Regency P40-LP1, P40-NG1 User Manual

Gas Fireplaces
P40 Gas Fireplace
P40 Direct Vent Gas Fireplace
Model P40-NG1 P40-LP1
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5” W.C. (1.25 kPa) 12” W.C. (3.00 kPa)
Manifold Pressure - High 3.5” W.C. (0.87 kPa) 10” W.C. (2.49 kPa)
Manifold Pressure - Low 1.6” W.C. (0.39 kPa) 3.6” W.C. (0.89 kPa)
Orifi ce Size - Front Burner #44 DMS #55 DMS
Orifi ce Size - Rear Burner #35 DMS #53 DMS
Minimum Input 13,000 BTU/h (3.81 kW) 12,000 BTU/h (3.51 kW)
Vent Sizing 5” Inner / 8” Outer 5” Inner / 8” Outer
Approved Venting Systems
Flex Vent Systems: FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems: Simpson Dura-Vent® Direct Vent GS
Selkirk Direct-Temp
B
A
Gas Fireplaces
Unit requires
120V to operate. See
“Wiring Diagram,” on page 17,
for more details. Receptacle is
included with manual.
D
C
A
Unit Dimensions Description P40
A Front Face Width 40” (1016mm)
B Rear Firebox Width 33-7/16” (889mm)
C Front Face Height 34” (864mm)
D Height w/ Standoff 42-1/2” (1080mm)
E Unit Depth 20-1/16” (508mm)
F Height to Vent 35-1/4” (826mm)
Framing Dimensions Description P40
G Framing Width 40-1/2” (1029mm)
*** Framing Height*** 42-1/2” (1080mm)*** + Hearth
H
I Framing Depth 20-1/16” (508mm)
J Corner Wall Length 50-5/8” (1286mm)
K Corner Facing Wall Width 71-5/8” (1524mm)
L Minimum Height to Combustibles 51-7/8” (1318mm)
M Vent Centerline Height 45-3/8” (1153mm)
N Non-Combustible Facing Height 10-1/4” (260mm)
O Gas Connection Height 1-1/2” (38mm)
P Gas Connection Inset 4-3/4” (121mm)
Q Gas Connection Width 3-1/4” (102mm)
E
L
Drywall
(or other
F
Top Header
(non-combustible)
facing)
Top Header (non-combustible)
N
Non-Combustible Facing
H
11" (279mm)
dia. Hole through
wall Vent.
G
I
M
J
O
P
K
Q
Opening for gas
connection
Please refer to Page 11 (Exterior Vent Terminations)
for additional guidelines on vent locations.
Important: Framing height requires consideration of the hearth
***
depth. Dimension H = H + the thickness of installed hearth.
45June 2007 Regency Product Specifi cations Book
P40 Gas Fireplace
Framing and Finishing
1) Frame the enclosure for the unit with framing material. Use the determined total thickness of facing material (e.g. drywall plus ceramic tiles) to adjust the framing depth to allow the fi nished surface to be fl ush with the front of the unit. Total facing thickness
Gas Fireplaces
can vary from 1/2” (13mm) to 1-1/4” (32mm) thick.
Note: Header for the P40 must be non combustible.
2) For exterior walls, insulate the enclosure to the same degree as
the rest of the house, apply vapor barrier and drywall, as per local installation codes. (Do not insulate the fi replace itself.)
3) Ensure that all of the clearances listed below are met. Combustible material may be brought up to the sides of the unit and be covered with ceramic tiles, bricks, rock or other suitable combustible fi nishing materials. Non-combustible facing is required above
the unit. (See Dimension “N” on page 41)
Note: You must maintain proper clearances from the vent to
combustible materials (See Below).
4) Use metal studs for framing where the minimum clearance from
the vent to combustible material cannot be maintained.
Clearance Requirements
Required hearth must be non-combustible. (Page 43)
Required non-combustible facing above unit. (See Dimension “N” on page 41)
Gas Fireplaces
Vent Clearances Clearance Dimension
Horizontal - Top 2-1/2” (64mm)
Horizontal - Side 1-1/2” (38mm)
Horizontal - Bottom 1-1/2” (38mm)
Vertical (Flex or Rigid) 1-1/4” (32mm)
WARNING
Failure to maintain required clearances is a major cause of chimney related fi res. Installation of this fi replace must comply with these clearances.
