These gas appliances have been tested
in accordance with AS4553, NZS 5262
and have been certied by the Australian
Gas Association for installation and operation as described in these Installation
and Operating Instructions.
Your unit should be serviced annually by an authorised service person.
STYLE MODEL
See ThruPG121-NG1 PG121-LPG1
Left CornerPG121LC-NG1 PG121LC-LPG1
Right Corner PG121RC-NG1 PG121RC-LPG1
PierPG131-NG1 PG131-LPG1
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional information consult an authorized installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorized installer, service agency or
the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electri-
cal switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas supplier's instructions.
If you cannot reach your
gas supplier, call the re
department.
918-648d
08/04/15
Page 2
To the New Owner:
Congratulations!
You are the owner of a state-of-the-art Gas Fireplace by REGENCY. The PG121-1 / PG121LC-1 /
PG121RC-1 / PG131-1 has been designed to provide you with all the warmth and charm of a wood
replace at the ick of a switch. The model PG121-1 / PG121LC-1 / PG121RC-1 / PG131-1 has
been approved by the Australian Gas Association for both safety and efciency. As it also bears
our own mark, it promises to provide you with economy, comfort and security for many trouble free
years to follow. Please take a moment now to acquaint yourself with these instructions and the
many features of your Regency Fireplace.
IMPORTANT:
If the unit is to be installed into a bathroom, optional Neo ceramic glass Part# 360-946 (Front) or
Part# 360-948 (Side) must be purchased and installed in place of the tempered glass supplied
with the unit.
2
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Page 3
TABLE OF CONTENTS
DATA BADGE
Data Badge................................................................. 4
INSTALLATION
Important Message ..................................................... 5
Before You Start ......................................................... 5
General Safety Information......................................... 5
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace3
Page 4
SAFETY LABEL
This is a copy of the label that accompanies each
PG121-1 / PG121LC-1 / PG121RC-1 / PG131-1
Zero Clearance Room Sealed Gas Fireplace.
We have printed a copy of the contents here
for your review. The safety label is located on
the front inside base of the unit, visible when
the bottom louver is open.
NOTE: Regency units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
4
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Page 5
INSTALLATION
IMPORTANT:
SAVE THESE
INSTRUCTIONS
The Regency PG121/PG121LC/PG121RC/
PG131-NG1 or PG121/PG121LC/PG121RC/
PG131-LPG1 Room Sealed Gas Fireplace must
be installed in accordance AG601 and NZS 5261
and with these instructions. Carefully read all
the instructions in this manual rst. Consult the
"authority having jurisdiction" to determine the
need for a permit prior to starting the installation.
It is the responsibility of the installer to ensure this
replace is installed in compliance with manufacturer's instructions and all applicable codes.
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are
required to make you aware of the following:
INSTALLATION AND REPAIR SHOULD
BE DONE BY A AUTHORIZED SERVICE
PERSON. THE APPLIANCE SHOULD
BE INSPECTED BEFORE USE AND AT
LEAST ANNUALLY BY A AUTHORIZED
SERVICE PERSON. MORE FREQUENT
CLEANING MAY BE REQUIRED DUE
TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC.
IT IS IMPERATIVE THAT CONTROL
COMPARTMENTS, BURNERS AND
CIRCULATING AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED
OUT OF TRAFFIC AND AWAY FROM
FURNITURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE
A SERIOUS HOUSE FIRE.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.
CHILDREN AND ADULTS SHOULD
BE ALERTED TO THE HAZARDS OF
HIGH SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS,
AND SHOULD STAY AWAY TO AVOID
BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.
GENERAL SAFETY
INFORMATION
1) The appliance shall be installed in accordance with the manufacturer's installation
instructions, local gas tting regulations,
municipal building codes, water supply
regulations, electrical wiring regulations,
with AS5601-2004 (AGA gas installation
code) NZS 5261 (New Zealand)
2) See general construction and assembly
instructions. The appliance and ue should
be enclosed.
3) This appliance must be connected to the
specied ue and termination cap to the
outside of the building envelope. Never ue
to another room or inside a building. Make
sure that the ue is tted as per Flueing
instructions.
4) Inspect the ueing system annually for
blockage and any signs of deterioration.
5) Flueing terminals shall not be recessed into
a wall or siding.
6) Any safety glass removed for servicing must
be replaced prior to operating the appliance.
7) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
replace.
8) Wear gloves and safety glasses for protection while doing required maintenance.
9) Be aware of electrical wiring locations in
walls and ceilings when cutting holes for
termination.
10) Under no circumstances should this appliance be modied. Parts that have to be
removed for servicing should be replaced
prior to operating this appliance.
11) Installation and any repairs to this appliance
should be done by a authorized service
person. A authorized service person should
be called to inspect this appliance annually.
Make it a practice to have all of your gas
appliances checked annually.
12) Do not slam shut or strike the glass door.
13) Under no circumstances should any solid
fuels (wood, paper, cardboard, coal, etc.)
be used in this appliance.
14) The appliance area must be kept clear and
free of combustible materials, (gases and
other ammable vapours and liquids).
Emissions from burning wood or gas could
contain chemicals known to the State of California to cause cancer, birth defects or other
reproductive harm.
INSTALLATION
CHECKLIST
NOTE:
Not intended for
replace insert.
These units are
non-load bearing.
1) Locate appliance;
a) Room location
b) Clearances to Combustibles
c) Mantle Clearances
d) Framing & Finishing Requirements
e) Flueing Requirements
2) Assemble Top Standoffs. (NOTE: must be
done before installing unit into replace.)
3) Install ue.
4) Make gas connections. Test the pilot. Must
be as per diagram in "Pilot Adjustment"
section.
5) Install log set.
6) Install Glass Door, Louvers or Grills , and
Finishing Trim.
7) Final check.
Before leaving this unit with the customer,
the installer must ensure that the appliance is
ring correctly and operation fully explained
to customer.
This includes:
1) Clocking the appliance to ensure the correct
ring rate (rate noted on label 40,000 Btu/h
NG, and 39,000 Btu/h LPG) after burning
appliance for 15 minutes.
2) If required, adjusting the primary air to
ensure that the ame does not carbon.
First allow the unit to burn for 15-20 min.
to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace5
Page 6
INSTALLATION
SPECIFICATIONS
PG121-1 - See Thru
Note: These units are
non-load bearing.
PG131-1 - Pier
6
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Page 7
PG121LC-1 - Left Corner Unit
INSTALLATION
Note: These units are
non-load bearing.
PG121RC-1 - Right Corner Unit
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace7
Page 8
INSTALLATION
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your stove,
ensure that the clearances are met as
outlined in the "Clearances" section.
2) Provide adequate clearances for servicing.
3) The appliance must be installed on a at,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the oor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed
on carpeting, combustible linoleum tile or
other combustible material other than wood
ooring, the appliance must be installed on
a metal or wood panel extending the full
width and depth of the appliance.
4) The Room Sealed Gas Fireplace can be
installed as follows:
Model # Position
A) PG121-1: See Thru
B) PG131-1: Pier
C) PG121LC-1: Left Corner
D) PG121RC-1: Right Corner
A) PG121-1 - See Thru
B) PG131-1 - Pier
5) This appliance is Listed for bedroom installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The PG121-1 / PG121LC-1 / PG121RC-1
/ PG131-1 Room Sealed Gas Fireplace is
approved for alcove installations, which
meet the clearances listed on this page.
7) We recommend that you plan your installation on paper using exact measurements
for clearances and oor protection before
actually installing this appliance. Have a
authorized inspector, dealer, or installer
review your plans before installation.
Note: For Exterior Flue Termination
Locations see"Exterior Flue Termina-
tion" section.
.
C) PG121LC-1 - Left Corner
8
D) PG121RC-1 - Right Corner
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Page 9
INSTALLATION
CLEARANCES
The clearances listed below are Minimum distances unless otherwise stated (refer to diagrams in "Locating Your Gas Fireplace" section):
Clearance to Combustibles from:
Back 0" (0mm)
Side 0" (0mm)
Floor 0" (0mm)
CAUTION REQUIREMENTS: The top, back and sides of the replace are dened by
standoffs. The metal ends of the standoffs may NOT be recessed into combustible
construction.
