Rinnai REU-VRM3237WG, REU- VRM2626WG, REU-VRM2632FFUG, INFINITY 20, REU-VRM2024WG User Manual

...
To Suit Water Heater Models -
INFINITY 32
REU-VRM3237WG INFINITY 26 REU- VRM2626WG INFINITY 26i REU-VRM2632FFUG INFINITY 20 REU-VRM2024WG INFINITY 16 REU-VRM1620WG INFINITY ENVIRO 32 REU-KM3237WD INFINITY ENVIRO 26 REU-KM2635WD B16 REU-VR1620WB B20 REU-VR2024WB B26 REU-VR2626WB HD250e REU-VRM3237WC HD200e REU-VRM2632WC HD200i REU-VRM2632FFUC HDC211e REU-KM3237WDC HDC211i REU-KM3237FFUDC
Operation / Installation
Manual
Rinnai Continuous Flow Water Heaters
This appliance shall be installed in accordance with:
• Manufacturer’s Installation Instructions
• Current AS/NZS 3000, AS/NZS 3500 & AS/NZS 5601
• Local Regulations and Municipal Building Codes including local OH&S requirements This appliance must be installed, maintained and removed by an Authorised Person. For continued safety of this appliance it must be installed operated and maintained
in accordance with the manufacturers instructions.
This Appliance complies
with AS 3498:2009
SAI GLOBAL LIC. W208
TABLE OF CONTENTS
REGULATORY INFORMATION..................................................................................1
WARNING ABOUT HOT WATER ...............................................................................1
FEATURES AND BENEFITS ......................................................................................2
IMPORTANT INFORMATION .....................................................................................3
OPERATION WITHOUT CONTROLLERS..................................................................5
GENERAL WATER CONTROL INFORMATION ........................................................6
MAXIMUM DELIVERY TEMPERATURES...................................................................................................6
UNIVERSAL WATER CONTROLLERS ......................................................................8
ABOUT THE UNIVERSAL WATER CONTROLLER (MC-91Q)................................................................... 8
TURNING ON THE WATER CONTROLLER............................................................................................... 8
ADJUSTING TEMPERATURE..................................................................................................................... 8
HOW TO USE TWO OR MORE UNIVERSAL WATER CONTROLLERS ................................................... 9
TRANSFERRING PRIORITY ....................................................................................................................... 9
ADJUSTING TEMPERATURE..................................................................................................................... 9
DELUXE BATHROOM WATER CONTROLLERS....................................................10
ABOUT THE DELUXE BATHROOM WATER CONTROLLER (BC-100V) ................................................ 10
TURNING ON THE WATER CONTROLLER............................................................................................. 10
SETTING THE SOUND OPTIONS ............................................................................................................ 11
SETTING THE CLOCK .............................................................................................................................. 11
ADJUSTING TEMPERATURE................................................................................................................... 11
OPERATING THE SHOWER SAVER / BATH FILL FUNCTION ............................................................... 12
USING MULTIPLE WATER CONTROLLERS ........................................................................................... 13
COMBINING UNIVERSAL AND DELUXE WATER CONTROLLERS ....................................................... 13
DELUXE KITCHEN WATER CONTROLLERS .........................................................14
ABOUT THE DELUXE KITCHEN WATER CONTROLLER (MC-100V) .................................................... 14
TURNING ON THE WATER CONTROLLER............................................................................................. 14
SETTING THE SOUND OPTIONS ............................................................................................................ 14
SETTING THE CLOCK .............................................................................................................................. 15
ADJUSTING TEMPERATURE................................................................................................................... 15
SMARTSTART® PRE-HEAT OPERATION ..............................................................16
ABOUT THE SMARTSTART® PREHEAT SYSTEM ................................................................................. 16
TROUBLESHOOTING...............................................................................................17
INSTALLATION MANUAL ........................................................................................20
ACCESSORIES ........................................................................................................36
PRODUCT RECORDS .............................................................................................36
CONTACT INFORMATION ......................................................................................37
Rinnai Australia i Operation Manual
REGULATORY INFORMATION
Your Rinnai Continuous Flow water heater has been certified by the Australian Gas Association. The A.G.A. Certification Number is shown on the data plate.
This Appliance must be installed correctly by an authorised person. The installation of gas, water, and electricity must conform to local regulations.
The installation must also comply with the instructions supplied by Rinnai.
All dimensions referred to in these instructions are in millimetres, unless otherwise specified.
Please keep this instruction booklet in a safe place for future reference.
Notice to Victorian Consumers
This appliance must be installed by a person licensed with the Plumbing Industry Commission.
Only a licensed person will have insurance protecting their workmanship.
So make sure you use a licensed person to install this appliance and ask for your Compliance Certificate. For Further information contact the Plumbing Industry Commission on 1800 015 129.
WARNING ABOUT HOT WATER
Heated water can be dangerous, especially for young children and the infirm.
Water temperatures above 50°C can cause severe burns instantly and may even result in death.
Those most at risk are children, disabled, elderly and the infirm.
Hot water at 65°C (a very common hot water temperature in Australia) can severely burn a child in less than half a second. At 50°C it takes five minutes.
ALWAYS......
Test the temperature of the water with your elbow before placing your child in the bath, also carefully feel water before bathing or showering yourself.
Supervise children whenever they are in the bathroom.
Make sure that the hot water tap is turned off tightly.
CONSIDER.....
Installing child proof tap covers or child resistant taps (both approaches will prevent a small hand being able to turn on the tap).
Setting your appliance at a maximum temperature of 50°C (Contact Rinnai Australia).
NEVER…..
Leave a toddler in the care of another child. They may not understand the need to have the water temperature set at a safe level.
Rinnai Australia 1 Operation Manual
FEATURES AND BENEFITS
Congratulations on purchasing the latest technology temperature controlled Rinnai continuous flow water heating system.
The Rinnai Continuous Flow water heater products NEVER RUN OUT of hot water. Whilst
electricity, water and gas supplies are connected, hot water is available whenever hot water taps are open.
Built into the main micro-processor is the facility to LIMIT THE MAXIMUM TEMPERATURE of the
hot water supplied. The water temperature may be limited to various values. This is particularly useful when the hot water unit is installed where young children or the infirm may be using the hot water.
The Rinnai Continuous Flow water heater products are power flued appliances. This makes them
COMPACT, saving both floor and wall space.
The temperature of hot water is CONSTANTLY MONITORED by a BUILT-IN SENSOR. If the
temperature of the hot water rises to more than 3°C above the selected temperature the burner is turned OFF and only turned ON again when the temperature falls below the selected temperature.
The burner lights automatically when the hot water tap is opened, and goes out when the tap is
closed. IGNITION IS ELECTRONIC, so there is no pilot light. When the hot water tap is off, no gas is used.
The "Smartstart®" system when fitted can pre-heat the water in the pipe-work between the water
heater and the hot water outlets. This results in water savings and reduces waiting time for heated water at the outlets.
'Deluxe' or 'Universal' Water Controllers are available as an optional extra. Depending on the
models chosen, these offer the following features:
Bath fill function (Deluxe Bathroom Control Only).
Voice Prompting (Deluxe Control Only).
Clock (Deluxe Control Only).
Up to four water controllers can be fitted. See page 7 for details.
Water controller cables are connected easily by the end user using a convenient quick connect system.
Operating NOISE LEVEL IS VERY LOW.
ERROR MESSAGES ARE DISPLAYED on the Water Controllers and Status Monitor*, assisting with
service. *All models in the range covered by this manual have a “Status Monitor”, except B16, B20 & B26.
Rinnai Australia 2 Operation Manual
IMPORTANT INFORMATION
NOTE
OFF!
HOT!
Filter
Drain
Gas
Valve
GasColdHot
Turn Water Off
Turn Gas Off
Drain Water
43°C
5
5
°
C
The range of Rinnai continuous flow water heaters referred to in this manual are incompatible with solar water heating systems. A dedicated range of solar compatible continuous flow water heaters is available from Rinnai.
Always check water temperature carefully before use. Refer to the WARNING ABOUT HOT WATER on "page 1" of this manual for important safety information.
Do Not touch the unit cover or the flue outlet. Do Not insert objects into the flue outlet.
On colder days steam may discharged from the flue outlet. This condition is normal for high efficiency appliances and does not indicate a fault.
At low water flows, the hot water unit may extinguish without warning. Opening the tap further will restart the appliance.
Keep flammable materials, spray cans, fuel containers, pool chemicals, trees, shrubs, etc. well clear of the flue outlet.
Do Not spray water directly into the flue terminal.
The delivered water temperature is controlled automatically. The flow may vary depending on the delivery temperature selected and the ambient water temperature.
If freezing conditions are expected, turn off water and gas and drain all water from the appliance. If power and the automatic frost protection are connected, freezing will be prevented. (Anti-frost protection is fitted as standard equipment on External units and is available as an optional extra on Internal Units).
Rinnai Australia 3 Operation Manual
IMPORTANT INFORMATION
S
O
L
V
E
N
T
Max. 43°C
49°C
50°C
Kitchen
Kitchen
Bathroom
To clean your water controller(s) use a soft damp cloth with a mild detergent.
Do Not use solvents!
Depending on the weather conditions and the length of the pipe between the hot water unit and the outlet in use, there may be a variation between the temperatures displayed at the water controller(s) and the temperature of the water at the outlet.
Whilst hot water outlets are open the set temperature may be lowered. However they cannot then be raised above 43°C. In addition transfer of 'priority' between controllers is not possible. These are safety features.
There is no need to turn the water controller(s) off after use. However, if you prefer to turn the water controller(s) off, selected temperatures to a maximum of 50°C will be stored in the system memory at all times whilst mains power remains connected.
As a safety precaution, if a Kitchen Controller's temperature is set above 50°C, transferring and then returning 'priority' to the Kitchen Controller will result in a default set temperature of 50°C being selected. This is a safety feature.
Rinnai Australia 4 Operation Manual
Do Not push the On/Off button on any Controller when the ‘Red’ water heater ‘In Use’ indicator is illuminated as this will turn off the water heater causing the water to go cold. Someone maybe in the middle of having a shower or filling a bath.
