RME ADI-6432R BNC User manual

User's Guide
ADI-6432R BNC
Multichannel Audio Digital Interface
SyncAlignTM
Intelligent Clock Control
SteadyClockTM
Hi-Precision 24 Bit / 192 kHz
64-Channel Bidirectional Format Converter
MADI - AES-3id Interface
MIDI embedded in MADI
RS232 embedded in MADI
MIDI Remote Control
TM
TM
Important Safety Instructions..................................4
General
1 Introduction ...............................................................6
2 Package Contents.....................................................6
3 Brief Description and Characteristics.....................6
4 First Usage - Quick Start
4.1 Controls and Connectors.......................................7
4.2 Quick Start .............................................................9
5 Accessories.............................................................10
6 Warranty...................................................................10
7 Appendix..................................................................10
Usage and Operation
8 Front Panel Controls
8.1 MADI INPUT ........................................................14
8.2 MADI OUTPUT ....................................................14
8.3 AES......................................................................14
8.4 CLOCK.................................................................15
8.5 REMOTE..............................................................15
9 Inputs
9.1 MADI ....................................................................16
9.2 AES-3id................................................................16
10 Outputs
10.1 MADI ....................................................................17
10.2 AES-3id................................................................17
11 Word Clock
11.1 Word Clock Input and Output...............................18
11.2 Technical Description and Background...............19
11.3 Cables and Termination.......................................20
12 MIDI and RS232
12.1 Transmission of MIDI...........................................21
12.2 Remote Controlling the ADI-6432........................21
12.3 Remote Control Software.....................................22
12.4 RS232 ..................................................................23
13 Application Examples
13.1 Digital AES-3id Multicore .....................................24
13.2 Digital AES-3id Breakout box...............................24
13.3 MADI to MADI Converter .....................................26
13.4 AES Inserter.........................................................26
13.5 MADI Merger........................................................26
2
User's Guide ADI-6432R BNC © RME
Technical Reference
14 Technical Specifications
14.1 Inputs...................................................................30
14.2 Outputs ................................................................30
14.3 MIDI – RS232 ......................................................31
14.4 Digital...................................................................31
14.5 General................................................................31
14.6 Firmware..............................................................32
14.7 Connector Pinout RS232.....................................32
14.8 MADI User Bit Chart ............................................32
15 Technical Background
15.1 Terminology.........................................................33
15.2 Lock, SyncCheck and SyncAlign.........................34
15.3 MADI Basics ........................................................35
15.4 SteadyClock.........................................................36
16 Block Diagram.........................................................37
17 MIDI Implementation Chart
17.1 Basic SysEx Format ............................................38
17.2 Message Types ...................................................38
17.3 MADI Input State – Redundancy Mode...............38
17.4 Table....................................................................39
User's Guide ADI-6432R BNC © RME
3
Important Safety Instructions
ATTENTION! Do not open chassis – risk of electric shock
The unit has non-isolated live parts inside. No user serviceable parts inside. Refer service to qualified service personnel.
Mains
• The device must be earthed – never use it without proper grounding
• Do not use defective power cords
• Operation of the device is limited to the manual
• Use same type of fuse only
To reduce the risk of fire or electric shock do not expose this device to rain or moisture. Prevent moisture and water from entering the device. Never leave a pot with liquid on top of the device. Do not use this product near water, i. e. swimming pool, bathtub or wet basement. Danger of condensation inside – don't turn on before the device has reached room temperature.
Installation
Surface may become hot during operation – ensure sufficient ventilation. Avoid direct sun light and do not place it near other sources of heat, like ra­diators or stoves. When mounting in a rack, leave some space between this device and others for ventilation.
Unauthorized servicing/repair voids warranty. Only use accessories specified by the manufacturer.
Read the manual completely. It includes all information necessary to use and operate this device.
4
User's Guide ADI-6432R BNC © RME
User's Guide
ADI-6432R BNC
General
User's Guide ADI-6432R BNC © RME
5
1. Introduction
With the ADI-6432R BNC you have an incredibly versatile digital interface to your supply. From small project studios to broadcast and television, this Advanced Digital Interface is the perfect solution for many tasks.
As a consequent continuation of RME's world-wide successful ADI series, the 6432 also con­tains elaborate technology and the latest integrated circuits. In a few words: The ADI-6432R BNC is a uniquely powerful and high-quality device, which will excite you even after many years of operation.
2. Package Contents
Please check that the package contains each of the following:
ADI-6432R BNC
Manual
Power cord
3. Brief Description and Characteristics
The ADI-6432 consists of two digital format converters in reference quality, in a standard 19" box with 2 unit height. The compact device has numerous extraordinary features like Intelligent Clock Control (ICC), SyncCheck, SyncAlign, SteadyClock, MIDI over MADI, RS232 over MADI, and remote control via MADI and MIDI.
