Rigol DP811, DP831, DP821 User guide

RIGOL
User’s Guide
DP800 Series Programmable
Linear DC Power Supply
May 2015
RIGOL

Guaranty and Declaration

Copyright
© 2012 RIGOL Technologies, Inc. All Rights Reserved.
Trademark Information
RIGOL is a registered trademark of RIGOL Technologies, Inc.
Publication Number
UGH04107-1110
Software Version
00.01.14 Software upgrade might change or add product features. Please acquire the latest version of the manual from RIGOL website or contact RIGOL to upgrade the software.
Notices
RIGOL products are cove red by P.R.C. and f oreign pa tents, issue d and pendin g. RIGOL reserves the right to modify or change parts of or all the specifications
and pricing policies at company’s sole decision.
Information in this publica tion re places all previ ously corresponding material. Information in this publication is subject to change without notice. RIGOL shall not be liable for either incidental or consequential losses in
connection with the furnishing, use or performance of this manual as well as an y information contained.
Any part of this document is forbidden to be copi e d, ph otoc o pie d or rearranged
without prior written approval of RIGOL.
Product Certification
RIGOL guar antees this pr oduct confo rms to the national and industrial standards in China as well as the ISO9001:2008 standard and the ISO14001:2004 standard. Other international standard conformance certif ication is in progress.
Contact Us
If you have any problem or requirement when using our products or this manual, please contact RIGOL. E-mail: service@rigol.com Website: www.rigol.com
DP800 User’s Guide I
RIGOL

Safety Requirement

General Safety Summary

Please review the following safety precautions carefully before putting the instrument into operation so as to avoid any personal injury or damage to the instrument and any product connecte d to it. To prevent potential haza rds, please us e the instrument only specified by this manual.
Use Proper Power Cord.
Only the power cord designed for the instrument and authorized for use within the local country could be used.
Ground the Instrument.
The instrument is grounded through the Protective Earth lead of the power cord. To avoid electric shock, it is e ssential t o connect the ea rth terminal of the power cord to the Protective Earth terminal before connecting any inputs or outputs.
Connect the Probe Correctly.
If a probe is used, do not connect the ground lead to high vol tage since it has isobaric electric potential as the ground.
Observe All Terminal Ratings.
To avoid fire or shock hazard, observe all ratings an d markers on the instrume nt and check your manual for more information about ratings before connecting the instrument.
Use Proper Overvoltage Protection.
Make sure that no overvoltage (such as that caused by a thunderstorm) can reach the product, or else the operator might be exposed to the danger of electrical shock .
Do Not Operate Without Covers.
Do not operate the instrument with covers or panels removed.
Do Not Insert Anything Into the Holes of Fan.
Do not insert anything into the holes of the fan to avoid damaging the instrument.
Use Proper Fuse.
Please use the specified fuses.
Avoid Circuit or Wire Exposure.
Do not touch exposed junctions and components when the unit is powered.
II DP800 User’s Guide
RIGOL
Do Not Operate With Suspected Failures.
If you suspect damage occurs to the instrument, have it inspected by RIGOL authorized personnel before further oper at io ns. Any maintenance, adjustment or replacement especially to circuits or accessories must be performed by RIGOL authorized personnel.
Keep Well Ventilation.
Inadequate ventilation may cause an increase of instrument temperature which would cause damage to the instrument. So please keep the instrument well ventilated and inspect the intake and fan regularly.
Do Not Operate in Wet Conditions.
In order to av oid short circuiting t o the interi or of the device or electric shock, please do not operate the instrument in a humid environment.
Do Not Operate in an Explosive Atmosphere.
In order to avoid damage to the device or personal injuries, it is important to o perate the device away fr om an expl osive atmosphere.
Keep Product Surfaces Clean and Dry.
To avoid the influence of dust and/or moisture in the air, please keep the surface of the device clean and dry.
Electrostatic Prevention.
Operate the instrument i n an ele ctrostatic discha rge protectiv e envi ronment to avoid damage induced by static discharges. Always ground both the internal and external conductors of cables to release static before making connections.
Proper Use of Battery.
If a battery is supplied, it must not be exposed to high temperature or in contact with fire. Keep it out of the reach of children. Improper change of battery (note: lithium battery) may cause explosion. Use RIGOL specified battery on l y.
Handling Safety.
Please handle with care during transportation to avoid damage to keys, knob interfaces and other parts on the panels.
Do Not Provide Power for the Active Load.
In order to avoid the anti-irrigation current which leads to the power control loop out of control and damages the powered device, this power supply can only provide power for the pure load without the current output function.
DP800 User’s Guide III
RIGOL
WARNING
injury or loss of life.
CAUTION
damage to this product or other property.
DANGER
It calls attention to an operation, if not correctly pe rformed, could result in injury or hazard immediately.
WARNING
It calls attention to an operation, if not correctly pe rformed, could result in potential injury or hazard.
CAUTION
It calls attention to an operation, if not correctly pe rformed, could product.
Hazardous
Safety
Protective Terminal
Chassis
Test

