Regency P48-NG2, P48-LP2 User Manual

Page 1
G
H
I
K
J
L
O
P
N
M
11" (279mm)
dia. Hole through
wall Vent.
Opening for gas
connection
Top Header
Drywall
(or other
facing)
Gas Fireplaces
P48 Gas Fireplace
P48 Zero Clearance Direct Vent Gas Fireplace
Model P48-NG2 P48-LP2
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5” W.C. (1.25 kPa) 12” W.C. (3.00 kPa)
Manifold Pressure - High 3.8” W.C. (0.95 kPa) 11” W.C. (2.74 kPa)
Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 3.3” W.C. (0.82 kPa)
Orifi ce Size #27 DMS - 0-4500ft #47 DMS
Minimum Input 29,000 BTU/h (8.49 kW) 26,000 BTU/h (3.07 kW)
Vent Sizing 5” Inner / 8” Outer 5” Inner / 8” Outer
Approved Venting Systems
Flex Vent Systems: FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems: Simpson Dura-Vent® Direct Vent GS
B
A
Gas Fireplaces
DC
A
Unit Dimensions Description P33
A Front Face Width 48” (1219mm)
B Rear Firebox Width 34-1/2” (876mm)
C Front Face Height 41” (1041mm)
D Height w/ Standoff 47” (1193mm)
E Unit Depth 23-1/4” (324mm)
F Firebox Height 40” (1016mm)
Framing Dimensions Description P33
G Framing Width 48-1/2” (1232mm)
H*** Framing Height*** 47-1/2” (1207mm)***
I Framing Depth
J Corner Wall Length 57-5/8 ” (1464mm)
K Corner Facing Wall Width 81-1/2” (2070mm)
L Framed Chase Ceiling
M Vent Centerline Height 43” (1092mm)
N Gas Connection Height 2” (51mm)
O Gas Connection Inset 3-3/4” (95mm)
P Gas Connection Width 5” (127mm)
Important: Framing height requires consideration of the hearth
***
depth. Dimension H = H + the thickness of installed hearth.
29-3/4” (756mm) Vertical Rise
26-1/4” (667mm) No Vertical Rise
50” (1270mm) No Vertical Rise
E
N/A - Vertical Rise
F
Please refer to Page 11 (Exterior Vent Terminations)
for additional guidelines on vent locations.
61June 2007 Regency Product Specifi cations Book
Page 2
P48 Gas Fireplace
Framing and Finishing
1) Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the fi nished surface to be fl ush with the front of the unit. Total facing thickness can vary from 1/2” (13mm) to 1-¼” (32mm) thick.
2) Frame in the enclosure for the unit with framing material.
Gas Fireplaces
3) For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapor barrier and drywall, as per local installation codes. (Do not insulate the fi replace itself.)
4) The top of the unit must not be closer than 39” (990mm) to the ceiling.
5) Combustible material may be brought up to the top and sides of the unit and be covered with ceramic tiles, bricks, rock or other suitable combustible finishing materials.
Note: The unit does not have to be completely enclosed in a chase. The clearance on top of the unit is 0” to the standoffs so combustible building materials can be laid directly on top of the standoffs. You must maintain proper clearances from the vent to combustible materials (See Below).
6) Use metal studs for framing where the minimum clearance from
the vent to combustible material cannot be maintained.
Clearance Requirements
Gas Fireplaces
Vent Clearances Clearance Dimension
Horizontal - Top 2-1/2” (64mm)
Horizontal - Side 1-1/2” (38mm)
Horizontal - Bottom 1-1/2” (38mm)
Vertical 1-1/4” (32mm)
Failure to maintain required clearances is a major cause of chimney related fi res. Installation of this fi replace must comply with these clearances.
Combustible Mantels
Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of
the louvers are shown in the diagram below. Mantel may be installed anywhere in the shaded area or higher.