Hearth Requirements
A 40" (1016mm) wide x 16" (406mm) deep x 1-1/2" (38mm) thick hearth is required, unless the unit is raised 4" (102mm). All measurements are from the bottom of the unit. Therefor the bottom of the unit would be fl ush with the top of a non-combustible hearth or 4” above the surface of a combustible fl oor.
Floor Mounted Fireplace
D
C
A
F
B
B
H
I
G
E
Clearance: Dimension Measured From:
A: Mantel Height 12” (305mm) Minimum (Additional on this page)
B: Sidewall 8” (203mm) Side of installed front
C: Ceiling 39” (991mm) Top of installed unit
D: Mantel Depth 13” (330mm) Maximum (Additional on this page)
E: Alcove Width 56” (1422mm) Sidewall to Sidewall (Minimum)
F: Alcove Depth 36” (914mm) Front to back wall (Maximum)
G: Hearth Height 1-1/2” (39mm) Floor to top of Hearth.
H: Hearth Width 40” (1016mm) Edge to Edge of Hearth
I: Hearth Depth 16” (406mm) Front of Hearth to Wall
not be higher than base of fi rebox.)
(Hearth must
Raised Fireplace
Full Screen Door Facing Requirements
WARNING: When installing the
10-1/4” Above Fireplace
6”
6”
Full Screen Doors
The Full Screen Front requires additional non combustible facing and non-combustible framing. Ensure the 10-1/4" above the fi replace, 6" on both sides and both the header and side studs are non-combustible materials. All other clearances, including mantel, remain the same.
46 June 2007 Regency Product Specifi cations Book
Gas Fireplaces
Combustible Mantels
Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of
the louvers are shown in the diagram below. Mantel may be installed anywhere in the shaded area or higher.
Mantel Clearances
12
14
64810
13" (330mm)
8”(203mm)
1" (25mm)
B
C
2
D
0
Drywall
Non-Combustible
Header
Non-Combustible
Standoff
Facing
P40 Gas Fireplace
FPI Kit # Length Contains:
#946-618 6 Feet 1) 8” fl exible outer liner (Kit length)
2) 5” fl exible inner liner (Kit length)
3) spring spacers (3)
4) thimble (2)
5) AstroCap termination cap (1)
#946-616 10 Feet
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) S.S. screws #8 x 1-1/2” drill point, (4)
10) vinyl siding standoff
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency may be used for Flex installations.
3) Horizontal sections must be supported every 3 feet.
AstroCap XL
(Part# 946-623/P)
Gas Fireplaces
0
Mantel Clearances
Front 33” (838mm) 21” (356mm) 17” (254mm) 12” (178mm)
To p o f
A
Louvers
To Floor
ABCD
Side View
Note: If desired a non-combustible mantel may be installed at a
lower height.
Note: Ensure the paint that is used on the mantel and the facing
is “heat resistant” or the paint may discolour.
Mantel Leg Clearances
Combustible mantel leg clearances as per diagram below: Clearances are from the fi nished edge of the unit or installed front.
8” Side Wall
P40
Mantel leg
6”
Maximum 1-1/2” projection at 2” minimum clearance.
Mantel leg
1-1/2"
2"
7¼”
Allowable mantel leg
projection.
Wall Thimble
(required in Canada only)
5” dia. flue pipe
8" dia.
Flue pipe
spring spacer
Vinyl Siding
Standoff
Snorkel Terminations
Snorkel Terminations:
For installations requiring a vertical rise on the exterior of the building, 14­inch and 36-inch tall Snorkel Terminations are available. Follow the same installation procedures as used for standard Horizontal Termination. NEVER install the snorkel upside down.
Regency Direct Vent System (Flex)
Horizontal Terminations Only
These venting systems, in combination with the P40 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram.
FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the P40 using a fl exible vent.
Below Grade Snorkel Installation (Dura-Vent Only)
If the Snorkel Termination must be installed below grade, i.e. basement application, proper drainage must be provided to prevent water from entering the Snorkel Termination. Refer to Rigid Pipe Installation instructions for details. Do not attempt to enclose the Snorkel within the wall, or any other type of enclosure.
47June 2007 Regency Product Specifi cations Book