Rinnai RL75e Specification

RL75e (VC2528WD-US)
Type of Appliance
Rinnai Model Number Minimum/Maximum Gas Rate (Input) Electrical
Electrical Consumption Ignition System Hot Water Capacity
Temperature
Temperature (without remote) Installation Energy Factor Service Connections
Isolation & Pressure Relief Valves Included
Temperature controlled, continuous flow, gas hot water system
Certified for installation in manufactured (mobile) homes
Forced comb ustion
Energy Star qualified
REU-VC2528WD-US 10,300 - 180,000 BTU/h Appliance: AC 120 Volts - 60 Hz
Controller: DC 12 Volts Normal: 57 w Standby: 2 w Anti-frost protection: 104 w Direct electronic ignition Minimum flow rate: 0.26 GPM
Minimum activation flow rate: 0.4 GPM Maximum flow rate: 7.5 GPM
98° - 120° F (factory default) Maximum temperature is selectable at 120° F or at 140° F; 98° - 160° F available with the MCC-91-2 controller for commercial and hydronic applications
120° F (factory default) or 140° F Outdoor only Natural Gas: 0.82 Propane: 0.82 Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT
Hot water outlet: 3/4 inch MNPT Heavy duty forged brass Webstone Isolator valves EXP E2, certified
to NSF/ANSI 61-8 for potable water
Water Flow Control Minimum/Maximum Water Supply Pressure
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
FLOW TABLE
8.0
Water flow sensor, electronic water control device and fixed by-pass 20 - 150 PSI (recommended 30-80 PSI for maximum performance)
7.0
6.0
5.0
4.0
3.0
2.0
1.0
Water Flow (gpm)
0.0 0 25 50 75 100 125 150
delta T - Temperature Rise (ºF)
© 2012 Rinnai Corporation
RL75e VC SP 3/2012
RL75e (VC2528WD-US)
Water Temperature Control Controller
Controller Cable Safety Devices
Clearances from Combustibles
Clearances from Non-combustibles
* 24 inches required for serviceability
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.) (sea level)
NOx
Simulation feed forward and feedback MC-91-2US (included)
Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications)
Non-polarized two-core cable, minimum 22 AWG
Flame failure - Flame Rod
Boiling protection
Combustion fan rpm check
Over current - glass fuse
Top of heater - 12 inches
Front (Panel) - 24 inches
Front (Exhaust) - 24 inches
Top of heater - 2 inches
Front (Panel) - 0 inches *
Front (Exhaust) - 24 inches
Remaining flame (OHS)
Thermal fuse
Automatic frost protection
Back of heater - 0 inches
Ground / bottom - 12 inches
Sides of heater - 6 inches
Back of heater - 0 inches
Ground / bottom - 2 inches
Sides of heater - 1/8 inch
Natural Gas: min 5” W.C. max 10.5” W.C. Propane Gas: min 8” W.C. max 13.5” W.C.
Natural Gas: high fire 2.2” W.C. low fire 0.61” W.C. Propane Gas: high fire 3.4” W.C. low fire 0.93” W.C.
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels
Limited Warranty
DIMENSIONS
14.04 (356.6)
Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for commercial; All other parts: 5 years*; Labor: 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater, and where an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.
WEIGHT: 43.6 lb (19.8 kg)
0.28 (7.2)
2.23 (56.6)
8.90 (226)
1.14 (29)
22.95 (583)
9.27 (235.5)
0.59 (15)
A
B
C
DIMEN-
SION
A (GAS) 1.31 (33.2) D 4.33 (110)
A (COLD) 1.93 (49) E 2.91 (73.8)
A (HOT) 1.35 (34.4) F 1.61 (40.8)
B 3.96 (100.7) G 2.87 (73) C 1.17 (29.8)
Inches (mm)
E
D
DIMEN-
SION
F
Inches (mm)
G
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us