WARNING
Mantel Clearances
12
64810
12" (305mm)
0
2
D
C
A
F
B
B
E
Clearance: Dimension Measured From:
A: Mantel Height 8” (203mm) Minimum (Additional on this page)
B: Sidewall 6” (152mm) Side of installed front
C: Ceiling 36” (914mm) Top of installed unit
D: Mantel Depth 12” (305mm) Maximum (Additional on this page)
E: Alcove Width 60” (1524mm) Sidewall to Sidewall (Minimum)
F: Alcove Depth 36” (914mm) Front to back wall (Maximum)
Top of Hearth must not be higher than the base of the fi rebox.
D
Side View
Drywall
Header
Standoff
5 ½” (140mm)
3 ½" (89mm)
B
0
Mantel Clearances
Front 41” (1041mm) 15” (381mm) 10” (254mm) 8” (203mm)
C
Top of
Louvers
A
ABCD
Note: If desired a non-combustible mantel may be installed at a
lower height.
Note: Ensure the paint that is used on the mantel and the facing
is “heat resistant” or the paint may discolour.
Mantel Leg Clearances
Combustible mantel leg clearances as per diagram below: Clearances are from the fi nished edge of the unit
Side Wall (Min 6”)
P48
Maximum 1-½” projection at 3” minimum clearance.
Mantel leg
1-1/2"
3”
6”
Allowable mantel leg
projection.
Mantel leg
3”
62 June 2007 Regency Product Specifi cations Book
Page 3
Alternate Snorkel
Termination Cap
Part #1282 (14”) Part #1281 (36”)
Gas Fireplaces
Regency Direct Vent System (Flex)
Horizontal Terminations Only
These venting systems, in combination with the P48 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram.
FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the P48 using a fl exible vent.
FPI Kit # Length Contains:
#946-618 6 Feet 1) 6-5/8” fl exible liner (Kit length)
#946-616 10 Feet
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency may be used for Flex installations.
3) Horizontal sections must be supported every 3 feet.
2) 4” fl exible liner (Kit length)
3) spring spacers (3)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) S.S. screws #8 x 1-1/2” drill point, (4)
10) vinyl siding standoff
AstroCap XL
(Part# 946-623/P)
Vinyl Siding
Standoff
Wall Thimble
P48 Gas Fireplace
Snorkel Terminations
Gas Fireplaces
Snorkel Terminations:
For installations requiring a vertical rise on the exterior of the building, 14­inch and 36-inch tall Snorkel Terminations are available. Follow the same installation procedures as used for standard Horizontal Termination. NEVER install the snorkel upside down.
Dura-Vent
Snorkel
Min. 12"* (305mm)
Below Grade Snorkel Installation (Dura-Vent Only)
If the Snorkel Termination must be installed below grade, i.e. basement application, proper drainage must be provided to prevent water from entering the Snorkel Termination. Refer to Rigid Pipe Installation instructions for details. Do not attempt to enclose the Snorkel within the wall, or any other type of enclosure.
5” dia.
Flue pipe
8" dia.
Flue pipe
Spring Spacer
Alternate Horizontal
Termination Caps
If required by the external termination location the listed alternate termination caps may be used. (Refer to Page 11)
Dura-Vent
Snorkel
Adequate
drainage
Gravel
Window
Well
(305mm)
Min. 12"*
63June 2007 Regency Product Specifi cations Book
Page 4
6
8
10
12
10
12
12 16
18
20 26
28
22 24
30
P48 Gas Fireplace
Alternate Snorkel
Termination Cap
Part #1282 (14”) Part #1281 (36”)
Rigid Pipe Venting
Horizontal or Vertical Terminations
Vertical
Terminal
Storm Collar
Gas Fireplaces
Flashing
Vinyl Siding
Standoff
Gas Fireplaces
2
0
40
4
8
6
10 12
14
Ceiling Firestop
Pipe Length
Adj.Pipe Length
o
90 Elbow
24" Length
Adj.Pipe Length
o
45 Elbow
Rigid Pipe Adapter
11" - 14-5/8”
# 770-994
Wall Thimble
11" - 14-5/8”
Wall Thimble
Alternate Horizontal
Termination Caps
Horizontal
Termination Cap
# 946-623/P
Termination Cap
# 946-623/P
Vinyl Siding
Standoff
Horizontal
38
36
34
32
30
28
26
24
22
20
Maximum: 40 ft. (12.2m)
If required by the external termination location the listed alternate termination caps may be used. (Refer to Page 11)
18
Venting Arrangements - Vertical Terminations
Rigid Pipe System
(Propane & Natural Gas)
The P48 is approved for a maximum 40 ft. straight vertical, with Rigid Pipe vent systems for Propane and Natural Gas.