OPERATION WITHOUT CONTROLLERS
HOTHOT
COLDCOLD
ON!ON!
ON!ON!
HOTHOT
COLDCOLD
OFF!OFF!
OFF!OFF!
CAUTION
Rinnai Continuous Flow water heater products do not use a pilot light.
When installed and operated without water controllers, the opening of any hot water tap will automatically start the appliance.
Once water is flowing through the appliance the burner will be ignited by electronic ignition.
When the hot water tap is closed and water flowing through the appliance has stopped the burner flame will extinguish.
Heated water can be dangerous, especially for young children and the infirm.
Water temperatures above 50°C can cause severe burns instantly and may even result in death.
Those most at risk are children, disabled, elderly and the infirm.
Hot water at 65°C (a very common hot water temperature in Australia) can severely burn a child in less than half a second. At 50°C it takes five minutes.
ALWAYS......
Test the temperature of the water with your elbow before placing your child in the bath, also carefully feel water before bathing or showering yourself.
Supervise children whenever they are in the bathroom.
Make sure that the hot water tap is turned off tightly.
CONSIDER.....
Installing child proof tap covers or child resistant taps (both approaches will prevent a small hand being able to turn on the tap).
Setting your appliance at a maximum temperature of 50°C (Contact Rinnai Australia).
NEVER…..
Leave a toddler in the care of another child. They may not understand the need to have the water temperature set at a safe level.
Rinnai Australia 5 Operation Manual
GENERAL WATER CONTROL INFORMATION
NOTE
MAXIMUM DELIVERY TEMPERATURES
Rinnai continuous flow water heaters are factory pre-set to various maximum delivery temperatures depending on model and their intended application. For the majority of applications, the factory pre­set temperature is appropriate. In the unlikely event this is not the case this setting can be increased or decreased by an authorised person such as a licensed plumber.
This does not apply to “50 degree compliant” or “Solar” models. To meet the regulatory requirements for these models, the maximum delivery temperature is factory set and sealed.
Factory pre-set delivery temperatures for the various models are as follows:
MODEL NUMBER
Note: The model number is
written on the dataplate on
the left hand side of
appliance
REU- VRM1620WG INFINITY 16 60 Yes
REU- VRM2024WG INFINITY 20 60 Yes
REU- VRM2626WG INFINITY 26 60 Yes
REU- VRM2632FFUG INFINITY 26 Internal 60 Yes
REU- VRM3237WG INFINITY 32 60 Yes
REU- KM2635WD ENVIRO 26 60 Yes
REU- KM3237WD ENVIRO 32 60 Yes
REU- VRM1620WG-50 INFINITY 16 - 50°C Compliant 50 No
REU- VRM2024WG-50 INFINITY 20 - 50°C Compliant 50 No
REU- VRM2626WG-50 INFINITY 26 - 50°C Compliant 50 No
REU- VRM3237WG-50 INFINITY 32 - 50°C Compliant 50 No
REU- VRM2632FFUG-50 INFINITY 26 Internal - 50°C Compliant 50 No
REU- VR1620WB B16 60 Yes
REU- VR2024WB B20 60 Yes
REU- VR2626WB B26 60 Yes
REU- VR1620WB-50 B16 - 50°C Compliant 50 No
REU- VR2024WB-50 B20 - 50°C Compliant 50 No
REU- VR2626WB-50 B26 - 50°C Compliant 50 No
MODEL NAME FACTORY
“PRE-SET”
MAXIMUM DELIVERY
TEMPERATURE
(°C)
CAN FACTORY
TEMPERATURE BE CHANGED BY AN AUTHORISED
“PRE-SET”
MAXIMUM DELIVERY
PERSON?
REU- VRM2632WC HD200e 75 Yes
REU- VRM2632FFUC HD200i 75 Yes
REU- VRM3237WC HD250e 75 Yes
REU- KM3237WDC HDC211e 75 Yes
REU- KM3237FFUDC HDC211i 75 Yes
REU- VRM2632WC-50 HD200e - 50°C Compliant 50 No
REU- VRM2632FFUC-50 HD200i - 50°C Compliant 50 No
REU- VRM3237WC-50 HD250e - 50°C Compliant 50 No
REU- KM3237WDC-50 HDC211e - 50°C Compliant 50 No
REU- KM3237FFUDC-50 HDC211i - 50°C Compliant 50 No
Rinnai Australia 6 Operation Manual
GENERAL WATER CONTROL INFORMATION
Remote water controllers allow precise temperature control by the user. When used correctly, the hot water unit will deliver the selected temperature, even when the water flow is varied, or more than one tap is in use. Each water controller can be individually programmed, however the water heater can only deliver one set temperature at any time. The available temperatures (°C) are as follows:
Kitchen Controller:
37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50, 55*, 60*, 65* and 75°C*
Bathroom Controller:
Hot Water Delivery: 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50°C Bath fill Delivery: 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48°C
Whilst hot water outlets are open the set temperature may be lowered. However the set temperature cannot then be raised above 43°C. In addition, transfer of 'priority' between water controllers is not possible. These are safety features.
Suggested temperatures are:
Kitchen 50°C ~ 55°C* Shower 37°C ~ 43°C, Bath fill 39°C ~ 45°C
* Temperature may not be available refer to “Delivery Temperatures”.
These temperatures are suggestions only. You may find higher or lower temperatures more comfortable. Maintaining lower temperatures helps save energy. To obtain water temperatures lower than 37°C simply add cold water.
Water controllers are an optional extra. 'Universal' and 'Deluxe' water controllers can be fitted. Universal water controllers allow temperature selection only. Deluxe water controllers allow temperature selection, shower saver / bath fill and have a clock function.
Water controllers allow the water temperature to be set from the various locations where they are installed. The temperature selected will be available to all outlets.
Universal (MC-91Q) and Deluxe (MC/BC-100V) Water Controllers - available configurations:
A maximum of 4 water controllers can be fitted. Any combination of both deluxe and universal controllers can be used with the following provisions:
All
Models
Only ONE
Up to TWO
The FOURTH
MC-100V water controller can be installed.
BC-100V water controllers can be installed.
water controllers in any installation MUST BE a MC-91Q.
Rinnai Australia 7 Operation Manual
UNIVERSAL WATER CONTROLLERS
Indicates that the Smartstart® preheater (when fitted)is activated.
Used to start and stop the Smartstart® preheat unit (when fitted), See Smartstart® Operation on page 16.
Used to switch the water heater on and off.
Used to transfer control priority between the temperature controllers. The controller with priority has command of the hot water delivery temperature.
Indicates that a water heater is in operation and delivering hot water.
Indicates the temperature selected. Error message flash in event of a fault.
Used to select water temperature.
Indicates if this temperature controller is in control of water delivery temperature.
WATER HEATER
'In Use' INDICATOR
DIGITAL MONITOR
TEMPER ATURE
CONTRO L BUTTONS
CONTROLLER ON INDICATOR
TRANSFER BUTTON
PREHE AT BUTTON
PREHEAT INDICATOR
ON/OFF BUTTON
Please read the ‘Operation/Installation’ Manual carefully to ensure safe and correct operation.
Check the ‘ON indicator’ light is lit before turning on the tap.
WARNING
HOTHOT
COLDCOLD
ON!ON!
CAUTION
NOTE
ABOUT THE UNIVERSAL WATER CONTROLLER (MC-91Q)
TURNING ON THE WATER CONTROLLER
If the water controller is switched off (No digits displayed in the digital monitor window) press the On/Off button once.
The ON indicator will illuminate, indicating that the hot water unit will be ready to supply hot water once a hot water tap is opened.
ADJUSTING TEMPERATURE
Select the desired temperature using the 'Hot water temp' or
buttons until the required temperature is displayed on the
digital monitor.
To operate the hot water unit, open any hot water tap. This will automatically light the burner providing hot water. The water heater ‘In Use’ indicator will illuminate on the water controller.
Once the hot water is running, if the set temperature is either too hot or cold press the 'Hot water temp' or buttons until the desired temperature is reached.
CHECK WATER TEMPERATURE BEFORE USE. A parent or carer should always check the temperature before a child is placed in contact with hot water, see page 5.
Whilst hot water outlets are open the set temperature may be lowered. However they cannot then be raised above 43°C. In addition, transfer of 'priority' between controllers is not possible. These are safety features.
Rinnai 8 Operation Manual
The 'beep' sound can be muted by pressing the 'Hot water temp' Up and Down buttons simultaneously for more than 3 seconds.
UNIVERSAL WATER CONTROLLERS
HOTHOT
COLDCOLD
ON!ON!
CAUTION
NOTE
HOW TO USE TWO OR MORE UNIVERSAL WATER CONTROLLERS
TURNING ON THE WATER CONTROLLERS
If the controllers are switched off (No digits displayed in the digital monitor window) press the On/Off button once at any controller.
The ON indicator on the desired controller will illuminate, indicating that the hot water unit will be ready to supply hot water once a hot water tap is opened.
TRANSFERRING PRIORITY
An illuminated On/Off indicator confirms that the desired controller is in control of the water delivery temperature, if the On/Off indicator is not illuminated press the TRANSFER button once.
The On/Off indicator on the controller will now illuminate indicating that hot water temperature control has now been transferred to this controller and that the hot water unit will be ready to supply hot water once a hot water tap is opened.
ADJUSTING TEMPERATURE
Select the desired temperature using the 'Hot water temp' or
buttons until the required temperature is displayed on the
digital monitor.
To operate the hot water unit, open any hot water tap. This will automatically light the burner providing hot water. The water heater ‘In Use’ indicator will illuminate on the water controller.
Once the hot water is running, if the set temperature is either too hot or cold press the 'Hot water temp' or buttons until the desired temperature is reached.
CHECK WATER TEMPERATURE BEFORE USE. A parent or carer should always check the temperature before a child is placed in contact with hot water, see page 5.
Whilst hot water outlets are open the set temperature may be lowered. However they cannot then be raised above 43°C. In addition transfer of 'priority' between controllers is not possible. These are safety features.