All of the ADI-6432 I/Os support 192 kHz/24 bit. The format conversion between MADI and AES/EBU operates in both directions at the same time. LEDs of different colours show the pre­sent state of incoming and outgoing signals and of the internal processing in a clear way.
The unique Intelligent Clock Control (ICC) allows for a flexible use with internal clock (44.1 up to 192 kHz), external word clock or the digital input signals. These options are intelligently coupled in a way typical for RME, and easy to apply thanks to a clear and easily understandable display of the Lock and Sync states.
The ADI-6432 transmits both MIDI and RS232 invisibly within the MADI data stream, maintain­ing full compatibility. The unit can also be remote controlled via MIDI.
The ADI-6432R BNC has two separated, simultaneously operating power supplies. It can be connected to two different power sources at the same time, enabling a redundancy mode of the power supply. If one of the internal or external power sources fails the unit continues to work without any interruption.
To activate this mode both IEC receptacles have to be connected to different power sources, and both power supplies have to be switched on at the front of the unit, so that both POWER LEDs light up.
The power consumption of the unit in redundancy mode is increased by only a few Watts, caused by the limited efficiency (internal loss) of each single power supply.
6
User's Guide ADI-6432R BNC © RME
4. First Usage – Quick Start
4.1 Controls and Connectors
The front of the ADI-6432 features nine buttons with 31 LEDs, and an extensive Status Display including 97 more LEDs.
MADI INPUT determines the current input for the MADI signal (optical/coaxial). The state of the input signal is shown in the STATE section (ERROR, 64-channel mode and 96k frame format) and also in the big LED display in detail.
AES INPUT displays the basic state of the AES input signal: ERROR, Double Speed and Quad Speed. The big LED display, AES INPUT STATE, shows the presence of a valid input signal separately for each AES input. RME's exclusive SyncCheck indicates via flashing LEDs if one of these inputs is locked, but not synchronous to the chosen clock reference.
WORD INPUT displays the basic state of the word clock input signal: ERROR, Double Speed and Quad Speed. Note that these LEDs are only active when word has been chosen as clock reference.
In the CLOCK SECTION the current clock reference and frequency multiplier is chosen. MADI OUTPUT is used to configure the MADI output as 56/64 channel or 48k/96k frame for-
mat.
REMOTE defines the source for MIDI remote control operation (MADI or DIN jack). MIDI INPUT indicates received MIDI data from the 5-pin DIN input or the MADI input. COM indicates serial data being received or transmitted via the COM connector. LOCK KEYS allows to switch off all buttons. This way the ADI-6432 can be secured against
accidental operating errors.
User's Guide ADI-6432R BNC © RME
7
The rear of the ADI-6432R BNC provides the following connections: 64 BNC connectors (AES­3id I/O), two MADI optical, two MADI coaxial (BNC), two word clock (BNC), two MIDI (5-pin DIN), one RS232 (D-Sub), and two mains power.
MADI I/O optical: Standard MADI ports. MADI I/O koaxial (BNC): Standard MADI ports. AES-3id (64 x BNC): Each of the 64 BNC sockets transfers 2 channels of digital audio each. WORD IN (BNC): A push switch allows to activate internal termination (75 Ohms). WORD OUT (BNC): Standard word clock output. MIDI I/O (5 pin DIN): MIDI input and output via 5-pin DIN jacks. Used for transmission of MIDI
data via MADI, and for remote control of the ADI-6432.
COM (9 pin D-sub): Serial interface for data transmission via MADI.
IEC receptacle for power connection. The specially developed, internal hi-performance switch
mode power supply makes the ADI-6432 operate in the range of 100V to 240V AC. It is short­circuit-proof, has an integrated line-filter, is fully regulated against voltage fluctuations, and sup­presses mains interference.
The ADI-6432R BNC uses two identical, complete power supplies, which operate simultane­ously and in parallel. This allows for a redundant operation on the power side by connecting the second mains receptacle to a different power source. The unit will continue to operate without interruption if one of the power sources fails.
8
User's Guide ADI-6432R BNC © RME
4.2 Quick Start
Configuration starts with choosing the MADI input, BNC or optical. The state of the input signal is
displayed by a total of 38 LEDs. Shown are active input, automatic input selection, receiver state, Sync, 56 or 64 channel format, 48k frame or 96k frame, and audio data on a stereo basis. The Sync LED shows the synchronicity between input signal and external/internal clock, or between the active inputs.
In the AES INPUT STATE section, each of the 32 inputs has its own SYNC LED. One LED per (stereo) input indicates audio information within the data stream. An input signal in the range of 60 kHz to 100 kHz will turn the DS LED on. An input signal in the range of 162 kHz to 200 kHz will turn the QS LED on.
