Rinnai MC-100V, BC-100V Operation And Installation Manual

Compatible Rinnai water heater models:
Infinity XR32 HD-200 Infinity XR26 HD-200i Infinity XR24 HD-250 Infinity XR20 HD-250i Infinity XR18 Infinity XR16 Infinity XR26i Infinity XRPlus 26 Infinity XRPlus 20 Efficiency 24
Universal wired controller MC-91 Wireless controller MC502S
MC-100V & BC-100V
Operation / Installation Manual
A guide on how to use and install Rinnai deluxe water controllers
This guide is for the use and installation of Rinnai Deluxe water controller models MC-100V and BC-100V.
These instructions must be used in conjunction with the Rinnai Water Heater Operation / Installation Manual supplied with Rinnai water heaters.
These water controllers are compatible only with the Rinnai water heater and other water controller models shown.
Refer to the table located on page 1 of this manual to confirm the maximum number and combination of controllers that can be fitted to your Rinnai water heater model.
This appliance shall be installed in accordance with:
• Manufacturer’s Installation Instructions
• Current AS/NZS 3000, AS/NZS 3500 & NZS 5261
• Local Regulations and Municipal Building Codes
This appliance must be installed, serviced and removed by an Authorised Person.
Rinnai New Zealand i Operation Manual:01-07
Controllers and water heaters must be installed correctly by an authorised person. The installation of gas, water, and electricity must conform to local regulations.
The installation must also comply with the instructions supplied by Rinnai.
Please keep this instruction booklet in a safe place for future reference.
All dimensions referred to in these instructions are in millimetres, unless otherwise specified.
Excessively hot water is dangerous, especially for young children and the infirm. Rinnai water heaters allow you to control the temperature of hot water to safe levels.
Water temperatures above 55°C can cause severe burns instantly and may even result in death. Those most at risk are children, disabled, elderly and the infirm. Hot water at 65°C (the average hot water temperature in New Zealand) can severely burn a child in less than half a second. At 55°C it takes half a minute.
ALWAYS......
Test the temperature of the water with your elbow before placing your child in the bath, also carefully feel water before bathing or showering yourself.
Supervise children whenever they are in the bathroom.
Make sure that the hot water tap is turned off tightly.
CONSIDER.....
Installing child proof tap covers or child resistant taps (both approaches will prevent a small hand being able to turn on the tap).
Setting your appliance at a maximum temperature of 55°C (Contact Rinnai New Zealand).
NEVER…..
Leave a toddler in the care of another child. They may not understand the need to have the water temperature set at a safe level.
REGULATORY INFORMATION
WARNING ABOUT HOT WATER
Rinnai New Zealand ii Operation Manual:01-07
REGULATORY INFORMATION...................................................................................i
WARNING ABOUT HOT WATER ................................................................................ i
GENERAL WATER CONTROLLER INFORMATION .................................................1
DELUXE WATER CONTROLLERS ............................................................................ 2
ABOUT THE DELUXE KITCHEN WATER CONTROLLER (MC-100V)....................................... 2
HOW TO USE THE DELUXE KITCHEN WATER CONTROLLER (MC-100V) ............................ 2
ABOUT THE DELUXE BATHROOM WATER CONTROLLER (BC-100V) .................................. 4
HOW TO USE THE DELUXE BATHROOM WATER CONTROLLER (BC-100V)........................ 4
OPERATING THE SHOWER SAVER / BATH FILL FUNCTION.................................................. 6
USING MULTIPLE CONTROLLERS............................................................................................ 7
COMBINING UNIVERSAL AND DELUXE CONTROLLERS........................................................ 7
WATER CONTROLLER INSTALLATION...................................................................8
WATER CONTROLLERS............................................................................................................. 8
POSITIONING OF WATER CONTROLLERS .............................................................................. 8
WATER CONTROLLER CABLES ................................................................................................ 8
FITTING THE ‘DELUXE KITCHEN’ WATER CONTROLLER (MC-100V).................................... 8
FITTING THE ‘DELUXE BATHROOM’ WATER CONTROLLER (BC-100V) ............................... 9
CONTACT INFORMATION .......................................................................................13
OPERATION MANUAL
Rinnai New Zealand 1 Operation Manual:01-07
GENERAL WATER CONTROLLER INFORMATION
Temperature water controllers allow precise temperature control by the user. When used correctly, the hot water unit will deliver the selected temperature, even when the water flow is varied, or more than one tap is in use. Each water controller can be individually programmed, however the water heater can only deliver one set temperature at any time. The available temperatures (°C) are as follows:
Kitchen Controller:
37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50, 55°C* (60°C, 65°C, 75°C HD models only )
Bathroom Controller:
Hot Water Delivery: 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50°C Bath fill Delivery: 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48°C
Whilst hot water outlets are open the set temperature may be lowered. However the set temperature cannot then be raised above 43°C. In addition transfer of 'priority' between controllers is not possible. These are safety features.