Temperatures higher than 50ºC should not be able to be selected on controllers installed in bathrooms, ensuites or toilets. This is to help reduce the risk of burns from hot water. If this is not the case, the controllers have been incorrectly installed. CONTACT YOUR INSTALLER.
The temperature of outgoing hot water is constantly monitored by a built-in sensor. If the temperature of the outgoing hot water rises to more than 3°C above the selected temperature shown on the digital monitor or the pre-set limit when water controllers are not fitted, the burner will automatically go out. The ‘in use’ indicator will also go out. The burner will ignite again once the outgoing hot water temperature falls to that shown on the digital monitor (or the pre-set limit of the appliance).
Rinnai 9 Operation Manual
DELUXE BATHROOM WATER CONTROLLERS
Used to transfer control priority between the Water Controllers. The controller with priority has command of the hot water delivery temperature. This button is illuminated when this controller has priority.
TRANSFER BUTTON
SPEAKER
Used to start and stop the Smartstart® preheat unit (when fitted), See Smartstart® Operation on page 16.
This button is illuminated when the Smartstart® preheater (when fitted) is activated.
PREHE AT BUTTON
Indicates the selected hot water temperature.
WATER TEMPER ATURE
INDICATOR
Indicates that the Shower Saver / Bath Fill function has been selected and that a shower is running or the bath is filling.
SHOWER SAVER /
BATH FILL INDICATOR
12 Hour AM / PM clock display.
Indicates how much water remains to flow for the selected Shower Saver / Bath Fill volume, decreasing while shower runs or bath fills.
In the event of a fault, error message codes will flash here.
CLOCK & REMAINING WATER
VOLUME INDICATOR
In Normal and Shower Saver / Bath Fill modes these buttons are used to select the water temperature.
In 'Clock' mode these button are used to set the clock.
TEMPERATURE BUTTONS
Indicates Shower Saver / Bath Fill volume selected.
WATER LEVEL INDICATOR
Used to select Shower Saver / Bath Fill volumes.
WATER VOLUME BUTTONS
Used to select the voice and audible tone options.
SOUND VOLUME BUTTON
Used to select Shower Saver / Bath Fill function. This button is illuminated when the Shower Saver / Bath Fill function is selected.
Used select clock setting mode.
CLOCK SETTING BUTTON
SHOWER SAVER /
BATH FILL BUTTON
Used to switch the water heater on and off. This button is illuminated when the hot water heating system is on.
ON/OFF BUTTON
Indicatesthatthewaterheaterisin operation and delivering hot water.
WATER HEATER
'In Use' INDICATOR
DIGITAL
MONITOR
NOTE
ABOUT THE DELUXE BATHROOM WATER CONTROLLER (BC-100V)
TURNING ON THE WATER CONTROLLER
If the controller is switched off (No digits other than the clock digits displayed in the digital monitor) press the On/Off button once.
The On/Off and Transfer buttons illuminate to indicate that the hot water unit will be ready to supply hot water once a hot water tap is opened.
If more than one controller is fitted press the ‘Transfer’
button to transfer priority to the desired controller.
Rinnai Australia 10 Operation Manual
Refer to page 7 to confirm the maximum number and combination of controllers that can be fitted to your Water Heater model.
Avoid getting water directly in the speaker as this may cause damage.
DELUXE BATHROOM WATER CONTROLLERS
NOTE
HOTHOT
COLDCOLD
ON!ON!
NOTE
CAUTION
SETTING THE SOUND OPTIONS
To set the sound options press the 'Sound Volume' button and select the desired audible setting as follows:
Voice High, Med, Low or Off, sets the voice prompt volume but does not affect the audible tones. Sound OFF, mutes all voice prompts and audible tones.
Press any of the or buttons to return to normal mode, if no buttons are pressed for a period of approximately 10 seconds the controller will return to normal mode
SETTING THE CLOCK
The clock is a 12 hour AM/PM style display.
To set the time press the 'Clock' button once, this places the controller into clock setting mode, in the digital monitor the clock digits will flash, if this is the first time the clock has been set the starting time will be AM 12:00.
Use the ‘Temperature’ or buttons to select the desired time, holding these buttons down continuously cycles the digits. When you get close to the time you wish to set, press the button intermittently to avoid going further than the desired time.
To return to normal mode press the 'Clock' button once, if no buttons are pressed for a period of approximately 60 seconds the controller will return to normal mode.
The time is always displayed regardless of whether the water controller is turned ON or OFF.
The clock may need resetting if power to the water heater unit is disrupted due to a power failure or if the power is switched off over a prolonged period.
ADJUSTING TEMPERATURE
Simply press the 'Temperature' or buttons until the required temperature is displayed on the digital monitor.
To operate the water heater, open any hot water tap. This will automatically light the burner, providing hot water. The ‘In Use’ indicator will illuminate on all water controllers.
Once the hot water is running, if the set temperature is either too hot or cold press the 'Temperature' or buttons until the desired temperature is reached.
Whilst hot water outlets are open the set temperature may be lowered. However it cannot then be raised above 43°C. In addition, transfer of 'priority' between controllers is not possible. These are safety features.
CHECK WATER TEMPERATURE BEFORE USE. A parent or carer should always check the temperature before a child is placed in contact with hot water, see page 5.
Rinnai Australia 11 Operation Manual
DELUXE BATHROOM WATER CONTROLLERS
NOTE
NOTE
OPERATING THE SHOWER SAVER / BATH FILL FUNCTION
The 'Shower Saver / Bath Fill' function allows a preset water volume and temperature to be selected and run automatically.
Initial Settings
When a deluxe bathroom controller is first turned on, the default shower / bath fill temperature is set to 40°C and the shower / bath volume is set to 100 litres. The shower / bath volume can be lowered to a minimum of 30 litres or raised to a maximum of 400 litres and the temperature adjusted as desired.
Setting Shower / Bath Temperature and Volume
With the system on, select a Deluxe Bathroom water controller and ensure that it currently has priority. If it does not have priority press the ‘Transfer’ button once and the ‘Transfer’ button will illuminate.
No voice prompts will be available if the ‘Voice OFF’ or ‘Sound OFF’ options are selected. With ‘Sound OFF’ there will also be no audible tones.
Press 'Shower Saver / Bath Fill' button once. The 'Shower Saver / Bath Fill' button will illuminate and a voice prompt and tone will sound.
To select the desired delivery temperature use the 'Temperature' or buttons.
The selected temperature will be displayed on the digital monitor and will remain as the default 'Shower Saver / Bath Fill' temperature until it is changed or if the mains power is turned off for an extended period.
To select the volume of water to be used in the shower / bath use the 'Water Volume' or buttons. The selected volume is displayed in large digits to the right and will remain as the default 'Water Volume' until it is changed or if the mains power is turned off for an extended period.
The selected volume is also repeated in the form of a remaining volume counter below the temperature and replaces the clock during 'Shower Saver / Bath Fill' operations.
When filling a bath for the first time, it is recommended that a low bath fill volume such as 60 litres or lower be used. During any subsequent bath fills the volume can then be adjusted to suit your known bath volume and or desired fill level.
Be careful not to overfill the bath, an average bath volume is 160 litres. It is recommended that when filling a bath for the first time you should:
• Remain by the bath during the filling process.
• Use a low bath fill volume such as 60 litres or less.
When Smartstart® (page 16) is in operation, the Shower Saver / Bath Fill function is unavailable while the water heater ‘In Use’ indicator is illuminated. Do not press the Preheat button whilst Shower Saver / Bath Fill is in operation as the programmed bath fill volume will not be met.
Using Shower Saver / Bath Fill
Press 'Shower Saver / Bath Fill' button once. The 'Shower Saver / Bath Fill' button will illuminate and a voice prompt and tone will sound. During 'Shower Saver / Bath Fill' operations the 'Bath' indicator will also be displayed in the Deluxe Kitchen water controller digital monitor (when fitted).
Rinnai Australia 12 Operation Manual
DELUXE BATHROOM WATER CONTROLLERS
HOTHOT
COLDCOLD
ON!ON!
HOTHOT
COLDCOLD
OFF!OFF!
CAUTION
NOTE
The voice prompt will say "The hot water system is ready. Open the hot water tap”. Open the hot water tap for the relevant shower or bath.
The ‘In Use’ indicator will illuminate on all Deluxe water controllers and the shower will run or the bath will start to fill.
To Stop Shower Saver / Bath Fill Operation
If you wish to stop the water flow whilst the Shower Saver / Bath Fill function is in operation, simply press the 'Shower Saver / Bath Fill' button.
The 'Shower Saver / Bath Fill' button will flash and the voice prompt will say "Hot water is not available, Turn off all hot water taps and push the 'Bath Fill' button". Follow the voice prompt instructions.
When Shower Saver / Bath Fill Operations Finishes
Once the Shower Saver / Bath Fill operation finishes the following events will occur:
1. The flow from the shower / bath hot water tap ceases.
2. The 'Shower Saver / Bath Fill' button will flash.
3. The Deluxe Kitchen water controller 'Bath' indicator will flash.
4. A tone will sound.
5. The voice prompt will say "Bath fill is complete. Turn off the bath hot water tap and push the Bath Fill button."
Follow the voice prompts instructions. Note that the water heater will not allow hot water to flow from any fixture until the 'Shower Saver / Bath Fill' button has been pressed.
6. The 'Shower Saver / Bath Fill' button light on the Deluxe Bathroom water controller and the 'Bath' indicator on the Deluxe Kitchen water controller monitor (when fitted) will go out.
CHECK WATER TEMPERATURE BEFORE USE. A parent or carer should always check the temperature before a child is placed in contact with hot water, see page 5.
NEVER LEAVE YOUNG CHILDREN UNATTENDED IN THE BATH. When using the 'Shower saver / Bath fill' function, ALWAYS close the hot water tap for the bath or shower after the flow has stopped.
Whilst hot water outlets are open the set temperature may be lowered. However it cannot then be raised above 43°C. In addition transfer of 'priority' between controllers is not possible. These are safety features.
