Rinnai RL75IN, RL75IP Specifications

RL75i (VC2528FFUD-US)
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
0 25 50 75 100 125 150
Type of Appliance
Rinnai Model Number
Operation / Installation
Minimum/Maximum Gas Rate (Input)
Electrical
Electrical Consumption
Amperage
Hot Water Capacity
Temperature
Temperature (without remote)
Installation
Energy Factor
Service Connections
Isolation & Pressure Relief Valves Included
Water Flow Control
Minimum/Maximum Water Supply Pressure
Temperature controlled, continuous flow, gas hot water system Certified for installation in manufactured (mobile) homes Forced combustion / Direct vent
REU-VC2528FFUD-US
Forced combustion; indoor only
10,300 - 180,000 BTU/h
Appliance: AC 120 Volts - 60 Hz Controller: DC 12 Volts
Normal: 76 w Standby: 2 w Anti-frost protection: 120 w
Max with pump: 8A Max without pump: 4A Fuse: 10A
Direct electronic ignition
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 6.5 GPM (24.6 l/min)
98° - 120° F (37° - 49° C) (factory default) Maximum temperature is selectable at 120° F(49° C) or at 140° F(60° C); 98° - 160° F(37° ­71° C) available with MCC-91-2 controller for hydronic applications
120° F (49° C) (factory default) or 140° F (60° C)
Indoor only
Natural Gas: 0.82 Propane: 0.82
Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT
Isolation Valves are certified to NSF/ANSI 61 for potable water
Water flow sensor, electronic water control device and fixed by-pass
20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
8.0 (30.3)
7.0 (26.5)
6.0 (22.7)
5.0 (19.0)
4.0 (15.1)
3.0 (11.4)
2.0 (7.6)
1.0 (3.8)
0.0
0
25(13.9) 50(27.8) 75(41.6) 100(55.6) 125(69.4) 150(83.3)
delta T - Temperature Rise (ºF)
RL75i VC SP(01) 7/2015
FLOW TABLE
Water Flow gpm (l/min)
© 2015 Rinnai Corporation
C U
Low Lead Content
NSF/ANSI 372
SANITATION
RL75i (VC2528FFUD-US)
External Recirculation Pump Control
Water Temperature Control
Controller
Controller Cable
Safety Devices
Clearances from Combustibles (suitable for closet, attic, and crawl space installations)
Clearances from Non-combustibles
Min. / Max. Gas Supply Pressure (sea level)
Manifold Gas Pressure (inches W.C.)
NOx
Rinnai Circ-Logic™: Recirculation program cycles external pump
Simulation feed forward and feedback
MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications) MC-195T-US (optional; for use with Circ-Logic)
Non-polarized two-core cable, minimum 22 AWG
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Top of heater - 6 inches(152mm) Front of heater - 6 inches(152mm)* Sides of heater - 2 inches(51mm)
Top of heater - 2 inches(51mm) Front of heater - 6 inches(152mm)*
Sides of heater - 1/2 inch(13mm)
Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Natural Gas: high fire 2.2” W.C. (5.5mbar) low fire 0.61” W.C. (1.5mbar) Propane Gas: high fire 3.8” W.C. (9.5mbar) low fire 0.87” W.C. (2.2mbar)
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels
Remaining flame (OHS) Thermal fuse Automatic frost protection
Back of heater - 0 inches Ground / bottom - 12 inches(305mm) From vent pipe - 0 inches
Back of heater - 0 inches Ground / bottom - 12 inches(305mm) From vent pipe - 0 inches
Limited Warranty
DIMENSIONS
Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for commercial; All other parts: 5 years*; Labor: 1 year; (* 3 years from date of purchase when used as a recirculating water heater within a hot water recirculation loop, where the water heater is in series with a recirculation system and all recirculating water flows through the water heater, and where an aquastat/thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.
WEIGHT: 45.6 lb (20.7 kg)
14.04 (356.6)
9.27 (235.5)
5.05 (128.1)
0.4~1.8 (10~45) Variable
2.67 (67.8)
DIMENSION
22.95 (583)
A
B
A (GAS)
A (COLD)
A (HOT)
B
C
C
Inches (mm)
1.31 (33.2)
1.93 (49)
1.35 (34.4)
4.21 (106.9)
1.17 (29.8)
E
D
DIMENSION
D
E
F
G
F
Inches (mm)
G
4.33 (110)
2.89 (73.3)
1.85 (47)
3.44 (87.3)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us