Determine the total thickness of the nished oor (eg. tile, carpet, slate) to allow the
nished surface to be ush with the base of the unit.
Ceiling Height from Floor 72" (1828mm)
Mantel Height from Base of Unit:
39" min. (991mm)
Horizontal Flue Clearances:
Top 2-1/2" (64mm)
Side 1-1/2" (38mm) Bottom 1-1/2" (38mm)
Fire hazard is an extreme risk
if these clearances (air space)
to combustible materials are
not adhered to. It is of greatest
importance that this replace
and ue system be installed
only in accordance with these
WARNING:
instructions.
Vertical Flue Clearances 1-1/4" (32mm)
COMBUSTIBLE MANTELS
Due to the extreme heat this replace emits, the mantel clearances
are critical. Combustible mantel clearances from top of unit are shown
in Diagram to the right.
Note: A non-combustible mantel may be installed at a lower
height if the framing is made of metal studs covered with
a non-combustible board.
This drawing is to scale at 1:6 (one inch = 6 inches)
Mantel can be installed anywhere in shaded area or higher using this
scale.
Caution: Ensure the paint that is used on the mantel and the
facing is "heat resistant" or the paint may discolour.
* If the 3" (76mm) metal extension trim is removed it must be replaced
with a 8" (203mm) non-combustible material.
Mantel Clearances
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace9
Page 10
INSTALLATION
FRAMING AND FINISHING
1) For ease of installation, frame your replace after it is positioned and
the ue system is installed. Remember to install the top standoffs.
Use 2x4's and frame to local building codes.
CAUTION: Verify your replace dimensions, framing methods and
nished wall facing details before framing. Determine the total thick-
ness of facing material - drywall plus ceramic tiles, slate, etc. Allow
the nish surface to be ush with the front or side of the unit. Total
facing thickness can vary from 1/2" (13mm) to 1-1/4" (32mm) thick.
2) When locating your appliance on an exterior wall or in a chase, apply
a vapour barrier and drywall, as per local building codes. DO NOT
INSULATE THE FIREPLACE ITSELF.
CAUTION: The unit does not have to be completely enclosed in a
chase. The clearance on top of the unit is 0" to the standoffs so
combustible building materials can be laid directly on top of the
standoffs. You must maintain clearance from the ue to combustible
materials for both rigid and ex.
PG121-1 - See Thru
Framing Dimensions
PG121 (See Thru) PG131 (Pier) PG121LC / PG121RC
(Corner Unit)
A 25"(635mm) 25"(635mm) 26-13/13"(660mm)
minus two times minus two times minus two times
the nishing the nishing the nishing
material thickness* material thickness* material thickness*
B 42-1/2"(1080mm) 42-1/2"(1080mm) 42-1/2"(1080mm)
C 46-3/4"(1187mm) 45" (1143mm) 45"(1143mm)
minus one time minus one time
the nishing the nishing
material thickness* material thickness*
* Finish material thickness includes: drywall, ceramic tile, slate, etc.
PG121LC-1 - Corner Unit
PG131-1 - Pier
Note: These units are
non-load bearing.
10
PG121RC-1 - Corner Unit
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Page 11
INSTALLATION
FACING & FINISHING REQUIREMENTS
This replace is supplied with a 3" metal extension trim above the replace. The extension trim may be replaced if the framing is faced with a noncombustible material placed ush with the front and side face of the unit and extending from the top of the unit. (ie. tile, slate, etc.)
UNIT ASSEMBLY
PRIOR TO
INSTALLATION
The 4 Top Standoffs must be correctly positioned and attached to the top before unit is slipped
into position.
Top Standoff Assembly
The top standoffs are shipped in a at position and must be folded into shape and attached.
1) Remove the standoffs from the replace
top.
2) Take each standoff and bend into the correct shape. Bend up at the bend lines until
the screw holes in the standoff and the
pre-punched screw holes on the replace
top line up.
3) Attach the standoff securely to the top with
4 screws per standoff (on opposite corners).
FLUEING
INTRODUCTION
The PG121-1 / PG121LC-1 / PG121RC-1 /
PG131-1 uses the "balanced ue" technology
Co Axial system. The inner liner ue products of
combustion to the outside while the outer liner
draws outside combustion air into the combustion chamber thereby eliminating the need to
use heated room air for combustion and losing
warm room air up the chimney.
Note: These uepipesmust notbecon-
nectedtoanyotherappliance.
The gas appliance and ue system must be
ueed directly to the outside of the building,
and never be attached to a chimney serving a
separate solid fuel or gas burning appliance.
Each direct ue gas appliance must use it's own
separate ue system. Common ue systems
are prohibited.
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace11
Page 12
INSTALLATION
EXTERIOR FLUE TERMINATION LOCATIONS
according to AS5601-2004 (AGA gas installation code) or NZS 5261 (New Zealand)
Minimum clearances required for balanced ue terminals or
the ue terminals of outdoor appliances
Minimum
Clearance (mm)
a Below eaves, balconies or other projections:
- Appliances up to 50 MJ/h input 300
- Appliances over 50 MJ/h input 500
b From the ground or above a balcony 300
c From a return wall or external corner 500
d From a gas meter (M) 1000
e From an electricity meter or fuse box (P) 500
f From a drain or soil pipe 150
g Horizontal from any building structure (unless appliance is approved
for closer installation) or obstruction facing a terminal 500
h From any other ue terminal, cowl or combustion air intake 500
j Horizontally from an openable window, door, or non-mechanical air inlet, or
any other opening into a building, with the exception of sub-oor ventilation
(see also Note (I)):
- Appliances up to 150 MJ/h input 500
- Appliances over 150 MJ/h input 1500
k Vertically below an openable window, door, or non-mechanical air inlet,
or any other opening into a building, with the exception of sub-oor ventilation
(see also Note (I)): see table below
Clearance 'k' in mm
Space Heaters All Other Appliances
Up to 50 MJ/h Up to 50 MJ/h input Over 50 MJ/h input Over 150 MJ/h input
input to 150 MJ/h input
150 500 1000 1500
NOTES:
(I) For mechanical air inlets, including spa blowers, the clearance 'j' and 'k' shall be 1500 mm in all cases.
(II) All distances shall be measured vertically or horizontally along the wall to a point in line with the nearest par to of the terminal.
(III) Prohibited area below electricity meter or fuse box extends to ground level.
(IV) A ue terminal of this type shall not be located under a roofed area unless the roofed area is fully open on at least two sides and a
free ow of air at the appliance is achieved.
12
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
These ueing systems, in combination with the PG121-1 / PG121LC-1 / PG121RC-1 / PG131-1 Direct Vent Gas Fireplace, have been tested and
listed as a direct ue heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Flue Terminal
Locations diagram.
Regency Direct Vent (Flex) System Termination Kit (Part# 946-513) includes all the parts needed to install the PG121-1 / PG121LC-1 /
PG121RC-1 / PG131-1 with a maximum run of 2 feet.
1) 6-7/8" dia. exible liner (2 ft. length)
2) 4" dia. exible liner (2 ft. length)
3) spring spacers (3)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" drill point, stainless steel (4)
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency may be used for Flex installations.
3) Regency Direct Vent System (Flex) is only approved for horizontal terminations.
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace13
Page 14
INSTALLATION
SIMPSON DURA-VENT FLUEING
HorizontalorVerticalTerminations
The Simpson Dura-Vent Direct Vent System offers a complete line of component parts for installation of both horizontal and vertical installations.
Many items are offered in decorative black, as well as galvanized nish. We recommend using the galvanized nish for installation with the PG121-1
/ PG121LC-1 / PG121RC-1 / PG131-1.
The minimum components required for a
basic horizontal termination are:
1 Simpson Duravent Adaptor
1 Horizontal Termination Cap
1 45
1 Flue Adaptor
1 Wall Thimble
1 Length of pipe to suit wall
thickness (see chart)
Wall thickness is measured from the back
standoffs to the inside mounting surface
of termination cap. For siding other than
o
Elbow
Flat Wall Installation
vinyl furring strips may be
used, instead of the vinyl sid-
ing standoff, to create a level
surface to mount the vent terminal. The Terminal must not be
recessed into siding. Measure
the wall thickness including
furring strips.