USING MULTIPLE WATER CONTROLLERS
The water heater can be turned on and off at any water controller. If more than one water controller is fitted press the ‘Transfer’ button to transfer priority to the desired controller.
COMBINING UNIVERSAL AND DELUXE WATER CONTROLLERS
Universal and Deluxe water controllers can be combined and will function as described in other sections of the Water Heater Operation / Installation Manual. Refer to page 7 to confirm the maximum number and combination of controllers that can be fitted to your water heater model.
Rinnai Australia 13 Operation Manual
DELUXE KITCHEN WATER CONTROLLERS
Used toswitch the water heater on and off. This button is illuminated when the hot water heating system is on.
ON/OFF BUT TON
DIGITAL
MONITOR
Indicates that the water heater is in operation and delivering hot water.
WATER HEATER
'In Use' INDICATOR
SPEAKER
In 'Setup' mode these buttons are used to adjust the voice prompt volume and to set the clock.
UP AND DOWN BUTTONS
MODE BUTTON
WATER TEMPER ATURE
INDICATOR
SHOWER SAVER /
BATH FILL INDICATOR
This button is illuminated when the Smartstart® preheater (when fitted) is activated.
PREHEAT BUTTON
12 Hour AM / PM clock display.
CLOCK
TRANSFER BUTTON
Used to transfer control priority between the water controllers. The controller with priority has command of the hot water delivery temperature. This button is illuminated with this controller has priority.
Used to switch the controller between Normal, Voice or Clock modes.
Indicates that the Shower Saver /
Bath fill function is operating.
Indicates the selected hot water
temperature.
In the event of a fault, codes for
error messages will flash here.
Used to start and stop the Smartstart® preheater unit (when fitted), See Smartstart® Operation on page 16.
When in Normal mode these buttons are used to select the water temperature
NOTE
NOTE
ABOUT THE DELUXE KITCHEN WATER CONTROLLER (MC-100V)
TURNING ON THE WATER CONTROLLER
If the controller is switched off (No digits other than the clock digits displayed in the digital monitor) press the On/Off button once.
The On/Off and Transfer buttons illuminate to indicate that the hot water unit will be ready to supply hot water once a hot water tap is opened.
If more than one controller is fitted press the ‘Transfer’ button to transfer priority to the desired controller.
SETTING THE SOUND OPTIONS
To set the sound options press the 'Mode' button once to place the controller into ‘Voice’ mode.
Use the or buttons to select the desired audible setting as follows:
Voice High, Med, Low or Off, sets the voice prompt volume but does not affect the audible tones. Sound Off, mutes all voice prompts and audible tones.
To return to normal mode press the 'Mode' button once, if no buttons are pressed for a period of approximately 10 seconds the controller will return to normal mode.
Rinnai Australia 14 Operation Manual
Only one MC-100V may be fitted to your water heater. Refer to page 7 to confirm the maximum number and combination of controllers that can be fitted to your Water Heater model.
The MC-100V controller is not water resistant, avoid direct exposure to water or steam as these conditions may cause a malfunction.
Voice prompts only available when Deluxe Bathroom water controller(s) are installed.
DELUXE KITCHEN WATER CONTROLLERS
NOTE
HOTHOT
COLDCOLD
ON!ON!
NOTE
CAUTION
SETTING THE CLOCK
The clock is a 12 hour AM/PM style display. To set the time press the 'Mode' button twice. This places the controller into clock setting mode and in the digital monitor the word ‘Clock’ will be displayed and the clock digits will flash. If this is the first time the clock has been set the starting time will be AM 12:00.
Use the or buttons to select the desired time. Holding these buttons down continuously cycles the digits. When you get close to the time you wish to set, press the button intermittently to avoid going further than the desired time.
To return to normal mode press the 'Mode' button once. If no buttons are pressed for a period of approximately 10 seconds the controller will return to normal mode.
The time is always displayed regardless of whether the water controller is turned ON or OFF.
The clock may need resetting if power to the water heater unit is disrupted due to a power failure or if the power is switched off over a prolonged period.
ADJUSTING TEMPERATURE
Simply press the 'hot water temp' or buttons until the required temperature is displayed on the digital monitor.
To operate the water heater, open any hot water tap. This will automatically light the burner, providing hot water. The ‘In Use’ indicator will illuminate on the water controller.
Once the hot water is running, if the set temperature is either too hot or cold press the or buttons until the desired temperature is reached.
Whilst hot water outlets are open the set temperature may be lowered. However it cannot then be raised above 43°C. In addition transfer of 'priority' between controllers is not possible. These are safety features.
CHECK WATER TEMPERATURE BEFORE USE. A parent or carer should always check the temperature before a child is placed in contact with hot water, see page 5.
Rinnai Australia 15 Operation Manual
SMARTSTART® PRE-HEAT OPERATION
DIGITAL
MONITOR
Indicatesthat'Smartstart®' preheater is activated*
PREHE AT INDICATOR
2
5
8
1
2 3
ON/OFF
BUTTON
4
CONTROLLER ON
INDICATOR
5
TEMPER ATURE
BUTTONS
6
WATER HEATE R
'IN USE' INDIC ATOR
7
TRANSFER
BUTTON
8
Used to startand stop 'Smartstart ®' preheate r.
PREHEAT BUTTON
1
1
6
2
8
2
1
8
5
4
4
6
3 3 47 75 3 7
6
38563
127
NOTE
ABOUT THE SMARTSTART® PREHEAT SYSTEM
Preheat Function
The “Preheat” function works in conjunction with various Rinnai water heater models and the separately installed and optional Rinnai “Smartstart®” module.
When the “Preheat” function is activated and used in accordance with these instructions, water in the pipework connected between the water heater and the hot water outlets in your house is warmed before any outlets are opened. This results in water savings and added convenience.
The “Preheat” function is activated as follows:
1. Ensure that the hot water unit is on (temperature digits are displayed in the digital monitor ).
If more than one controller is fitted press the ‘Transfer’ button to pass on priority to your desired controller, the ‘Controller On’ indicator will illuminate to confirm that priority has been assigned to this controller and that the hot water unit is ready to deliver hot water.
2. Select the desired temperature using the 'Temperature' buttons until the required
temperature is displayed in the digital monitor .
3. Press the ‘Preheat’ button once. The ‘Preheat’ indicator and the ‘In Use’ indicators
will illuminate, signifying that the preheat system has been activated.
4. Wait approximately two minutes before opening an outlet. This will allow the water in the
pipework to be warmed.
The waiting time may be longer or shorter than two minutes depending on your particular installation configuration.
The “Preheat” function is cancelled 5 minutes after activation and the ‘Preheat’ indicator will go out. This is to conserve energy. To reactivate, simply repeat steps 2-4 above.
* If the ‘Preheat’ button is pressed and the ‘Smartstart®’ preheat unit is not installed, the ‘Preheat’ indicator will still light but there will be no “Preheat” function. The ‘Preheat’ indicator will go out after a short time and will not affect the other functions of the water controller or water heater.
After using the Shower Saver / Bath Fill function wait 30 seconds before activating the “Preheat” function. Attempting to use the “Preheat” function earlier will result in voice prompts being repeated until the system is reset. The system can be reset by pressing the ‘On /Off' button twice.
Other Controller Functions
Controller functions such as temperature control and transfer of priority between multiple controllers is not affected by the operation of the preheat. Such functions are described in the applicable sections of this manual.
Rinnai Australia 16 Operation Manual
TROUBLESHOOTING
NOTE
Your Rinnai Continuous Flow water heaters has a self diagnostic capability. If a fault occurs, an
Error Code will flash on the digital monitor or status monitor* if you have water controllers. This assists with diagnosing the fault, and may enable you to overcome a problem without a service call. Please quote the code displayed when enquiring about service. *All models in the range covered by this manual have a “Status Monitor”, except B16, B20 & B26.
ERROR FAULT REMEDY
-
03
10 Air intake or flue blocked. Service Call.
11 No ignition / No gas supply.
12 Flame Failure / Low gas flow.
14 Remaining Flame Safety Device. Service Call.
16 Over Temperature Warning. Service Call.
25 Condensate Pipe Blockage Check for blockage on condensate drain path.
32 Outgoing Water Temperature Sensor Faulty. Service Call.
33 Heat Exchanger Outlet Sensor Faulty. Service Call.
34 Combustion Air Temperature Sensor Faulty. Service Call.
52 Gas Modulating Valve Faulty. Service Call.
61 Combustion Fan Failure. Service Call.
65
Noticeable reduction in water flow. Inlet water filter needs to be cleaned. Service call.
Power interruption during Bath fill
(Water will not flow on power reinstatement).
Water Flow Control Faulty
(Does not stop flow properly).
Turn off all hot water taps. Press On/Off twice.
Check gas is turned on at water heater and gas meter
or cylinder.
Check gas is turned on at water heater
and gas meter or cylinder.
Check there are no obstructions to the flue outlet.
Service Call.
71 Micro-processor Failure. Service Call.
72 Micro-processor Failure. Service Call.
LC Scale build-up inside the heat exchanger. Service Call.
In all cases, you may be able to clear the Error Code simply by turning the hot water tap OFF, then ON again. If this does not clear the Error Code, try pushing the On/Off button OFF, then ON again. If the Error Code still remains, contact Rinnai for advice.
Troubleshooting Without Water Controllers
If you have no water controllers and experience the following symptoms, carry out these suggestions. If the symptom continues, contact Rinnai for advice.
FAULT REMEDY
The unit does not attempt to start at all.
The unit starts then shuts down immediately.
The unit starts then the water goes cold.
Check the power is on at the unit.
Check the isolation valves at the unit are open.
Check the power is still on. Check the gas isolation valves at the unit and the gas meter are fully open.
Open your hot water tap fully.
Check the power is still on.
Open your hot water tap further.
Faults caused by insufficient gas supply, insufficient water supply, gas quality, water quality, installation errors or operation errors are not covered by the Rinnai warranty. Refer to separate warranty booklet for details.
