Rinnai Infinity Enviro 26, Infinity 32, Infinity 26I, Infinity 26, HD200I User Manual

...
This appliance shall be installed in accordance with:
• Manufacturer’s Installation Instructions
• Current AS/NZS 3000, AS/NZS 3500 & AS/NZS 5601
• Local Regulations and Municipal Building Codes including local OH&S requirements This appliance must be installed, maintained and removed by an Authorised Person. For continued safety of this appliance it must be installed and maintained in
This Appliance complies
with AS 3498:2009
SAI GLOBAL LIC. W208
To Suit Water Heater Models -
INFINITY 32 REU-VRM3237WG INFINITY 26 REU- VRM2626WG INFINITY 26i REU-VRM2632FFUG INFINITY 20 REU-VRM2024WG INFINITY 16 REU-VRM1620WG INFINITY ENVIRO 32 REU-KM3237WD INFINITY ENVIRO 26 REU-KM2635WD B16 REU-VR1620WB B20 REU-VR2024WB B26 REU-VR2626WB HD250e REU-VRM3237WC HD200e REU-VRM2632WC HD200i REU-VRM2632FFUC HDC211e REU-KM3237WDC HDC211i REU-KM3237FFUDC
Operation & Installation Manual
Rinnai Continuous Flow Water Heaters
This page is intentionally blank
2
TABLE OF CONTENTS
REGULATORY INFORMATION..................................................................................4
WARNING ABOUT HOT WATER ...............................................................................4
FEATURES AND BENEFITS ......................................................................................5
IMPORTANT INFORMATION .....................................................................................6
OPERATION WITHOUT CONTROLLERS..................................................................8
GENERAL WATER CONTROL INFORMATION ........................................................9
MAXIMUM DELIVERY TEMPERATURES...................................................................................................9
UNIVERSAL WATER CONTROLLERS ....................................................................11
ABOUT THE UNIVERSAL WATER CONTROLLER (MC-91Q)................................................................. 11
TURNING ON THE WATER CONTROLLER............................................................................................. 11
ADJUSTING TEMPERATURE................................................................................................................... 11
HOW TO USE TWO OR MORE UNIVERSAL WATER CONTROLLERS ................................................. 12
TRANSFERRING PRIORITY ..................................................................................................................... 12
ADJUSTING TEMPERATURE................................................................................................................... 12
DELUXE BATHROOM WATER CONTROLLERS....................................................13
ABOUT THE DELUXE BATHROOM WATER CONTROLLER (BC-100V) ................................................ 13
TURNING ON THE WATER CONTROLLER............................................................................................. 13
SETTING THE SOUND OPTIONS ............................................................................................................ 14
SETTING THE CLOCK .............................................................................................................................. 14
ADJUSTING TEMPERATURE................................................................................................................... 14
OPERATING THE SHOWER SAVER / BATH FILL FUNCTION ............................................................... 15
USING MULTIPLE WATER CONTROLLERS ........................................................................................... 16
COMBINING UNIVERSAL AND DELUXE WATER CONTROLLERS ....................................................... 16
DELUXE KITCHEN WATER CONTROLLERS .........................................................17
ABOUT THE DELUXE KITCHEN WATER CONTROLLER (MC-100V) .................................................... 17
TURNING ON THE WATER CONTROLLER............................................................................................. 17
SETTING THE SOUND OPTIONS ............................................................................................................ 17
SETTING THE CLOCK .............................................................................................................................. 18
ADJUSTING TEMPERATURE................................................................................................................... 18
SMARTSTART® PRE-HEAT OPERATION ..............................................................19
ABOUT THE SMARTSTART® PREHEAT SYSTEM ................................................................................. 19
TROUBLESHOOTING...............................................................................................20
INSTALLATION MANUAL ........................................................................................23
ACCESSORIES ........................................................................................................39
PRODUCT RECORDS .............................................................................................39
CONTACT INFORMATION ......................................................................................40
Rinnai Australia 3 Operation Manual
REGULATORY INFORMATION
Your Rinnai Continuous Flow water heater has been certified by the Australian Gas Association. The A.G.A. Certification Number is shown on the data plate.
This Appliance must be installed correctly by an authorised person. The installation of gas, water, and electricity must conform to local regulations.
The installation must also comply with the instructions supplied by Rinnai.