Safety Terms and Symbols

Terms Used in this Manual. These terms may appear in this manual:
Warning statements indicate conditions or practices that could result in
Caution statements indicate conditions or practices that could result in
Terms Used on the Product. These terms may appear on the product:
result in damage to the product or other devices connected to the
Symbols Used on the Product. These symbols may appear on the product:
Voltage
Warning
Earth
Ground
Ground
IV DP800 User’s Guide
RIGOL

Allgemeine Sicherheits Informationen

Überprüfen Sie diefolgenden Sicherheitshinweise sorgfältigumPersonenschädenoderSchäden am Gerätundan damit verbundenen weiteren Gerätenzu vermeiden. Zur Vermeidung vonGefa hren, nutze n S ie bitte das Gerät nur so, wiein diesem Handbuchangegeben.
Um Feuer oder Verletzungen zu vermeiden, verwenden Sie ein ordnungsgemäßes Netzkabel.
Verwenden Sie für dieses Gerät nur das für ihr Land zugelassene und genehmigte Netzkabel.
Erden des Gerätes.
Das Gerät ist durch den Schutzleiter im Netzkabel geerdet. Um Gefahren durch elektrischen Schlag zu vermeiden , ist es unerlässlich, die Er dung durchzufüh ren. Erst dann dürfen weitere Ein- oder Aus gä nge verbunden werden.
Anschluss einesTastkopfes.
Die Erdungsklemmen der Sonden sindauf dem gleichen Spannungspegel des Instruments geerdet. SchließenSie die Erdungsklemmen an keine hohe Spannung an.
Beachten Sie alle Anschlüsse.
Zur Ve rm e idung von Feuer oder Stromschlag, beachten Sie alle Bemerkungen und Markierungen auf dem Instrument. Bef olgen Sie die Bedienun gsanleitung für weitere Informationen, bevor Sie weitere Anschlüsse an das Instrument legen.
Verwenden Sie einen geeigneten Überspannungsschutz.
Stellen Sie sicher, daß keinerlei Überspannung (wie z.B. durch Gewitter verursa cht) das Gerät erreichen kann. Andernfallsbestehtfür den Anwender die GefahreinesStromschlages.
Nicht ohne Abdeckung einschalten.
Betreiben Sie das Gerät nicht mit entfernten Gehäuse-Abdeckungen.
Betreiben Sie das Gerät nicht geöffnet.
Der Betrieb mit offenen oder entfernten Gehäuseteilen ist nicht zulässig. Nichts in entsprechende Öffnungen stecken (Lüfter z.B.)
Passende Sicherung verwenden.
Setzen Sie nur die spezifikationsgemäßen Sicherungen ein.
Vermeiden Sie ungeschützte Verbindungen.
Berühren Sie keine unisolierten Verbindungen oder Baugruppen, während das Gerät in Betrieb ist.
DP800 User’s Guide V
RIGOL
Betreiben Sie das Gerät nic h t i m Fehlerfall.
Wenn Sie am Gerät einen Defekt vermuten, sorgen Sie dafür, bevor Sie das Gerät wieder betreiben, dass eine Untersuchung durch RIGOL autorisiertem Personal durchgeführt wird. Jedwede W artun g, Einstellarbeit en oder Austausch v on Teilen am Gerät, sowie am Zubehör dürfen nur von RIGOL autorisiertem Personal durchgeführt werden.