Suggested temperatures are:
Kitchen 50°C ~ 55°C* Shower 37°C ~ 43°C, Bath fill 39°C ~ 45°C
* Temperature may not be available on all installations. Rinnai water heaters can be programmed to deliver higher temperatures via the kitchen controller. Contact Rinnai for more details.
These temperatures are suggestions only. You may find higher or lower temperatures more comfortable. Maintaining lower temperatures helps save energy. To obtain water temperatures lower than 37°C simply add cold water.
Water controllers are an optional extra. 'Universal' and 'Deluxe' water controllers can be fitted. Universal Controllers allow temperature selection only. Deluxe controllers allow temperature selection, bath fill and have a clock function.
Water controllers allow the water temperature to be set from the various locations where they are installed. The temperature selected will be available to all outlets.
Universal (MC-91-2A) and Deluxe (MC-100V & BC-100V) Controllers - available configuration:
A maximum of 4 water controllers can be fitted. Any combination of the deluxe, universal and wireless controllers can be used with the following limitations.
Only ONE master controller can be installed. This can be MC-100V, a MC-91 (when programmed as a master controller) or a MC502S (wireless) controller.
Up to TWO BC-100V water controllers can be installed.
The FOURTH water controller in any installation MUST BE a MC502S (wireless) or a MC-91.
Rinnai New Zealand 2 Operation Manual:01-07
DELUXE WATER CONTROLLERS
ABOUT THE DELUXE KITCHEN WATER CONTROLLER (MC-100V)
HOW TO USE THE DELUXE KITCHEN WATER CONTROLLER (MC-100V)
Setting The Clock
The clock is a 12 hour AM/PM style display. To set the time press the 'Mode' button twice, this places the controller into clock setting mode, in the digital monitor the word ‘Clock’ will be displayed and the clock digits will flash, if this is the first time the clock has been set the starting time will be AM 12:00.
Use the or buttons to select the desired time, holding these buttons down continuously cycles the digits. When you get close to the time you wish to set, press the button intermittently to avoid going further than the desired time.
Turning on the Controller
If the controller is switched off (No digits other than the clock digits displayed in the digital monitor) press the On/Off button once.
The On/Off and Transfer buttons illuminate to indicate that the hot water unit will be ready to supply hot water once a hot water tap is opened.
If more than one controller is fitted press the ‘Transfer’ button to transfer priority to the desired controller.
The MC-100V controller is not water resistant, avoid direct exposure to water or steam as these conditions may cause damage.
Used to switch the water heater on and off. This button is illuminated when the hot water heating system is on.
ON/OFF BUTTON
DIGITAL
MONITOR
Indicates that the water heater is in operation and delivering hot water.
WATER HEATER
'In Use' INDICATOR
SPEAKER
When in Normal mode these buttons are used to select the water temperature.
In 'Setup' mode these buttons are used to adjust the voice prompt volume and to set the clock.
UP AND DOWN BUTTONS
Used to swith the controller between Normal, Voice or Clock modes.
MODE BUTTON
Indicates the selected hot water temperature.
WATER TEMPERATURE
INDICATOR
Indicates that the Shower Saver / Bath Fill function is operating.
SHOWER SAVER /
BATH FILL INDICATOR
12 Hour AM / PM clock display.
In the event of a fault, codes for
error messages will flash here.
CLOCK
Used to transfer control priority between the temperature controllers. The controller with priority has command of the hot water delivery temperature. This button is illuminated when this controller has priority.
TRANSFER BUTTON
NOTE