Robertshaw 9851i, 9865i, 9870i, DELUXE 9851i, DELUXE 9865i Quick Start Installation Manual

...
Models 9851i, 9865i and 9870i
Quick Start Installation Manual
111-340
Installation DOs and DON’Ts
DO
Shut off all power to system before installing.
Read entire manual before installing.
national and local codes.
DO NOT
Install on voltages greater than 30 VAC.
Short jumper across terminals on the gas
valve or at the system control.
Connect ground to any terminal in
this unit.
Install on outside walls or in direct sunlight.
Select location for installation.
1
Mark mounting hole locations on wall.
3
Drill 3/16” holes at marked locations on wall. Insert plastic anchors into holes.
4
Align unit base over plastic anchors embedded in wall and secure with the screws provided.
5
Connect wiring between unit and furnace. For Model 9851i (1H/1C furnace applications):
6
1- 1/2"
1"
Cut out
opening
1/4"
a
b
Mark mounting hole locations on wall using unit base as template.
Drill 3/16" holes
a
b
Press anchors into holes until flush.
Y1
R
C
E/W1
H O B G
Furnace
Terminals*
Wiring
Thermostat
C - Common 24 VAC R - System transformer Y1 - 1st stage cooling W1- 1st stage heating W2- not used Y2 - not used L - not used O - Cool active reversing valve B - Heat active reversing valve G - Fan relay D - Dehumidification relay H - Humidification relay
TERMINAL DESIGNATIONS
W2
D
Y2
C
C
H
R
Y1
W1
L
G
L
B
O
* Please refer to furnace
installation manual for proper terminations
Note: To avoid electrical problems, use the system transformer for both
the thermostat and humidifier.
9851
i
Humidifier
D
Remove 1/4” of insulation from end of each wire
Open the case with a screwdriver. Place in slot and gently pry forward at all four locations.
2
1
2
3
4
DELUXE PROGRAMMABLE THERMOSTATS
NOTE: For 9851i single stage heat pump applications, place a jumper between the W1 and Y1 terminals.
7
Connect wiring between unit and furnace. For Model 9865i (2H/2C furnace applications):
8
Replace cover on thermostat. Turn on power to unit and proceed with programming per instructions on the display or in the user’s manual.
11
Connect wiring between unit and heat pump. Jumper W2 to E/W1 for control of auxiliary heat in both 2
nd
stage and emergency modes. For Model 9870i (2H/2C heat pump applications):
9
To set your name and phone number into the thermostat press MENU, select INSTALLER SETTINGS, and CONTACT INFORMATION. The screen at the bottom left should appear.
To enter your name press EDIT. Use the UP or DOWN button to scroll through the characters. (DOWN gets you to the letters faster.) After each letter press NEXT.
When you are done entering your name, press ACCEPT.
Connect wiring between the thermo­stat and the indoor sensor (9020i) and the outdoor sensor (9025i), if used. Use twisted pair wiring (22AWG minimum) with a maximum length of 300 feet (or 100m).
10
Now enter your phone number. Use the UP and DOWN arrow to select the first number. Press NEXT. When you have completed entering your phone number, press ACCEPT.
The screen will return to the INSTALLER SETTINGS. Finish setting the thermostat for the application.
Y1
R
C
E/W1
H O B G
Furnace
Thermostat
C - Common 24 VAC R - System transformer Y1 - 1st stage cooling W1- 1st stage heating W2- 2nd stage heating Y2 - 2nd stage cooling L - not used O - Cool active reversing valve B - Heat active reversing valve G - Fan relay D - Dehumidification relay H - Humidification relay
TERMINAL DESIGNATIONS
W2
D
Y2
C
C
H
R
Y1
W1
W2
Y2
L
G
L
B
O
* Please refer to furnace
installation manual for proper terminations
Note: To avoid electrical problems, use the system transformer for both
the thermostat and humidifier.
Humidifier
Wiring Terminals*
D
98
6
5
i
Y1
R
C
E/W1
H O B G
Heat Pump
Wiring
Terminals*
Thermostat
C - Common 24 VAC R - System transformer Y1 - Compressor output E/W1 - Emergency heat relay W2 - 2nd stage heating Y2 - 2nd stage cooling L - System check O - Cool active reversing valve B - Heat active reversing valve G - Fan relay D - Dehumidification relay
(to DS terminal)
H - Humidification relay
(to Humidifier)
TERMINAL DESIGNATIONS
W2
D
Y2
C
C
H
R
Y1
E/W1
W2
Y2
G
L
B
L
O
D
* Please refer to heat pump and
furnace installation manuals for proper terminations
Note: To avoid electrical problems, use the system transformer for both
the thermostat and humidifier.
Humidifier
9870
i
Set Your Name Set Your Phone Number
Y1
R
C
E/W1
H O B G
Heat
Pump
Terminals*
Wiring
Thermostat
C - Common 24 VAC R - System transformer Y1 - 1st stage cooling W1- 1st stage heating W2- not used Y2 - not used L - not used O - Cool active reversing valve B - Heat active reversing valve G - Fan relay D - Dehumidification relay H - Humidification relay
TERMINAL DESIGNATIONS
W2
D
Y2
C
C
H
R
Y1
W1
L
G
L
B
O
* Please refer to heat pump and
furnace installation manuals for proper terminations
Note: To avoid electrical problems, use the system transformer for both
the thermostat and humidifier.
Humidifier
D
Jumper
9851
i
CONTACT INFORMATION
BACK
EDIT
ACCEPT
NEXT
CONTACT INFORMATION
AIR EXPERTS
CONTACT INFORMATION
AIR EXPERTS
ACCEPT
NEXT
1
ACCEPT
NEXT
CONTACT INFORMATION
AIR EXPERTS
1-555-555-1212
1
2
13
Recycling Thermostat
If this thermostat REPLACES a thermostat that contains mercury, DO NOT discard the old thermostat in the regular trash. Mercury is harmful to humans and the environment. For this reason, do not open, break, or crush the mercury cell. If mercury leaks from a damaged cell, DO NOT touch or handle mercury with bare hands. Use protective, non-absorbent gloves to place mercury into a sealable container. Fill the container with sand or another absorbent material and seal the container completely.
Return the mercury or mercury products, in a sealed container, to Invensys Climate Controls or a local recycling center for proper disposal. If you have any questions, call Robertshaw technical support at 1-800-445-8299.
Invensys Climate Controls 28C Leigh Fisher Blvd. El Paso, TX 79906 Attn: Mercury Recycling Center
Climate Controls Americas 515 South Promenade Avenue Corona, CA 92879-1736 United States of America Made in Mexico www.about-i-series .com