If a Vinyl Siding Standoff is
required (it must be used with
vinyl siding), measure to outside
surface of wall without siding
and add 2 inches.
991 High Wind Termination Cap (Vertical)
980 Vertical Termination Cap
984 Horizontal Square Termination Cap
985 Horiz. Square High Wind Termination Cap
982 Snorkel - 14" Rise Termination Cap
981 Snorkel - 36" Rise Termination Cap
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
A) 1' (305mm) Minimum 3' (914mm) Maximum
B) 2' (610mm) Minimum 6' (1.86m) Maximum
C) 3' (914mm) Minimum 9' (2.7m) Maximum
D) 4' (1.22m) Minimum 12' (3.6m) Maximum
E) 5' (1.5m) Minimum 15' (4.5m) Maximum
F) 6' (1.86m) Minimum 17' (5.1m) Maximum
With the above options, maximum total pipe length if 37 feet with
minimum of 6 feet total vertical and maximum 17 feet total horizontal.
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace15
Page 16
INSTALLATION
Horizontal Flueing with Two (2) 90o Elbows
Option V H + H1
A) 1' (305mm) Minimum 2' (610mm) Maximum
B) 2' (610mm) Minimum 5' (1.5m) Maximum
C) 3' (914mm) Minimum 8' (2.4m) Maximum
D) 4' (1.22m) Minimum 11' (3.35m) Maximum
E) 5' (1.5m) Minimum 14' (4.27m) Maximum
F) 6' (1.86m) Minimum 15' (4.5m) Maximum
With the above options, maximum total pipe length if 37 feet with
minimum of 6 feet total vertical and maximum 15 feet total horizontal.
A) 2' (610mm) Minimum 3' (914mm) Maximum
B) 3' (914mm) Minimum 6' (1.86m) Maximum
C) 4' (1.22m) Minimum 9' (2.7m) Maximum
D) 5' (1.5m) Minimum 12' (3.6m) Maximum
With the above options, maximum total pipe length if 37 feet with
minimum of 5 feet total vertical and maximum 12 feet total horizontal.
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Page 17
INSTALLATION
FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS
SIMPSONDURA-VENTDIRECTVENTGSSYSTEM
• Flue must be supported at offsets
• Maintain clearances to combustibles.
• Firestops are required at each oor level and whenever passing through a wall.
• Must use optional ue adapter when using Simpson Dura-Vent pipe (Part# 510-994).
The PG121-1 / PG121LC-1 / PG121RC-1 / PG131-1 is approved for a maximum 35 ft. (10.7m) straight vertical, with Simpson Dura-Vent Direct
Vent GS ue systems for LPG and NG.
Straight Up Vertical Flueing
Vertical Flueing with One (1) 90o Elbow
Option V H
A) 1' (305mm) Minimum 2' (610mm) Maximum
B) 2' (610mm) Minimum 4' (1.22m) Maximum
C) 3' (914mm) Minimum 6' (1.86m) Maximum
D) 4' (1.22m) Minimum 8' (2.4m) Maximum
With the above options, maximum total pipe length if 37 feet with
minimum of 4 feet total vertical and maximum 8 feet total horizontal.
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace17
Diagram 8
Page 18
INSTALLATION
Vertical Flueing with Two (2) 90o Elbows
Option V H
A) 1' (305mm) Minimum 4' (1.22m) Maximum
B) 2' (610mm) Minimum 6' (1.86m) Maximum
C) 3' (914mm) Minimum 9' (2.7m) Maximum
D) 4' (1.22m) Minimum 12' (3.6m) Maximum
E) 5' (1.5m) Minimum 15' (4.5m) Maximum
F) 6' (1.86m) Minimum 17' (5.1m) Maximum
With the above options, maximum total pipe length if 37 feet with
minimum of 6 feet total vertical and maximum 17 feet total horizontal.
A) 1' (305mm) Minimum 2' (610mm) Maximum
B) 2' (610mm) Minimum 4' (1.22m) Maximum
C) 3' (914mm) Minimum 6' (1.86m) Maximum
D) 4' (1.22m) Minimum 8' (2.4m) Maximum
Vertical Flueing with Two (2) 90o Elbows
With the above options, maximum total pipe length if 37 feet with
minimum of 4 feet total vertical and maximum 8 feet total horizontal.
Pleasenoteminimum1footbetween90
o
elbowsisrequired.
Diagram 9
Diagram 10
Vertical Flueing with Three (3) 90o Elbows
Option V + V1 H H + H1
A) 2' (610mm) Min. 1' (305mm) Max. 2' (610mm) Max.
B) 3' (914mm) Min. 4' (1.22m) Max. 5' (1.5m) Max.
C) 4' (1.22mm) Min. 6' (1.86m) Max. 8' (2.4m) Max.
D) 5' (1.5m) Min. 8' (2.4m) Max. 12' (3.6m) Max.
With the above options, maximum total pipe length if 37 feet with
minimum of 5 feet total vertical and maximum 12 feet total horizontal.
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Page 19
Diagram 12
INSTALLATION
Vertical Flueing with Three (3) 90o Elbows
Option V + V1 H + H1
A) 2' (610mm) Minimum 3' (914mm) Maximum
B) 3' (914mm) Minimum 6' (1.86m) Maximum
C) 4' (1.22m) Minimum 9' (2.7m) Maximum
D) 5' (1.5m) Minimum 12' (3.6m) Maximum
With the above options, maximum total pipe length if 37 feet with
minimum of 5 feet total vertical and maximum 12 feet total horizontal.
manufacturer's instructions included with
the components.
1) Set the unit in its desired location. Check to
determine if wall studs or roof rafters are in
the way when the ueing system is attached.
If this is the case, you may want to adjust
the location of the unit. Rough in the gas.
2) Direct Flue pipe and ttings are designed with
special twist-lock connections to connect the
ueing system to the appliance ue outlet. A
twist-lock appliance adaptor is an available
option that must be used in conjunction
with the Simpson Dura-Vent Direct Vent GS
system.
3) Put a bead of silicone inside the outer section
of the adapter and a bead of Mill Pac on the
inner collar. Slip the adapter over the existing
inner and outer ue collar and fasten to the
outer collar only with the 3 supplied screws
(drilling pilot holes will make this easier).
Level the replace and fasten it to the framing using nails or screws through the nailing
strips.
4) Assemble the desired combination of pipe
and elbows to the appliance adaptor and
twist-lock for a solid connection.
Note:
a) Twist-lock procedure: Four indentations,
located on the female ends of pipes and
ttings, are designed to slide straight
onto the male ends of adjacent pipes
and ttings, by orienting the four pipe
indentations so they match and slide
in to the four entry slots on the male
ends, Diagram 1. Push the pipe sections
completely together, then twist-lock
one section clockwise approximately
one-quarter turn, until the two sections
are fully locked. The female locking lugs
will not be visible from the outside, on
the Black Pipe or ttings. They may be
located by examining the inside of the
female ends.
Diagram 1
Note: Apply sealant "Mill-Pac" to inner pipe
and high temperature silicone sealant
to outer pipe on every twist-lock joint.
b) Horizontal runs of ue must be sup-
ported every three feet. Wall straps are
available for this purpose.
5) Mark the wall for a 10" x 10" square hole.
The center of the square hole should line
up with the centerline of the horizontal
pipe. Cut and frame the 10 inch square
hole in the exterior wall where the ue will
be terminated. If the wall being penetrated
is constructed of non-combustible material,
i.e. masonry block or concrete, a 7"(178mm)
dia. (7-1/2"(191mm) dia. for ex) hole is
acceptable.
Note: With Dura-Vent, the minimum height
is achieved by installing a 45
to the ue adaptor.
Note:
a) The horizontal run of ue must be level,
or have a 1/4 inch rise for every 1 foot
of run towards the termination. Never
allow the ue to run downward. This
o
elbow directly
Diagram 2
could cause high temperatures and
may present the possibility of a re.
b) The location of the horizontal ue termi-
nation on an exterior wall must meet all
local and national building codes, and
must not be blocked or obstructed. For
External Flue Terminal Locations, see
diagram on page 12.
