b e e n h i g h e r . Tu r n y o u r f u r n a c e w a y d o w n
and zone heat with beautiful, renewable
wood in the rooms you spend time in.
Not only can you cut your fuel bills in half
but you will be able to enjoy the timeless
joy of a wood re. The glowing embers,
the sna p of woo d a s i t c at ch es r e, th e c a -
s ua l c u rl o f y el l ow a m es , th er e is not h in g
li ke a wo od re .
the wood so that it burns completely,
resulting in very little ash and almost no
polluting smoke into our environment.
Burning wood is also carbon neutral.
Regency Quality
The Regency name means quality in ev-
ery way. I am supported by an excep-
tional team, state of the art research and
a world class manufacturing facility. We
have carefully selected a dealer network
th at is comm it ted to your satis fa ct ion.
Lifetime Warranty
I am so condent in the quality work-
manship, the nest materials, and du-
rable heavy-duty construction invested
in each and every product, that I oer a
Limited Lifetime Warranty. We know that
you will be as proud of your Regency
Wood Stove, Fireplace or Insert as we are
– I guarantee it.
2
Environmentally Friendly
All Regency Wood Stoves, Fireplaces and
Inserts have been certied by the
Environmental Protection Agency (EPA).
Regency engineers have carefully de-
signed the rebox to create airow around
Robert Little
Fo un de r & CEO
Page 3
index
Regency Classic Wood Stoves
F1100, F2400, F3100 6
S2400 8
Rgency Wood Fireplaces
R90 & EX90 10
Regency Classic Wood Inserts
I1200 12
I24 00 & I310 0 14
Hearth Heater 16
Design Choices 18
Technical specs 20
3
Page 4
renewableaordablebeautiful
4
Page 5
burning wood - a green choice
Wood is aordable
Reduce your dependence on high priced, non-renewable
home heating fuels by burning wood. Turn your furnace
down and enjoy comforting warmth in your main living area
with a Regency wood product. Whether you buy your wood
or collect it yourself, you will notice the savings within its rst
year.
Renewable Resource
Wood is a renewable natural resource - well-managed forests
are a renewable, sustainable source of energy that helps us
reduce greenhouse gas emissions and be less dependent on
oil & gas .
Wood is Carbon Neutral
As trees grow they absorb carbon dioxide from the atmosphere. When trees die and are left to decompose in the forest or burn in forest res the carbon stored in the trees is released in the atmosphere as carbon dioxide.
Burning rewood produces the same amount of carbon dioxide as it has absorbed during its life cycle - making wood
burning carbon neutral.
All Regency Wood Stoves, Fireplaces and Inserts have been
tested and certied to the strictest clean air standards as set
by the Environmental Protection Agency.
One Regency = One Tree
At Regency, we are committed to protecting our environment. For every Regency sold, we will plant a tree. Working
with American Forests, the trees planted across North America
will oset carbon emissions and take one more step to restore
nature's balance.
5
Page 6
Classic Wood Stove
F1100, F2400, F3100
6
F2400 wit h black legs, go ld accent door, convec tor airmate and b ottom heat shield .
The timeless styling of the Classic Wood Stove comes in three sizes
producing from 55,000 to 80,000 BTU of toasty warmth for a single
living area or an entire home. Up to 77% eciency means any room
can be heated quickly. It also means your wood stove burns cleanly meeting the strictest air quality standards set by DEQ Washington
Phase II Clean Air Standard of 4.5 grams/hr. or less.
Page 7
F2400 wit h black door and pedestal.
F2400 wit h gold door, gold le gs, convector ai rmate and bott om heat shield.
F2400 wit h black door, brush ed nickel legs, co nvector airmate, bottom heat shi eld,
nickel hing e caps and handle s.
