Page 1 of 9
Rev. D
SAFETY DATA SHEET
Section 1 – Product & Company Identification
Product Name:
Rechargeable Advanced Lithium Ion Batteries
P/N Cells:
US18650VTC4
Product Catalog No.:
43323, 43328, 44693, 44698, 44848, 44853, 48483
Recommended Use:
RIDGID Press Tools
Company Information:
North America
Ridge Tool Company
400 Clark Street
Elyria, Ohio 44035-6001
1-800-519-3456
(8:00 am – 5:00 pm EST, M-F)
Emergency Telephone
call 9-1-1 or local emergency number
www.RIDGID.com
Australia
Ridge Tool Australia
127 Metrolink Circuit
Campbellfield, VIC 3061
1-800-743-443
(8:30 am – 5:00 pm AEST, M-F)
Emergency Telephone
call 000 or local emergency number
www.RIDGID.com.au
Issue Date: March 3, 2017
Section 2 – Hazards Identification
This product is defined as an article per US OSHA 29CFR 1910.1200 (HazCom 2012).
GHS Label Elements: Not applicable
The materials in these Li-Ion batteries are hermetically sealed in a case and do not leak
electrolyte under normal usage conditions. However, if exposed to a fire, explosion,
extreme abuse, misuse or improper disposal that results in breaching of the battery cell
case, hazardous materials may be released. Also, battery terminal contact with other
metals may generate heat or cause electrolyte leakage. Electrolyte is flammable. Direct
contact with electrolyte may cause severe irritation and chemical burns. Short-term skin
exposure may cause chemical burns and sores. Inhalation and injection are not
anticipated routes of exposure with leakage of small amounts of electrolyte.

Page 2 of 9
Rev. D
Product Name………………………: Rechargeable Advanced Lithium Ion Batteries
Section 3 – Composition / Information On Ingredients
Composition:
- Cathode: Lithium nickel cobalt manganese oxides (active material)
Polyvinylidene fluoride (binder)
Graphite (conductive material)
- Anode: Graphite (active material)
Polyvinylidene fluoride (binder)
- Electrolyte: Organic solvent (non-aqueous liquid)
Lithium salt
Does not contain heavy metals such as mercury, cadmium, lead or chromium
Average Operating
Voltage (V)
Section 4 – First Aid Measures
EYE CONTACT:
If contents from an opened battery encounters the eyes, immediately flush eyes
thoroughly with water and continue flushing for at least 15 minutes without rubbing.
Seek medical attention.
SKIN CONTACT:
If the contents from an opened battery comes in contact with the skin, wash with
soap and water. If irritation persists or contact has been prolonged, seek medical
attention.
INHALATION:
If exposure to fumes or dusts occurs, remove immediately to fresh air and seek
medical attention.
INGESTION:
If contents from an opened battery are swallowed, do not induce vomiting. Seek
medical attention immediately.

Page 3 of 9
Rev. D
Product Name………………………: Rechargeable Advanced Lithium Ion Batteries
Section 5 – Fire Fighting Measures
In case of fire use CO2 or CLASS D fire extinguisher.
In case battery burns with other combustible, use corresponding fire extinguisher.
Corrosive fumes may be present during fire. Use protective equipment (gloves, breathing
apparatus, goggles etc.)
Gases from the burning fire will include Hydrogen Fluoride, Carbon oxides, Hydrocarbons
among others.
Section 6 – Accidental Release Measures
PERSONAL PRECAUTIONS:
Use rubber gloves and safety glasses, and a gas mask for organic gases when
handling leaking battery. Move batteries and contents away from open fire.
ENVIRONMENTAL:
No additional information.
CLEAN-UP MEASURES:
Spills and leaks are unlikely because cells are contained in a hermetically sealed
case. If the battery case is breached, wear protective clothing that is impervious
to caustic materials and absorb or pack spill residues in inert material.

Page 4 of 9
Rev. D
Product Name………………………: Rechargeable Advanced Lithium Ion Batteries
Section 7 – Handling And Storage
HANDLING:
Accidental short circuit (contacting positive and negative battery terminals with a
conductive object) will bring high temperature evaluation to the battery as well as
shorter battery life. Be sure to avoid prolonged short circuit since the heat can
burn attendant skin and can even rupture the battery cell case. Batteries placed in
bulk containers should not be shaken. Metallic objects in tool boxes can cause
short circuit. Do not disassemble, remodel, or solder.
CHARGING:
This battery is designed for recharging. Charge battery before use. Observe the
specified charging instructions since incorrect charging can cause a rise in internal
gas pressure which may result in damaging heat generation or cell rupture and/or
venting.
STORAGE:
Store in a cool, well-ventilated location. Prevent condensation on cell or battery
terminals. Store within the recommended temperature range of -4°F (-20°C) and
113°F (45°C). Do not expose to temperature above 140°F (60°C). Avoid exposure
to static electricity so that no damage will be caused to the protective circuitry of
the battery pack. Do not store with metal jewelry, metal covered tables, or metal
belts.
CAUTION: Do not dispose in fire, mix with other battery types, charge above
specified rate, connect improperly, or short circuit, which may result in
overheating, explosion, or leakage of cell contents.

