![](/html/7d/7d2e/7d2ed371315455e2a6734f26c0a216fc7ff2a36297263f6f373064e4f355ab64/bg2.png)
Appliance must be installed with a Rinnai approved flue
system.
This appliance shall be installed in accordance with:
- Manufacturer’s installation instructions
- AS/NZS 5601
- Local regulations and municipal building codes
Installation, servicing and repair shall be carried out only by
authorised personnel.
Please retain this manual for future reference.
Warning
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury
or loss of life.
For more information about buying, living and servicing
of Rinnai appliances call: 0800 RINNAI (0800 746 624)
Rinnai New Zealand Limited
105 Pavilion Drive, Mangere, Auckland
PO Box 53177, Auckland Airport, Auckland 2150
Phone: (09) 257 3800, Fax: (09) 257 3899
Email: info@rinnai.co.nz, www.rinnai.co.nz
Important:
![](/html/7d/7d2e/7d2ed371315455e2a6734f26c0a216fc7ff2a36297263f6f373064e4f355ab64/bg3.png)
cnt:
About your Arriva 752 4
Safety 5
Clearances 6
General information 7
Operation without the remote 8
Operation using the remote 9
Care of your Arriva 752 11
Maintenance and servicing 12
Troubleshooting 14
Error codes 16
Abnormal flame pattern 17
Installation checklist 18
Installer details 18
Limited warranty 19
![](/html/7d/7d2e/7d2ed371315455e2a6734f26c0a216fc7ff2a36297263f6f373064e4f355ab64/bg4.png)
4 | Arriva 752 Operation Guide: 12219-A 01-12
About your Arriva 752
Beauty and efficiency rolled into one great fireplace. Elegant and stylish—with six beautiful fascia options and
modern quartz or pebble burn media. High performance and resource considerate, the Arriva 752 ensures the
highest heat output for the lowest energy consumption.
Auto overheat discharge vent
Room air return
Louvre, warm air discharge
Room air return
Burn media
Blockage indicator
for filter and louvre blockages
Double glazed
frame window
Control panel
Room air
return
Remote receiver window for
infra red remote (5 m range)
Error display
Displays error
codes
Operation indicator*
Indicates operation
status
Timer indicator
Indicates timer
program status
On/Off button
Turns the heater
on or off
* Control panel operating colours; red - on, green - standby, green flashing - error code indication
![](/html/7d/7d2e/7d2ed371315455e2a6734f26c0a216fc7ff2a36297263f6f373064e4f355ab64/bg5.png)
Arriva 752 Operation Guide: 12219-A 01-12 | 5
Safety
Important
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
- THE HEATER MUST NOT BE USED IF THE GLASS OR PANELS ARE DAMAGED
- DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE
- DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE
- DO NOT MODIFY THIS APPLIANCE
- DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION
Do not restrict warm air discharge
by placing articles in front of the
appliance.
This appliance must not be used
for any other purpose other than
heating.
Children should be supervised at
all times to ensure they do not
play with the appliance. Hand or
body contact with the appliance
must be avoided.
Do not allow anyone to sit, lean
or sleep directly in front of the
appliance.
Do not place articles on the top
panel or obstruct the automatic
overheat discharge vent.
Do not unplug the appliance
while it is operating. Do not use
power boards or double adaptors
to operate this appliance.
Do not allow anyone to post
articles through into the heater.
Do not spray aerosols while the
appliance is operating. Most
contain butane gas which can
be a fire hazard if used near the
appliance.
![](/html/7d/7d2e/7d2ed371315455e2a6734f26c0a216fc7ff2a36297263f6f373064e4f355ab64/bg6.png)
6 | Arriva 752 Operation Guide: 12219-A 01-12
Clearances
The clearances listed below are minimum clearances unless otherwise stated.
Clearances around the heater
The appliance must not be
installed where curtains or other
combustible materials (coffee
tables, couches etc.) could come
into contact with the heater. In
some cases curtains may need
restraining.
Floor protection
Heat emanating from this fire may
over time affect the appearance of
some materials used for flooring,
such as, carpet, vinyl, cork or
timber. This may be amplified if
the air contains cooking vapours
or cigarette smoke. To avoid this
occurring, it is recommended that
a mat be placed in front of the
appliance.
Mantels and surrounds
Mantels and surrounds are allowed
providing they conform to the
minimum clearances shown. These
clearances are important as they:
- allow heat to escape in the
event of a power failure
during operation
- allow optimum performance
of the heater (room air return)
- allow access to the side mesh
filters
Clearance calculation example
At a 75 mm vertical clearance, the
maximum mantel depth is 25 mm.
For every 25 mm of added mantel
depth, there must be an additional
25 mm of vertical clearance. For
example a mantel depth of
100 mm requires a vertical
clearance of 150 mm
100 mm
1000 mm
100 mm
250 mm
Arriva 752 mantel clearances
Arriva 752 surround clearances
Clearances required around the heater when operating