Remington BV12199A User Manual

ELECTRIC BLOWER/VAC
®
OWNER’S MANUAL
MODEL: BV12199A
IMPORTANT: Read and understand this manual before assembling or operating this appliance. Improper use of this appliance can cause severe injury or death. Keep this manual for future reference.
118034
REMINGTON® ELECTRIC BLOWER/VAC | iII
table of contents
1 Important Safety Information 1
2 Product Identification 3
3 Blower/Vac Assembly 4
4 Blower/Vac Operation 7
Assembling Blower . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Converting from Blower to Vacuum . . . . . . . . . . . . . . . . . . . . 5
Extension Cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Operating the Blower/Vac . . . . . . . . . . . . . . . . . . . . . . . . 8
5 Blower/Vac Maintenance 11
Cleaning and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . 11
Servicing of Double-Insulated Appliances . . . . . . . . . . . . . . . . . 11
6 Troubleshooting 12
7 Replacement Parts 13
8 Warranty Information 14
118034
iv |
welcome
ank you for purchasing this Remington® Electric Blower/Vac. We are proud to offer this quality product to assist you in keeping your property neat and well-groomed.
is owner’s manual provides complete instructions for safely assembling, operating, and maintaining your Blower/Vac. Read and save these instructions. Refer to this manual each time before using your Blower/Vac.
For easy reference, record the information from the carton and Remington® nameplate label located on the appliance.
Model Number: ________________ Date Purchased: Where Purchased:
If you have a question or problem,
CALL TOLL FREE 1-800-858-8501
or visit www.desatech.com
________________ ________________
118034
REMINGTON® ELECTRIC BLOWER/VAC | 1
1 important safety information
SAFETY WARNINGS
When using an electric appliance, basic precautions should always be followed, including the following:
WARNING: When using blow­er/vac, follow all basic safety precautions to reduce the risk of fire, electric shock, and personal injury.
WARNING: This product con­tains chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm.
WARNING: To Reduce The Risk of Electric Shock – Do not use vacuum on wet surfaces. Do not expose to rain. Store indoors.
BEFORE OPERATING BLOWER/VAC
READ ALL INSTRUCTIONS BEFORE OPERATING THIS BLOWER/VAC.
1. Avoid Dangerous Environments
• This blower/vac is intended for indoor or outdoor use. Do not op­erate blower/vac in rain or in damp or wet locations.
• Do not handle electric plug or blower/vac with wet hands.
• Do not use to vacuum any liquids or wet surfaces. Especially, do not use to vacuum flammable or combus­tible liquids, such as gasoline, or in areas where they may be present.
• Do not vacuum anything that is burning or smoking, such as ciga­rettes, matches, or hot ashes.
• Do not operate blower/vac if it is damaged or not securely and fully assembled.
2. Do not allow blower/vac to be used as a toy. Pay close attention when using blower/vac near children.
3. Do not use blower/vac for any job except that for which it is intended. Use only as described in this manual. Use only attachments included with this blower/vac.
4. Do not use vacuum without dust bag and/or filters in place.
5. Always wear eye protection that meets or exceeds the requirements of ANSI Z87.1.
6. Wear long pants and shoes when operating this blower/vac.
Provide Ground Fault Circuit In-
7. terrupter (GFCI) protection on the circuit or outlet to be used for blower/vac. You may use receptacles with built-in GFCI protection for this safety measure.
WHILE OPERATING BLOWER/VAC
1. Stay alert. Watch what you are doing. Use common sense.
2.
Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
3. Never operate this blower/vac with defective guards or shields, or without safety devices in place.
4. Disconnect from power supply before clearing any blockage.
5. Do not abuse power cord. Never pull or carry blower/vac by power cord. Never yank cord to disconnect from receptacle. To unplug, grasp plug, not the cord. Do not close a door on the cord. Keep power cord from heat, oil, and sharp edges.
6. Use extra care when using blower/vac on stairs.
7. Do not put any object into openings. Do not use with any opening blocked. Keep free of dust, lint, hair, and any thing that may reduce air flow.
8. Disconnect blower/vac properly. Turn off all controls before disconnecting blower/vac from power supply.
9. e impeller rotates for a few seconds after turning blower/vac off. The rotating impeller can cut or injure fingers. Do not remove the bottom inlet cover while the motor is running or when the blower/vac is plugged into a power outlet.
