Rinnai RHFE-750ETRA-P, RHFE-750ETRA-N User Manual

RHFE-750ETRA
Type of Appliance
Rinnai Model Number AFUE (at minimum vent length) AFUE (extended vent of 33 ft [2.2 m] and
no elbows) Gas Rate Input (BTU/hour) Gas Rate Output (BTU/hour) Minimum Gas Supply Pressure Maximum Gas Supply Pressure Electrical Connection Gas Connection Burners Ignition System Exhaust System Temperature Settings
Temperature Control Warm Air Outlet Warranty
Vented gas fireplace heater; Inbuilt only; for residential installation, commercial setting, or manufactured home; not designed for installation in a solid-fuel burning fireplace
RHFE-750ETRA-N (Natural gas) RHFE-750ETRA-P (Propane) 77% 84% 80% 85%
Low - 11,000 High - 29,000 Low - 11,000 High - 28,000 Low - 8,635 High - 21,900 Low - 8,855 High - 21,840
4.3 inch (109 mm) W.C. 9.8 inch (249 mm) W.C.
10.5 inch (267 mm) W.C. 13 inch (330 mm) W.C. AC 120V, 60 Hz Flex line: 3/8 inch flare nut; ball valve: 1/2 inch female x 3/8 inch flare Flame burners Electronic spark ignition Forced combustion, forced convection Low (L): minimum combustion; High (H): maximum combustion;
60° - 80° F in 2° increments (16° - 26° C in 1° increments) Electronic thermistor Bottom front louvers All parts: 2 years from date of purchase
DIMENSIONS - inches (mm)
33 3/16 (842)
FLUE CONNECTION
15 3/4 (400)
GAS CONNECT ION
2 1/4 (57)
14 7/8 (378)
4 15/16 (126)
21 5/16 - 23 5/16 (542 - 592)
2 15/16 (71)
33 3/16 (842)
35 7/16 (900)
B
23 5/8 (600)
10 13/16 (274)
B
27 9/16 (700)
WEIGHT: 154.3 lbs (70 kg)
14 1/2 (369)
26 3/4 (679)
3 5/16 (84)
17 13/16 (453)
25 13/16 (655)
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
© 2011 Rinnai Corporation
750ETRA SP 3/2011
RHFE-750ETRA
LOCATION
Minimum Enclosure Dimensions
Width (w) 33.8 in (860 mm)
Height (h) 26.0 - 26.2 in (660-665 mm)
Depth (d) 15.0 - 16.9 in (380-430 mm)
Minimum Enclosure Dimensions in
a Corner
x 63.8 in (1620 mm) y 45.1 in (1146 mm) z 31.9 in (810 mm)
w
h
d
Clearances for a mantle or decorative overhang
5”
4”
45
3” Minimum
3”
2”
Interior wall
1”
x
y
z
Side view
FASCIAS
Flat Metal - Stainless Steel Front R2701
Radius Glass - Silver Front R2702 Radius Glass - Black Front R2703
VENTING WITH NO EXTENSIONS
Name Kit No. fits walls
Vent Kit A FOT-203
Vent Kit B FOT-204
Wall penetration hole: 3 1/2 in (90 mm) Flue extensions are not authorized to be used with
the FOT-203 and FOT-204 manifolds.
4 1/3 - 9 1/2 inch
(110 - 240 mm)
9 1/2 - 15 3/4 inch
(240 - 400 mm)
Available Fascias (Front Panels)
Description Part Number
Flat Metal - Black Front R2700
FOT-203 / FOT-204
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us