Standard FeaturesOptional Features
EPA Certified w
Mobile home and alcove approved w
Closest clearances in the industry w
Single rod draft control w
Brick-lined firebox w
Airwash system w
Rear heat deflector w
Cast iron door in gold, black**, gold accent or w
nickel accent
Nickel hinge caps and handle (for black door w
upgrade)
Cast iron legs in gold, black or brushed nickel w
Pedestal base w
Bottom heat shield (when using legs) w
Ash drawer w
2-speed blower w
Convector airmate w
Outside air kit w
Screen door w
Specifications
F110 0F24 00F310 0
Maximum BTU*55,00 075,00 080,00 0
Typical Sq. Ft. Heated60 0 -12 001000-22002000-3500
Optimum Efficiency73.8%77%71%
Maximum Log Size18"18 "2 1"
Burn Time (Typical)*up to 8 hrsup to 8 hrsup to 10 hrs
Emissions (grams/hr)3.0 g3.4 g4.2g
Firebox Size1.4 cu. ft.2.3 cu. f t.2.9 cu. f t.
Flue Size6"6"6"
* Length of burn time and BTU range depend on type of wood, mois-
ture content, climate conditions and installation.
** Black doors come with gold handles & gold hinge caps
For detailed specications please see pages 18-23.
7
Page 8
Classic S2400
Step Top Wood Stove
8
S2400 shown with gold door and pedestal base.
The special design of the Step Top Classic makes it possible for it to
be placed close to a corner of the wall. This makes it ideal for a small
room or for installation in tight alcoves. All Regency wood products
come with an optional two speed blower to help deliver high eci ency hea t to the far reach es of yo ur home .
Page 9
S2400 wit h black door and p edestal bas e.S2400 wit h gold accent door and pedestal base.
S2400 wit h nickel accent door and pedestal base.
Standard FeaturesOptional Features
EPA Certified w
Mobile home and alcove approved w
Lowest clearances in the industry w
Single rod draft control w
Brick-lined firebox w
Airwash system w
Cast iron door in gold, black**, gold accent or w
nickel accent
Nickel hinge caps and handle (for black door w
upgrade)
Cast iron legs in gold, brushed nickel or black w
Pedestal base w
Ash drawer w
Bottom heat shield (when using legs) w
2-speed blower w
Outside air kit w
Screen door w
Specifications
S240 0
Maximum BTU*75,00 0
Typical Sq. Ft. Heated1000-2200
Optimum Efficiency77%
Maximum Log Size18"
Burn Time (Typical)*up to 8 hrs
Emissions (grams/hr)3.4g
Firebox Size2.3 cu. f t.
Flue Size6"
* Length of burn time and BTU range depend on
type of wood, moisture content, climate conditions and ins tallation.
** Black doors come with gold handles & gold hinge
caps
9
Page 10
R90 & EX90
Wood Fireplaces
10
R90 feat uring black louv ers.
Regency’s high eciency replaces put a designer face on a hard
working heater. Just load up your Regency and tuck in for a cozy
night’s sleep. Delivering up to 70,000 BTU of high eciency heat,
your Regency will burn for up to 8 hours while your rest. Choose a traditional design (R90) or an arched Excalibur front (EX90) with tasteful
accessory options to create the perfect furnace with a view!
Page 11
EX90 sh own with Exc alibur front i n antique nickel.
R90 feat uring black wit h steel louver s.R90 feat uring black louv ers and gravit y air kit.EX90 sh own with Exc alibur front in bl ack.
Standard FeaturesOptional Features
EPA Certified w
Single rod draft control w
Airwash system w
Black cast iron double doors w
Ceramic safety glass w
Brick-lined firebox w
Andirons w
Outside air kit w
Black/gold, black/brushed steel or black lou- w
vers (R90)
Excalibur front in black or antique nickel w
Blower w
Ash drawer w
Finishing trim (R90) w
Gravity air kit w
Masonry retainer kit (R90) w
8" - 7" flue adaptor w
(Canada only)
8" Air cooled chimney adaptors (US only) w
Screen door w
Specifications
R90EX90
Maximum BTU*70,00 070,00 0
Typical Sq. Ft. Heated1,000-2,2001,000-2,200
Optimum Efficiency74%74%
Maximum Log Size20"20"
Burn Time (Typical)*up to 8 hrs.up to 8 hrs.
Emissions (grams/hr)3.72g3.72g
Firebox Size2.5 cu. f t.2.5 cu. f t.