The lightly shaded area, confi gurations with a maximum two 45° elbows allowed.
The darker shaded area, confi gurations using 45° and one 90° elbow.
Vent must be supported at offsets.
Horizontal sections must be supported every 3 feet.
• Firestops are required at each floor level and whenever
Maintain clearances to combustible materials.
Minimum of 1’ pipe section between elbows.
Note: Must use optional fl ue adapter when using Rigid Pipe (Part
64 June 2007 Regency Product Specifi cations Book
passing through a wall.
# 770-994).
, in the diagram shows allowable venting
, in the diagram shows allowable venting
Vertical Height (Feet)
16
14
12
10
8
6
4
2
0
Minimum 12” (305mm)
Minimum 10’6” (3.2m)
Minimum 8’6” (2.6m)
Max. 10’ (3m)(centerline to centerline)
Maximum: 27 ft. (8.2m)
Page 5
Gas Fireplaces
Vertical Venting with Two (2) 90° Elbows
- Initial vertical section.
Two 45° elbows = One 90° elbow
P48 Gas Fireplace
Vertical Venting with Three (3) 90° Elbows - Initial vertical section.
Two 45° elbows = One 90° elbow
Gas Fireplaces
Option V H V+ V1 Maximum total pipe: length, of
A) 1’ Min. 4’ Max. 2’ Min.
B) 2’ Min. 5’ Max. 3’ Min.
C) 3’ Min. 6’ Max. 4’ Min.
D) 4’ Min. 7’ Max. 5’ Min.
E) 5’ Min. 8’ Max. 6’ Min.
all sections, must not exceed 30 feet. Total horizontal sections must not exceed 8 feet.
Minimum of 1 foot between 90° elbows is required.
Vertical Venting with Two (2) 90° Elbows
- Initial horizontal section.
Two 45° elbows = One 90° elbow
Option H + H1 V Maximum total pipe: length, of
A) 2’ Max. 2’ Min.
B) 3’ Max. 3’ Min.
C) 4’ Max. 4’ Min.
D) 5’ Max. 5’ Min.
E) 6’ Max. 6’ Min.
all sections, must not exceed 30 feet. Total horizontal sections must not exceed 6 feet.
Minimum of 1 foot between 90° elbows is required.
Option V H + H1 V+ V1 Maximum total pipe: length, of
A) 2’ Min. 3’ Max. 4’ Min.
B) 3’ Min. 4’ Max. 6’ Min.
C) 4’ Min. 5’ Max. 7’ Min.
D) 5’ Min. 6’ Max. 8’ Min.
E) 6’ Min. 7’ Max. 9’ Min.
F) 7’ Min. 8’ Max. 10’ Min.
all sections, must not exceed 30 feet. Total horizontal sections must not exceed 8 feet.
Minimum of 1 foot between 90° elbows is required.
Vertical Venting with Three (3) 90° Elbows - Initial horizontal section.
Two 45° elbows = One 90° elbow
Option H V H + H1 V+ V1 Maximum total pipe:
A) 1’ Max. 1’ Min. 3’ Max. 3’ Min.
B) 2’ Max. 2’ Min. 4’ Max. 5’ Min.
C) 3’ Max. 3’ Min. 5’ Max. 7’ Min.
D) 4’ Max. 4’ Min. 6’ Max. 9’ Min.
E) 5’ Max. 5’ Min. 7’ Max. 11’ Min.
length, of all sections, must not exceed 30 feet. Total horizontal sections must not exceed 7 feet.