Rinnai Australia 17 Operation Manual
INTENTIONALLY BLANK PAGE
Rinnai Australia 18 Operation Manual
INTENTIONALLY BLANK PAGE
Rinnai Australia 19 Operation Manual
INSTALLATION MANUAL
GENERAL INSTALLATION INSTRUCTIONS ..........................................................21
REGULATIONS ......................................................................................................................................... 21
APPLICABLE MODELS ............................................................................................................................ 21
APPLIANCE LOCATION ........................................................................................................................... 21
PIPE SIZING ............................................................................................................................................. 22
WATER SUPPLY ...................................................................................................................................... 22
HOT WATER DELIVERY TEMPERATURE .............................................................................................. 22
WATER HEATER AND CONTROLLER INSTALLATION CONFIGURATIONS ........................................ 22
MOUNTING THE APPLIANCE ................................................................................................................. 23
SERVICE CONNECTION POINTS ........................................................................................................... 23
HORIZONTAL FLUE TERMINAL CLEARANCES ................................................................................... 24
HORIZONTAL OBSTRUCTIONS .............................................................................................................. 25
MULTIPLE INSTALLATIONS OF EXTERNAL MODELS .......................................................................... 25
APPLIANCE AND WATER CONTROLLER DIMENSIONS ...................................................................... 26
CO-AXIAL FLUEING FOR INTERNAL MODELS ..................................................................................... 27
CONDENSATE DRAIN (REU-KM’ MODELS ONLY)................................................28
IMPORTANT CONSIDERATIONS FOR THE CONDENSATE DRAIN PIPE ............................................ 28
LENGTH AND CHANGES OF DIRECTION .............................................................................................. 28
INSTALLATION ......................................................................................................................................... 28
INTERCONNECTION OF CONDENSATE DRAIN LINES ........................................................................ 29
COMMON STACK DISCHARGE .............................................................................................................. 29
TUNDISH DRAIN LINES ........................................................................................................................... 29
AREAS SUBJECT TO FREEZING ............................................................................................................ 29
WATER CONTROLLER INSTALLATION.................................................................30
RINNAI WATER CONTROLLERS ............................................................................................................ 30
POSITIONING OF WATER CONTROLLERS ........................................................................................... 30
WATER CONTROLLER CABLES ............................................................................................................. 30
FITTING THE ‘UNIVERSAL’ WATER CONTROL (MC-91Q) .................................................................... 30
OPTIONAL PROGRAMMING FOR THE ‘UNIVERSAL’ WATER CONTROLLER (MC-91Q) ................... 31
FITTING THE ‘DELUXE KITCHEN’ WATER CONTROLLER (MC-100V) ................................................ 32
FITTING THE ‘DELUXE BATHROOM’ WATER CONTROLLER (BC-100V) ............................................ 32
CONNECTING COMMUNICATION CABLES TO THE WATER HEATER ............................................... 33
COMMISSIONING .....................................................................................................34
TESTING ................................................................................................................................................... 34
DELIVERY TEMPERATURE .................................................................................................................... 34
GAS PRESSURE SETTING ..................................................................................................................... 35
COMMISSIONING CHECK LIST .............................................................................................................. 35
ACCESSORIES ........................................................................................................36
PRODUCT RECORDS .............................................................................................36
CONTACT INFORMATION ......................................................................................37
Rinnai Australia 20 Installation Manual
GENERAL INSTALLATION INSTRUCTIONS
NOTE
NOTE
REGULATIONS
This appliance must be installed in accordance with:
Current AS/NZS 3000, AS/NZS 3500 and AS/NZS 5601
Rinnai Installation Instructions
Local regulations and municipal building codes including local OH&S requirements
Installation, Service and Removal MUST BE by an Authorised Person only.
APPLICABLE MODELS
These Installation Instructions apply only to the following Rinnai Continuous Flow Water heater models are listed on the cover page of this manual.
APPLIANCE LOCATION
(External Models)
This appliance is designed for ‘Outdoor’ Installation only. As such, it must be located in an above ground open air situation with natural ventilation, without stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural convection.
This appliance must be mounted on a vertical structure with the water and gas connections on the underside pointing downwards. For appliances installed on elevated structures or under floors specific requirements apply. Refer to AS/NZS 5601 Section 6 for details.
This appliance must not be used as a domestic spa or swimming pool heater.
Location of the appliance flue terminal must be in accordance with Section 6 and Figure 6.2 of AS/NZS 5601. Figure 6.2 is reproduced in the ‘Horizontal Flue Terminal Clearances’ section of these instructions.
AS/NZS 5601 was current at the time of printing but may have been superseded. It is the installer’s responsibility to ensure current requirements are met.
(Internal Models)
This appliance is designed for ‘Indoor’ installation only. It may be installed ‘Outdoors’ in an enclosure if the requirements of AS/NZS 5601 Section 6 are satisfied. An enclosure is defined as a compartment, enclosed area or partitioned off space primarily used for the installing of the appliance. If installed in an enclosure, either Internally or Externally, the location should be ventilated to allow gas to dissipate.
If the water heater is installed in a concealed location, provisions must be made for the safe disposal of any leaking water from the water heater to a visible location.
This appliance must be mounted on a vertical structure with the water and gas connections on the underside pointing downwards. For appliances installed in roof spaces or elevated structures specific requirements apply. Refer to AS/NZS 5601 Section 6 for details.
This appliance must not be used as a domestic spa or swimming pool heater.
Rinnai internal models described in this manual must use the Co-Axial Rinnai FFU flue components. The use of non Rinnai FFU flue components may result in a dangerous situation and violates regulations. The maximum FFU flue length is 9 metres with a maximum of three 90 degree bends. Horizontal (wall) or vertical (roof) terminals are available. For detailed information refer to “CO-AXIAL FLUEING FOR INTERNAL MODELS” on page 27.
This appliance must be located so that the flue terminal exits the building at a suitable point.
If a horizontal (wall) terminal FFWALLTERM is used, the location must be in accordance with Section 6 and Figure 6.2 of AS/NZS 5601. Figure 6.2 is reproduced under ‘HORIZONTAL FLUE TERMINAL CLEARANCES’ on page 24 of this manual.
If a vertical (roof) terminal FFROOFCOWL is used, the location must be in accordance with Section 6 of AS/NZS 5601 and the “CO-AXIAL FLUEING FOR INTERNAL MODELS” on page 27.
AS/NZS 5601 was current at the time of printing but may have been superseded. It is the installer’s responsibility to ensure current requirements are met.
Rinnai Australia 21 Installation Manual
GENERAL INSTALLATION INSTRUCTIONS
(All Models)
This appliance must be placed as close as practicable to the most frequently used hot water outlet or outlets to minimise the delay time for hot water delivery. For installations where the distance between the water heater and the outlets is considerable, a flow and return system or the Rinnai Smartstart® system can be used which minimise the waiting time for hot water delivery.
Alternatively, multiple appliances can be strategically placed to serve outlets with minimal delay time. Contact Rinnai for further information.
An AC240V, 10 Amp, earthed power point must be provided adjacent to the appliance. For outdoor installations this power point must be weather proof. It must be clear of the gas and water connections to the appliance and also the flue exhaust and water pressure relief valve. The power cord of the appliance is 1.5 Metres long.
All appliances must be installed to ensure access can be gained without hazard or undue difficulty for inspection, repair, renewal or operational purposes. Sufficient clearances shall allow access to, and removal of, all serviceable components. Appliances should not be mounted higher than 2.5 metres above the ground or floor level unless the customer can arrange permanent and safe access or can provide another means of access, for example, by means of scissor or boom lifts acceptable to local authorities.
PIPE SIZING
See Table 1 page 23 for appliance gas consumption. If the gas pipe sizing is insufficient the customer will not get the full performance benefit. Gas pipe sizing must consider the gas input to this appliance as well as all the other gas appliances in the premises. The gas meter and regulator must be specified for this gas rate. An approved sizing chart such as the one in AS/NZS 5601 should be used.
Water pipe sizing and layout should be performed in accordance with AS/NZS 3500. All hot water pipe-work should be insulated to optimise performance and energy efficiency.
WATER SUPPLY
See Table 1, page 23 for applicable water pressures. Approved pressure limiting valves may be required if the ‘Maximum’ rated water supply pressures in Table 1 are exceeded. To achieve the rated flow, the ‘Minimum’ water supply pressures in Table 1 must be supplied. The water heaters will operate at lower pressures but will not achieve the rated flow. Contact Rinnai for ‘gravity fed’ or ‘low pressure’ installations.
Water chemistry and impurity limits are detailed under ‘Warranty Conditions’. Most metropolitan water supplies fall within the requirements. If you are unsure about your local water quality, contact your water authority. If sludge or foreign matter is present in the water supply, a suitable filter or strainer should be incorporated in the water supply to the water heater.
HOT WATER DELIVERY TEMPERATURE
Local regulations and or the requirements of AS/NZS 3500 must be considered regarding the temperature limitations of hot water supplied to areas used primarily for personal hygiene. The temperature of water to these areas may be limited to 50°C or less. To ensure these regulations and or requirements are met the system MUST be installed in accordance with the 'Water Heater and Controller Installation Configurations' Section of these instructions.
WATER HEATER AND CONTROLLER INSTALLATION CONFIGURATIONS
If the appliance is marked to state that it delivers water not exceeding 50°C, local regulations may permit it's installation without a Temperature Limiting Device. Installations without a Temperature Limiting Device are shown in Diagram 1 (page 23). If you are unsure about your local regulations contact your regulating authority or Rinnai.
If the appliance is NOT marked to state that it delivers water not exceeding 50°C, or your local regulations require installation with a Temperature Limiting Device then install the appliance in accordance with Diagram 2 (page 23).
Ensure that suitable fixing screws or bolts are used to secure the units to the wall, in accordance with AS/NZS 5601 section 6. Wooden plugs shall not be used.
The top bracket has a keyhole slot so that the appliance can be positioned by hanging it on one screw, then the other screws can be secured.