-
118034
2 | Chapter 1: Important Safety Information
MAINTENANCE AND STORAGE OF BLOWER/VAC
1. Maintain blower/vac with care.
• Do not use with damaged cord or plug.
• If blower/vac is not working prop­erly, has been dropped, damaged, left outdoors, or dropped into wa­ter, have it repaired by a qualified service center.
• Keep handles dry, clean, and free from oil and grease.
2. Check damaged parts.
• If a part is damaged, carefully check the damaged part before using the blower/vac. Make sure the part will operate properly and perform its intended function.
• Check for alignment of moving parts, binding of moving parts, breakage of parts, mounting, and any other con dition that may affect its operation.
• A guard or other part that is dam aged should be properly repaired or replaced by a qualified service center unless indicated elsewhere in this manual.
3. Store idle blower/vac indoors. When not in use, store the blower/vac and extension cord indoors in a dry loca­tion. Store blower/vac above the reach of children or in a locked area out of the reach of children.
is manual is your guide to safe and proper operation of the blower/vac.
SAVE THESE
INSTRUCTIONS.
-
-
118034
REMINGTON® ELECTRIC BLOWER/VAC | 3
2 product identification
A. Blower/Vac Housing B. On/Off Switch C. Blower Tube D. Bottom Inlet Cover E. Vacuum Bag Adapter F. Vacuum Bag G. Vacuum Tube Adapter H. Upper Vacuum Tube I. Lower Vacuum Tube J. Extension Cord Retainer K. Inlet Plug
E
F
B
G
K
Figure 2-1: Remington® electric blower/vac
A
C
H
I
D
J
Specifications
BV12199A
Input
Max. Blower Velocity
Max. Blower Air Output
Vacuum Bag Capacity
Net Weight
120V, 12A
200 mph
350 ft3/min.
3
1.6 ft
9 lbs. (4.1 Kg)
118034
4 |
3 blower/vac assembly
Assembling Blower
WARNING: To Reduce The Risk of Personal Injury or Electric Shock – Disconnect from power source before assembling or changing attachments.
Follow the steps below to assemble the blower. IMPORTANT: You must install the blower tube before installing the bottom inlet cover. e bottom inlet cover hooks onto the blower tube. e blower will not run unless the bottom inlet cover is locked into place.
1. Slide the blower tube onto outlet on front of blower/vac housing (see Figure 3-1). Make sure the moulded hook on the blower tube is positioned below the blower.
2. Position front of bottom inlet cover over blower tube hook (see Figure 3-2).
3. Pivot bottom inlet cover to bottom of blower/vac housing. Slightly press locking lever on bottom inlet cover to allow cover to lock into place (see Figures 3-3 and 3-4).
1
Figure 3-1: Sliding blower tube into place
3
Figure 3-2: Attaching bottom inlet cover to blower tube hook
4
Figure 3-3: Pivoting bottom inlet cover to blower/vac housing
2
Figure 3-4: Pressing locking lever
118034
REMINGTON® ELECTRIC BLOWER/VAC | 5
Converting from Blower to Vacuum
WARNING: To Reduce The Risk of Personal Injury or Electric Shock – Disconnect from power source before assembling or changing attachments.
Follow the steps below to convert from blower to vacuum. IMPORTANT: You must install the collection bag/adapter before installing the vacuum tube assembly. e vacuum tube assembly hooks into the collection bag/adapter. e vacuum will not run unless the vacuum tube assembly is locked into place.
1. Press locking lever on bottom inlet cover and remove bottom inlet cover from blower/vac. Remove blower tube from blower/vac.
2. Slide vacuum tube adapter onto outlet on front of blower/vac housing (see Figure 3-5). Make sure the adapter locks into place.
Figure 3-5: Sliding vacuum tube adapter into place
118034
6 |
Chapter 3: Blower/Vac Assembly
Converting from Blower to Vacuum, continued
3. Connect the lower and upper vacuum tubes together (see Figure 3-6). Align the ridge on the bottom tube with the channel on the top tube. Press together until you hear a “snap”.
4. Connect the tubes to the vacuum tube adapter (see Figure 3-7). Align the tab on the top tube with the notch on the vacuum tube adapter. Press together until you hear a “snap”.