All dimensions referred to in these instructions are in millimetres, unless otherwise specified.
Please keep this instruction booklet in a safe place for future reference.
Notice to Victorian Consumers
This appliance must be installed by a person licensed with the Plumbing Industry Commission.
Only a licensed person will have insurance protecting their workmanship.
So make sure you use a licensed person to install this appliance and ask for your Compliance Certificate. For Further information contact the Plumbing Industry Commission on 1800 015 129.
WARNING ABOUT HOT WATER
Heated water can be dangerous, especially for young children and the infirm.
Water temperatures above 50°C can cause severe burns instantly and may even result in death.
Those most at risk are children, disabled, elderly and the infirm.
Hot water at 65°C (a very common hot water temperature in Australia) can severely burn a child in less than half a second. At 50°C it takes five minutes.
ALWAYS......
Test the temperature of the water with your elbow before placing your child in the bath, also carefully feel water before bathing or showering yourself.
Supervise children whenever they are in the bathroom.
Make sure that the hot water tap is turned off tightly.
CONSIDER.....
Installing child proof tap covers or child resistant taps (both approaches will prevent a small hand being able to turn on the tap).
Setting your appliance at a maximum temperature of 50°C (Contact Rinnai Australia).
NEVER…..
Leave a toddler in the care of another child. They may not understand the need to have the water temperature set at a safe level.
Rinnai Australia 4 Operation Manual
FEATURES AND BENEFITS
Congratulations on purchasing the latest technology temperature controlled Rinnai continuous flow water heating system.
The Rinnai Continuous Flow water heater products NEVER RUN OUT of hot water. Whilst
electricity, water and gas supplies are connected, hot water is available whenever hot water taps are open.
Built into the main micro-processor is the facility to LIMIT THE MAXIMUM TEMPERATURE of the
hot water supplied. The water temperature may be limited to various values. This is particularly useful when the hot water unit is installed where young children or the infirm may be using the hot water.
The Rinnai Continuous Flow water heater products are power flued appliances. This makes them
COMPACT, saving both floor and wall space.
The temperature of hot water is CONSTANTLY MONITORED by a BUILT-IN SENSOR. If the
temperature of the hot water rises to more than 3°C above the selected temperature the burner is turned OFF and only turned ON again when the temperature falls below the selected temperature.
The burner lights automatically when the hot water tap is opened, and goes out when the tap is
closed. IGNITION IS ELECTRONIC, so there is no pilot light. When the hot water tap is off, no gas is used.
The "Smartstart®" system when fitted can pre-heat the water in the pipe-work between the water
heater and the hot water outlets. This results in water savings and reduces waiting time for heated water at the outlets.
'Deluxe' or 'Universal' Water Controllers are available as an optional extra. Depending on the
models chosen, these offer the following features:
Bath fill function (Deluxe Bathroom Control Only).
Voice Prompting (Deluxe Control Only).
Clock (Deluxe Control Only).
Up to four water controllers can be fitted. See page 10 for details.
Water controller cables are connected easily by the end user using a convenient quick connect system.
Operating NOISE LEVEL IS VERY LOW.
ERROR MESSAGES ARE DISPLAYED on the Water Controllers and Status Monitor*, assisting with
service. *All models in the range covered by this manual have a “Status Monitor”, except B16, B20 & B26.
Rinnai Australia 5 Operation Manual
IMPORTANT INFORMATION
S
O
L
V
E
N
T
Max. 43°C
49°C
50°C
Kitchen
Kitchen
Bathroom
To clean your water controller(s) use a soft damp cloth with a mild detergent.
Do Not use solvents!
Depending on the weather conditions and the length of the pipe between the hot water unit and the outlet in use, there may be a variation between the temperatures displayed at the water controller(s) and the temperature of the water at the outlet.
Whilst hot water outlets are open the set temperature may be lowered. However they cannot then be raised above 43°C. In addition transfer of 'priority' between controllers is not possible. These are safety features.
There is no need to turn the water controller(s) off after use. However, if you prefer to turn the water controller(s) off, selected temperatures to a maximum of 50°C will be stored in the system memory at all times whilst mains power remains connected.
As a safety precaution, if a Kitchen Controller's temperature is set above 50°C, transferring and then returning 'priority' to the Kitchen Controller will result in a default set temperature of 50°C being selected. This is a safety feature.