Rinnai Australia 22 Installation Manual
GENERAL INSTALLATION INSTRUCTIONS
IMPORTANT
50º C
KITCHEN
Water controller
(optional)
Water controller
(optional)
Water controller
(optional)
Water controller
(optional)
LAUNDRY
BATHROOM
ENSUITE
H O T
C O L D
G A S
KITCHEN
Water controller
(optional)
Water controller
(optional)
LAUNDRY BATHROOM
Water controller
(optional)
Water controller
(optional)
ENSUITE
TLD
H
O
T
C O
L
D
G A S
Diagram 1 - 50°C Appliance
Diagram 2 - Not a 50°C Appliance
Note: TLD = Temperature Limiting Device
Minimum length of pipe from hot outlet to nearest hot water tap 2 metres.
MOUNTING THE APPLIANCE
See Table 1, page 23 for individual appliance weights. The wall or structure on which the units are to be mounted must be capable of supporting these weights and the associated pipe-work.
The top bracket has a keyhole slot so that the appliance can be positioned by hanging it on one screw, then the other screws can be secured.
The appliance can be mounted directly against the wall or structure. There is no need to use, non combustible sheeting or leave an air gap between the appliance back panel and the wall or structure for the purposes of meeting the temperature hazard requirements of AS/NZS 5601.
If the appliance is to deliver water primarily for the purposes of personal hygiene in an early childhood centre, primary or secondary school, nursing home or a similar facility for the care of young, aged, sick or disabled persons as defined in AS/NZ 3500 a Temperature Limiting Device (TLD), such as a Tempering Valve may be required even if the appliance is set to 50º C or less.
For these types of applications contact Rinnai.
SERVICE CONNECTION POINTS
See Table 1 for individual appliance connection / fitting dimensions. Note that these dimensions are NOT an indication of the pipe sizes required.
An Approved full flow isolation valve and disconnection union MUST be fitted to the cold water inlet. A non return valve is not required unless required by local regulations.
Isolation Valves must not be fitted directly to the appliance.
If may be necessary to fit a temperature limiting device for delivery to areas used primarily for the purposes of personal hygiene. Refer to the ‘Water Heater and Controllers Installation Configurations’ Section of this document.
Purge gas and cold water supply lines to remove air and swarf before final connection of the appliance. Swarf in either the gas or water supplies may cause damage.
Model:
REU-VRM3237WC 250 180 1000 29 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) ­REU-VRM3237WG 250 180 1000 29 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) ­REU-VRM2626WG 199 200 1000 16 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) -
REU-VRM2632WC 199 140 1000 21 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) ­REU-VRM2632FFUG 195 140 1000 21 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) ­REU-VRM2632FFUC 195 140 1000 21 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) -
REU-KM3237WDC 211 250 1000 32 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) R ½ (15mm) REU-KM3237FFUDC 211 250 1000 32 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) R ½ (15mm)
REU-KM3237WD 211 250 1000 32 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) R ½ (15mm) REU-KM2635WD 172 250 1000 29 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) R ½ (15mm) REU-VR2626WB 199 200 1000 16 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) -
REU-VRM2024WG 160 160 1000 15 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) -
REU-VR2024WB 160 160 1000 15 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) -
REU-VRM1620WG 125 120 1000 15 R ½ (15mm) R ½ (15mm) R ¾ (20mm) -
REU-VR1620WB 125 120 1000 15 R ½ (15mm) R ½ (15mm) R ¾ (20mm) -
Rinnai Australia 23 Installation Manual
Gas
Consumption
MJ/h
Water Supply kPa
Min. Max. Hot Cold Gas Condensate
Weight
kg
Table 1.
Fittings
GENERAL INSTALLATION INSTRUCTIONS
Flue terminal Fan assisted flue appliance only Gas meter Electricity meter or fuse box Mechanical air inlet
Min. Clearances
(mm)
Fan-Assisted
Appliances up to 50 MJ/h input
200
Appliances over 50 MJ/h input
300
b From the ground, above a balcony or other surface * 300
c Front a return wall or external corner * 300
d
From a gas meter (M) (see 5.11.5.9 for vent terminal location of regulator ) (see Table 6.6 for New Zealand requirements)
1000
e
From an electricity meter or fuse box (P) †
500
f From a drain pipe or soil pipe 75
g
Horizontally from any building structure* = or obstruction facing a terminal
500
h
From any other flue terminal , cowl, or combustion air intake †
300
Appliances up to 150 MJ/h input *
300
Appliances over 150 MJ/h input up to 200 MJ/h input *
300
Appliances over 200 MJ/h input up to 250 MJ/h input *
500
Appliances over 250 MJ/h input *
1500
• All fan-assisted flue appliances , in the direction of discharge
1500
k From a mechanical air inlet, including a spa blower 1000
• Space heaters up to 50 MJ/hr input 150
• Other appliances up to 50 MJ/hr input
500
Appliances over 50 MJ/h input and up to 150 MJ/h input
1000
Appliances over 150 MJ/h input
1500
1
Where dimensions c, j or k cannot be achieved an equivalent horizontal distance measured diagonally from the nearest discharge point of the terminal to the opening may be deemed by the Technical Regulator to comply.
2
See Clause 6.9.4 for restrictions on a flue terminal under a covered area.
3
See Figure J3 for clearances required from a flue terminal to an LP Gas cylinder. A flue terminal is considered to be a source of ignition.
4
For appliances not addressed above acceptance should be obtained from the Technical Regulator.
Ref. Item
a
Below eaves, balconies and other projections:
FIGURE 6.2 (in-part) MINIMUM CLEARANCES REQUIRED FOR FAN-ASSISTED FLUE TERMINALS, ROOM­SEALED APPLIANCE TERMINALS AND OPENINGS OF OUTDOOR APPLIANCES
* - unless appliance is certified for closer installation
n
j
Horizontally from an openable window, door, non-mechanical air inlet, or any other opening into a building with the exception of sub-floor ventilation:
Vertically below an openable window, non-mechanical air inlet, or any other opening into a building with the exception of sub-floor ventilation:
NOTES:
† - Prohibited area below electricity meter or fuse box extends to ground level.
HORIZONTAL FLUE TERMINAL CLEARANCES
Rinnai Australia 24 Installation Manual
Extract from AS/NZS 5601
GENERAL INSTALLATION INSTRUCTIONS
500mm
HORIZONTAL OBSTRUCTIONS
AS/NZS 5601 ‘Gas Installations’ stipulates a minimum horizontal clearance of 500 mm between a building structure and obstruction facing the terminal. For Rinnai external continuous flow water heaters such a building structure must ‘obstruct’ the full front cover height of the appliance, or extend vertically above and below the front cover. There must be no partial obstructions to the front cover of the appliance or any other parts of the appliance casing. This will avoid the appliance failing to operate under windy conditions.
MULTIPLE INSTALLATIONS OF EXTERNAL MODELS
Dimension ‘h’ above does not apply when multiple Rinnai external water heaters of the same model are installed on the same vertical face with flue terminals at the same height. Under these conditions appliances can abut each other as shown. The total gas consumption of all appliances applies when determining other clearances.
Rinnai Australia 25 Installation Manual
GENERAL INSTALLATION INSTRUCTIONS
Condensate Connection Length (from base) - - -22 ---
Dim' Description
REU-VRM3237WG
REU-VRM3237WC
REU-VRM2626WG
REU-VRM2632FFUG
REU-VRM2632FFUC
A Width 470 350 350 B Depth
244 194
235~375
C Height - Unit 600 530 600 D Height - Including Brackets 644 571 641 E Hot Water outlet (from wall) 115 87 91~131 F Hot Water outlet (from centre) 61 105 110
G Cold Water inlet (from wall) 99 68 70~ 1 10
H Cold Water inlet (from centre) 52 10 27*
K Condensate outlet (from wall) - - - L Condensate outlet (from centre) - - -
Gas Connection
Length (from base)
41 40 41
Cold Connection Length (from base) 51 50 51 Hot Connection Length (from base)
42 42 42
Gas: Fitting Diameter 20 20 20
Condensate: Fitting Diameter - - -
M
N
B
O
D
C
M
470
257~307
654
722
100~150
100
65~115
28
195
40
50
41
20
15
REU-VR2626WB
350
194
530
571
87
105
68
10
-
-
40
50
42
20
-
REU-VRM1620WG
REU-VR1620WB
REU-VRM2024WG
REU-VR2024WB
350
194
530
571
87
105
68
10
-
-
40
50
39
20
-
350
194
530
571
87
105
68
10
-
-
I
Gas Connection (from wall)
61 77 99 ~139
J Gas Connection (from centre) 110 83 89
89~139
103
77
83
77
83
77
83
40
50
39
20
-
Cold: Fitting Diameter
20 20 20
Hot: Fitting Diameter 20 20 20
Flue Spigot Centreline (from wall, FFU only) - - 95 ~ 135 ------
-
REU-VRM2632WC
350
251
600
636
96
110
75
27*
-
-
41
51
42
20
-
104
89
20
20
20
20
20
20
22
REU-KM3237WD
REU-KM3237WDC
470
283
670
722
115
100
80
28
138
195
40
50
41
20
15
104
103
20
20
15
15
20
20
A
E
F
J
L
H
I
G
K
* Please note that this measurement is to the left of the centre line.
P
QS
R
Dim' Description
MC-100V
P Width 128 Q Height 120 R Depth 20
S
Distance between mounting hole centres
83
BC-100V 202 104
22
181
MC-91
90
120
20
83
N
FITTING DIAMETER
22
REU-KM2635WD
470
283
670
722
115
100
75
13
138
195
40
50
41
20
15
104
103
20
20
O
REU-KM3237FFUDC
123
149~199
APPLIANCE AND WATER CONTROLLER DIMENSIONS
Rinnai Australia 26 Installation Manual
GENERAL INSTALLATION INSTRUCTIONS
OFFON
SW1
1 2345678
FFU (Internal) Models Only
Short Flue: Total flue
length less than 1.5 metres
OFFON
SW2
123456
OFFON
SW1
1 2345678
FFU (Internal) Models Only
Extended Flue: Total flue
length 1.5 metres or greater
OFFON
SW2
123456
Flue Length Dip Switch Settings
Dipswitches
SW1
Dipswitches
SW2
1
2
3
4
CO-AXIAL FLUEING FOR INTERNAL MODELS
Rinnai internal models described in this manual must use the Co-Axial Rinnai FFU flue components. The use of non Rinnai FFU flue components may result in a dangerous situation and violates regulations.