5. Position front of vacuum tube adapter assembly over vacuum bag adapter hook (see Figure 3-8).
6. Pivot vacuum tube adapter assembly to bottom of blower/vac housing. Slightly press locking lever on vacu­um tube adapter to allow adapter to lock into place (see Figures 3-9 and 3-10).
Notch
Tab
Figure 3-7: Connecting vacuum tubes to vacuum tube adapter
2
5
Figure 3-9: Pivoting vacuum tube adapter to blower/vac housing
1
Figure 3-6: Conntecting lower and upper vacuum tube together
4
Figure 3-8: Attaching vacuum tube adapter to blower tube hook
3
Figure 3-10: Pressing locking lever
118034
REMINGTON® ELECTRIC BLOWER/VAC | 7
4 blower/vac operation
To reduce the risk of electric shock, this
IMPORTANT: is blower/vac is for house hold use only.
WARNING: Read and under­stand this owner’s manual before operating blower/vac. Make cer­tain you read and understand all Safety Warnings on pages 1 and 2 of this manual. Improper use of this blower/vac can result in severe injury or death from fire, electric shock, or body contact with moving parts.
WARNING: To reduce the risk of electric shock, use only with an extension cord intended for outdoor use, such as SW-A, SOW-A, STW-A, STOW-A, SJW-A, SJOW-A, SJTW-A, or SJTOW-A.
­blower/vac has a polarized plug (one blade is wider than the other) and will require the use of a polarized extension cord. e blower/vac’s plug will fit into a polarized extension cord only one way. If the plug does not fit fully into the extension cord, reverse the plug. If the plug still does not fit, obtain a correct polarized extension cord. A polarized extension cord will require the use of a polarized wall outlet. is plug will fit into the polarized wall outlet only one way. If the plug does not fit fully into the wall outlet, reverse the plug. If the plug still does not fit, contact a qualified electrician to install the proper wall outlet. Do not change the blower/vac plug, extension cord receptacle, or exten sion cord plug in any way.
Inspect cord often. Replace if damaged.
Figure 4-1: Plugging extension cord into inlet plug
-
Extension Cords
Make sure your extension cord is in good condition. Inspect extension cords periodi­cally and replace if damaged. When using an extension cord, be sure to use one heavy enough to carry the current your blower/vac will draw. An undersized extension cord will cause a drop in line voltage resulting in loss of power and overheating.
e table below shows the correct size exten­sion cord to use depending on cord length and nameplate ampere rating. If in doubt, use the next larger gauge cord. e smaller the gauge number, the larger the cord. To reduce the risk of disconnection of blower/vac from the extension cord during operation, use the cord hitch described in this manual.
Cord Length AWG Cord Size
25 feet
50 feet
100 feet
150 feet
16 AWG
16 AWG
14 AWG
12 AWG
Connecting Extension Cord
WARNING: Fully seat the ex­tension cord on the inlet plug of blower/vac. Failure to do so could lead to overheating of blower/ vac. This could cause a fire that results in personal injury to you or others.
e blower/vac has a built-in extension cord retainer. is cord hitch prevents ac cidental disconnection of the power cord during use. e cord hitch is molded into the lower rear of the blower/vac housing.
1. Plug extension cord into the inlet plug of appliance (see Figure 4-1).
2. Create a loop in the extension cord and insert the loop through the cord slot of the blower/vac housing (see Figure 4-2).
3. Pull the loop tight around the molded cord hitch (see Figure 4-3).
Figure 4-2: Inserting extension cord loop through cord slot
-
Figure 4-3: Pull extension cord loop tight around molded cord hitch
118034
8 | Chapter 4: Blower/Vac Operation
Operating the Blower/Vac
e on/off toggle switch has three settings; off, low, and high. e middle switch po­sition, marked “O”, is off. e rear switch position, marked “I”, is low. e forward switch position, marked “II”, is high. See Figure 4-4.
Blower Operation
WARNING: The blower can throw debris, causing injury to those nearby.
• Do not blow nails, bolts, rocks,
or other hard objects.
• Do not operate blower near
bystanders or pets.
• Be careful when blowing de-
bris from stairs, corners, or other tight areas. Objects can be blown back toward operator.
• Wear approved eye protection,
long pants, and shoes while operating this blower/vac.
Figure 4-4: On/Off switch positions
Figure 4-6: On/Off Switch to HI position
Properly assemble the blower/vac for blower operation (see page 4, Assembling Blower). Follow the steps below to operate the blower.