Belüftung sicherstellen.
Unzureichende Belüftung kann zu Temperaturanstiegen und somit zu thermischen Schäden am Gerät führen. Stellen Sie deswegen die Belüftung sicher und kontrollieren regelmäßig Lüfter und Belüftungsöffnungen.
Nicht in feuc h te r Um g ebung betrei be n .
Zur Vermeidun g von Kurzschluß im Geräteinne ren und Stromschlag betreiben Sie das Gerät bitte niemals in feuchter Umgebung.
Nicht in explosiver Atmosphäre betreiben.
Zur Ve rm e idung von Pers onen- und Sachschäden ist es unumgängli ch, das Ger ät ausschließlich fernab jedweder explosiven At mosphäre zu betreiben.
Geräteoberflächen sauber und trocken halten.
Um den Einfluß von Staub und Feuchtigkeit aus der Luft auszuschließen, halten Sie bitte die Geräteoberflächen sauber und trocken.
Schutz gegen elektrostatische Entladung (ESD).
Sorgen Sie für eine elektrostatisch geschützte Umgebung, um somit Schäden und Funktionsstörungen durch ESD zu vermeiden. Erden Sie vor dem Anschluß immer Innen- und Außenleiter der V erbindungsleitung, um st atische Aufladung zu entladen.
Die richtige Verwendung desAkku.
Wenneine Batterieverwendet wird, vermeiden Sie hohe Temperaturen bzw. Feuer ausgesetzt werden. Bewahren Sie es außerhalbder Reichweitevon Kindern auf. UnsachgemäßeÄnderung derBatterie (Anmerkung: Lithium-Batterie) kann zu einer Explosion führen. VerwendenSie nur von RIGOL angegebenenAkkus.
Sicherer Transport.
Transportieren Sie das Gerät sorgfältig (Verpackung!), um Schäden an Bedienelementen, Anschlüssen und anderen Teilen zu vermeiden.
Vermeiden Sie das einprägen von Strom und Spannung an den Testklemmen.
Das DP800 Power Supply kann hierdurch zerstört werden , k eine akive Last. Das DP800 kann nur Strom und Spannungen leifern.
VI DP800 User’s Guide
RIGOL
WARNING
Schäden oder den Tod von Personen zur Folge haben können.
CAUTION
Schäden am Gerät hervorrufen können.
DANGER
weist auf eine Verletzung ode r Gefäh r dun g hin, die sof ort geschehen kann.
WARNING
weist auf eine V erletzung oder Gefäh rdung hin, die möglicherweise nicht sofort geschehen.
CAUTION
weist auf eine Verletzun g ode r Gefährdung hin und bedeutet, dass Gegenstände auftreten kann.

Sicherheits Begriffe und Symbole

Begriffe in diesem Guide. Diese Begriff e können in diese m Handbuch aufta uchen:
Die Kennzeichnung WARNING beschreibt Gefahrenquellen die leibliche
Die Kennzeichnung Caution (Vorsicht) beschreibt Gefahrenquellen die
Begriffe auf dem Produkt. Diese Bedingungen können auf dem Produkt erscheinen:
eine mögliche Beschädigung des Instruments oder anderer
Symbole auf dem Produkt. Diese Symbole können auf dem Produkt erscheinen:
Gefährliche Spannung
Sicherheits­Hinweis
Schutz-erde Gehäusemasse Erde
DP800 User’s Guide VII
RIGOL
CAUTION
WARNING
supply.

