ITEM Parallel Blade
Rectangular Damper
POWER REQUIREMENTS 24 VAC actuator
AMBIENT RATINGS 0˚F to 120˚F (-18˚C to 49˚C)
LEAKAGE Low leakage damper
STATIC PRESSURE RATING 1.2” WG
DIMENSIONS 6” wide x 6” high to 36” wide x
36” high (15 cm wide x 15 cm high
to 91 cm wide x 91 cm high)
WEIGHT 3 lb. to 27.5 lb. (1.4 kg to 27.5 kg)
WIRING #18 gauge thermostat wire
ACTUATORS 2-wire, 2 position, spring return
(55 in-oz)
3-wire, 2 position, power open-power
closed (150 in-oz)
FRAME 6063 T5 extruded aluminum
4” channel frame
BLADES 4” wide 6063 T5 extruded aluminum
airfoil design
6” wide 6063 T5 extruded aluminum
airfoil design
PIVOT PINS 1/2” diameter octagonal extruded
aluminum
LINKAGE Concealed side linkage
BEARINGS Nylon
MOUNTING PLATE 18-gauge galvanized steel mounting
plate 6” wide
ROBERTSHAW PANELS
• Classic panel: up to 2 zones 2701-006
up to 3 zones 2701-001
• Deluxe panel: up to 7 zones 2701-002
• Premier panel: up to 19 zones 2702-001
ROBERTSHAW DAMPERS
• Rectangular motorized zone dampers
• Round motorized zone dampers
• Bypass non-electric zone dampers
ROBERTSHAW THERMOSTATS
• Programmable thermostats
• Digital non-programmable thermostats
• Mechanical thermostats
Design Specifications
Robertshaw®Zone
Control Systems
Distributed by:
PARALLEL BLADE
RECTANGULAR
ZONE DAMPERS
ORDER NUMBER Ex. DAOP0820E2
TYPE Parallel Blade
Rectangular Damper
NON-ACTUATOR SIDE 08 (6” to 36”)
ACTUATOR SIDE 20 (6” to 36”)
ACTUATOR TYPE E2 (2-wire control)
E3 (3-wire control)
FAIL SAFE Blank (normally open)
NC (normally closed)
Ordering Information
•
•
•
•
•
•
•
•
Climate Controls Americas
515 South Promenade Avenue
Corona California 92879-1736 USA
Telephone +1 800 951 5526 Facsimile +1 630 260 7299
iccacustomerservice@invensys.com
Technical Service Telephone +1 800 445 8299
Technical Service Facsimile +1 630 260 7243
technicalservice@invensys.com
www.icca.invensys.com
©2004 Climate Controls Americas 6/04 - #150-1577C