6) The arrow on the ue cap should be point-
ing up. Insure that the 1-1/2" clearances
to combustible materials are maintained
(Diagram 3 on page 16). Install the termination cap.
The four wood screws provided should
be replaced with appropriate fasteners for
stucco, brick, concrete, or other types of
sidings.
Note: If installing termination on a siding
covered wall, a vinyl siding standoff
or furring strips must be used to
ensure that the termination is not
recessed into the siding.
7) Before connecting the horizontal run of ue
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace19
Page 20
INSTALLATION
Diagram 3
pipe to the ue termination, slide the Wall
Thimble (Part # 942) over the ue pipe.
8) Slide the appliance and ue assembly
towards the wall carefully inserting the ue
pipe into the ue cap assembly. It is important
that the ue pipe extends into the ue cap
sufcient distance so as to result in a minimum pipe overlap of 1-1/4 inches. Secure
the connection between the ue pipe and
the ue cap by attaching the two sheet metal
strips extending from the ue cap assembly
into the outer wall of the ue pipe. Use the
two sheet metal screws provided to connect
the strips to the pipe section. See Diagram
4.
9) Install wall thimble in the center of the 10"
square and attach with wood screws (Diagram 5).
VERTICAL
TERMINATION
1) Maintain the 1-1/4" clearances (air spaces)
to combustibles when passing through ceilings, walls, roofs, enclosures, attic
rafter, or other nearby combustible
surfaces. Do not pack air spaces
with insulation. Check pages 17-19
for the maximum vertical rise of the
ueing system and the maximum
horizontal offset limitations.
2) Set the gas appliance in its desired
location. Drop a plumb bob down
from the ceiling to the position of
the appliance ue exit, and
mark the location where
the ue will penetrate the
ceiling. Drill a small hole
at his point. Next, drop a
plumb bob from the roof to
the hole previously drilled
in the ceiling, and mark the spot where the
ue will penetrate the roof. Determine if ceiling joists, roof rafters or other framing will
obstruct the ueing system. You may wish to
relocate the appliance or to offset, as shown
in Diagram 2 to avoid cutting
load bearing members.
3) A Firestop
spacer must be
installed in the
oor or ceiling
of every level.
To install the
Firestop spacer
Diagram 1
Diagram 2
nections are in the fully twist-locked position
and sealed.
5) Cut a hole in the roof centered on the small
drilled hole placed in the roof in Step 2. The
hole should be of sufcient size to meet
the minimum requirements for clearance
to combustibles of 1-1/4". Slip the ashing
under the shingles (shingles should overlap
half the ashing) as per Diagram 4.
6) Continue to assemble pipe lengths.
Diagram 4: The upper half of the ashing is
installed under the roong material and not
nailed down until the chimney is installed. This
allows for small adjustments.
Note: If an offset is necessary in the attic
to avoid obstructions, it is important
to support the ue pipe every 3 feet,
to avoid excessive stress on the elbows, and possible separation. Wall
straps are available for this purpose
(Diagram 2).
Galvanized pipe is desirable above the roof-
line due to its higher corrosion resistance.
Continue to add pipe sections through the
ashing until the height of the ue cap meets
the minimum height requirements specied
in Diagram 5 or local codes. Note that for
steep roof pitches, the vertical height must
be increased. A poor draft, or down drafting
Diagram 4
Diagram 5
20
Note: Apply sealant "Mill-Pac" to inner pipe
and high temperature silicone sealant to outer pipe on every twist-lock
joint.
in a at ceiling or wall, cut a 10 inch square
hole. Frame the hole as shown in Diagram
3 and install the restop.
4) Assemble the desired lengths of pipe and
elbows. Ensure that all pipes and elbow con-
Diagram 3
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Diagram 5
Roof Pitch Minimum Vent Height
Feet Meters
at to 7/12 2 0.61
over 7/12 to 8/12 2 0.61
over 8/12 to 9/12 2 0.61
over 9/12 to 10/12 2.5 0.76
over 10/12 to 11/12 3.25 0.99
over 11/12 to 12/12 4 1.22
over 12/12 to 14/12 5 1.52
over 14/12 to 16/12 6 1.83
over 16/12 to 18/12 7 2.13
over 18/12 to 20/12 7.5 2.29
over 20/12 to 21/12 8 2.44
Page 21
INSTALLATION
can result from high wind conditions near
big trees or adjoining roof lines, in these
cases, increasing the ue height may solve
the problem.
7) Ensure ue is vertical and secure the base
of the ashing to the roof with roong rails,
slide storm collar over the pipe section and
seal with a mastic.
8) Install the vertical termination cap by twist-
locking it.
Note: Any closets or storage spaces, which
the ue passes through must be
enclosed.
Offset Chart
Note: To make the
installation more
aesthetically pleasing, we recommend
framing out a square
to mount the terminal to.
2) Level the replace and fasten it to the fram-
ing using nails or screws through the nailing
strips.
3) Assemble the ue assembly by applying
Mill Pac to the 4"(100mm) inner collar of the
termination and slipping the 4"(100mm) liner
over it at least 1-3/8" (35mm). Fasten with
the 3 screws (drilling pilot holes will make this
easier). Apply Mill Pac or high temperature
silicone to the 6-7/8"(175mm) ex pipe and
slip it over the 6-7/8" outer collar of the ue
terminal at least 1-3/8"(35mm) and fasten
with the 3 screws.
NOTE: Horizontal sections must be sup-
ported at intervals not exceeding 3
feet (0.9 meter). (Flame picture and
performance will be affected by sags
in the liner).
4) Separate the 2 halves of the wall thimble and
securely fasten the one with the tabs to the
outside wall making sure that the tabs are
on top and bottom. Fasten the other thimble
half to the inside wall. The thimble halves
slip inside each other and can be adjusted
for 2 x 4 or 2 x 6 walls. Thelinersmustslip
overthecollarsaminimumof1-3/8".
5) Slip the assembled liner and termination
assembly through the thimble making sure
the termination cap faces up (there are
markings on the cap that show which way
is up). This will position the termination cap
with proper down slope for draining water.
Fasten the cap to the outer wall with the 4
supplied screws.
6) Pull the centre 4"(100mm) liner and outer
6-7/8"(175mm) liner out enough to slip over
the ue collars of the replace. (You may
wish to cut the liner shorter to make it more
workable.) Do not bend liner more than 45
7) Apply Mill Pac over the replace inner collar
and slip the 4"(100mm) liner down over it
and attach with 3 supplied screws.
8) Do the same with the 6-7/8"(175mm) liner.
9) Apply a bead of silicone between the thimble
and termination and around the outer edge
of the terminal at the wall in order to keep
the water out.
IMPORTANT: Do not locate termination hood where excessive snow or ice
buildup may occur. Be sure to check ue
termination area after snow falls, and clear
to prevent accidental blockage of ueing
system. When using snow blowers, make
sure snow is not directed towards ue
termination area.
o
.
INSTALLATION
PROCEDURES
for Regency AstroCapTM Direct
Flue System (Flex)
1) Locate the unit in the framing, rough in
the gas. Locate the centerline of the termination and mark wall accordingly. Cut a
10"(254mm) hole in the wall (inside dimension).
Note: A 1-1/2"(38mm) clearance around
the liner must be maintained except
that only a 1" (25mm) clearance is
needed at the termination end. We
recommend framing a 10"(254mm)
x 10"(254mm) (inside dimensions)
hole to give structural rigidity for
mounting the termination.
Note: If installing termination on a siding
covered wall, furring strips must be
used to ensure that the termination
is not recessed into the siding.
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace21
Page 22
INSTALLATION
PG121-1 / PG131-1 / FG39-1
PG121-1 / PG131-1 Conversion Kit #360-968 from NG to LPG
(refer to page 3 for FG39-1)
Conversion Kit# 360-968 from NG to LPG
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Conversion Kit contains:
Qty. Part # Description
1 904-529 5/32" Allen Key
1 904-641 Burner Orifi ce #50
1 918-590 "Converted to LPG" label
1 908-528 Red "LPG" label
1 910-037 #30 ULPG Pilot Orifi ce
1 918-578 Instruction Sheet
1) Shut off the gas supply and unplug the
power cord.
