REL QUAKE Owners manual

4.6 (5)
Operating Instructions
for the
Q
Range
of
SUB-BASS SYSTEMS
REL Acoustics Limited
North Road, Bridgend industrial Estate
United Kingdom
Telephone: +44 (0)1 656 768 777
Fax: +44 (0) 1 656 766 093
Web: www.REL.net
First Printed March 12th 2003
REL Acoustics ‘Q’ range User manual
2
REL Acoustics ‘Q’ range User manual
Contents
CONTENTS.................................................................................................................................................................3
IMPORTANT SAFEGUARDS................................................................................................................................4
WARNING...................................................................................................................................................................4
WELCOME.................................................................................................................................................................5
WORLD WIDE WARRANTY.................................................................................................................................5
SERVICE AFTER WARRANTY ........................................................................................................................... 5
DESIGN SAFETY......................................................................................................................................................6
IMPORTANT........................................................................................................................................................... 6
INTRODUCTION TO ‘Q’ RANGE SUB BASS SYSTEMS...............................................................................7
CONTROLS AND CONNECTIONS - QUAKE...............................................................................................8
CONTROLS AND CONNECTIONS - Q108 US MARKET ONLY..............................................................9
CONTROLS AND CONNECTIONS - Q150E................................................................................................10
CONTROLS AND CONNECTIONS- Q200E, Q201E, Q400E .......................................................................11
CONNECTING UP..................................................................................................................................................12
TO CONNECT TO THE POWER AMPLIFIER USING THE UNBALANCED NEUTRIK HIGH LEVEL INPUT.................13
TO CONNECT TO THE AMPLIFIER/PROCESSOR USING THE PHONO TO PHONO LOW LEVEL INTERCONNECT..........14
MODE SELECTOR.................................................................................................................................................15
Q108 CONTROLS....................................................................................................................................................15
REL SET-UP MADE SIMPLE..............................................................................................................................16
REL SET-UP MADE SIMPLER...........................................................................................................................19
RUNNING IN............................................................................................................................................................20
CARE AND POLISHING.......................................................................................................................................20
TECHNICAL.............................................................................................................................................................21
OVERLOAD PROTECTION.................................................................................................................................21
POWER SAVING EFFICIENCY..........................................................................................................................22
SPECIFICATIONS..................................................................................................................................................23
SPECIFICATIONS (CONT.).................................................................................................................................24
3
REL Acoustics ‘Q’ range User manual
IMPORTANT SAFEGUARDS
1. Read all of these instructions.
2. Save these instructions for future use.
3. Unplug from the wall socket before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.
4. Do not use near water.
5. Do not place on a stand or table, it may fall causing injury to a child or adult, and damage to the unit.
6. The unit should only be operated from the power source indicated on the panel of the amplifier.
7. Only use the power cord supplied.
8. Do not allow anything to rest on the power cord. Position the power cord such that it can not be walked on.
9. For added protection during a lightening storm, or when not in use for long periods of time, unplug it from the wall socket.
10. Never spill any kind of liquid on the unit.
11. Do not attempt to service the unit yourself, as removing the amplifier may expose you to dangerous voltages. Refer all servicing to your dealer.
12. Unplug the unit from the wall socket and refer servicing to your dealer under the following conditions:
a. When the power cord or plug is damaged. b. If liquid has been spilled onto the unit. c. If the unit does not operate properly by following the operating instructions. d. If the unit has been dropped and damaged. e. When the unit exhibits a drastic change in performance.
WARNING
This item is heavy. To avoid risk of injury, take care when handling.
4
REL Acoustics ‘Q’ range User manual
WELCOME
Thank you for buying a REL “Q” range Sub-Bass system. Our “Q” range is carefully hand built using the finest materials available and is designed for maximum performance. This manual contains important safety information as well as helpful advice and should be carefully studied before connecting up.
WORLD WIDE WARRANTY
In addition to any local Warranty, REL offer a 3-year conditional Worldwide Warranty to the end user. It is done in collaboration with our Distributors.
The conditions of this Warranty are:
1. That REL receive the necessary registration details from the end user.
2. That these details are received within six weeks of purchase.
3. That the product is not exported from the country of purchase for at least eight weeks after
purchase.
4. That any claim is accompanied by the necessary proof of purchase.
5. That it shall be for a term of 3 years from the date of purchase.
6. That the product has not been abused or modified in any way.
7. That it was purchased originally from a REL authorised dealer.
This Warranty is offered in good faith and is in addition to any statuary rights or existing Warranty that may be available to the end user.
Should your REL Sub Bass Unit give you a problem, please contact your dealer who will be able to make whatever arrangements are necessary to correct it.
SERVICE AFTER WARRANTY
Please contact your dealer in the first instance before returning any product directly to us. Should the unit need to be returned for any reason, all carriage costs will be payable by the customer. Losses or damage caused during transit are the customer's risk.
5
REL Acoustics ‘Q’ range User manual
DESIGN SAFETY
This apparatus is designed to Class II specification and is double insulated,
therefore it does not require to be earthed.
This apparatus is supplied with a fitted mains plug. For UK operation a 5 Amp fuse is fitted in the plug. Should the fuse need to be replaced use a similar rated fuse approved to ASTA or BSI 362. Do not use without the fuse cover in place. Replacement fuse covers are available from your dealer.
If for any reason the plug is cut off it must NOT be re used. Please dispose of any such plug safely. There is a danger of electric shock if the cut off plug is inserted into a mains socket.