1. Hold blower/vac using the handle on housing (see Figure 4-5).
2. When ready to start the blower, toggle the on/off switch to either the low “ or high “II” setting (see Figure 4-6).
3. To stop the blower, toggle the on/off switch to the off “O” setting.
I
Figure 4-5: Holding blower/vac for blower operation
Figure 4-7: Operating blower
118034
REMINGTON® ELECTRIC BLOWER/VAC | 9
Vacuum Operation
WARNING: The vacuum can throw debris, causing injury to those nearby.
• Do not operate vacuum without
the vacuum bag attached or with the bag zipper opened.
• Do not vacuum nails, glass,
rocks, wire, staples, or other sharp, pointed, or hard objects. These items could be thrown through the cloth bag.
CAUTION: Vacuum only soft items such as leaves and cut grass. Hard items such as sticks, rocks, and acorns will damage the impeller.
CAUTION: Do not force the vacuum tube into a pile of debris. Do not hold the tube upright and force-feed debris into the tube. These actions may clog and dam­age the impeller. If the vacuum vibrates excessively or makes abnormal noises, turn vacuum off, unplug power cord, and check for clogging. Clear any clogged debris from the blower/vac.
CAUTION: Normal vacuum usage causes the vacuum bag to wear and deteriorate. A worn or deteriorated bag allows vacuum to throw debris through the bag, possibly hitting and injuring the operator. Check vacuum bag fre­quently. If it is worn, deteriorated, or damaged, replace with a genu­ine vacuum bag.
Properly assemble the blower/vac for vacuum operation (see page 5, Converting from Blower to Vacuum). Follow the steps below to operate the vacuum.
1. Hang vacuum bag from your shoulder using the attached strap. Hold blow er/vac using the handles on housing and vacuum tube adapter assembly (see Figure 4-7).
2. When ready to start the vacuum, toggle the on/off switch to either the low “I” or high “II” setting (see Figure 4-4).
3. Move end of vacuum tube over soft debris. Vacuum will pick up debris, chop it up, and deposit it into vacuum bag (see Figure 4-8).
4. To stop the vacuum, toggle the on/off switch to the off “O” setting.
Figure 4-7: Holding blower/vac for vacuum operation
-
118034
Figure 4-8: Picking up debris with vacuum
10 |
Chapter 4: Blower/Vac Operation
Emptying the Vacuum Bag
1. Turn vacuum off and unplug power cord.
2. Press locking lever on vacuum tube adapter and remove tube adapter as­sembly from blower/vac (see Figures 4-11 and 4-12).
3. Depress locking button on vacuum bag adapter and remove from blower/ vac housing (see Figure 4-9).
4. Unzip vacuum bag and shake out contents (see Figure 4-10).
5. Zip the vacuum bag closed and reassemble vacuum bag adapter to blower/vac housing.
6. Replace vacuum tube adapter assem­bly.
Removing Clogged Debris from the Impeller
1. Turn vacuum off and unplug power cord.
2. Press locking lever on vacuum tube adapter and remove tube adapter as­sembly from blower/vac (see Figures 4-11 and 4-12).
3. Check the impeller for clogged debris and any signs of damage. Carefully remove debris from impellers (see Figure 4-13).
4. Replace vacuum tube adapter assem­bly.
Figure 4-12: Removing vacuum tube adapter
Figure 4-9: Removing bag/adapter assembly
Figure 4-10: Unzipping and emptying bag
Figure 4-11: Pressing locking lever
Figure 4-13: Removing debris from impellers
118034
REMINGTON® ELECTRIC BLOWER/VAC | 11
5 blower/vac maintenance
Cleaning and Maintenance
WARNING: Disconnect blower/ vac from power supply before cleaning or servicing. Severe injury or death could occur from fire, electrical shock, or rotating impeller.
WARNING: When cleaning blower/vac:
• Do not su bmerse in any
liquids
• Do not use products that con-
tain Ammonia, Chlorine, or abrasives
• Do not use chlorinated cleaning
solvents, Carbon Tetrachloride, Kerosene, or Gasoline.
Use a soft cloth dampened with a mild soap and water mixture to wipe blower/vac housing. Do not spray or pour water directly onto blower/vac.
When not in use, store the blower/vac and extension cord indoors in a dry location.