2) Remove louvers and trim.
3) Carefully remove the glass, logs and lava
rock.
4) Remove the grate by lifting straight up.
Remove the side brick panels (if installed). The brick panel is very fragile
- handle with care.
6) Remove burner orifi ce with a 1/2" spanner
and discard. Use another spanner to hold
on to the elbow behind the orifi ce.
Burner Orifi ce
7) Reinstall new burner orifi ce LPG stamped
#50 and tighten.
8) Pull out the pilot hood by hand.
10) Put in the new LPG orifi ce with the allen key.
Then put back the pilot hood.
11) Check the areation (10mm open) for the
LPG burner and install the burner, grate
and logs.
12) Remove the front cover by undoing the 2
screws.
5) Remove the burner assembly by removing
the 4 Phillips head screws and then slide
the burner assembly away from the orifi ce
and lift out.
Pilot Hood
9) Remove the pilot
orifi ce with the
allen key.
Pilot Hood
Removed
Pilot
Orifi ce
Front Cover
13) Stick the conversion label "This unit has
been converted to LPG" over top of the
serial number decal.
14) Replace the yellow "NG" label with the red
"LPG" label.
15) Carefully pull out the control box from un-
derneath the fi rebox.
Note: The control box is held in place with
velcro.
22
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Page 23
INSTALLATION
PG121-1 / PG131-1 / FG39-1
16) Remove the control box cover by undo-
ing the 3 screws. Maneuver through antenna.
Antenna
Control Box
Cover
17) Remove the jumper using pliers.
21) Adjusting the Outlet Pressure
All the adjustments must be carried out in
the following order:
Remove the modulator plastic cap (A) using
needle nose pliers.
Maximum pressure: Turn the unit ON to
its highest input rating. Screw in the nut (B)
to increase the outlet pressure and screw it
out to decrease it. Use a 10 mm wrench.
NOTE: The outlet pressure must be set to
maximum 2.65 kPa.
Minimum pressure: Remove one of the
cables connected to the electric modulator.
Keeping the nut (B) blocked, screw in the
screw (C) to increase the pressure and screw
it out to decrease it. Use a screwdriver 6 x
1 blade.
NOTE: The outlet pressure must be set to
minimum 0.74 kPa.
Cable
Electric
Modulator
22) At the end of all setting and adjustment
operations, check electrical insulation and
gas leaks.
23) Re-install the glass, louvers and trims.
24) Check operation of fl ame control.
25) Check for proper fl ame appearance and
glow on logs.
Installer Notice:
These instructions must be left
with the appliance.
Jumper Location
Jumper
18) Stick the conversion label "This unit has
been converted to LPG" on the control box
cover.
19) Reverse steps 16 and 15.
20) Turn on gas supply and plug in power
cord.
After carrying out all adjustments, block
the setting screws with paint, taking care
not to obstruct the breather orifi ce of the
pressure.
Put back the modulator plastic cap.
WA RNING: To ensure the correct opera-
tion of the modulator it is necessary that
the plastic cap (A) is returned to its original
location.
A
B
C
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace23
6) Pressure Regulator for Minimum and
Maximum Outlet Pressure
7) Gas Outlet Pressure Electric Modulator
8) Pilot Outlet
9) Main Gas Outlet
10) Side Outlet
11) Main Gas Inlet
The gas line can be brought through either the
right, the left side or the bottom of the appliance. The gas valve is situated on the bottom
of the unit.
The gas line connection may be made of rigid
pipe, copper pipe or an approved ex connector. (If you are using rigid pipe, ensure that the
valve can be removed for servicing.) Since some
municipalities have additional local codes it is
always best to consult with your local authorities
and AS5601-2004 (Australian Installation Code)
NZS 5261(New Zealand Installation Standard).
When using copper or ex connectors use only
approved ttings. Always provide a union so
that gas lines can be easily disconnected for
servicing. Flare nuts for copper lines and ex
connectors are usually considered to meet this
requirement.
Important: Always check for gas leaks with
24
GAS PIPE PRESSURE
TESTING
The appliance must be isolated from the gas supply piping system by closing its individual manual
shut-off valve during any pressure testing of
the gas supply piping system at test pressures
equal to or less than 3.45 kPa. Disconnect
piping from valve at pressures over 3.45 kPa.
The manifold pressure is controlled by a regulator
built into the gas control, and should be checked
at the pressure test point.
Note: To properly check gas pressure, both
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Page 25
INSTALLATION
Read the instructions below carefully and refer to the
LOG SET INSTALLATION
P121 / P131
diagrams. If logs are broken do not use the unit until
they are replaced. Broken logs can interfere with the
pilot operation.
Log Kit # 360-930 contains the following pieces:
a) 326 Front Right Log
b) 327 Front Left Log
c) 328 Middle Right Log
d) 329 Middle Left Log
e) Embers (902-154)
f) Platinum Embers (946-669) - supplied with pack-
aged manual
Please note that there are 2 of each log.
This log set is mirrored front and back.
327
LOG SET INSTALLATION
326
3) Place Log 326 on the front right side of the burner.
Ensure that the notches on the far right side of the log
fi t into the grate posts. Push back side of the left end
of the log up against the tab on the burner.
326
Push back side of the left end of the log up
against the tab on the burner.
Repeat step 3 on the opposite side of the burner.
329
The 3-digit numbers (ie. 327) are molded into the rear of each log.
1) Carefully remove the logs from the box and unwrap
them. The logs are fragile, handle with care - do not
force into position.
2) Place embers on the burner as shown below.
Separate platinum embers and place on the burner
over top of and around embers. Platinum embers can
cover burner ports. Avoid stacking platinum embers.
328
326
326
4) Place Log 327 on the front left side of the burner. Po-
sition the right end of the log in between the two tabs
and the left end of the log into the grate post.
327
IMPORTANT
When placing Embers, do not block burner ports
as this can cause an incorrect fl ame pattern,
carbon deposits and delayed ignition.
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace25
Grate Post
Tab on Burner
Page 26
INSTALLATION
LOG SET INSTALLATION
P121 / P131
328327329326
Completed Log Set Installation:
326329328
327
Repeat step 4 on the opposite side of the burner.
327
5) Place Log 329 on the middle left side of the burner.
Rest the bottom of the Log onto the second grate post
from the left. Ensure that the log fi ts into a pin that is
on Log 326.
327
6) Place Log 328 on the middle right side of the burner.
Ensure that the log fi ts over the 2nd grate post from
the right.
Repeat step 6 on the opposite side of the burner.
328
328
Grate Post
329
Grate Post
Repeat step 5 on the opposite side of the burner.
329
326
Pin
329
328
26
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Page 27
GLASS DOOR
REMOVAL
1) Remove the 8 screws that secure the glass
door.
2) Pull the door slightly out on an angle and
then lift up and pull completely out.
FINISHING TRIM
1) Slide the Side Finishing Trim up into the slot
in the top ange of the replace. Push tight
against the magnet at the base of the unit.
Slide Trim into
slot.
Push trim tight
against magnet.
LOUVERS & GRILLS
1) Attach the screws provided to the top left
and right corners.
NOTE: Do not tighten the screw entirely,
ensure that some room is left to be able to
hang the grill or louver over the screw.
2) Hang the Top Louver or Grill onto the 2
screws in the top replace opening.
3) Attach the Bottom Louver or Grill to the
hinges on the bottom ange of the replace.
PG121-1 & PG131-1 Corner Models
3) PG131-1 & PG121LC-1/PG121RC-1
Corner Model: Remove the 6 screws that
secure the glass door and repeat step 2.
2) Slide the Corner Finishing Trim up into the
slot in the top ange of the replace. Push
tight against the magnet at the base of the
unit.
Slide Trim into
slot.
Push trim tight
against magnet.
4) Attach the screws provided to the top and
bottom, left and right corners similar to step
1.