General Care and Cleaning

General Care
Do not store or leave the instrument where it may be exposed to direct sunlight for long periods of time.
Cleaning
Clean the instrument regularly according to its operating conditions. To clean the exterior surface, perform the following steps:
1. Disconnect the instrument from all power sources.
2. Clean the loose dust on th e outside of the i nstrumen t with a lint -f ree clot h (with a mild detergent or water). When cleaning the LCD, take care to av oid sca rifying it.
To avoid damage to the instrument, do not expose it to caustic liquids.
To avoid short-circuit and personal injury resulting from moisture, make sure the instrument is completely dry before reconnecting it to power
VIII DP800 User’s Guide
RIGOL

Environmental Consideratio ns

The following symbol indicates that this product complies with the requirements in WEEE Directive 2002/96/EC.
Product End-of-Life Handling
The equipment may contain substances that could b e harmf ul t o the envi ronm ent or human health. In order to avoid release of such substances into the environment and harm to human health, we encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused or recycled appropriately. Please contact your local authorities for disposal or recycling information.
DP800 User’s Guide IX
RIGOL

DP800 Series Overview

DP800 series is high-performance programmable line a r DC power supply. DP800 series which provides clear user interface, superb performance specifications, various analysis functions as well as various communication interfaces can fulfill versatile test requirements.
Main Features: User-friendly Design:
3.5 inch TFT display, can display multiple parameters and states at the same
time
Support Chinese/English interface and input method Novel and exquisite industrial design and easy operation Provide waveform display function to provide real-time and dynamic d isplay of
the output voltage/current waveform, clearly showing the output state and tendency of the instrument in together with the digital display of the voltage, current and power values
Provide dial display function, indicating the current output state using the dial
pointer by simulating the traditional power display mode
Provide on-line help system for easy acquisition of help information
Multiple Safety Protection:
Provide overvoltage/overcurrent protection function; users can set the
overvoltage and overcurrent parameters to realize effective protection of the load
Provide seco nd ary over-temperature protection function to realize double
over-temperatu re protection of the s of t ware and hardware
Provide intelligent fan speed control function; judge and control the fan speed
automatically according to the working condition to effectively reduce the fan noise
Provide fan failure check and alar m fu nction Provide keyboard lo ck function to avoid misop erat i on
Various Functions and Superb Performance:
Multi-channel output; up to 200W total output power; the output of each
channel can be controlled independently
Superb load regulation rate and linear regulatio n r ate Provide ultra-low output ripples an d noise Provide timing output function and support infinite and specified number of
cycles of output
Provide track function to track the channel voltage setting value and output
on/off status
Provide Sense fun ction to automaticall y compensate for the voltage drop caused
by the load lead in high current output.
Provide delay on/off out put f unction and sup port infinite or specified number of
X DP800 User’s Guide
RIGOL
cycles of channel on/off toggle
Support digital trigger (option) to realize digital trigger input and trigger output
functions
Support on-line analyzer (option) to perform on-line analysis of various statistic
parameters
Support monitor (option) to monitor the output according to the user-defined
monitor condition
Provide built-in recorder to perfor m background recording of the output state
after power-on according to certain record period
Provide de di cat ed p res et key to perf o rm one -key reset and one-key recall of the
commonly used output voltage and current configurations
Support serial and parallel output functions Support on-line self-test and manual calibration functions Provide store and recall function Support voltage and current linear programmable functions
Complete In te rface Configu rations and Fle xible Control Method:
Standard configuration interfaces: USB HOST, USB DEVICE, LAN (option),
RS232 (option), Digital I/O (option), rear panel output interface (D P81 1)
Support to extend a GPIB interface via the USB-GPIB int e rface conve rter
(option)
Support USB st orage device storage Support SCPI remote command control Conform to LXI Core 2 011 Devi ce instrument standard Provide standard 9 pin RS232 interface with flow control function Provide 4-wire digital I/O interface which supports the trigger input/output
function
DP800 User’s Guide XI
RIGOL
Tip

