Remcor 31204 Installation Manual

Remcor Incorporated 500 Regency Drive Glendale Heights, IL 60139 Telephone (708) 980-6900 Facsimile (708) 980-8511
FOR
31204 CRACKER MOTOR CONVERSION KIT
This kit allows replacement of the shaded pole cracker motor (2 wires) by an alternate capacitor type motor (3 wires). Performance of both motors is identical.
Note: on units which contain two cracker motors, repeat the installation steps for each motor. See at­tached installation drawing.
PROCEDURE
1. Disconnect all power from unit.
2. Remove old motor. Note wire connection in electric box.
3. Install new motor. Be sure cracker bar is properly seated on shaft and pivot pin.
4. Locate clear area on bulkhead panel for capacitor mounting, as shown. Mark and drill holes for clamp, and mount capacitor using sheet metal screws provided.
5. Connect motor and capacitor as shown. Install rubber cap on capacitor. Connect leads to original location in electric box.
6. Energize icemaker and confirm proper operation of cracker motor. Check that cracker bar does not hit evaporator plate. Installation is now complete.
Order future replacement motors under the original part number (30487). If shaded pole motor is provided in the future, connect as originally and disregard the capacitor.
BLACK
RUBBER CAPS
GREEN
MOTOR
GROUND
WHITE
CONNECT TO ORIGINAL MOTOR CONNECTIONS. CUT OFF TERMINALS IF REQUIRED
NEUTRAL
MARKED TERMINAL
February 1997
Revision C
CAPACITOR 4 MFD, 370 VAC REMCOR P/N 30765
FIGURE 1. CAP ACITOR CRACKER MOTOR INSTALLATION
1
90663