Rheem GX90-640, GX90-550 User Manual

Xtreme High-Input Gas Commercial Water Heaters
Available in 90 Gallon Tank-Type Models
550,000 BTU/Hr. thru 715,000 BTU/Hr.
Xtreme Gas Commercial Water Heaters are specifically designed to
minimize the difficulty of replacing failed water heaters and are versatile for new installations. These products are designed for applications requiring large quantities of hot water.
Construction Features:
GX90-550 and
GX90-640 Comply
With SCAQMD Rule 1146.2 for
Low NOxEmissions
Small
Jacket Diameters
• Space saving tank design –
maximizes installation adaptability by offering models with front side and rear side inlet/outlet water connections. Short heights and small jacket diameters result in greater installation flexibility.
• Patented multi-flue tank design – proprietary steel formulation,
patented multi-flue design, and two coats of high temperature porcelain enamel to maximize corrosion resistance result in a superior heat exchanger design.
• Low profile automatic flue damper –
low profile design minimizes over­all product height. Heavy duty vent hood supports are designed to withstand rigors of installation.
• Specialized burner assembly –
each model features five premix burners mounted into a metal face plate and sealed with a Viton gasket. Patented “quick release” manifold for easier service.
• Spark-To-Pilot ignition system –
Standard on all models. Provides reliable and energy saving ignition sequencing by igniting the pilot only when the thermostat calls for heat.
• System Sentinel diagnostic system –
Our exclusive diagnostic system, with glowing LED lights, verifies system operation sequence by sequence.
• Full port, full flow brass drain valve
LED
Short Floor-to-Vent
Heights
Multiple Water
Connection Options
(On Selected
Models)
Certifications and Ratings:
• Efficiency – these models have been tested according to ANSI test
procedures, and exceed the thermal efficiency and standby loss requirements of current ASHRAE standards (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states.
• Safety and construction – These products are design certified by U.L.:
a) For operation at 180°F. b) To meet all safety and construction requirements of ANSI Z21.10.3-2001 c) As an automatic storage or instantaneous water heater. d) As an automatic circulating tank water heater. e) For operation on combustible floors and in alcove installations.
CERTIFIED FOR A 150 PSI MAXIMUM WORKING PRESSURE (160 PSI FOR ASME MODELS).
Continued next page.
Xtreme Gas continued.
DIMENSIONAL INFORMATION All Dimensions Shown in English and Metric.
WATER CONNECTIONS APPROXIMATE
MODEL FRONT REAR NUMBER UNITS
ABCDEFG SIDE SIDE STD. ASME
GX90-550(A) inches 74.5 68 30 25 10 59 12 2905 945
mm 1892 1727 768 635 254 1509 25.4 51 51 905 945
GX90-640(A) inches 74.5 68 30 25 10 59 12 2905 945
mm 1892 1727 768 635 254 1509 25.4 51 51 905 945
GX90-715(A) inches 74.5 68 30 25 10 59 12 2905 945
mm 1892 1727 768 635 254 1509 25.4 51 51 905 945
GX90-500(A) inches 74.5 68 30 25 10 59 12 2905 945
mm 1892 1727 768 635 254 1509 25.4 51 51 905 945
GX90-600(A) inches 74.5 68 30 25 10 59 12 2905 945
mm 1892 1727 768 635 254 1509 25.4 51 51 905 945
GX90-680(A) inches 74.5 68 30 25 10 59 12 2905 945
mm 1892 1727 768 635 254 1509 25.4 51 51 905 945
All Models Require a 120V Power Source. (A) Suffix Indicates ASME Tank Construction Available.
SHIPPING WEIGHT
MAXIMUM DELIVERY In U.S. Gallons and Liters. (Includes useable storage and recovery for indicated times.)
MODEL TANK CAPACITY INPUT BTU/HR. TEMP. 5 10 15 20 30 45 60 120 180 Min. to Rec. NUMBER
GX90-550(A) 90 341 550,000 NAT 100°F GAL
GX90-640(A) 90 341 640,000 NAT 100°F GAL. 115 166 218 270 373 529 684 1304 1925 9
GX90-715(A) 90 341 715,000 NAT 100°F GAL. 121 179 236 294 410 583 756 1450 2143 8
GX90-500(A) 90 341 500,000 LP 100°F GAL. 103 144 184 225 305 427 548 1033 1518 11
L.P.
GX90-600(A) 90 341 600,000 LP 100°F GAL. 112 160 209 257 354 499 645 1227 1809 9
L.P.
GX90-680(A) 90 341 680,000 LP 100°F GAL. 118 173 228 283 393 558 722 1382 2041 8
L.P.
GALLONS
LITERS NAT. & L.P. RISE UNITS Min. Min. Min. Min. Min. Min. Min. Min. Min. Contents
107 152 196 241 330 463 596 1130 1663 10
37.7°C LTR. 407 575 743 911 1248 1752 2257 4276 6294
37.7°C LTR. 434 630 826 1022 1413 2000 2587 4936 7285
37.7°C LTR. 457 676 894 1113 1551 2207 2863 5487 8111
37.7°C LTR. 391 544 697 850 1156 1615 2073 3909 5744
37.7°C LTR. 422 606 789 972 1340 1890 2441 4643 6845
37.7°C LTR. 446 654 862 1070 1486 2110 2886 5230 7726
RECOVERY CAPACITIES Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temperature Rises.
MODEL INPUT BTU/HR. THERMAL 40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F NUMBER NATURAL & L.P. EFFICIENCY UNITS
GX90-550(A) 550,000 NAT 80% GPH 1333 1067 889 762 667 593 533 485 444 410 381
LPH 5047 4037 3364 2884 2523 2243 2019 1835 1682 1553 1442
GX90-640(A) 640,000 NAT 80% GPH 1551 1241 1034 887 776 690 621 564 517 477 443
LPH 5873 4698 3915 3356 2936 2610 2349 2135 1958 1807 1678
GX90-715(A) 715,000 NAT 80% GPH 1733 1387 1156 991 867 770 693 630 578 533 495
LPH 6561 5249 4374 3749 3280 2916 2624 2386 2187 2019 1875
GX90-500(A) 500,000 LP 80% GPH 1212 970 808 693 606 539 485 441 404 373 346
L.P.
LPH 4588 3670 3059 2622 2294 2039 1835 1668 1529 1412 1311
GX90-600(A) 600,000 LP 80% GPH 1455 1164 970 831 727 647 582 529 485 448 416
L.P.
LPH 5506 4404 3670 3146 2753 2447 2202 2002 1835 1694 1573
GX90-680(A) 680,000 LP 80% GPH 1649 1319 1099 942 824 733 659 599 550 507 471
L.P.
LPH 6240 4992 4160 3565 3120 2773 2496 2269 2080 1920 1783
Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory. Recovery rate shown on the rating plate (80%) Thermal Efficiency in accordance with ANSI Z21.10.3 labeling requirements. (A) indicates available ASME model.
22°C 28°C 33°C 39°C 45°C 50°C 56°C 61°C 67°C 72°C 78°C