Document Overview

Chapter 1 Quick Start
Introduce the appearance and dimensi ons, front panel, rear panel as well as user interface of DP800. In addition, it provides the detail ed p roced ures of power connection, power-on inspection and fuse replacement as well as the method of rack mount installation of DP800.
Chapter 2 Front Panel Oper a tio n s
Introduce the functi on and operation method of each key at the front panel of DP800 in detail.
Chapter 3 Remote Control
Introduce how to realize the remote control of the instrument.
Chapter 4 Troubleshooting
Introduce the possible failures and their solutions when using DP800.
Chapter 5 Specifications
List the specifications of DP800.
Chapter 6 Appendix
Provide the accessory and option list as well as the warranty information of DP800.
Index
Provide keyword se a rch to quickly loca t e the desired informa tion.
For the newest version of this manual, download it from RIGOL officia l website
www.rigol.com).
(
XII DP800 User’s Guide
RIGOL
Model
Number of Channels
Channel Output Voltage/Current
DP832
3
30V/3A, 30V/3A, 5V/3A
DP831
3
8V/5A, 30V/2A, -30V/2A
DP821
2
60V/1A, 8V/10A
DP811
1
Range1: 20V/10A; Range2: 40V/5A
Format Conventions in this Manual
1. Key
The function key at the front panel is denoted by the format of "Key Name (Bold) + Text Box" in the manual. For example, Utility denotes the "Utility" key.
2. Menu
The menu item is denoted in the following two modes in this manual. (1) The menu item can be denoted by the format of "Menu Word (Bold) +
Character Shading". F or example, System denotes the "System" item under Utility.
(2) The menu item can be denoted by the screenshot of the menu key. For
example,
.
3. Operation Step
The next step of the operation is denoted by an arrow "" in the manual. For example, Utility System denotes pressing Utility at the front panel and then pressing System.
Content Conventions in this Manual
DP800 series programmable linear DC power supply includes the following models. Unless otherwise noted, this man ual ill ustrates the functions and ope r a tion methods of DP800 series by taking DP832 as an example.
DP800 User’s Guide XIII
RIGOL Contents
Contents
Guaranty and Declaration ......................................................................... I
Safety Requirement ................................................................................. II
General Safety Summary........................................................................... II
Safety Terms and Symbols ....................................................................... IV
Allgemeine Sicherheits Informationen ........................................................ V
Sicherheits Begriffe und Symbole ............................................................. VII
General Care and Cleaning ..................................................................... VIII
Environmental Considerations ................................................................... IX
DP800 Series Overview ........................................................................... X
Document Overview ............................................................................. XII
Chapter 1 Quick Start ........................................................................ 1-1
General Inspection ................................................................................. 1-2
Appearance and Dim e nsions ................................................................... 1-3
Front Panel ............................................................................................ 1-4
Rear Panel ........................................................................................... 1-11
To Connect to Power ............................................................................ 1-13
Power-on Inspection ............................................................................. 1-14
To Replace the Fuse ............................................................................. 1-14
User Interface ...................................................................................... 1-16
To Use the Built-in Help System ............................................................. 1-18
To Rack Mount the Instrument .............................................................. 1-19
To Install a Single Instrument ......................................................... 1-19
To Install Two Instruments ............................................................. 1-26
Chapter 2 Front Panel Operations ...................................................... 2-1
Constant Voltage Output ......................................................................... 2-2
Constant Current Output ......................................................................... 2-6
Power Supply Series and Parallel Connections ........................................... 2-8
Power Supply Series Connect i on ........................................................ 2-8
Power Supply Parallel Connection ...................................................... 2-9
Track Function ..................................................................................... 2-10
To Enable the Track Function .......................................................... 2-10
To Track the On/Off Status of the Channel Output............................. 2-12
Sense Working Mode ............................................................................ 2-13
Timer and Delayer ................................................................................ 2-15
To Set the Timer Parameters........................................................... 2-16
To Enable the Timer ....................................................................... 2-25
To Set the Delay Parameters ........................................................... 2-26
To Enable the Delayer .................................................................... 2-30
Advanced Functions ............................................................................. 2-31
Recorder ....................................................................................... 2-32
XIV DP800 User’s Guide
Contents RIGOL
Analyzer (option) ........................................................................... 2-33
Monitor (option) ............................................................................ 2-36
Trigger (option) ............................................................................. 2-37
Display Setting ..................................................................................... 2-41
Brightness ..................................................................................... 2-41
Contrast ........................................................................................ 2-41
RGB Luminance ............................................................................. 2-41
Display Mo de ................................................................................. 2-42
Display Theme ............................................................................... 2-42
User-defined Start-up Interface ....................................................... 2-43
Store and Recall ................................................................................... 2-45
Browser ........................................................................................ 2-46
File Type ....................................................................................... 2-46
Save ............................................................................................. 2-47
Read............................................................................................. 2-49
Delete........................................................................................... 2-49
Copy and Paste .............................................................................. 2-50
Utility .................................................................................................. 2-51
I/O Configuration ........................................................................... 2-52
System Setting .............................................................................. 2-58
System Informat i on ........................................................................ 2-60
System La nguage .......................................................................... 2-60
Test/Calibration.............................................................................. 2-60
Print ............................................................................................. 2-61
Preset Setting ................................................................................ 2-62
Options ......................................................................................... 2-69
Key Locking ......................................................................................... 2-71
Chapter 3 Remote Control .................................................................. 3-1
Remote Control via USB ......................................................................... 3-2
Remote Control via LAN (option) ............................................................. 3-5
Remote Control via GPIB (option) ........................................................... 3-8
Remote Control via RS232 (option) ........................................................ 3-10
Chapter 4 Troubleshooting ................................................................. 4-1
Chapter 5 Specifications ..................................................................... 5-1
Chapter 6 Appendix ............................................................................ 6-1
Appendix A: Access ories and Options ...................................................... 6-1
Append i x B: Warranty ............................................................................ 6-2
Index ....................................................................................................... 1
DP800 User’s Guide XV
Chapter 1 Quick Start RIGOL

