Rinnai RPC26WA User Manual

Operation Manual
Portable Room Air Conditioner
Models: RPC26WA / RPC35WA / RPC41WA
COLL
MID
HEAT
LOW
DRY
FAN
C
F
TIMER
SLEEP
SWING
This appliance shall be installed in accordance with:
• Manufacturer’s Installation Instructions
• Current AS/NZS 3000
• Local Regulations and Municipal Building Codes including local OH&S requirements This appliance must be installed, maintained and removed only by an Authorised Person. For continued safety of this appliance it must be installed and maintained in
accordance with the manufacturers instructions.
BEFORE PROCEEDING WITH THE OPERATION OF YOUR NEW RINNAI PORTABLE ROOM AIR
CONDITIONER PLEASE READ THIS MANUAL THOROUGHLY AND GAIN A FULL UNDERSTANDING OF THE
REQUIREMENTS, FEATURES AND OPERATION OF YOUR NEW APPLIANCE.
Rinnai 2 Portable Room AC OIM
TABLE OF CONTENTS
Safety & Important Points 4
Warranty & Specications 5
Unpacking the Appliance .................................................................................................................................... 5
Warranty ............................................................................................................................................................. 5
Specications  ..................................................................................................................................................... 5
Air Conditioner Basics 6
Appliance Components  ...................................................................................................................................... 6
Control Panel ...................................................................................................................................................... 7
Basic Operation  .................................................................................................................................................. 7
Basic Operation Control Panel  ........................................................................................................................... 7
COOL .............................................................................................................................................................7
DRY (Dehumidifying) ......................................................................................................................................7
Operation 8
FAN ................................................................................................................................................................8
SLEEP Function ............................................................................................................................................. 8
Care & Maintenance 9
General Maintenance ......................................................................................................................................... 9
Cleaning the Air Filter ......................................................................................................................................... 9
Save a Service Call .......................................................................................................................................... 10
When to Call for Service ................................................................................................................................... 10
Installation 11
Location ............................................................................................................................................................ 11
Duct Assembly  .................................................................................................................................................. 11
Exhaust Ducting Options  .................................................................................................................................. 12
Window Installations ..................................................................................................................................... 12
Semi-Permanent Wall Installation  ................................................................................................................13
Condensate Drainage  ...................................................................................................................................... 13
Internal Condensate Tank  ............................................................................................................................13
Fixed Condensate Drainage Hose  ............................................................................................................... 13
Contacts 16
Rinnai 3 Portable Room AC OIM
WARNING
IMPORTANT
SAFETY & IMPORTANT POINTS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always  comply  with the  following  precautions  to  avoid  dangerous  situations  and  to  ensure  optimum 
performance.
Failure to carefully read and  follow all instructions  in this manual can result  in equipment malfunction,  property damage, personal injury and/or death.
WARNINGS: WHEN IGNORED, CAN RESULT IN SERIOUS INJURY OR DEATH.
CAUTIONS: WHEN IGNORED, CAN RESULT IN MINOR INJURY OR PRODUCT DAMAGE.
The  appliance  is  tted  with  an  Australian  exible  cord  and  2  pin  plug  intended  for connection  to  an  Australian 10 Amp socket outlet. It is not suitable for connection in other countries or alternative power  supplies. Ensure that the voltage and frequency of  the power supply  correspond to the  ratings on the 
dataplate of the appliance.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or  mental capabilities,  or lack of experience and knowledge, unless  they have been given supervision or  instruction concerning use of the appliance by a person responsible for their safety.
Young children should be supervised to ensure they do not play with the appliance.
DO NOT allow children or persons with reduced physical, sensory or mental capabilities to sleep directly  in front of this appliance.
DO NOT allow children to ‘post articles’ into the louvres of the appliance.
DO NOT use power boards or double adaptors with this appliance.
DO NOT coil or bundle the electric cord to reduce it’s length as overheating of the cord may occur which 
could result in a re hazard.
The exible cord and plug must not be modied. If the cord or plug are damaged, they must be replaced  by Rinnai or a Rinnai appointed service agent.
DO NOT cover or place articles on or against any parts of this appliance, to avoid overheating.
DO NOT sit on this appliance
DO NOT use this appliance in the immediate surroundings of a bath, a shower or a swimming pool.
DO NOT move this appliance whilst it is turned on.
DO NOT unplug the appliance by pulling on the exible cord.
DO NOT handle any parts of this appliance, including the plug and exible cord, with wet or damp hands.
DO NOT immerse the appliance, exible cord and plug in water or any other liquid.
DO NOT place containers of any liquid or wax on top of this appliance.
Turn o󰀨 the appliance and unplug from the power socket outlet when not in use.
DO NOT use in areas where ammable liquids are stored.
This appliance is suitable for indoor use only.
Never  dismantle  the  appliance.  Tampering  with  electrical  connections  and  components  is  highly  dangerous and may cause appliance malfunction, property damage, personal injury and/or death.
Rinnai 4 Portable Room AC OIM
WARRANTY & SPECIFICATIONS
UNPACKING THE APPLIANCE
If any damage is evident DO NOT INSTALL or OPERATE and contact your supplier for advice.
WARRANTY
The benets to the consumer given by this warranty are in addition to all other rights and remedies of the consumer  under a law in relation to the goods or services to which the warranty relates.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled  to a replacement or refund for  a major  failure and for compensation for any other loss or damage. You are  also  entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not  amount to a major failure.
This appliance has a 2 year parts warranty from date of purchase. If the product fails within this 2 year period return  it to the supplier with proof of purchase for repair or replacement.
Supplier warranty claims  for Rinnai products or services must be  made by contacting Rinnai Australia.  Contact  details are on the back of this document.
The following exclusions may cause the warranty to become void and may result in a service charge and costs of  parts (if required):
1. Accidental damage and acts of God.
2. Failure due to abuse or misuse, improper maintenance, failure to maintain or improper storage.
3. Failure due to incorrect or unauthorised installations or outdoors use.
4. Failure or damage caused by  alterations,  service  or  repair  work carried out by persons other  than  Rinnai 
service persons or service agents.
5. Where it is found that there is no fault with the appliance and the issue is related to the installation or is due  to the failure of electricity supply.
SPECIFICATIONS
MODEL RPC26WA RPC35WA RPC41WA
Power Supply V/Hz 220-240~ / 50
Maximum Input Power W 1200 1600 2000
Dimensions - Net (H x W x D)
Dimensions - Packing (H x W x D) 890 x 520 x 450
Weight kg 32
Nominal Cooling Capacity kW 2.60 3.55 4.10
Rated Input Current A 4.45 5.95 7.89
Rated Input Power kW 1.00 1.34 1.78
Refrigerant Type R410A
Refrigerant Volume g 350 520 520
mm
798 x 475 x 417
Rinnai 5 Portable Room AC OIM
Loading...
+ 11 hidden pages