The FFU flue system must be installed in accordance with the ‘FFU Flue Installation Manual’ which is provided with the FFU flue terminal components FFWALLTERM or FFROOFCOWL.
Installations can consist of both horizontal and vertical runs to a maximum length of 9 metres and with a maximum of three 90° bends.
If flue length exceeds 1.5m, dipswitch 1 of SW1 is to be switched to the 'OFF' position.
This increases the combustion speed to overcome the additional friction loses.
Basic methods of installation
There are four basic flue installation methods available. These are:
(1.) Direct Horizontal
(2.) Extended Horizontal
(3.) Vertical
(4.) Combination Vertical /
Horizontal
Multiple Terminal Installations
The terminal clearances stated in AS/NZS 5601 do not apply to the Rinnai internal continuous flow water heaters when they are installed side by side.
AGA certification allows for a horizontal separation of 160 mm for roof terminals and 270 mm for wall terminals.
Rinnai Australia 27 Installation Manual
CONDENSATE DRAIN (REU-KM’ MODELS ONLY)
NOTE
D
B
A
C
E
A
Remove cap from condensate drain outlet
Condensate drain applies to both internal and external models, the external model is shown in this illustration.
NOTE
A
BCB
D
E
The INFINITY & HDC REU-KM’ range of water heaters generate condensate continuously at a rate of up to 5 litres per hour as a by-product of highly efficient gas burner system. This condensate must be drained via a pipe to a suitable point of discharge. Because the condensate is a by-product of gas combustion it is mildly acidic. For this reason copper tube and fittings MUST NOT be used as it will corrode. Instead, Rinnai recommend plastic pipes and fittings such as Unplasticised Polyvinyl Chloride (UPVC) or Polyethylene (PE) which is commonly used for irrigation piping.
IMPORTANT CONSIDERATIONS FOR THE CONDENSATE DRAIN PIPE
The content of AS/NZS 3500 ‘Temperature / Pressure Relief and Expansion Control Valve Drain Lines’ has been used as a guide in preparing these considerations.
Water heater drain outlet connection, R½” (15 mm) BSP male. Condensate drain outlet connection, 1/2” (15mm) BSP male nylon (Note: the black plastic shipping cap MUST BE removed from the condensate drain outlet prior to water heater operation).
PE R½” BSP (15 mm) female to barbed irrigation system connector (13 – 19mm) or equivalent plastic fitting. Drain pipe and fittings to match item .
Continuous fall (of at least 2°) from water heater to discharge point. Lengths and bends in accordance with ‘LENGTH AND CHANGES OF DIRECTION’ below.
Suitable points of discharge are deemed to be drains, sewers or pits. DO NOT discharge onto electrical connections, earth stakes, copper pipes, concrete paths or into a pond.
LENGTH AND CHANGES OF DIRECTION
Maximum length and changes of direction greater than 45° should be as follows:
Max changes of direction >45° 3 4 5 6
Lengths and changes of direction
Max length (Metres) 9 8 7 6
INSTALLATION
(a) The drain line MUST NOT discharge onto electrical connections, earth stakes, copper pipes,
concrete paths or into a pond.
(b) The point of discharge from each drain line shall be located so that the release of condensate
does not cause a nuisance, is readily discernible and incurs no risk of damage to the building.
In view of (a) and (b), suitable points of discharge are deemed to be drains, sewers or pits.
(c) There shall be no tap, valve or other restrictions in any line.
(d) Each line shall fall continuously from the valve to the approved point of discharge.
(e) Drain lines shall not discharge into a storage water heater safe tray.
(f) The end of the condensate drain line shall be:
(i) not lower than 200 mm or higher than 300 mm above an unpaved surface; or
(ii) not lower than 75 mm or higher than 300 mm above a gravel pit not less than 100 mm in diameter in a paved surface.
(g) Where discharging over a tundish or gully trap, drain lines shall have an air gap of a size at least
twice the diameter of the drain line.
Rinnai Australia 28 Installation Manual
CONDENSATE DRAIN (REU-KM’ MODELS ONLY)
INTERCONNECTION OF CONDENSATE DRAIN LINES
Condensate drain lines from multiple water heaters may be joined together provided they conform with the ‘INSTALLATION’ requirements on page 28.
COMMON STACK DISCHARGE
Where individual water heaters are installed in a multistorey building, the condensate drain lines may discharge into a common stack, subject to the following:
(a) The discharge from the common stack is to a tundish, having a discharge line, that is not less
than the size of the common stack, directly connected to a fixture trap, and installed in connection with any adjacent soil or waste stack.
(b) The discharge point of the common stack is such that any discharge is readily visible and not
cause any nuisance.
(c) The common stack is vented by extending the pipe upwards, above the roof level.
TUNDISH DRAIN LINES
The drain line from any tundish shall be not less than DN 20 or less than one size larger than that of the largest drain line discharging into the tundish. Tundish drain lines shall comply with the
‘INSTALLATION’ requirements on page 28.
AREAS SUBJECT TO FREEZING
In areas where water pipes are prone to freezing, the drain pipe from any valve shall be insulated and not exceed 300 mm in length. It shall discharge into a tundish through an air gap of not less than 75 mm and not more than 150 mm measured from the outlet of the drain pipe to the rim of the tundish.
Rinnai Australia 29 Installation Manual
WATER CONTROLLER INSTALLATION
NOTE
NOTE
NOTE
RINNAI WATER CONTROLLERS
Water controllers are available as an optional extra. Universal and Deluxe water controllers can be used together and will function as described in the Operation Section of this manual. Please refer to page 7 to confirm the maximum number and combination of water controllers that can be fitted.
Other manufacturers water controllers are NOT compatible with Rinnai water heaters. Water controllers MUST NOT be used with any Solar Boost water heater. Rinnai water controllers brought in from other countries are not compatible with Rinnai appliances sold in Australia.
POSITIONING OF WATER CONTROLLERS
Water controllers must be installed in shaded and clean locations. They should be fitted out of reach of children (suggested height from floor to be at least 1500 mm). BC-100V remote controllers are water resistant, however, durability is improved when positioned outside the shower recess. All deluxe remote controllers must be installed at least 400 mm above the highest part of a sink, basin or bath.
• Do not install remote controllers near a heat source, such as a cook top, stove or oven. Heat, steam, smoke and hot oil may cause damage.
• Do not install remote controllers in direct sunlight.
• The MC-100V remote controller MUST NOT be installed in a bathroom.
• Do not install remote controllers outdoors unless protection from dust ingress and sunlight are provided.
• Do not install remote controllers against a metal wall unless the wall is earthed in accordance with AS/NZS3000.
• Water controllers MUST NOT be installed where chemicals such as benzine, alcohol, turpentine or other similar chemicals are in use.
POSITIONING CONSIDERATIONS FOR THE MC-100V WATER CONTROLLER.
The MC-100V uses a Liquid Crystal Display (LCD) for the digital monitor. Light reflections can make the LCD difficult to see at direct eye level.
For best results when Installing the MC-100V mount the remote controller lower than your eye-level to avoid these light reflections.
WATER CONTROLLER CABLES
Water controllers operate at extra low voltage (12 Volts DC) which is supplied from the water heater. Each Water controller comes supplied with 15 m of electrical cable. The appliance end of the cables are fitted with spade terminals. Extension cabling is available from Rinnai.
Alternatively two core sheathed (double insulated) flex with minimum cross­sectional area of 0.5 mm² may be used. Maximum individual cable runs should not exceed 50 m.
FITTING THE ‘UNIVERSAL’ WATER CONTROL (MC-91Q)
1. Determine the most suitable position for the water controller.
2. Mark and drill 3 holes, locating the cable access as shown in (Fig. 1).
3. When running cable through the access hole ensure the connector end of the cable is located nearest to the controller (Fig. 2).
4. Carefully remove face plate from the water controller, using a screw driver (Fig. 3).
5. Connect the cable to the water controller. Feed any excess cable lengths into the wall cavity to avoid the pinching of cables between the wall and the controller.
6. Fix the water controller to the wall using the appropriate fixings as shown in (Fig. 4).
Rinnai Australia 30 Installation Manual
WATER CONTROLLER INSTALLATION
Connector
Controller Cable
Face Plate
Face Plate
Screw
Film
QUESTION
QUESTION
NOTE
7. Remove protective film from the water controller face as shown in (Fig. 4) and replace face plate.
41.5
83
120
Securing
Screw
Outline of Water Control
90
Fig. 1
Ø20 Cable Access
Fig. 2 Fig. 3 Fig. 4
OPTIONAL PROGRAMMING FOR THE ‘UNIVERSAL’ WATER CONTROLLER (MC-91Q)
Are there four water controllers connected?
IF NO: (You have three water controllers or fewer), go to Question 2.
IF YES: You will need to activate the fourth water controller as follows:
STEP 1: For the water controller in the KITCHEN ONLY, press and hold
the ‘Transfer’ and ‘On/Off’ buttons simultaneously (see Fig. 5) until a ‘beep’ is heard (approximately 5 seconds).
STEP 2: Check that the display on ALL FOUR water controllers is lit and
displaying a temperature when ‘switched on’. If any ONE of the controller displays two dashes (see Fig. 6) repeat STEP 1.
This completes the activation procedure for the fourth controller, you may ignore Question 2.
Fig. 5
Fig. 6
Is the water heater marked to state it delivers water not exceeding 50°C?
IF YES: No further action required.
IF NO: You will need to program the kitchen controller to enable
selection of temperatures higher than 50°C.
STEP 1: For the controller in the KITCHEN ONLY, press and hold the
‘Transfer’ and ‘On/Off’ buttons simultaneously (Fig. 7) until a ‘beep’ is heard (approximately 5 seconds).