Chapter 1 Quick Start

The contents of this chapter are as follows:
General Inspection Appearance and Dim e nsions Front Panel Rear Panel To Connect to Power Power-on Inspection To Replace the Fuse User Interface To Use the Built-in Help System To Rack Mount the Instrument
DP800 User’s Guide 1-1
RIGOL Chapter 1 Quick Start

General Inspection

1. Inspect the shipping container for damage
Keep the damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness and the instrument has passed both ele ctrica l a nd mechanical tests.
The consigner or carrier shall be liable for the damage to instrument resulting from shipment. RIGOL woul d n ot be responsible for free maintenance/rework or replacement of the unit.
2. Inspect the instrument
In case of any damage, or defect, or failure, notify your RIGOL sales representative.
3. Check the accessories
Please check the accessories according to th e pack i ng li s ts . If the acce ssories are incomplete or damaged, please contact your RIGOL sales representative.
1-2 DP800 User’s Guide
Chapter 1 Quick Start RIGOL

Appearance and Dimensions

Figure 1-1 Front View Unit: mm
Figure 1-2 Side View Unit: mm
DP800 User’s Guide 1-3
RIGOL Chapter 1 Quick Start
1 2 3 4
11 10 9 8 7 6 5

Front Panel

This section introduces the front panel of DP800 serie s by takin g DP832 (as sh own in the figure below) as an example. The differences of different models are introduced separately.
Figure 1-3 DP832 Front Panel
1-4 DP800 User’s Guide
Chapter 1 Quick Start RIGOL
Press this key to select CH1 as the current channel and you can set
Press this key to select CH2 as the current channel and you can set
Press this key to select CH3 as the current channel and you can set
Press this key to enable or disable the output of the corresponding
Press this key and t h e prompt message asking whether to enable
the outputs of all the channels.
1. LCD
3.5 inches TFT display. It is used to display the system parameter setting, system output state, menu items, prompt messages, etc.
2. Channel (Range) Selection and Output Switch
For the multi-channel model, the function of this part is channel selection and output switch. For the single-channel model, the function of this part is range selection and output switch.
Multi-channel models (take DP832 as an example):
the parameters of this channel, such as voltage, current and overvoltage/overcurren t protection.
the parameters of this channel, such as voltage, current and overvoltage/overcurren t protection.
the parameters of this channel, such as voltage, current and overvoltage/overcurren t protection.
channel.
the outputs of all the channels will be dis played. Pres s OK to enable the outputs of all the channels. Pressing this key again will disable
DP800 User’s Guide 1-5
RIGOL Chapter 1 Quick Start
20V
10A
40V
5A
Press this key to select 20V/10A range as the current r an ge and
Press this key to select 40V/5A range as the current range and you Press this key to enable or disable the output of the channel.
Single-channel model (DP811):
you can set the parameters of the channel, such as voltage, current and overvoltage/overcurrent protection.
can set the parameters of the channel, such as voltage, current and overvoltage/overcurrent protection.
3. Parameter In p ut Area
The parameter input area is as shown in the figure below. This area includes the direction keys (unit selection keys), numeric keyboard and knob.
(1) Direction keys and unit selection keys
Direction keys: move the cursor. When setting parameters, use the
up/down direction key to increase or reduce the value at the cursor.
Unit selection keys: whe n usi ng the nume ric ke yboa rd t o i nput par ameter s,
1-6 DP800 User’s Guide
Chapter 1 Quick Start RIGOL
Restore all the settings of the instrument to default values or
Confirm the parameter setting. Press and hold this key to lock the front pane l keys; at this point,
(2012) to unlock the front panel keys.
the keys are use d to enter the v oltage units (V and mV) or the current units (A and mA).
(2) Numeric Keyboard
Ring-type numeric keyboard: include numbers 0-9 and the decimal point. Press the corresponding key to directly input the number or decimal point.
