Remcor Incorporated
500 Regency Drive
Glendale Heights, IL 60139
Telephone (708) 980-6900
Facsimile (708) 980-8511
FOR
31204 CRACKER MOTOR CONVERSION KIT
This kit allows replacement of the shaded pole cracker motor (2 wires) by an alternate capacitor type motor (3
wires). Performance of both motors is identical.
Note: on units which contain two cracker motors, repeat the installation steps for each motor. See atÂtached installation drawing.
PROCEDURE
1. Disconnect all power from unit.
2. Remove old motor. Note wire connection in electric box.
3. Install new motor. Be sure cracker bar is properly seated on shaft and pivot pin.
4. Locate clear area on bulkhead panel for capacitor mounting, as shown. Mark and drill holes for clamp, and
mount capacitor using sheet metal screws provided.
5. Connect motor and capacitor as shown. Install rubber cap on capacitor. Connect leads to original location
in electric box.
6. Energize icemaker and confirm proper operation of cracker motor. Check that cracker bar does not hit
evaporator plate. Installation is now complete.
Order future replacement motors under the original part number (30487). If shaded pole motor is provided in the
future, connect as originally and disregard the capacitor.
BLACK
RUBBER
CAPS
GREEN
MOTOR
GROUND
WHITE
CONNECT TO ORIGINAL
MOTOR CONNECTIONS.
CUT OFF TERMINALS IF
REQUIRED
NEUTRAL
MARKED
TERMINAL
February 1997
Revision C
CAPACITOR 4 MFD, 370
VAC REMCOR P/N 30765
FIGURE 1. CAP ACITOR CRACKER MOTOR INSTALLATION
1
90663