Rinnai Water Heater FC824P Specifications

FC824 (RCE-691TA-H)
Type of Appliance
Rinnai Model Number
Gas Rate Input (BTU/hour)
Minimum Gas Supply Pressure
Maximum Gas Supply Pressure
Electrical Connection
Combustion System
Ignition System
Fan CFM Output
Temperature Settings
Temperature Control
Weight
Clearance from Combustibles
Vent free gas fan convection heater, suitable for homes, apartments, and condominiums, residential or commercial setting; modular/mobile home approved; forced combustion, forced convection
RCE-691TA-H-N (Natural gas) RCE-691TA-H-P (Propane)
Low - 8,400 Low - 8,000 High - 24,000 High - 22,000
5.0 in (135 mm) W.C. 8.0 in (203 mm) W.C.
10.0 in (266 mm) W.C 13.0 in (330 mm) W.C.
AC 120V, 60 Hz, 29 watts
1/2 inch Male NPT
Ceramic Burner
Electronic spark ignition
Low: 109.5 High: 215.4
Low (LO): minimum combustion 60° - 80° F in 2° increments High (HI): maximum combustion
Electronic thermostat
Approximately 26.5 lbs (12 kg)
Side: 2 in. (50 mm), Top: 2 in. (50 mm), Front: 30 in. (762 mm) Back: 2 in. (50 mm), Bottom: 0 in.
Noise Level
Warm Air Outlet
Maximum Installation Elevation
FEATURES
99.9% Efficient
Cool-to-the-touch cabinet
Modulating Technology
Programmable Thermostat
Child-Safety Lock
Digital, Adaptive Control
Electronic Ignition - No Pilot Light
On Board Self-Diagnostics for Easier Maintenance
Tilt Switch
Push-Button, Electronic Ignition
© 2015 Rinnai Corporation
Low-30dB High-44dB
Bottom front louvers
5,200 Feet
FC824 (RCE-691TA-H SP) 7/2015
FC824 (RCE-691TA-H)
Safety Devices
Overheat Switch: The appliance will automatically shut down when the
appliance exceeds a predetermined temperature.
Warranty
Conversion Kit
Flame Failure Device: The appliance will automatically shut down if the
burner flame is extinguished.
Oxygen Depletion Sensor: If the oxygen level in the room drops below a
preset limit, this sensor disables the gas supply to the heater.
Tilt Switch: If the heater is knocked over, the tilt switch will disable the gas
supply. The fan will continue to purge. Convection fan continues to run after burner shutdown to cool internal parts.
Child Lock: Prevents inadvertent operation.
Power Failure: The appliance will disable the gas supply if it loses
electrical power.
Fuse: The electrical circuits are protected by a fuse. When the 5 amp fuse
blows, the heater will not operate until the 5 amp fuse is replaced.
3 years from date of purchase on all parts
NA-Unit is not field convertible
This appliance is intended for supplemental heating only. The International Fuel Gas Code Standard 620-6 “Prohibited Use” states that “One or more unvented room heaters shall not be used as a sole source of comfort heating in any dwelling”.
ATTENTION
DIMENSIONS
24 in (610 mm)
19 in
(482 mm)
9.4 in
(239 mm)
Rinnai America Corporaon • 103 Internaonal Drive, Peachtree City, GA 30269
©2015 Rinnai America Corporaon. Rinnai is connually updang and improving products; therefore, specicaons are subject
to change without prior noce. Local, state, provincial, federal and naonal fuel gas codes must be adhered to prior to and upon installaon.
Toll-Free: 1-800-621-9419 • Phone: 678-829-1700 • www.rinnai.us
Loading...