IMPORTANT
The wires in the mains lead are coloured in accordance with the following code:
Green and Yellow - Earth Blue - Neutral Brown - Live
As the colours of the wires in the mains lead may not correspond with the markings identifying the terminals in the replacement mains plug, proceed as follows:
- The wire coloured Green and Yellow must be connected to the terminal marked with the letter "E" or with the earth symbol
- The wire coloured Blue must be connected to the terminal marked with the letter "N"
- The wire coloured Brown must be connected to the terminal marked with the letter “L"
This product is CE marked and has been tested to ensure it satisfies all relevant standards.
It satisfies all relevant standards for Conducted Emissions, Radiated Emissions, Susceptibility and Immunity.
It also complies with the requirements relating to class II construction detailed in clauses 9 & 10 of BS EN 60065 1994
It also satisfies all relevant safety tests for consumer use provided it is used within the guidelines of this manual.
6
REL Acoustics ‘Q’ range User manual
Main Features of REL Quake, Q108 (US ONLY), Q150E, Q200E, Q201E and Q400E
1. High level input and low level input. Also PC input on Quake and Q108
2. Separate volume controls for high level and low level inputs
3. Variable filter roll off control
4. Mode switch to control phase and low level filter bypass (Not on Q108)
5. All components of matching superior quality to achieve both long life and long term consistency of sound quality
6. Superior wood veneered finishes available for Quake and Q201E
7. Set-Safe® circuitry ensuring ultimate protection if overloaded.
INTRODUCTION TO ‘Q’ RANGE SUB BASS SYSTEMS
Many or most loudspeakers designed to reproduce low bass are specifically designed to emphasize the mid bass. This is the range from 30 to 70 Hertz. We at REL believe this is wrong. All of our designs are true sub bass systems, meaning they are designed to reproduce those very low frequencies that are felt rather than heard. This is because we believe that music is full range, as are sound effects on movies, and we intend our products to reproduce all of these sounds, not a narrow band.
The “Q” range models are equipped to allow you to take full advantage of AC3, Dolby Digital, DTS, MPEG 2 and any other digital sound format that includes a dedicated Low Frequency Effects (LFE) channel.
The dedicated LFE input meets the tough specification laid down for digital 3/2.1 channels, usually known as 5.1. The output is nominally flat from 25Hz - 120hz. It has a dedicated input level control which enables users to set the LFE level independently of the processor. This is important because not all processors offer control over this significant parameter. The LFE channel is typically recorded at 10db higher levels than the other channels.
The “Q” range also has standard speaker level inputs with their own input level control. Uniquely, both the speaker level and the LFE input can be used simultaneously. This means you can set it up for an audiophile sound with your CD’s or other stereo signals and instantly revert to using the Sub­Bass System as the dedicated LFE component when watching movies. This is a feature of real benefit if you wish to play music in stereo mode in the purist audiophile way and in full 5.1 digital mode. True flexibility!
On two models there is a ‘Slam’ and ‘Depth’ selector, (Q150E and QUAKE). 'Slam' mode allows you to choose a higher output level at 40Hz - 150Hz at the expense of maximum bass extension. This is an excellent ‘party’ mode where subtlety and ultimate fidelity is secondary.
Alternatively the standard ‘Depth’ mode 20Hz - 100Hz provides maximum bass extension and is strongly recommended where the highest possible fidelity is demanded. This is ideal for people in pursuit of the absolutely highest fidelity.
See the specification table on pages 18 and 19 for features of the various models.
7
REL Acoustics ‘Q’ range User manual
MAX
MIN
LO LEVEL
MAX
MIN
106HZ
26HZ
HI LEVEL
ROLLOFF
POWER
41HZ1234
MODE
SLAM
DEPTH
CONTOUR
HI LEVEL
LFE
PC
CE
QUAKE
SOURCE1234
LINE
LFE
LINE
LFE
PHASE00
FUSE 2 A/T
~ 220-240 VAC 50-60
100 WATT MOSFET
SUB-BASS SPEAKER SYSTEM
PROTECTED BY
R
REL ACOUSTICS
LTD NORTH ROAD BRIDGEND CF31 3TP UNITED KINGDOM
http://REL.net
FAX: +44 (0) 1656 766093
CONTROLS AND CONNECTIONS - QUAKE
1 2 3 4 5
6
7
8
MODE
180 180
9
1 Slam/Depth switch. Changes the characteristics of the filter/roll off. Depth mode 20 – 100 Hz Slam mode bass emphasised 50 – 150 Hz. ONLY FITTED TO QUAKE AND Q150E
2 Roll off control. Adjust to set the upper roll off frequency of the Sub Bass System. 3 MODE SWITCH. Used to set phase* and to bypass crossover for Low Level input**.
Position 1 / Line: 0 degrees phase, crossover engaged low level input Position 2 / LFE: 0 degrees phase, crossover bypassed for low level input Position 3 / Line: 180 degrees phase, crossover engaged for low level input Position 4 / LFE: 180 degrees phase, crossover bypassed for low level input
*PHASE SELECTION AFFECTS BOTH HI AND LO LEVEL INPUTS
**Crossover is always engaged for Hi level input regardless of mode switch position.
4 LO LEVEL input volume control. Adjust for output level when using LO LEVEL phono input
or balanced line level input XLR socket.
5 HI LEVEL input volume control. Adjust for output level when using HI INPUT Neutrik socket or BAL HI INPUT Neutrik socket.
6 PC input 3.5mm jack socket. Used to connect the Sub Bass System to a computer.
7. LFE input phono socket. Used to connect the Sub Bass System to the LFE/Sub output of a
5.1 channel amplifier or processor.
8. HI LEVEL input Neutrik Speakon socket. Used to connect the Sub Bass System to the main
front speaker terminals on the amplifier.
9 IEC Mains input socket.
8
Loading...
+ 17 hidden pages