The source and frequency of the unit's clock is configured in the CLOCK SECTION. The but­tons CLOCK let you step through the options external clock (AES, MADI, word) and internal clock (44.1 or 48 kHz). The button STATE sets the range for the internal, but also the external sample rate. Selecting DS will result in 88.2 and 96 kHz, selecting QS sets 176.4 and 192 kHz.
The MADI output signal can include 56 or 64 channels (FORMAT). The FRAME button switches the MADI output into native Double Speed mode (96K), in case internal or external clock allow this mode to be activated.
The ADI-6432 can be remote controlled by MIDI commands. The button REMOTE is used to select the source of the MIDI remote control commands, and also the destination for the ADI­6432's request replies. The standard MIDI ports or the MADI input and output can be chosen.
LOCK KEYS allows to switch off all buttons. This way the ADI-6432 can be secured against accidental operating errors.
The ADI-6432 remembers all settings before switching off, and sets them automatically when switching on the next time.
User's Guide ADI-6432R BNC © RME
9
5. Accessories
RME offers several optional components for the ADI-6432, for example MADI Optical Cable: ONK0100 MADI Optical Network Cable, 1 m (3.3 ft)
ONKD0300 MADI Optical Network Cable, 3 m (9.9 ft) ONKD0600 MADI Optical Network Cable, 6 m (19.8 ft) ONKD1000 MADI Optical Network Cable, 10 m (32.8 ft) ONKD2000 MADI Optical Network Cable, 20 m (65.6 ft) ONKD5000 MADI Optical Network Cable, 50 m (164 ft)
6. Warranty
Each individual ADI-6432R BNC undergoes comprehensive quality control and a complete test at IMM before shipping. The usage of high grade components should guarantee a long and trouble-free operation of the unit.
If you suspect that your product is faulty, please contact your local retailer. Audio AG grants a limited manufacturer warranty of 6 months from the day of invoice showing
the date of sale. The length of the warranty period is different per country. Please contact your local distributor for extended warranty information and service. Note that each country may have regional specific warranty implications.
In any case warranty does not cover damage caused by improper installation or maltreatment ­replacement or repair in such cases can only be carried out at the owner's expense.
No warranty service is provided when the product is not returned to the local distributor in the region where the product had been originally shipped.
Audio AG does not accept claims for damages of any kind, especially consequential damage. Liability is limited to the value of the ADI-6432R BNC. The general terms of business drawn up by Audio AG apply at all times.
7. Appendix
RME news and further information can be found on our website: http://www.rme-audio.com Distributor: Audio AG, Am Pfanderling 60, D-85778 Haimhausen, Tel.: (49) 08133 / 91810 Manufacturer:
IMM Elektronik GmbH, Leipziger Strasse 32, D-09648 Mittweida
Trademarks
All trademarks and registered trademarks belong to their respective owners. RME, Hammerfall and DIGICheck are registered trademarks of RME Intelligent Audio Solutions. ADI-6432, SteadyClock, SyncAlign, SyncCheck and Intelligent Clock Control (ICC) are trademarks of RME Intelligent Audio Solutions. S/MUX is copyright Sonorus.
Copyright © Matthias Carstens, 04/2011. Version 1.1
10
User's Guide ADI-6432R BNC © RME
All entries in this User’s Guide have been thoroughly checked, however no guarantee for cor­rectness can be given. RME cannot be held responsible for any misleading or incorrect informa­tion provided throughout this manual. Lending or copying any part or the complete manual or its contents as well as the software belonging to it is only possible with the written permission from RME. RME reserves the right to change specifications at any time without notice.
CE / FCC Compliance
CE
This device has been tested and found to comply with the limits of the European Council Direc­tive on the approximation of the laws of the member states relating to electromagnetic compati­bility according to RL2004/108/EG, and European Low Voltage Directive RL2006/95/EG.
FCC
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protec­tion against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
RoHS
This product has been soldered lead-free and fulfils the requirements of the RoHS directive.
ISO 9001
This product has been manufactured under ISO 9001 quality management. The manufacturer, IMM Elektronik GmbH, is also certified for ISO 14001 (Environment) and ISO 13485 (medical devices).
User's Guide ADI-6432R BNC © RME
11
Note on Disposal
According to the guide line RL2002/96/EG (WEEE – Directive on Waste Electrical and Electronic Equipment), valid for all european countries, this product has to be recycled at the end of its lifetime.
In case a disposal of electronic waste is not possible, the recycling can also be done by IMM Elektronik GmbH, the manufacturer of the ADI-
6432. For this the device has to be sent free to the door to: IMM Elektronik GmbH
Leipziger Straße 32 D-09648 Mittweida Germany
Shipments not prepaid will be rejected and returned on the original sender's costs.