Figure 5-1: Cleaning blower/vac housing
Servicing of Double-Insulated
Appliances
A double-insulated appliance is marked with one or more of the following: e words “DOUBLE INSULATION” or “DOUBLE INSULATED” or the double insulation symbol (square within a square).
In a double-insulated appliance, two sys tems of insulation are provided instead of grounding. No grounding means is provided on a double-insulated appliance, nor should a means for grounding be added to the appliance. Servicing a double-insu­lated appliance requires extreme care and knowledge of the system, and should be done only by qualified service personnel. Replacement parts for a double-insulated appliance must be identical to the parts they replace.
-
118034
12 |
6 troubleshooting
WARNING: Unplug blower/vac from power source before servicing. Severe
injury or death could occur from fire, electrical shock, or rotating impeller.
Note: For additional help, visit our tech nic al ser vi ce web site at
www.desatech.com.
OBSERVED FAULT POSSIBLE CAUSE REMEDY
Motor does not run when you turn on/off switch low or high
Motor runs, but vacuum will not pick up debris
Blower/vac vibrates excessively and/or makes abnormal noises
1. Bottom inlet cover or vacuum tube adapter not locked into place
2. Extension cord connection is loose
1. Clogged vacuum tube or impeller
2. Vacuum bag full
Clogged vacuum tube or impeller Follow steps under Removing Clogged
1. Check inlet cover or vacuum tube adapter for proper installation (see blower/vac assembly, page 4)
2. Check cord connection at electrical outlet and at rear of blower/vac
1. Follow steps under Removing
Clogged Debris from the Impeller,
page 10
2. Empty vacuum bag (see Emptying
the Vacuum Bag, page 10
Debris from the Impeller, page 10
Technical Service
You may have further questions about assembling, operating, or maintaining this blower/vac. If so, you can visit our Technical Service web site at www.desatech.com or contact our Technical Service Department at 1-800-858-8501 (English only). You may also write to:
DESA Specialty Products™ ATTN: Technical Service Specialty
Products P.O. Box 90004 Bowling Green, KY 42102-9004
When contacting DESA Specialty Prod ucts™, have ready
• Your Name
• Your Address
• Your Phone Number
• Model Number of Product
• Date of Purchase (include copy of receipt for written requests)
-
118034
SOPLADORA/ASPIRADORA ELÉCTRICA REMINGTON® | 13
7 replacement parts
Replacement Parts
Use the part numbers below to order replacement parts for your blower/vac.
Part
Item Description
Blower Tube
1
Bottom Inlet Cover
2
Vacuum Bag with Adapter
3
Upper Vacuum Tube with Adapter
4
Lower Vacuum Tube
5
Number
118063-01
118064-01
118066-01
118734-01
118069-01
1
3
2
4
5
118034
14 |
8 warranty information
REMINGTON® ELECTRIC BLOWER/VAC LIMITED WARRANTY
Always specify model number when contacting the factory. We reserve the right to amend these specifications at any time without notice. e only warranty applicable is our standard
written warranty. We make no other warranty, expressed or implied. DESA Specialty Products™ warrants this Electric Blower/Vac and any parts thereof, to be free from defects in material and
workmanship for two years (90 days for reconditioned unit) from the date of first purchase from an authorized dealer, provided that the product has been properly maintained and operated in accordance with all applicable instructions. is warranty is extended only to the original retail purchaser. e bill of sales or proof of purchase must be presented at the time a claim is made under this warranty.
is warranty does not cover commercial, industrial, or rental usage, nor does it apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accident, lack of proper mainte­nance, tampering, or alteration. Travel, handling, transportation, and incidental costs associated with warranty repairs are not reimbursable under this warranty and are the responsibility of the owner.
To the full extent allowed by the law of the jurisdiction that governs the sale of the product, this express warranty excludes any and all other expressed warranties and limits the duration of any and all implied warranties, including warranties of mer­chantability and fitness for a particular purpose to two years form the date of first purchase, and DESA Specialty Products’™ liability is hereby limited to the purchase price of the product and DESA Specialty Products™ shall not be liable for any other damages whatsoever including indirect, incidental, or consequential damages.
Some states do not allow limitation of how long an implied warranty lasts or an exclusion or limitation of incidental or con­sequential damages, so the above limitation of damages may not apply to you.
is warranty provides the original purchaser with specific rights. For information regarding those rights, please consult the applicable state laws.
P.O. Box 90004 Bowling Green, KY 42102-9004