Roberts Gorden HE-100, HE-175, HE-125, HE-150, HE-80 User Manual

...
Vantage HE
Vantage HE
®
Quality in Any Language
TM
The Infrared Heater Designed for Harsh Environments
Effective in high moisture
environments due to durable
components
protective enclosure for
controls minimizes exposure
to dirt and moisture from
combustion air
Approved for indoor and
outdoor installations
Design flexibility achieved
with broad range of burner
inputs and tube lengths
Diagnostic capability
incorporated in burner
design
A
C
D
B
A
C
D
B
VANTAGE®HE
Model HE-40 HE-60 HE-80 HE-100 HE-125 HE-150 HE-175
Length of Straight Tube (ft, in) A 10 20 20 30 40 50 60 Length of U-Tube (ft, in) B N/A 11,7 11,7 16,7 21,7 26,7 31,7 Overall Length of Straight Tube (ft, in) C 11,5.5 21,5.5 21,5.5 31,5.5 41,5.5 51,5.5 61,5.5 Overall Length of U-Tube (ft, in) D N/A 13,0.5 13,0.5 18,0.5 23,0.5 28,0.5 33,0.5
Input (Btu/h) x (1000) 40 60 80 100 125 150 175
Fuel Natural Gas (NG) or Propane Gas (LP) Inlet Pressure (in wc) NG min. 4.6 4.6 4.6 4.6 4.6 4.6 5
LP min. 11 11 11 11 11 11 11
14 maximum for NG & LP Gas Connection NPT 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” Electrical Supply 120 V, 60 Hz, 1 A (Run) 5 A (Start) Heat Exchanger Tubing 10 ft Sections, 4" dia, 16 Gauge, First 10 ft ALUMI-THERM
®
Steel Tubing
(Remaining Heat Treated Aluminized Steel Tubing) Exhaust Flue 4” dia Reflector and End Caps .024 Stainless Steel Type 304 (Optional - .024 Aluminum) Control System Honeywell
®
SmartValve® II Combines Gas Valve and Hot Surface Electronic Ignition Control
Fully Automatic, Four-Try, 100% Shut-Off, Prepurge, Auto Reset, LED Indicator Status Approved As Indoor and Outdoor (Vented or Unvented) Certification ANSI Z83.20/CSA 2.34, 2.17, 2.20 Warranty Three-Year Limited (Refer to Installation, Operation and Service Manual for Details)
Weights
Burner (lb) 40 Vent Cap Package Included (lb) 4
Overall Length of Tube and Accessory Packages (ft) 10 20 30 40 50 60
Aluminized Tube with Aluminum Reflector (lb) 52 86 120 161 206 240 Aluminized Tube with Stainless Steel Reflector (lb) 66 113 152 208 265 304
U-Tube Packages (lb)
Aluminized Tube with Aluminum End Caps 19 Aluminized Tube with Stainless Steel End Caps 20
Clearances to Combustibles* (in)
Model HE-40 HE-60 HE-80 HE-100 HE-125 HE-150 HE-175
Horizontal 45° Horiz. 45° Horiz.45° Horiz.45° Horiz.45° Horiz. 45° Horiz. 45° Horiz. 45°
A 6 8 6 8 6 8 6 10 6 10 6 12 8 12 B 278 358 388 408 468 508 52 8 C 5351 6360 6666 7174 7778 8084 82 85 D 2746 3554 3860 4064 4669 5074 52 79
Roberts-Gordon
1250 William Street P.O. Box 44 Buffalo, NY 14240-0044 USA Telephone: 716.852.4400 Fax: 716.852.0854 Toll Free: 800.828.7450
www.rg-inc.com
Roberts-Gordon
76 Main Street West Unit 10 Grimsby, Ontario L3M 1R6 Canada Telephone: 905.945.5403 Fax: 905.945.0511
European Office:
Roberts-Gordon Telephone: +44(0) 1902 494425 Fax: +44(0) 1902 403200
Printed in U.S.A HESNA 5M 0205 Rev. E
©2005 Roberts-Gordon All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means – graphic, electronic
or mechanical, including photocopying, recording, taping, or information storage and retrieval systems – without written permission of Roberts-Gordon.
Turbulator (some models)
Reflector
Overall Length C
17.5"
(44 cm)
Length A
13.5"
(34 cm)
9.5"
(24 cm)
Burner End View Side View Top View
Length B
Overall Length D
18"
(457 mm)
*Clearances B, C, D can be reduced by 50% for locations 25 ft (7m) or more downstream of the burner. For other mounting options and associated clearances,
complete installation, operation and service criteria, please see the current issue of the VANTAGE
®
HE Installation, Operation and Service Manual.
Installation Code: ROBERTS GORDON
®
products are to be installed only in accordance with local laws, codes and regulations, and only by a contractor qualified in the
installation and service of gas-fired heating equipment. This product is not for residential use.
Further Information: Applications, engineering and detailed guidance on systems design, installation and product performance is available through ROBERTS GORDON®North
American independent distributors. Please contact us for any further information you may require, including the VANTAGE
®
HE Installation, Operation and Service Manual.