5) Hang the top and bottom louver or grill onto
the screws in the top and bottom, left and
right sides of the replace opening.
The Top and Bottom Side Louver or Grill is
installed the same way.
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace27
Page 28
INSTALLATION
FLAME SENSOR
SPARK IGNITOR
PILOT
BROWN (ACTIVE)
BLUE (NEUTRAL)
VIOLET
BLUE
BROWN
WHITE
RED
BLACK
FAN
FAN
Hi
Com
Lo
Hi
Lo
Com
TERMINAL
BLOCK
BLACK
RED
WHITE
SIT 201 IGNITION CONTROL MODULE
JUMPER
21
ORANGE
ORANGE
MODULE-SPARK
BLACK
12 11 910 8765432
RESET SWITCH (NC)
YELLOW
VIOLET
YELLOW
BLACK
1
SIGMA 845 VA LVE
RED
BLUE
GREEN
BROWN
3
5
4
2
1
SIT
MODULATING
(MD)
COIL
ORANGE
ORANGE
RED
RED
MODULE-FLAME
MODULE-GROUND
GREEN
MED
FAN
NEUTRAL
NEUTRAL
COMMAND BOX
ACTIVE
LOW
THERM
HIGH
TH2
TH1
MOD1
MOD2
GND
GND
GND
REMOTE CONTROL
Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty.
The remote control kit comes with a hand held transmitter and a wall mounting plate.
1) Choose a convenient location to mount the hand held transmitter, protection from extreme heat is very important.
The remote can also be used as a wall thermostat.
WIRING DIAGRAM
This heater requires a 240V A.C. supply for the
gas control to operate. A 240V A.C. power supply
is needed for the fan/blower operation.
28
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
CAUTION: Label all wires prior
to disconnection when servicing controls. Wiring errors can
cause improper and dangerous
operation.
Page 29
OPERATING INSTRUCTIONS
OPERATING
INSTRUCTIONS
Before operating this appliance, proceed through
the following check list.
1) Read and understand these Instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the three pieces of door glass
are properly positioned. Never operate the
appliance with any of the glass removed or
with the door open.
5) Verify that all ueing and the cap is unob-
structed.
6) Verify log placement.
LIGHTING
INSTRUCTIONS
1) Plug the power cord into a power outlet.
2) Press and release the ON/OFF button once
to start the unit.
3) After approximately 3 seconds the spark
ignition system will spark for 40 seconds to
light the main burner.
RESETTING
THE UNIT
1) Open the bottom louvre of the unit.
2) Press and release the reset button, located
on the unit's control panel once.
3) Wait for approximately 3 seconds and the
pilot sparks can be heard and seen. It would
take 2 to 3 seconds for the ame to be lit.
NOTE: A period of 30 seconds must pass before
another reset is attempted.
SHUTDOWN
INSTRUCTIONS
1) Press the ON/OFF button once.
2) Turn off all electric power to the appliance
if service is to be performed.
FAN OPERATION
Set the fan speed on the control panel located
in behind the bottom louvre.
Pressing and releasing the plus (+) FAN button
will change the fan speed as follows:
OFF -> LOW -> MEDIUM -> HIGH -> OFF, etc.
Pressing and releasing the minus (-) FAN button
will be the reverse of the above.
ADJUSTING FLAME
HEIGHT
There are six ame settings that can be adjusted
by pressing and releasing the plus (+) and minus
(-) FLAME button.
The FLAME setting button is located on the
control panel in behind the pedestal door.
4) If the main burner does not light, reset the
unit.
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace29
Page 30
OPERATING INSTRUCTIONS
FIRST FIRE
DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.
The rst re in your stove is part of the paint curing process. To ensure that the paint is properly
cured, it is recommended that you burn your
replace for at least four (4) hours the rst time
before you use it with the fan on.
When rst operated, the unit will release an odour
caused by the curing of the paint, the burning
off of any oils remaining from manufacturing.
Smoke detectors in the house may go off at this
time. Open a few windows to ventilate the room
for a couple of hours.
Note: When the glass is cold and the appli-
ance is lit, it may cause condensation
and fog the glass. This condensation
is normal and will disappear in a few
minutes as the glass heats up.
During the rst few res, a white lm may
develop on the glass front as part of the
curing process. The glass should be cleaned
after the unit has cooled down or the lm
will bake on and become very difcult to
remove. Use a non-abrasive cleaner and
DO NOT ATTEMPT TO CLEAN THE GLASS
WHILE IT IS HOT.
NORMAL OPERATING
SOUNDS OF GAS
APPLIANCES
It is possible that you will hear some sounds
from your gas appliance. This is perfectly normal
due to the fact that there are various gauges
and types of steel used within your appliance.
Listed below are some examples. All are normal operating sounds and should not be considered
as defects in your appliance.
Blower:
Regency gas appliances use high tech blowers
to push heated air farther into the room. It is not
unusual for the fan to make a "whirring" sound
when ON. This sound will increase or decrease
in volume depending on the speed setting of
your fan speed control.
Burner Tray:
The burner tray is positioned directly under the
burner tube(s) and logs and is made of a different gauge material from the rest of the rebox
and body. Therefore, the varying thicknesses of
steel will expand and contract at slightly different
rates which can cause "ticking" and "cracking"
sounds. You should also be aware that as there
are temperature changes within the unit these
sounds will likely re-occur. Again, this is normal
for steel reboxes.
Gas Control Valve:
As the gas control valve turns ON and OFF, a
dull clicking sound may be audible, this is normal
operation of a gas regulator or valve.
AERATION
ADJUSTMENT
The burner aeration is factory set. Adjustment
may be needed due to the local gas supply or
altitude. As a general rule if the ame is too yellow open up the air shutter, if it is too blue close
the air shutter.
NG 10mm open
LPG 10mm open
NOTE:
This adjustment is only to be made by an
authorised person.
Carbon deposits are a possibility on appli-
ances incorporating live fuel effect ames.
Unit Body/Firebox:
Different types and thicknesses of steel will
expand and contract at different rates resulting
in some "cracking" and "ticking" sounds will be
heard throughout the cycling process.
30
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Page 31
OPERATING INSTRUCTIONS
COPY OF THE LIGHTING PLATE INSTRUCTIONS
MAINTENANCE
INSTRUCTIONS
Any maintenance required accessing the
glass door of the unit must be performed
by an authorized service person.
1) Always unplug the power cord before
cleaning. For relighting, refer to lighting
instructions. Keep the burner and control
compartment clean by brushing and vacuuming at least once a year. When cleaning
the logs, use a soft clean brush as the logs
are fragile and easily damaged.
2) Clean glass (never when unit is hot), appli-
ance, louvres, and door with a damp cloth.
Never use an abrasive cleaner. The gold
louvres (and optional gold door) may be
scratched if abrasives are used to clean
them.
The heater is nished in a heat resistant
paint and should only be renished with
heat resistant paint (not with wall paint).
Regency uses StoveBright Paint - Metallic
Black #6309.
3) Make a periodic check of burner for proper
position and condition. Visually check the
ame of the burner periodically, making sure
the ames are steady; not lifting or oating.
If there is a problem, call an authorized
service person.
4) The appliance and ueing system must be
inspected before use, and at least annually, by an authorized eld service person,
to ensure that the ow of combustion and
ventilation air is not obstructed.
During the annual service call, the burners
should be removed from the burner tray
and cleaned. Replace the embers - do not
block the pilot or burner ports.
5) Keep the area near the appliance clear and
free from combustible materials, gasoline
and other ammable vapours and liquids.
General Flue Maintenance
Conduct an inspection of the ueing system
semi-annually. Recommended areas to inspect
as follows:
1) Check the Flueing System for corrosion in
areas that are exposed to the elements.
These will appear as rust spots or streaks,
and in extreme cases, holes. These components should be replaced immediately.
2) Remove the Cap, and shine a ashlight
down the Flue. Remove any bird nests, or
other foreign material.
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace31
Page 32
MAINTENANCE
3) Check for evidences of excessive condensa-
tion, such as water droplets forming in the
inner liner, and subsequently dripping out the
joints, Continuous condensation can cause
corrosion of caps, pipe, and ttings. It may
be caused by having excessive lateral runs,
too many elbows, and exterior portions of
the system being exposed to cold weather.