Rinnai Australia 6 Operation Manual
Do Not push the On/Off button on any Controller when the ‘Red’ water heater ‘In Use’ indicator is illuminated as this will turn off the water heater causing the water to go cold. Someone maybe in the middle of having a shower or filling a bath.
IMPORTANT INFORMATION
NOTE
OFF!
HOT!
Filter
Drain
Gas
Valve
GasColdHot
Turn Water Off
Turn Gas Off
Drain Water
43°C
5
5
°
C
The range of Rinnai continuous flow water heaters referred to in this manual are incompatible with solar water heating systems. A dedicated range of solar compatible continuous flow water heaters is available from Rinnai.
Always check water temperature carefully before use. Refer to the WARNING ABOUT HOT WATER on "page 4" for important safety information.
Do Not touch the unit cover or the flue outlet.
Do Not insert objects into the flue outlet.
Do Not spray water directly into the flue outlet.
Keep, trees, shrubs, etc. well clear of the flue outlet.
On colder days steam may discharged from the flue outlet. This condition is normal for high efficiency appliances and does not indicate a fault.
At low water flows, the hot water unit may extinguish without warning. Opening the tap further will restart the appliance.
Do Not spray aerosols in the vicinity of this appliance while it is in operation.
Do Not use or store flammable materials in or near this appliance.
Do Not place articles on or against this appliance.
Do Not modify this appliance.
Do Not store pool chemicals near this appliance.
If freezing conditions are expected, turn off water and gas and drain all water from the appliance. If power and the automatic frost protection are connected, freezing will be prevented. (Anti-frost protection is fitted as standard equipment on External units and is available as an optional extra on Internal Units).
The delivered water temperature is controlled automatically. The flow may vary depending on the delivery temperature selected and the ambient water temperature.
Rinnai Australia 7 Operation Manual
OPERATION WITHOUT CONTROLLERS
HOTHOT
COLDCOLD
ON!ON!
ON!ON!
HOTHOT
COLDCOLD
OFF!OFF!
OFF!OFF!
CAUTION
Rinnai Continuous Flow water heater products do not use a pilot light.
When installed and operated without water controllers, the opening of any hot water tap will automatically start the appliance.
Once water is flowing through the appliance the burner will be ignited by electronic ignition.
When the hot water tap is closed and water flowing through the appliance has stopped the burner flame will extinguish.
Heated water can be dangerous, especially for young children and the infirm.
Water temperatures above 50°C can cause severe burns instantly and may even result in death.
Those most at risk are children, disabled, elderly and the infirm.
Hot water at 65°C (a very common hot water temperature in Australia) can severely burn a child in less than half a second. At 50°C it takes five minutes.
ALWAYS......
Test the temperature of the water with your elbow before placing your child in the bath, also carefully feel water before bathing or showering yourself.
Supervise children whenever they are in the bathroom.
Make sure that the hot water tap is turned off tightly.
CONSIDER.....
Installing child proof tap covers or child resistant taps (both approaches will prevent a small hand being able to turn on the tap).
Setting your appliance at a maximum temperature of 50°C (Contact Rinnai Australia).
NEVER…..
Leave a toddler in the care of another child. They may not understand the need to have the water temperature set at a safe level.
Rinnai Australia 8 Operation Manual
GENERAL WATER CONTROL INFORMATION
NOTE
MAXIMUM DELIVERY TEMPERATURES
Rinnai continuous flow water heaters are factory pre-set to various maximum delivery temperatures depending on model and their intended application. For the majority of applications, the factory pre­set temperature is appropriate. In the unlikely event this is not the case this setting can be increased or decreased by an authorised person such as a licensed plumber.
This does not apply to “50 degree compliant” or “Solar” models. To meet the regulatory requirements for these models, the maximum delivery temperature is factory set and sealed.
