Direct vent wall furnace suitable for homes, apartments, and
condominiums, residential or commercial setting; modular/mobile home
approved; forced combustion, forced convection
Restarts automatically when ignition or combustion fails.
Starts and turns off the heater at 2 timer settings.
Provides precise gas flow by operating from one to seven stages.
Detects temperature change in 1/2 of a degree.
Monitors and controls combustion fan and allows the appliance to overcome
winds of up to 40 mph.
Continually monitors functions; provides auto shutdown codes; indicates
Reduces noise through use of swept blades in convection fan; quiet
expansion / contraction of parts due to temperature changes.
Ability to connect to a field supplied wall thermostat.
RHFE-265FTA2 SP 8/2017
EX11CT (RHFE-265FTA2)
Safety Devices
Venting
Maximum Vent Length
Wall Thickness and
Flue Manifold Kits
(the “A” vent kit is included
with the appliance)
Warranty
Flame rod detects flame failure; results in auto shutdown to prevent escape
of gas
Bi-metal switch, thermal fuse, and thermistor detect overheat condition;
results in auto shutdown
3 amp fuse protects against power surge; results in auto shutdown
Abnormal spark at time of ignition results in auto shutdown
Combustion fan purges any gas from the combustion chamber before
ignition
Convection fan continues to run after burner shutdown to cool internal parts
Child lock prevents inadvertent operation
Appliance shuts down if room reaches 104° F (40° C)
Concentric; 3 1/8 inch (80 mm) wall hole
13 feet (4 m) with a maximum of 2 bends;
maximum 8 ft (2.4 m) vertically for altitudes at or below 2000 ft (610 m)
maximum 5 ft (1.5 m) vertically for altitudes above 200 ft (610 m)
Name Kit No. Fits Walls
S Vent Kit FOT-150 3 - 4 1/2 in (75 - 115 mm)
A Vent Kit FOT-151 4 1/2 - 9 1/2 in (115 - 240 mm)
B Vent Kit FOT-152 9 1/2 - 15 3/4 in (240 - 400mm)
C Vent Kit FOT-153 15 3/4 - 23 5/8 in (400 - 600 mm)
D Vent Kit FOT-154 23 5/8 - 31 1/2 in (600 - 800 mm)
Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years
Conversion Kit
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.
DIMENSIONS
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
To natural gas: 204000034 To propane gas: 204000038
EX11CT (RHFE-265FTA2)
Clearance for Maintenance
Clearance to Combustibles
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
Zone Cubic Feet Square Feet*
5,471 -7,430 681 -930
1
2
3,551 - 4,820 441 - 600
3 2,981 - 4,050 371 - 510
2,521 - 3,430 321 - 430
4
5 2,081 - 2,830 261 - 350
6 1,701 - 2,310 211 - 290
7
1,551 - 2,110 191 - 260
EX11CT (RHFE-265FTA2)
Selection is based on installation locations at 2000ft or below. If the
installation is above 2000ft please contact Rinnai.
In bathrooms, select a product equal to or less than 6000BTUH.
In bedrooms, select a product equal to or less than 10000BTUH.
In single rooms in Region V, multiply the room’s volume by 3.20. The
result is the maximum heat input (BTUH) of the product you should
consider.
Chart should not be used as the sole document for making final product
selection. Consult with your Rinnai independent dealer.
Square footage column based off of an 8ft ceiling assumption.
The guidelines apply to average house construction.
This is intended to be used as a guide and not a replacement for a
professionally engineered project.
Rinnai has not been to the location so this guidance is for your
assistance only and should not be the sole factor in making a sizing
selection.
Sizing does not describe a complete system.
The contractor/engineer must determine the necessary components for
and configuration of the particular system being installed.
Sizing does not imply compliance with local building codes.
It is the responsibility of the engineer/contractor to ensure the
installation is in accordance with all local building codes.
Confer with local building officials before installation.
RAC, its agents, employees, directors, officers, parent or affiliate
companies assume no liability for damages arising from information
provided herein to or by consumers or third parties or for damages
arising from or associated with water quality, compliance with local
codes, installation methods, materials or other circumstances related to
application or installation.
For primary heat applications, perform a Manual J sizing calculation.
Chart is to be used for supplemental heat applications only.