Fig. 7
STEP 2: When the controller fitted in the KITCHEN is switched On, it
should be possible to select temperatures higher than 50°C. If not, repeat STEP 1.
If the water controller in the kitchen is replaced, repeat STEP 1 above for the replacement controller.
If the water controller in the kitchen is swapped with another controller (for example, the controller fitted in a bathroom), repeat STEP 1 for the controller moved from the kitchen to the bathroom. Then perform STEP 1 for the controller moved from bathroom to the kitchen.
Rinnai Australia 31 Installation Manual
WATER CONTROLLER INSTALLATION
181
202
Outline of Water Controller
104
Securing Screw
Ø20 Cable Access
Connector
Controller Cable
Backing Seal
Remove film
to expose
self-adhesive
FITTING THE ‘DELUXE KITCHEN’ WATER CONTROLLER (MC-100V)
1. Determine the most suitable position for the water controller (see notes page 30).
2. Use the wall mounting bracket as a template to mark and drill 3 holes, locating the cable access as shown in (Fig. 1).
3. Fix the mounting bracket to the wall using the appropriate fixings.
4. Run the cable through the hole in the wall.
128
5. Carefully remove face plate from the water controller, using a screw driver (Fig. 2).
Screw Securing Points
Outline of Water Controller
Fig.1
6. Connect the cable to the water controller as shown in (Fig 3). At this point cables from other controllers (if fitted) may also be connected to the screw terminals of the Kitchen water controller (Fig. 4) eliminating the need for multiple cable runs directly to the water heater. Water controllers are not polarity sensitive. Feed any excess cable lengths into the wall cavity to avoid the pinching of cables between the wall and the controller.
7. Fasten the controller to the wall mounting bracket as shown in (Fig. 5). Avoid the over-tightening of fixings as this may cause damage. Once secured replace the face plate.
Fig. 2 Fig. 3
Fig. 4 Fig. 5
FITTING THE ‘DELUXE BATHROOM’ WATER CONTROLLER (BC-100V)
1. Determine the most suitable position for the water controller (see notes page 30).
120
Ø20 Cable Access
2. Mark and drill 3 holes, locating the cable access as shown in (Fig. 1).
3. When running a cable through the access hole ensure the connector end of the cable is located nearest to the controller (Fig. 2).
4. Affix the double sided self-adhesive seal to the back of the water controller (Fig. 3).
5. Carefully remove the face plate from the water controller, do this by
Fig. 1
placing your thumbs on the front of the digital display and while hooking your fingers behind top of plate and gently push as shown in (Fig. 4), DO NOT use a screwdriver as this may damage the controller.
6. Connect the cable to the water controller. Feed any excess cable lengths into the wall cavity to avoid the pinching of cables between
Fig. 2
the wall and the controller.
7. Fix the controller to the wall using the appropriate fixings as shown in (Fig. 5), avoid over­tightening of fixings as this may cause damage. Once secured replace the face plate.
Fig. 3 Fig. 4 Fig. 5
Rinnai Australia 32 Installation Manual
WATER CONTROLLER INSTALLATION
CAUTION
A
B
C
D
E
A
A
B
A
C
E
D
B
'Ezi connect' cable connector for water heater models:
INFINITY 26, 20, 16, B26, B20 & B16
'Ezi connect' cable connector for water heater models:
INFINITY 32, 26i, ENVIRO & HD/HDC Series
F
Three
Cables
Four
Cables
F F F
CONNECTING COMMUNICATION CABLES TO THE WATER HEATER
Communication cables connect the water heater to water controllers and operate at an extra low voltage (12 Volts DC) which is supplied from the water heater. Communication cables are supplied with the water controllers (15m) and are fitted with spade terminals for connection to water heater. Up to two cables can be connected directly to the ‘Ezi connect’ cable connector at the water heater. Extension cables are available from Rinnai. Alternatively, two core sheathed (double insulated) flex with minimum cross sectional area of 0.5mm² may be used. Cable lengths must not exceed 20 metres.
DO NOT attempt to connect cables to the 'Ezi connect' cable connector at the water heater unless the electric power to the water heater is switched ‘off’ otherwise damage to electrical components may occur.
To connect up to two cables to the 'Ezi connect' cable connector
1. Isolate the electric power supply by switching the power point off and removing the power plug of
the water heater from the electric power socket.
2. Remove the retaining screw of the 'Ezi connect' cable connector at the base of the appliance.
3. Swing the 'Ezi connect' cable connector door open and thread the cable through the weather seal
of the cable access hole in the direction shown allowing sufficient cable length so that the sheath of the cable can be secured with cable clamp supplied with the transceiver.
4. Loosen screw terminals & and connect the cable spade connectors to these terminals and
re-tighten. Polarity is not important, either wire colour can be connected to either terminal.
5. Return the 'Ezi connect' cable connector to the original position taking care not to damage cable
wires in the process and replace the retaining screw .
Connecting Three or Four Controllers
Repeat steps 1, 2 and 3 above.
To connect three or four cables, separate all the cables to be fitted into pairs. Cut off the existing spade connectors from each pair and re­terminate each pair into a new spade connector (available from your local electrical component retailer) so that there are only two sets of spade connectors (4 spade connectors in total) to be terminated.
Repeat steps 4 and 5 above.
Rinnai Australia 33 Installation Manual
COMMISSIONING
TESTING
1. Before final connection of the water heater purge gas, hot water and cold water supply lines. Swarf in either the gas or water supplies may cause damage.
2. Turn on gas and cold water supplies.
3. Test for water leaks and gas escapes near the unit.
4. Isolate gas supply. Remove test point screw located on the gas inlet connection and attach pressure gauge.
5. Turn the power 'on' at the power point socket and turn on gas.
6. If water controllers are fitted, ensure that the controllers are 'ON', select the maximum delivery temperature and open ALL available hot water taps including the shower. If remote controllers are not fitted, simply open all available hot water taps. (CAUTION: Ensure building occupants do not have access to hot water outlets during this procedure.)
7. Operate ALL other gas appliances at their maximum gas rate, in accordance with manufacturers instructions.
8. With all gas appliances in operation at maximum gas rate, the pressure should read between
1.13 - 3.0 kPa on Natural Gas. On LPG the pressure should be 2.75 - 3.0 kPa. If the pressure is lower, the gas supply is inadequate and the appliance will not operate to specification. It is the Installers responsibility to check the gas meter, service regulator and pipe work for correct operation/sizing and rectify as required. Note that the gas regulator on the appliance is electronically controlled and factory pre-set. Under normal circumstances it DOES NOT need adjustment during installation.
9. Close hot water taps including the shower.
10. Inspect and clean the strainer located on the cold water inlet connection. This procedure may need to be repeated to ensure the strainer remains clear, especially on new installations.
11. If water controllers are fitted, it is necessary to test their operation through the complete range of functions (refer to the Operation sections of this manual).
12. Confirm the hot water delivery temperature(s) using a thermometer. If controllers are fitted, ensure temperatures exceeding 50°C cannot be selected on bathroom or ensuite controllers. Refer to the section ‘Delivery Temperature’ below for more details.
13. After testing is completed, explain to the householder the functions and operation of the water heater and water controllers (if fitted). Ensure the “PRODUCT RECORDS” on page 36 of this manual is filled in and that the booklet is handed to the customer. Reminding the customer to complete the Warranty Card and forward to Rinnai.
DELIVERY TEMPERATURE
"50°C Compliant" appliances are 'factory set' to deliver a maximum temperature not exceeding 50°C. However, they have an incremental adjustment mechanism that allows the installer to increase the appliance delivery temperature incrementally from the 'Factory Set’ value to temperatures exceeding 50°C. This is intended to enable compensation for temperature losses in the pipe-work between the water heater and any outlets and achieve the required temperature at the outlet. Instructions for incremental temperature adjustment are located in the instruction pocket inside the appliance front cover.
For “Solar” appliances (labelled S20, S26 or “Solar” on the front cover)
To meet regulatory requirements, the delivery temperature is factory set and sealed. This setting cannot be altered.
For all other models
Rinnai continuous flow water heaters are factory pre-set to various maximum delivery temperatures depending on model and their intended application. For the majority of applications, the factory pre­set temperature is appropriate. In the unlikely event it is not this setting can be increased or decreased by the installer. Instructions for changing the maximum delivery temperature are located in the instruction pocket inside the appliance front cover.
Rinnai Australia 34 Installation Manual
COMMISSIONING
GAS PRESSURE SETTING
The regulator is electronically controlled and factory pre-set. Under normal circumstances it does not require adjustment during installation.
Make adjustments only if the unit is not operating correctly and all other possible causes for incorrect operation have been eliminated.
Instructions for Gas Pressure Setting are to be found in the instruction pocket located inside the appliance front cover.
COMMISSIONING CHECK LIST
A commissioning check list is provided on the appliance front cover to enable the installer to step through the correct commissioning procedure when installing a Rinnai Continuous Flow water heater.
The check list can also assist the installer to identify potential installation errors that may prevent the appliance from operating correctly.
Rinnai Australia 35 Installation Manual
ACCESSORIES
Recess Box:
These allow the appliance to be recessed into the cavity of the wall saving precious space. Suitable for painting.
Pipe Cover:
These hide the plumbing pipe-work and valves underneath the appliance. Two pipe covers can be joined together for longer pipe-work.
Security Cage:
Protect the gas booster unit from theft and damage.
Security Bracket:
Prevent theft of the gas booster by securing it with the custom security bracket.
Sideways Flue Diverter
Designed to redirect flue products when the gas booster is installed on a balcony.
Contact Rinnai for further information about our accessory range and model suitability details.
PRODUCT RECORDS
Please take a moment to record the following information below for your own records.
Model No: REU- Serial No:
Your Retailer:
Address:
Contact Number: ( )
Purchase Date: / /
Your Installer:
Address:
Installers License No.:
Contact Number: ( )
Installation Date: / /
Certificate of Compliance No.:
Rinnai Australia 36 Operation/Installation Manual