Rice Lake HPX10-06C100, HPX10-12C080, HPX-10 Series Instruction Sheet

Battery Charging Instruction Sheet
WARNING
CAUTION
Note
Note
This instruction sheet contains important safety and operating instructions for model HPX-10 battery charger. Before using the battery charger, please read all instructions and cautionary information on the battery charger and the product using the battery.
Do not remove the cover
Disconnect charger from AC power before maintenance or cleaning
Charge only sealed or valve regulated, lead-acid, non-automotive, maintenance free rechargeable batteries
Enclosure may be hot during charging - Do Not Touch
Where hydrogen gas may be present, disconnect unit from AC power before connecting or disconnecting out
put connectors
Introduction
The HPX-10 is a two-stage, constant voltage battery charger with current limiting, current fold back, and automatic temperature compensation of the output voltage. It is protected against shorting and reversing the output terminals on a battery. There is one indicator light. It lights green to indicate when power is applied, there is a battery attached, or that the charger is in float mode. It lights yellow when the unit is charging a battery. A red light indicates a fault condition (short/reversed output connector).
This unit is designed to automatically switch charged. A single stage, parallel charger version is available for maintaining full charge on a battery when used with a permanent or intermittent parallel load. This unit is not designed to be used as a standalone power supply. For comprehensive operating instructions, refer to the manufacturer’s website: http://www.xenotronix.com/PDF/ Manuals/HPX10%20manual.pdf.
into a single stage, float charge mode when the battery is 70%
Operation
This section contains instructions for operating the battery charger.
1. Connect the power cord to a properly grounded outlet light should be green.
2. Plug the connector from the battery into the
Ensure that the “keys” on each connector line up.
connector on the battery charger.
The indicator light will be yellow until the battery is 95% charged. The light will then change to green, indicating a switch to float chrage mode. For 100% charge, the battery should remain connected to the charger for an additional three hours.
To keep battery at full capacity, it is recommended to leave the battery connected to the charger, in float charge mode, until ready to use. The battery can remain without damaging the battery.
supplying the correct input voltage. The indicator
on the charger in float charge mode indefinitely
August 2014
PN 96567 Rev D
Charging Tips
230 W. Coleman St. • Rice Lake, WI 54868 • USA
U.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0) 88 2349171
www.ricelake.com www.ricelake.mx www.ricelake.eu www.ricelake.co.in m.ricelake.com
For safer and more efficient charging, batteries should be charged with higher voltages when cold and lower voltages when warm. The HPX-10 incorporates automatic temperature compensation of the output voltage. For this feature to work properly, the battery and the charger need to be stabilized at the same temperature.
Troubleshooting
No indictor light - If the indicator light is dark, determine if the unit is connected to a light switch or power strip switch. If the power source is in the “on” position, then the unit may need repairs - contact RLWS.
No charge indicator, not charging - if the charger will not progress into charge mode, the battery is already charged. You can test this by attaching a battery to the charger that you know is not charged. If the unit begins charging then the previous battery is fully charged. If it does not, the unit may need repairs - contact RLWS.
Fault indicator - If the indictor light is red, the outputs are hooked up in reverse or shorted together. Check the connection to the battery. A completely dead battery will look like a short to the charger. If you suspect a dead battery, leave the charger attached to see if it goes into charge mode.
Charger will not switch into float mode - If the charger does not switch into float mode after 24 hours, the battery is probably damaged. Check the open circuit voltage of the battery for shorted cells.
Specifications
Operating Temperature: 32° - 104° F (0° - 40° C)
Storage Temperature: -40° - 178° F (-40° - 80° C)
Dimensions: 3.8" H x 2.8" W x 2.8" D
(9.65 cm H x 7.1 cm W x 7.1 cm D)
Weight: Less than 1.5 lb (0.68 kg) with
standard cables
Power Requirements: 120V~, 60Hz, .2 A RMS
Output Rating: @ 25 C
HPX10 - 06C100
Charge Amps (Imax): 1000 mA ± 2% Charge Voltage: 7.35 ± 0.15 Switch Amps (Isw)*: 133 mA ± 20% Float Voltage: 6.84 ± 0.06
HPX10 - 12C080
Charge Amps (Imax): 800 mA ± 2% Charge Voltage: 14.75 ± 0.30 Switch Amps (Isw)*: 107 mA ± 20% Float Voltage: 13.68 ± 0.12
Other Models:
Charge Amps (Imax): See label Charge Voltage: 2.45V/Cell Switch Amps (Isw)*: Imax/7.5 Float Voltage: 2.28V/Cell
© Rice Lake Weighing Systems August 29, 2014 PN 96567Rev D
Loading...