(3) Knob
When setting parameters, rotate the knob to increase or reduce the value at the cursor. When browsing the setting objects (timer parameters, delay parameters, filename input, etc.), rotate the knob to quickly move the cursor.
4. Preset
recall the user-defined channel voltage/current configuration.
5. OK
the front panel keys (except the output on/off key o f each channel and the power switch key ) are not available. When
the keyboard lock password is disabled, press and hold this key again to unlock the front panel keys. When the keyboard lock password is enabled, you need to input the correct password
6. Back
Delete the character currently before the cursor. When the instrument is in rem ote mode, press t his key to return to local mode.
DP800 User’s Guide 1-7
RIGOL Chapter 1 Quick Start
8V/10A60V/1A
S S
Output
(1)
(3)
(1) (2)
7. Output Terminals
The output terminals of different models of DP800 series are different.
DP832:
DP821:
DP811:
(1) Channel output terminals: used to output the voltage and current of the
channel. (2) Ground terminal: this terminal is connected to the instrument chassis and
ground wire (the ground terminal of the power cord) and is in grounded
state. (3) Sense terminals: used to detect the actual voltage at the load terminal so as
to compensate for the voltage drop c a u s ed by the load l e ad.
1-8 DP800 User’s Guide
Chapter 1 Quick Start RIGOL
Press this key to enter the display parameter setting interface.
interface.
Press this key to enter the file store and recall interface. You can
and recall.
A
B
Connection methods of the output terminal:
Method 1: Connect the test lead to A of the output terminal.
Method 2: Rotate the outer nut of the output terminal counterclockwise and connect the test lead to B of the output terminal; then, rotate the outer nut of the output terminal clockwise. This connection method can eliminate the error caused by the resistance of the output terminal.
Note: Connect the posit ive terminal of the test lea d w ith the (+) terminal of the channel output and connect the negative terminal of the test lead with the (-) terminal of the channel output.
8. Function Menu Area
Users can set the brightness, contrast, RGB luminan ce, display mode and display theme. Besides, you can a lso define the start-up
save, read, delete, copy and paste files. The file types available for storage include state file, record file, timer f ile, delay file and bitmap file. The instrument supports internal and external storage
DP800 User’s Guide 1-9
RIGOL Chapter 1 Quick Start
Press this key to enter the system utility function setting interface.
configuration of Preset and install options.
Press this key to enter the advanced function setting interface. trigger (option) parameters.
Press this key to enter the timer and delayer setting interface. Press this key to open the built-in help system and press the
introductions, refer to "To Use the Built-in Help System".
interface.
The menu keys correspond to the menus above them menu.
Users can set the remote interface parameters, system parameters and print parameters. Besides, users can also calibrate the instrument, view system information, define the recall
Users can set the recorder, analyzer (option), monitor (option) and
Users can set the timer and delayer parameters as well as enable and disable the timer and delayer functions.
desired key to get the corresponding help information. F or detailed
9. Display Mode Switch/Return to the Main Interface
Switch between the current display mode and dial display mode. Besides, when the instrument is in a function interface (any
interface under Timer, press this key to exit the f unction interf ace and return to the main
10. Me nu Keys
respectively. Press any menu key to select the corresponding
11. Power Switch Key
Turn on or off the instrument.
, Display, Store and Utility),
1-10 DP800 User’s Guide
Chapter 1 Quick Start RIGOL
T6
.3A
T
3.
1
5A
AC 1
00V
A
C 1
1
5V
AC
23
0V
500V
A
O
pt
. O
p
t.
Op
t
.
T6.
3A
T3.15A
AC 100V AC 115V AC 230V
500VA
Opt. Opt.
Opt.
S
S+
1 2 3 4 5 6
10 9 8 7
11