Factory pre-set delivery temperatures for the various models are as follows:
MODEL NUMBER
Note: The model number is
written on the dataplate on
the left hand side of
appliance
REU- VRM1620WG INFINITY 16 60 Yes
REU- VRM2024WG INFINITY 20 60 Yes
REU- VRM2626WG INFINITY 26 60 Yes
REU- VRM2632FFUG INFINITY 26 Internal 60 Yes
REU- VRM3237WG INFINITY 32 60 Yes
REU- KM2635WD ENVIRO 26 60 Yes
REU- KM3237WD ENVIRO 32 60 Yes
REU- VRM1620WG-50 INFINITY 16 - 50°C Compliant 50 No
REU- VRM2024WG-50 INFINITY 20 - 50°C Compliant 50 No
REU- VRM2626WG-50 INFINITY 26 - 50°C Compliant 50 No
REU- VRM3237WG-50 INFINITY 32 - 50°C Compliant 50 No
REU- VRM2632FFUG-50 INFINITY 26 Internal - 50°C Compliant 50 No
MODEL NAME FACTORY
“PRE-SET”
MAXIMUM DELIVERY
TEMPERATURE
(°C)
CAN FACTORY
“PRE-SET”
MAXIMUM DELIVERY
TEMPERATURE BE CHANGED BY AN AUTHORISED
PERSON?
REU- VR1620WB B16 60 Yes
REU- VR2024WB B20 60 Yes
REU- VR2626WB B26 60 Yes
REU- VR1620WB-50 B16 - 50°C Compliant 50 No
REU- VR2024WB-50 B20 - 50°C Compliant 50 No
REU- VR2626WB-50 B26 - 50°C Compliant 50 No
REU- VRM2632WC HD200e 75 Yes
REU- VRM2632FFUC HD200i 75 Yes
REU- VRM3237WC HD250e 75 Yes
REU- KM3237WDC HDC211e 75 Yes
REU- KM3237FFUDC HDC211i 75 Yes
REU- VRM2632WC-50 HD200e - 50°C Compliant 50 No
REU- VRM2632FFUC-50 HD200i - 50°C Compliant 50 No
REU- VRM3237WC-50 HD250e - 50°C Compliant 50 No
REU- KM3237WDC-50 HDC211e - 50°C Compliant 50 No
REU- KM3237FFUDC-50 HDC211i - 50°C Compliant 50 No
Rinnai Australia 9 Operation Manual
GENERAL WATER CONTROL INFORMATION
Water controllers allow precise temperature control by the user. When used correctly, the hot water unit will deliver the selected temperature, even when the water flow is varied, or more than one tap is in use. Each water controller can be individually programmed, however the water heater can only deliver one set temperature at any time. The available temperatures (°C) are as follows:
Kitchen Controller:
37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50, 55*, 60*, 65* and 75°C*
Bathroom Controller:
Hot Water Delivery: 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50°C Bath fill Delivery: 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48°C
Whilst hot water outlets are open the set temperature may be lowered. However the set temperature cannot then be raised above 43°C. In addition, transfer of 'priority' between water controllers is not possible. These are safety features.
Suggested temperatures are:
Kitchen 50°C ~ 55°C* Shower 37°C ~ 43°C, Bath fill 39°C ~ 45°C
* Temperature may not be available refer to “Delivery Temperatures”.
These temperatures are suggestions only. You may find higher or lower temperatures more comfortable. Maintaining lower temperatures helps save energy. To obtain water temperatures lower than 37°C simply add cold water.
Water controllers are an optional extra. 'Universal' and 'Deluxe' water controllers can be fitted. Universal water controllers allow temperature selection only. Deluxe water controllers allow temperature selection, shower saver / bath fill and have a clock function.
Water controllers allow the water temperature to be set from the various locations where they are installed. The temperature selected will be available to all outlets.
Universal (MC-91Q) and Deluxe (MC/BC-100V) Water Controllers - available configurations:
All
Models
A maximum of 4 water controllers can be fitted. Any combination of both deluxe and universal controllers can be used with the following provisions:
Only ONE
Up to TWO
The FOURTH
MC-100V water controller can be installed.
BC-100V water controllers can be installed.
water controllers in any installation MUST BE a MC-91Q.
Rinnai Australia 10 Operation Manual
UNIVERSAL WATER CONTROLLERS
Indicates that the Smartstart® preheater (when fitted)is activated.
Used to start and stop the Smartstart® preheat unit (when fitted), See Smartstart® Operation on page 19.
Used to switch the water heater on and off.
Used to transfer control priority between the temperature controllers. The controller with priority has command of the hot water delivery temperature.
Indicates that a water heater is in operation and delivering hot water.
