TECHNICAL SPECIFICATION SHEET
MODEL : Gas 310 ECO Pro 355
Rated Output kW (80/60°c) :
SBEM Seasonal Efficiency %: GCV(¹)
Rated Output kW (50/30°c) :
Min/Max Gas pressure mbar :
Gas Connection size BSP :
Acoustic level dB(A) at 1 metre (ᵌ):
Connection Size Flanged :##
Resistance @ 11C t mbar :
Resistance @ 20C t mbar :
Nom Flow Rate @ 11 C t l/s:
High Limit Set Point C :
Nom Flow Rate @ 20 C t l/s:
Max operating pressure bar :
Min operating pressure bar :
Mass flue gas flow rate kgs/hr :
Air inlet diameter mm I/D :
Residual Fan Duty Pa :
Flue Gas Temperature @ 80/60 °C :
Modulating input V dc :
Start Current amps :
Insulation Class IP :
Run Current amps :
On/Off 0-10v dc
Open Therm
Manual o/ride
Modulating (20 - 100%)
High limit protection
Low water protection
Safety interlocks
Hours run indication
Optional :
Main Options
Contact Sales Dept
for more details
Optimising/Compensators >
Second return >
Gas leak Detection >
Water Pressure Switch >
Air Inlet Filter >
For multiple and single boiler
65mm Flanged 80mm PN16
Option fitted to gas valve
System pressure
Connects to boiler air supply
This is a quick reference specification sheet, full details can be found in the Gas 310 Eco Pro installation and Service
guide via www.remeha.co.uk/documents
General Details
Fully condensing floor standing boiler supplied c/w electronic temperature and safety controls. Sectional cast aluminium
heat exchanger. Powder coated, enamel steel casing. Ultra low NOx, on/off, or fully modulating (20-100%), pre - mix
burner, gas/air ratio control for maximum efficiency and minimum emissions. Boiler fitted with casters for ease of
positioning within plant room. Intelligent "abc" boiler control system c/w numerical display providing operating and service
parameters. Manufactured to ISO 9001. CE approved and supplied pre-assembled, easy to dismantle for ease of
installation. NOx levels according to EN483 and EN 15420 (EN297 A3).
(¹) In accordance with the Non Domestic Building Services Compliance Guide 2013 Edition – for use in England
(²) At 30°c ΔT = Boiler temp – Ambient temp (without heat exchanger insulation kit)
(ᵌ) For room sealed operation
# For a continuous supply of heat the boiler requires a minimum flow of 30% of the design flow rate
## Flow 80mm Return 65mm both Flanged NW 80 DIN 2576 – (PN16)
Ours is a policy of continuous development, we therefore reserve the right to alter specifications without prior notification.
Remeha Commercial accept no liability for any loss or damage rising from any errors or omissions that may be