Minimum of 1 foot between 90° elbows is required.
65June 2007 Regency Product Specifi cations Book
Page 6
43” (1092mm) Minimum Height Requirement
Vertical
Height
(Feet)
Horizontal (Feet)
P48 Gas Fireplace
Venting Arrangements - Horizontal
Terminations
This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45° and one 90° elbow (two 45º elbows equal one 90° elbow).
Gas Fireplaces
Note: Must use optional fl ue adapter (Part # 770-994) when using
Rigid Pipe.
Gas Fireplaces
Maintain clearances to combustibles.
Horizontal vent must be supported every 3 feet.
• Firestops are required at each fl oor level and whenever passing through a wall.
A vent guard should be used whenever the termination is lower than the specifi ed minimum or as per local codes.
Note: FPI Direct Vent System (Flex) is only approved for horizontal
terminations.
16
14
12
10
8
Vertical Height (Feet)
6
4
2
0
Horizontal (Feet)
0
2
43” (1092mm) Minimum Height Requirement
4
6
8
10
12
14
16
18
20
Please refer to Page 11 (Exterior Vent Terminations)
for additional guidelines on vent locations.
66 June 2007 Regency Product Specifi cations Book
Page 7
Gas Fireplaces
Horizontal Venting with Two (2) 90° Elbows - Initial vertical section.
Two 45° elbows = One 90° elbow
P48 Gas Fireplace
Horizontal Venting with Three (3) 90° Elbows - Initial vertical section.
Two 45° elbows = One 90° elbow
Gas Fireplaces
Option V H+ H1 Maximum total pipe: length, of
A) 1’ Min. 3’ Max.
B) 2’ Min. 4’ Max.
C) 3’ Min. 5’ Max.
D) 4’ Min. 6’ Max.
E) 5’ Min. 7’ Max.
F) 6’ Min. 8’ Max.
all sections, must not exceed 30 feet. Total horizontal sections must not exceed 8 feet.
Minimum of 1 foot between 90° elbows is required.
Horizontal Venting with Two (2) 90° Elbows - Initial horizontal section.
Two 45° elbows = One 90° elbow
Option V H V+ V1 H + H1 Maximum total
A) 2’ Min. 1’ Max. 3’ Min. 4’ Max.
B) 3’ Min. 2’ Max. 4’ Min. 5’ Max.
C) 4’ Min. 3’ Max. 6’ Min. 6’ Max.
D) 5’ Min. 4’ Max. 8’ Min. 7’ Max.
E) 6’ Min. 5’ Max. 10’ Min. 8’ Max.
F) 7’ Min. 6’ Max. 12’ Min. 9’ Max.
pipe: length, of all sections, must not exceed 30 feet. Total horizontal sections must not exceed 8 feet.
Minimum of 1 foot between 90° elbows is required.
Option H V H + H1 Maximum total pipe: length, of
A) 1’ Max. 1’ Min. 3’ Max.
B) 2’ Max. 2’ Min. 5’ Max.
C) 3’ Max. 4’ Min. 6’ Max.
D) 4’ Max. 6’ Min. 7’ Max.
E) 5’ Max. 8’ Min. 8’ Max.
all sections, must not exceed 30 feet. Total horizontal sections must not exceed 8 feet.
Minimum of 1 foot between 90° elbows is required.
Horizontal Venting with Three (3) 90° Elbows - Initial horizontal section.
Two 45° elbows = One 90° elbow
Option H V H + H1 + H2 Maximum total pipe:
A) 1’ Max. 1’ Min. 3’ Max.
B) 2’ Max. 3’ Min. 5’ Max.
C) 3’ Max. 5’ Min. 6’ Max.
D) 4’ Max. 7’ Min. 7’ Max.
E) 5’ Max. 9’ Min. 8’ Max.
F) 6’ Max. 11’ Min. 9’ Max.
length, of all sections, must not exceed 30 feet. Total horizontal sections must not exceed 7 feet.
Minimum of 1 foot between 90° elbows is required.
67June 2007 Regency Product Specifi cations Book
Loading...