4) Inspect joints, to verify that no pipe sections
or ttings have been disturbed, and consequently loosened. Also check mechanical
supports such as Wall Straps, or plumbers'
tape for rigidity.
LOG REPLACEMENT
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door and carefully remove the
logs. (The pilot light generates enough heat to
burn someone.) If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagrams under Log
Installation.
Note: Improper positioning of logs may cre-
ate carbon build-up and will severely
alter the unit's performance which is
not covered under warranty.
DOOR GLASS
Your Regency replace is supplied with high
temperature 5mm-Tempered glass & 5mmCeramic glass. If your glass requires cleaning,
we recommend using an approved glass cleaner
available at all authorized dealers. Do not use
abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all prod
uct warranties.
* Care must be taken to avoid breakage of
the glass.
* Do not strike or abuse the glass.
* Do not operate this replace without the
glass front or with a cracked or broken glass
front.
* Wear gloves when removing damaged or
broken glass.
* Replacement of the glass panels should be
done by a licensed or authorized service per
son.
GLASS REPLACEMENT
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency dealer only. Replacement glass is
shipped already installed into the door frame.
VALVE TRAY
REPLACEMENT
1) Shut off the gas supply.
2) Remove the louvers and trim kit. Remove
the front door.
3) Remove the logs, embers.
4) Remove the grate by lifting straight up.
5) Remove the side brick clip in the top of the
rebox and then slide the Side Brick Panel
out. The brick panels are very fragile -
handle with care.
GLASS GASKET
If the glass gasket requires replacement use a
tadpole glass gasket (Part # 936-155).
REPLACEMENT PARTS:
Front Door - Tempered (Part# 360-528/P)
Side Door - Tempered (Part# 360-529/P)
Front Door - Ceramic (Part# 360-946)
Side Door - Ceramic (Part# 360-948)
GOLD-PLATED
ACCESSORIES
The 24 carat gold-plated nish requires little
maintenance, and need only be cleaned with a
damp cloth. DO NOT use abrasive materials or
chemical cleaners, as they may harm the nish
and void the warranty. Clean any ngerprints
off before turning the unit on.
32
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Page 33
MAINTENANCE
6) Remove the burner by removing the 4
screws.
7) Slide the burner assembly away from the
orice and lift out.
8) Remove the Side Base Brick Panels and
nally the Long Base Brick Panels.
9) Open the bottom louvre and remove the 2
screws which secure the front cover to the
valve tray.
10) Unplug the 5 pin Molex Connector and
carefully pull out the control box.
5 Pin Molex
Connector
11) Disconnect the inlet gas line.
15) Remove the 16 screws that secure the valve
tray.
16) Lift the entire assembly out.
17) To replace the burner tray assmebly, reverse
these instructions.
18) Check for any gas leaks.
19) Check for proper ame appearance and
glow on logs.
Remove Left & Right Side Base
Brick Panels
Remove the 2 Long Base Brick Panels
12) Unplug the 2 orange wires from the Gas
Pressure Electronic Modulator.
13) Unplug the 5 pin Molex Connector from the
valve.
14) Unplug the igniter and the ame cables from
the module.
Igniter and Flame
Cables
5 Pin Molex Con-
nector from the
Valve.
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace33
Page 34
MAINTENANCE
MANUAL CONTROL REPLACEMENT
1) Unplug the power source.
2) Open the bottom louver.
3) Undo the 3 screws to remove the manual control box from the
louver.
4) Remove the louver bracket from the manual control box by undoing
one screw.
7) Remove the ECS box cover by undoing the 3 screws.
8) Unplug in the CAT5 cable of the manual control box from the con-
nector in the ECS box.
Louver Bracket
5) Remove the valve heat shield by undoing the 2 screws.
Valve Heat Shield
6) Pull out the ECS box by carefully lifting it up off the velcro.
ECS Box
Manual Control Box
9) Plug the replacement manual control switch CAT5 cable into the
connector in the ECS box.
10) Re-install the cover on the ECS box. Ensure to t the rest of the cable
into the groove in the ECS box.
11) Put the ECS box back in place under the rebox.
12) Reverse steps 5 to 1.
34
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Page 35
PARTS LIST
ELECTRONIC COMPONENTS PARTS LIST
Note: Depending on the model, the diagram below may not be exactly as shown - for reference purposes only.
910-084
910-526
910-909 Fan Resistor
910-936 Intermittent Pilot
910-082 Direct Spark Ignitor
910-089 Flame Cable
910-088 Spark Cable
910-084 Control Box
910-527 Manual Control Switch
910-080 Valve
910-521 Control Box Cable (1)
910-522 Control Box Cable (2)
910-523 Control Box Cable (3)
910-525 Control Box Cable (4)
**Note: The Control Box Cable wires for the FG38 come separately: 910-502, 910-505, 910-506, 910-507, 910-509
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace35
N/A
N/AN/A
N/AN/AN/AN/A
N/A
N/A
Page 36
PARTS LIST
PG121-1 (SEE THRU) MAIN ASSEMBLY
Part # Description Part # Description Part # Description
1) 360-528/P Door Assy Front - Tempered
360-946 Door Assy Front - Ceramic
(Optional)
9) 360-046 Nailing Strip - Top - Front
10) 360-047 Nailing Strip - Top - Side
11) 430-001 Standoff - Top
17) 360-086 Gasket - Relief Door
24) * Relief Door Assembly
32) 362-528 Brick Panel - Base - Front
33) 362-528 Brick Panel - Base - Side
34) 902-603 Brick Panel - Side
135) 360-069 Heat Shield - Side
146) 360-035 Finishing Trim
150) 360-123 Magnet Bracket - Front
151) 904-258 Magnet
168) 360-068 Door Cover Assembly - Side
171) 360-920 Louver Front - Black (set)
360-922 Louver Front - Black/Gold (set)
360-924 Louver Front - Black/Steel (set)
360-926 Louver Front - Black/Brass (set)
181) * Extension Trim - See Thru
204) 360-940 Dec. Grill Front - Black (set)
205) 948-216 Regency Logo Plate
206) 910-172 Fan Axial 240V
918-648 Manual
*Not available as a replacement part.
36
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Page 37
PARTS LIST
PG131-1 (PIER) MAIN ASSEMBLY
Part # Description Part # Description Part # Description
1) 360-528/P Door Assy Front - Tempered
360-946 Door Assy Front - Ceramic
(Optional)
2) 360-529/P Door Assy Side - Tempered
360-948 Door Assy Side- Ceramic
(Optional)
9) 360-046 Nailing Strip - Top - Front
10) 360-047 Nailing Strip - Top - Side
11) 430-001 Standoff - Top
17) 360-086 Gasket - Relief Door
24) * Relief Door Assembly
32) 362-528 Brick Panel - Base - Side
33) 362-528 Brick Panel - Base - Front
34) 902-603 Brick Panel - Side
141) 360-031 Column Finishing Trim
146) 360-035 Finishing Trim
149) 360-122 Magnet Bracket - Corner
150) 360-123 Magnet Bracket - Front
151) 904-258 Magnet
171) 360-920 Louver Front - Black (set)
360-922 Louver Front - Black/Gold (set)
360-924 Louver Front - Black/Steel (set)
360-926 Louver Front - Black/Brass (set)
173) 360-932 Louver Side - Black (set)
360-934 Louver Side - Black/Gold (set)
360-936 Louver Side - Black/Steel (set)
360-938 Louver Side - Black/Brass (set)
181) * Extension Trim - Pier
204) 360-940 Dec. Grill Front - Black (set)
206) 910-172 Fan Axial 240V
224) 360-942 Dec. Grill Side - Black (set)
225) 948-216 Regency Logo Plate
918-648 Manual
*Not available as a replacement part.