Page 5 of 9
Rev. D
Product Name………………………: Rechargeable Advanced Lithium Ion Batteries
Section 8 – Exposure Controls / Personal Protection
EXPOSURE GUIDELINES:
Not specified
ENGINEERING CONTROLS:
None required under conditions of normal use. Provide appropriate ventilation in
case of electrolyte leakage or exposure.
PERSONAL PROTECTIVE EQUIPMENT:
• Eye Protection
None required under conditions of normal use, safety goggles in case of
electrolyte leakage.
• Skin Protection
None required under conditions of normal use, safety gloves in case of
electrolyte leakage.
• Respiratory Protection
None required under conditions of normal use, gas mask in case of
electrolyte leakage.

Page 6 of 9
Rev. D
Product Name………………………: Rechargeable Advanced Lithium Ion Batteries
Section 9 – Physical And Chemical Properties
Appearance
Physical State Sealed Battery
Form Mostly cylindrical
Color No data available
Odor No data available
Odor Threshold No data available
pH No data available
Melting point/freezing point No data available
Initial boiling point and boiling range No data available
Flash point No data available
Evaporation rate No data available
Flammability (solid, gas) No data available
Upper/lower limit on flammability or explosive limits
Flammability limit - upper (%) No data available
Flammability limit - lower (%) No data available
Explosive limit – upper (%) No data available
Explosive limit – lower (%) No data available
Vapor pressure No data available
Vapor density No data available
Relative density No data available
Solubility(ies)
Solubility in water No data available
Solubility (other) No data available
Partition coefficient (n-octanol/water) No data available
Auto-ignition temperature No data available
Decomposition temperature No data available
Viscosity No data available

Page 7 of 9
Rev. D
Product Name………………………: Rechargeable Advanced Lithium Ion Batteries
Section 10 – Stability And Reactivity
STABILITY:
Since batteries utilize a chemical reaction they are considered a chemical product.
As such, battery performance will deteriorate over time, even if stored for a long
period of time without being used. In addition, if the various usage conditions such
as charge, discharge, ambient temperature, etc. are not maintained within the
specified ranges the life expectancy of the battery may be shortened or the device
in which the battery is used may be damaged by electrolyte leakage. The battery
is stable under normal operating conditions.
CONDITIONS TO AVOID:
Open flames, heat, sparks and moisture. Battery should not be incinerated,
crushed, or abused. Do not subject battery to temperatures in excess of 140°F
(60°C).
INCOMPATIBLE MATERIALS:
No additional information known.
DECOMPOSITION PRODUCTS MAY INCLUDE:
No additional information known.
POSSIBILITY OF HAZARDOUS REACTIONS:
No additional information known
Section 11 – Toxicological Information
ACUTE TOXICITY: No further toxicological data known.
CHRONIC: No further toxicological data known.
SENSITIZATION: No further toxicological data known.
REPRODUCTIVE EFFECTS: No further toxicological data known.
TERATOGENIC EFFECTS: No further toxicological data known.
MUTAGENICITY: No further toxicological data known.
SYNERGISTIC MATERIALS: No further toxicological data known.
CARCINOGENICITY: No further toxicological data known.

Page 8 of 9
Rev. D
Product Name………………………: Rechargeable Advanced Lithium Ion Batteries
Section 12 – Ecological Information
ECOGICAL INFORMATION:
No information available.
Section 13 – Disposal Consideration
WASTE DISPOSAL:
Li-Ion batteries should not be incinerated or subjected to temperatures in excess
of 140°F (60°C). Such treatment can cause cell rupture. In the event of disposal,
dispose only in accordance with federal, state and local regulations.
These Li-Ion batteries are classified as hazardous waste and are not safe for
disposal in the normal waste stream. The Ridge Tool Company encourages
recycling, as these batteries do contain recyclable materials that can be reused.
The battery packs bear the Rechargeable Battery Recycling Corporation (RBRC)
symbol, indicating RIDGID has already paid the cost of recycling the lithium-ion
battery packs once they have reached the end of their useful life. For recycling
center locations, call 1-800-822-8837.
Section 14 – Transportation Information
UN Number: 3480
Proper Shipping Name: Lithium Ion Batteries
This battery is less that 100WH and has successfully passed UN safety testing. Batteries
are packaged in a manner that prevents short circuits and other damage that could lead
to failure.
Regulations governing dangerous goods will be relevant when transporting batteries.
Follow applicable laws and regulations for transport and disposal.
Special procedures must be followed in the event batteries are damaged, including
inspection and repacking. Damaged or defective batteries must not be transported by
air.

Page 9 of 9
Rev. D
Product Name………………………: Rechargeable Advanced Lithium Ion Batteries
Section 15 – Regulatory Information
Check with the appropriate regulatory agencies as regulations may have quantity
restrictions, operator variations, or other special provisions
Section 16 – Other Information
Prepared by: Ridge Tool Company (Operating Standard 6-416)
Issue Date: 3 March 2017
Last Revision Date: 19 May 2016
RIDGE TOOL BELIEVES THE STATEMENTS, TECHNICAL INFORMATION AND RECOMMENDATIONS
CONTAINED HEREIN ARE RELIABLE BUT THEY ARE GIVEN WITHOUT WARRANTY OR GUARANTEE
OF ANY KIND, EXPRESSED OR IMPLIED, AND WE ASSUME NO RESPONSIBILITY FOR ANY LOSS,
DAMAGE OR EXPENSE, DIRECT OR CONSEQUENTIAL, ARISING OUT OF THEIR USE.