Rear Panel

This section introduces the rear panel of DP800 series by taking DP832 and DP811 (as shown in the figures below) as examples. The introduction of each part is as shown in Table 1-1.
Figure 1-4 DP832 Rear Panel
Figure 1-5 DP811 Rear Panel
DP800 User’s Guide 1-11
RIGOL Chapter 1 Quick Start
No.
Name
Explanation
LAN Interface (option)
The instrument is connected to the local network via RJ45 interface
Connect the instrument (as "slave" device) to
Connect the instrument (as "host" device) to external
USB-GPIB interface converter (option)
4
Digital I/O (option)
Digital I/O interface
RS232 Interface (option)
Select the specification of the input voltage (100, 115 or 230; please refer to Table 1-2)
7
Power Socket
AC power input interface.
The specification of the fuse is related to the
panel of the instrument or refer to Table 1-3).
9
Fan
Input Power Requirement
Corresponding relations of the AC input power frequency, voltage and the specification of the fuse.
DP811 provides this interface. The function of this Terminals" at the front panel.
Table 1-1 DP800 rear panel explanation
1
2 USB DEVICE
3 USB HOST
5
6 Voltage Selector
8 Fuse
10
11 Output Interface
external USB device (such as PC)
USB device (such as USB storage device); extend a GPIB interface for the power supply using
Serial communication interface
instrument model and actual input voltage (please refer to the "Input Power Requirements" at the rear
interface is the same as that of the "Output
Note: The "Output Terminals" at the front panel and "Output Interface" at the rear panel cannot be used for output at the same time. You can only select one of them for output at each time (wherein, the output terminals at the front panel provide higher output accuracy).
1-12 DP800 User’s Guide
Loading...