Indicates the temperature selec
ted. Error message flash in
event of a fault.
Used to select water temperature.
Indicates if this temperature controller is in control of water delivery temperature.
WATER HEATER
'In Use' INDICATOR
DIGITAL MONITOR
TEMPER ATURE
CONTRO L BUTTONS
CONTROLLER ON INDICATOR
TRANSFER BUTTON
PREHE AT BUTTON
PREHE AT INDICATOR
ON/OFF BUTTON
Please read the ‘Operation/Installation’ Manual carefully to ensure safe and correct operation.
Check the ‘ON indicator’ light is lit before turning on the tap.
WARNING
HOTHOT
COLDCOLD
ON!ON!
CAUTION
NOTE
ABOUT THE UNIVERSAL WATER CONTROLLER (MC-91Q)
TURNING ON THE WATER CONTROLLER
If the water controller is switched off (No digits displayed in the digital monitor window) press the On/Off button once.
The ON indicator will illuminate, indicating that the hot water unit will be ready to supply hot water once a hot water tap is opened.
ADJUSTING TEMPERATURE
Select the desired temperature using the 'Hot water temp' or
buttons until the required temperature is displayed on the
digital monitor.
To operate the hot water unit, open any hot water tap. This will automatically light the burner providing hot water. The water heater ‘In Use’ indicator will illuminate on the water controller.
Once the hot water is running, if the set temperature is either too hot or cold press the 'Hot water temp' or buttons until the desired temperature is reached.
CHECK WATER TEMPERATURE BEFORE USE. A parent or carer should always check the temperature before a child is placed in contact with hot water, see page 4.
Whilst hot water outlets are open the set temperature may be lowered. However they cannot then be raised above 43°C. In addition, transfer of 'priority' between controllers is not possible. These are safety features.
Rinnai Australia 11 Operation Manual
The 'beep' sound can be muted by pressing the 'Hot water temp' Up and Down buttons simultaneously for more than 3 seconds.
UNIVERSAL WATER CONTROLLERS
HOTHOT
COLDCOLD
ON!ON!
CAUTION
NOTE
HOW TO USE TWO OR MORE UNIVERSAL WATER CONTROLLERS
TURNING ON THE WATER CONTROLLERS
If the controllers are switched off (No digits displayed in the digital monitor window) press the On/Off button once at any controller.
The ON indicator on the desired controller will illuminate, indicating that the hot water unit will be ready to supply hot water once a hot water tap is opened.
TRANSFERRING PRIORITY
An illuminated On/Off indicator confirms that the desired controller is in control of the water delivery temperature, if the On/Off indicator is not illuminated press the TRANSFER button once.
The On/Off indicator on the controller will now illuminate indicating that hot water temperature control has now been transferred to this controller and that the hot water unit will be ready to supply hot water once a hot water tap is opened.
ADJUSTING TEMPERATURE
Select the desired temperature using the 'Hot water temp' or
buttons until the required temperature is displayed on the
digital monitor.
To operate the hot water unit, open any hot water tap. This will automatically light the burner providing hot water. The water heater ‘In Use’ indicator will illuminate on the water controller.
Once the hot water is running, if the set temperature is either too hot or cold press the 'Hot water temp' or buttons until the desired temperature is reached.
CHECK WATER TEMPERATURE BEFORE USE. A parent or carer should always check the temperature before a child is placed in contact with hot water, see page 4.
Whilst hot water outlets are open the set temperature may be lowered. However they cannot then be raised above 43°C. In addition transfer of 'priority' between controllers is not possible. These are safety features.
Temperatures higher than 50ºC should not be able to be selected on controllers installed in bathrooms, ensuites or toilets. This is to help reduce the risk of burns from hot water. If this is not the case, the controllers have been incorrectly installed. CONTACT YOUR INSTALLER.
The temperature of outgoing hot water is constantly monitored by a built-in sensor. If the temperature of the outgoing hot water rises to more than 3°C above the selected temperature shown on the digital monitor or the pre-set limit when water controllers are not fitted, the burner will automatically go out. The ‘in use’ indicator will also go out. The burner will ignite again once the outgoing hot water temperature falls to that shown on the digital monitor (or the pre-set limit of the appliance).
Rinnai Australia 12 Operation Manual
Loading...
+ 28 hidden pages