Rice Lake IQ plus 390HE User Manual

Page 1
SURVIVOR
This Operator Card describes the 390HE LCD display, weighing and counting operations.
®
390HE Digital Weight Indicator
Warning
Do not open the indicator enclosure! Refer all repairs and modifications to
your distributor or service technician.
LCD Display and Annunciators
The 390HE display uses a set of LCD annunciators to provide additional information about the value being displayed. The illustration below shows these annunciators and their meanings.
G
The displayed weight is a gross weight.
The displayed weight is a net weight.
N
Scale is at standstill or within the specified motion band. Some operations, including zero, tare, and printing functions, can only be done when the standstill symbol is shown.
Center of zero. Gross weight is within 0.25 graduations of zero. This annunciator lights when the scale is zeroed.
Indicates that a tare has been entered. The tare value can be entered by pressing the the keypad or by sending the KTARE EDP command.
TARE
key on
lb, kg, PC
Three arrow annunciators on the right side of the LCD display indicate the units associated with the displayed value. The bottom arrow annunciator (PC) is lit when the indicator is in piece count mode. The top and middle arrows, labeled lb and kg, show primary and secondary units, as described below:
If the displayed weight is in pounds, the top arrow (lb) is lit; if kilograms, the middle arrow (kg) is lit.
If the primary unit of weight is pounds, the middle (kg) arrow is lit for secondary units— or, if the primary unit is kilograms, the top (lb) arrow is lit for secondary units, unless the secondary unit of weight is the same as the primary unit.
If neither primary nor secondary units are pounds or kilograms, the top arrow is used as a primary units annunciator and the middle arrow is used as the secondary units annunciator.
A set of replacement overlay decals is included in the parts kit for units other than pounds and kilograms.
Gross mode
August 2002
Net mode
Standstill
Center of zero
Tare in system
Low battery (not used)
lb kg PC
Primary
Displayed units
Secondary
Piece count mode
Page 2
2
Weighing Operations
The illustration below shows the 390HE keypad and normal mode key functions.
ZERO
Set gross weight
to zero
GROSS
NET
B/N
MODE ENTER SAMPLE PRINT
Acquire tare
Switch between
gross, net, and
piece count mode
NORMAL MODE KEY FUNCTIONS
Basic 390HE weighing operations are summarized below:
Toggle Gross/Net/Piece Count Mode
Press the between gross, net, and piece count modes. If a tare value has been entered or acquired, the net value is the gross weight minus the tare. If access to piece count mode is disabled, pressing the switches between gross and net modes only.
Gross mode is shown by the is shown by the shown by the LCD annunciator adjacent to the the right edge of the display.
Toggle Units
Press the secondary units. The units annunciator arrow on the right side of the LCD display points to the units identifier.
Zero Scale
GROSS/NET
UNITS
key to switch the display mode
GROSS/NET
G
annunciator; net mode
N
annunciator. Piece count mode is
key
PC
at
key to switch between primary and
1. In gross mode, remove all weight from the scale and wait for the standstill annunciator
().
2. Press the
key. The center of zero
ZERO
() annunciator lights to indicate the scale is zeroed.
TARE
T
T
Acquire Tare
UNITS
Units
Switch between
primary and
secondary units
1. Place container on scale and wait for the standstill annunciator ( ).
2. Press the of the container.
3. Net weight is displayed and the annunciator lights to show the tare value was acquired.
Remove Stored Tare Value
1. Remove all weight from the scale and wait for the standstill annunciator ( ).
2. Press the goes off, indicating the tare value has been removed.
Print Ticket
1. Wait for the standstill annunciator ( ).
2. Press the the serial port.
PRINT
Send data to
serial port
TARE
key to acquire the tare weight
ZERO
key. The annunciator
PRINT
key to send weight data to
SURVIVOR 390HE Operator Card
Page 3
Counting Operations
The illustration below shows the 390HE keypad and piece count mode key functions.
ZERO
Not used
Switch between gross, net,
GROSS
MODE ENTER SAMPLE PRINT
and piece count mode
NET
B/N
TARE
T
T
Acquire tare /
acquire sample
change sample quantity
UNITS
Units
New sample /
PRINT
Send data to
serial port
(CFMT format)
COUNTING MODE KEY FUNCTIONS
NOTE: Legal-for-trade applications require product to be sold by weight rather than an equivalent parts
count. Operator access to piece count mode is disabled when the indicator is shipped from the factory. To use piece count mode, access must be enabled when the indicator is configured.
Piece count mode is entered by pressing the (
GROSS/NET
) key from normal weighing mode. In count display mode, the display shows the number of parts rather than weight, the arrow annunciator at the right side of the LCD display points to piece count (PC), and pressing the
PRINT
key sends the CFMT
print format data string to the serial port. 390HE counting operations are summarized below:
MODE
If the weight of the sample quantity is insufficient for piece counting, the indicator automatically requests the next higher sample quantity by showing the
Addnnn
message again. If the sample quantity is at maximum (100) and the sample weight is still not sufficient, the indicator shows the message
Display Part Weight
CNTERR
.
To view gross and net weight of parts, press
Acquire Parts Sample
1. Place empty parts container on scale. Wait for the standstill annunciator ( ), then press
TARE
to acquire the tare weight of the
container.
2. Press
MODE
3. Press the
to enter piece count mode.
SAMPLE
(
UNITS
) key to enter
MODE
to switch from count display mode to
normal weighing mode.
Print Ticket
1. Wait for the standstill annunciator ( ).
2. Press the
key to send piece count data
PRINT
to the serial port.
sample acquisition mode.
4. The indicator display shows the message
Addnnn
, where
is the sample quantity to
nnn
be placed on the scale. Add the number of parts shown or choose a different sample size by pressing the
SAMPLE
key to scroll through
the selectable sample quantities (5, 10, 20, 50,
100).
5. Once the sample quantity is on the scale, press
ENTER
to calibrate the indicator for counting the new parts. The indicator display shows the message
–CNT–
as it acquires the sample weight, then switches to count display mode and shows the part quantity.
SURVIVOR 390HE Operator Card