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace37
Page 38
PARTS LIST
PG121RC-1 (RIGHT CORNER) MAIN ASSEMBLY
Part # Description Part # Description Part # Description
1) 360-528/P Door Assy Front - Tempered
360-946 Door Assy Front - Ceramic
(Optional)
2) 360-529/P Door Assy Side - Tempered
360-948 Door Assy Side - Ceramic
(Optional)
9) 360-046 Nailing Strip - Top - Front
10) 360-047 Nailing Strip - Top - Side
11) 430-001 Standoff - Top
780-013 Standoff - Rear
17) 360-086 Gasket - Relief Door
24) * Relief Door Assembly
32) 362-528 Brick Panel - Base - Side
33) 362-528 Brick Panel - Base - Front
34) 902-603 Brick Panel - Side
35) 902-604 Brick Panel - Front
138) 360-063 Heat Shield - Front
141) 360-031 Column Finishing Trim
146) 360-035 Finishing Trim - Left Side
149) 360-122 Magnet Bracket - Corner
150) 360-123 Magnet Bracket - Front
151) 904-258 Magnet
158) 360-060 Door Cover Assembly-Front
171) 360-920 Louver Front - Black (set)
360-922 Louver Front - Black/Gold (set)
360-924 Louver Front - Black/Steel (set)
360-926 Louver Front - Black/Brass (set)
173) 360-932 Louver Side - Black (set)
360-934 Louver Side - Black/Gold (set)
360-936 Louver Side - Black/Steel (set)
360-938 Louver Side - Black/Brass (set)
181) * Extension Trim
204) 360-940 Dec. Grill Front - Black (set)
206) 910-172 Fan Axial 240V
224) 360-942 Dec. Grill Side - Black (set)
225) 948-216 Regency Logo Plate
918-648 Manual
*Not available as a replacement part.
38
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Page 39
PARTS LIST
PG121LC-1 (LEFT CORNER) MAIN ASSEMBLY
Part # Description Part # Description Part # Description
1) 360-528/P Door Assy Front - Tempered
360-946 Door Assy Front - Ceramic
(Optional)
2) 360-529/P Door Assy Side - Tempered
360-948 Door Assy Side - Ceramic
(Optional)
9) 360-046 Nailing Strip - Top - Front
10) 360-047 Nailing Strip - Top - Side
11) 430-001 Standoff - Top
17) 360-086 Gasket - Relief Door
24) * Relief Door Assembly
32) 362-528 Brick Panel - Base - Side
33) 362-528 Brick Panel - Base - Front
34) 902-603 Brick Panel - Side
35) 902-604 Brick Panel - Front
138) 360-069 Heat Shield - Front
141) 360-031 Column Finishing Trim
146) 360-035 Finishing Trim
149) 360-122 Magnet Bracket - Corner
150) 360-123 Magnet Bracket - Front
151) 904-258 Magnet
158) 360-062 Door Cover Assembly-Front
171) 360-920 Louver Front - Black (set)
360-922 Louver Front - Black/Gold (set)
360-924 Louver Front - Black/Steel (set)
360-926 Louver Front - Black/Brass (set)
173) 360-932 Louver Side - Black (set)
360-934 Louver Side - Black/Gold (set)
360-936 Louver Side - Black/Steel (set)
360-938 Louver Side - Black/Brass (set)
204) 360-940 Dec. Grill Front - Black (set)
206) 910-172 Fan Axial 240V
224) 360-942 Dec. Grill Side - Black (set)
225) 948-216 Regency Logo Plate
918-648 Manual
*Not available as a replacement part.
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace39
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace41
Page 42
WARRANTY
Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each
unit thoroughly before it leaves our door. Regency® is pleased to extend this limited lifetime warranty to the original purchaser of a Regency® Product.
Regency® will repair or replace goods free of charge in the event of defects arising from faulty materials or workmanship in accordance with the warranty
terms in relation to Denitions, Warranty Conditions and Exclusions stated in this document.
The benets to the consumer given by this warranty are in addition to all other rights and remedies of the consumer under a law in relation to the goods or services
to which the warranty relates.
Our goods come with the guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and
for compensation for any other foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality
and the failure does not amount to a major failure.
The Warranty: Lifetime
Covered under the agreement are the following components: The combustion chamber, heat exchanger, burner tubes/pans, logs, glass crystals, ceramic spa stones,
pebbles, brick panels and gold plating (against defective manufacture only) are covered under the Limited Lifetime Warranty for ve (5) years for parts and labour
and parts only thereafter.
External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and labour for one (1) year from the date of
purchase and parts only thereafter.
Regency Fireplace Products is not liable for freight or labour on any gas appliance replaced in the eld.
Special Finishes - One year on stainless steel panels, nickel overlays, nickel faceplates, brushed nickel and antique copper full screens and doors. You can expect
some changes in color as the product "ages" with constant heating and cooling. FPI warranties the product for any manufacturing defects on the original product.
However, the manufacturers warranty does not cover changing colors and marks, ie. nger prints, etc applied after the purchase of the product. Damage from the use
of abrasive cleaners is not covered by warranty.
Electrical components such as fans, switches, ignition modules, wiring, thermodiscs, remote control, thermopiles, thermocouples and gas valves are covered for one
year for parts and labour from the date of purchase.
The warranty on brass parts is for one year, no labour. The brass is not warranted against tarnishing.
®
Repair/replacement parts purchased by the consumer from Regency
only. Any item shown to be defective will be repaired or replaced at our discretion. No labour coverage is included with these parts.
Conditions:
All installations must be performed by a qualied gas tter and installed according to all applicable local and national codes. Also, all service work must be carried
out by a qualied gas service person provided by the selling dealer. It is the responsibility of the installer to ensure that the appliance is ring as per rating plate. Any
part or parts of this unit which in our judgement show evidence of such defect will be repaired or replaced at Regency
agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested. In areas where there is not an approved service
agent or the closest approved service agent is situated more than thirty (30) kilometres from the installation, Regency is not obliged to arrange warranty repairs and
travel and/or additional labour charges will apply.
Porcelain/Enamel - Absolute perfection is neither guaranteed nor commercially possible. Any chips must be reported and inspected by an authorised dealer within
three days of installation. Reported damage after this time will be subject to rejection.
®
It is the general practice of Regency
and evaluated fro manufacturer defect.
At all time Regency reserves the right to inspect product in the eld which is claimed to be defective.
All claims must be submitted to Regency® by authorised selling dealers. It is essential that all submitted claims provide all of the necessary information including
customer name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.
Exclusions:
This limited Lifetime Warranty does not extend to or include paint, door or glass gasket or trim. It does not cover installation and operational related problems such
as over-ring, down drafts or spillage caused by environmental conditions, nearby trees, buildings, hilltops, mountains, inadequate ueing or ventilation, excessive
offsets, negative air pressures caused by insufcient make up air, mechanical systems such as furnaces, fans, clothes dryers etc.
Embers, rockwool, gaskets, door handles and paint are not covered under the terms of this warranty policy.
®
Regency
Performance problems due to operator error will not be covered by this warranty policy.
The warranty does not extend to any part or parts which show evidence of misuse or abuse, neglect, accident, lack of maintenance, or improper installation.
Products made by other manufacturers and used in conjunction with the operation of this appliance without authorisation from Regency
on this product.
Regency shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the
product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of Regency Fireplace Products.
SUBJECT TO CHANGE.
will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.
to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to Regency
after the original coverage has expired on the unit will carry a 90 day warranty valid with a receipt
®
's option, through an accredited distributor or
®
, may nullify your warranty
42
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
Page 43
DISTRIBUTORS:Western AustraliaEastern Australia
Air Group Australia
28-30 Division St.
Welshpool, WA 6106Hallam, VIC 3803
08 9350 220003 9799 7277
Fireplace Products Australia PTY. Ltd.
1-3 Conquest Way
WARRANTY
NOTE: PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY
INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY
A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES.
VERIFICATION
WARRANTY
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace43
Page 44
Register your Regency® warranty online
www.regency-re.com.au
Reasons to register your product online today!
• View and modify a list of all your registered products.
• Request automatic email notication of new product updates.
• Stay informed about the current promotions, events, and special
offers on related products.
• Help assure you get the most out of your warranty.
• Eliminate confusion and frustration if warranty** service is required in
the future.
** Proof of purchase required at time of warranty request.