WARRANTY!
AL NO HACERLO LA GARANTIA SERA ANULADA!
REVISION
D 03-03-04 CBW N/A Converted over to new layout. Added 2nd Enodis logo.
REVISION
DATE
MADEBYAPPLICABLE
ECN
DETAILS
E 07-31-06 MAW 7751
Converted to center layout. Updated schematic. Added new
logos. Added register product page.
i
NOMENCLATURE FOR THE MODELS COVERED IN THIS MANUAL
GLASSWASHER SERIES
R24 = 24” Glasswasher
R30 = 30” Glasswasher
Model:
Serial No.:
Installation Date:
Service Rep. Name:
Phone No.:
ii
TABLE OF CONTENTS
SECTION DESCRIPTION PAGE
I. GENERAL
Specifications 2
Dimensions 3
II. INSTRUCTIONS SECTION
Installation Instructions 5
Electrical Connections 6
Detergent Control 7
Chemical Dispensing 8
Operating Instructions 9
Sequence of Operation 10
III. PREVENTATIVE MAINTENANCE 12
IV. ELECTRICAL DIAGRAM
R24 & R30 208-230 Volt, 60 Hertz, Single Phase 14
V. JACKSON MAINTENANCE & REPAIR CENTERS 16
iii
SECTION 1:
SPECIFICATION INFORMATION
1
SECTION 1: SPECIFICATION INFORMATION
SPECIFICATIONS
R24
OPERATING CAPACITY (RACKS/HOUR)
GLASSES PER HOUR 1200
OPERATING CYCLE (SECONDS)
TOTAL CYCLE TIME 120
TANK CAPACITY (GALLONS) 3.0
WASH PUMP CAPACITY
WASH PUMP 55 GPM
TEMPERATURES
WASH---°F (MINIMUM) 130
RINSE---°F (MINIMUM) 75
ELECTRICAL REQUIREMENTS
WASH PUMP MOTOR HORSEPOWER 3/4
NOTE: Typical Electrical Circuit is based upon (1) 125% of
the full amperage load of the machine and (2) typical
fixed-trip circuit breaker sizes as listed in the NEC 2002
Edition. Local codes may require more stringent protec tion than what is displayed here. Always verify with your
electrical service contractor that your circuit protection is
adequate and meets all applicable national and local
codes. These numbers are provided in this manual sim ply for reference and may change without notice at any
given time.
R30
OPERATING CAPACITY (RACKS/HOUR)
GLASSES PER HOUR” 1800
OPERATING CYCLE(SECONDS)
TOTAL CYCLE TIME 120
TANK CAPACITY (GALLONS) 4.14
WASH PUMP CAPACITY
WASH PUMP 55 GPM
TEMPERATURES
WASH---°F (MINIMUM) 130
RINSE---°F (MINIMUM) 75
ELECTRICAL REQUIREMENTS
WASH PUMP MOTOR HORSEPOWER 3/4
NOTE: Typical Electrical Circuit is based upon (1) 125% of
the full amperage load of the machine and (2) typical
fixed-trip circuit breaker sizes as listed in the NEC 2002
Edition. Local codes may require more stringent protection than what is displayed here. Always verify with your
electrical service contractor that your circuit protection is
adequate and meets all applicable national and local
codes. These numbers are provided in this manual sim ply for reference and may change without notice at any
given time.
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
VOLTS PH HZ RATINGS AMPS CIRCUIT
208 1 60 220V/3KW 20 25 AMP
230 1 60 220V/3KW 18 25 AMP
WATER REQUIREMENTS
INLET TEMPERATURE 130°F
GALLONS PER HOUR 10.0
WATER LINE SIZE NPT (Minimum) 1/2”
DRAIN LINE SIZE NPT (Minimum) 2”
FLOW PRESSURE P.S.I. 20A5
MINIMUM CHLORINE REQUIRED (PPM) 50
MINIMUM IODIPHOR REQUIRED (PPM) 12.5
NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided
on this page is for reference only and may be subject to
change without notice.
R24/R30 Installation & Operation Manual 07610-002-24-71
Issued: 07-31-2006 Revised: N/A
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
VOLTS PH HZ RATINGS AMPS CIRCUIT
208 1 60 220V/3KW 20 25 AMP
230 1 60 220V/3KW 18 25 AMP
WATER REQUIREMENTS
INLET TEMPERATURE 130°F
GALLONS PER HOUR 10.0
WATER LINE SIZE NPT (Minimum) 1/2”
DRAIN LINE SIZE NPT (Minimum) 2”
FLOW PRESSURE P.S.I. 20A5
MINIMUM CHLORINE REQUIRED (PPM) 50
MINIMUM IODIPHOR REQUIRED (PPM) 12.5
NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided
on this page is for reference only and may be subject to
change without notice.
2
LEGEND:
SECTION 1: SPECIFICATION INFORMATION
DIMENSIONS
A - WATER INLET 1/2” IPS (COLD)
B - WATER INLET 1/2” IPS (HOT)
C - DRAIN 2” NOMINAL
D - STANDARD WALL CLEARANCE: 2”
LETTER R24 R30
E 26-1/4" 30-5/16"
F 25-1/4" 30-1/2"
G 14-3/4" 16-1/4"
H 7-1/2" 8-5/8"
I 18-11/16" 23-11/16"
E
F
G
H
I
R24/R30 Installation & Operation Manual 07610-002-24-71
Issued: 07-31-2006 Revised: N/A
3