Flue Size8"8"
* Length of burn time and BTU range depend on t ype of wood, moisture
content, climate conditions and installation.
11
Page 12
Classic I1200
Small Wood Insert
12
Regenc y I12 00, with nickel acc ent door, regular face plate and blower.
For that drafty replace that isn’t quite big enough for a standard
insert, or for that area in your house that invites a compact style of
replace, look to the Regency Classic Small Insert. With all the high
eciency, clean burning, quality features of all Regency wood products, th is i nser t a dapt s to t m ost pre fab replaces.
Page 13
I1200 with go ld accent door, regular f aceplate and blower.
I1200 with bla ck door, regular face plate and blower.I1200 with go ld door, regular facep late and blower.
Standard FeaturesOptional Features
EPA Certified w
Single rod draft control w
Airwash system w
Brick-lined firebox w
Cast iron door in gold, black**, gold accent w
or nickel accent
Nickel hinge caps and handle (for black door w
upgrade)
Regular or oversize faceplate (black trim w
included)
2-speed blower w
Screen door w
Brass faceplate trim w
Regency stainless steel flex liner kit w
Bottom 1 piece faceplate & fan support w
Standard or 4-1/2" offset flue adaptor w
Specifications
I120 0
Maximum BTU*55,00 0
Typical Sq. Ft. Heated600-1000
Optimum Efficiency73.8%
Maximum Log Size18 "
Burn Time (Typical)*up to 8 hrs.
Emissions (grams/hr)3.0g
Firebox Size1.4 cu. ft .
Flue Size6"
Minimum Fireplace Opening
Width23"
Height19"
Depth (with standard adaptor)13-3/4"
* Length of burn time and BTU range depend on type of
wood, moisture content, climate conditions and installation.
** Black doors come with gold handles & gold hinge caps
13
Page 14
Classic I2400 & I3100
Medium & Large Wood Insert
14
Regenc y I2400 with nicke l accent door, nickel conv ection grills, regular faceplate and blower.
Your open masonry replace can allow as much as 90% of your
re’s heat to escape out the chimney. By adding a Regency Classic
Fireplace Insert, you will keep the heat in your home. Regency Inserts
are ready to install and t easily into your existing replace. Increase
the value of your home and decrease your monthly heating bill.
Page 15
I2400 wit h black door, gold co nvection grills, brass faceplate trim and blower.
I2400 wit h gold accent door, go ld convection g rills, brass face plate trim and blo wer.
I2400 wit h gold door, gold conv ection grills, regular faceplate, brass faceplate t rim
and blower.
Standard FeaturesOptional Features
EPA Certified w
Single rod draft control w
Airwash system w
Brick-lined fire box w
Black convection grills w
Mobile home approved (I2400 only) w
Cast iron door in gold, black**, gold accent or w
nickel accent
Nickel hinge caps and handle (for black door w
upgrade)
Gold or nickel convection grills w
Regular or oversize faceplate (black trim w
included)
Screen door w
Brass faceplate trim w
Regency stainless steel flex liner kit w
2-speed blower w
Specifications
I240 0I 3100
Maximum BTU*75,00 080, 000
Typical Sq. Ft. Heated1000-20001800-3000
Optimum Efficiency77%71%
Maximum Log Size18"21"
Burn Time (Typical)*up to 8 hrsup to 10 hrs
Emissions (grams/hr)3.4g4.2g
Firebox Size2.3 cu. ft.2.9 cu. f t.
Flue Size6"6"
Minimum Fireplace Opening
Width25"28"
Height21-1 /2 "25"
Depth17 "17 "
* Length of burn time and BTU range depend on type of wood, mois-
ture content, climate conditions and installation.
** Black doors come with gold handles & gold hinge caps
15
Page 16
Classic Hearth Heater
HI2100 Wood Insert
16
Hearth Heater H2100, with blac k door, regular face plate and two spe ed blower.
The Hearth Heater combines the best qualities of the Classic Stove
and Insert series. It eliminates the cold draft of an open replace and,
because it sits out on the hearth, gives you both convective and radiant heat. Build a custom look for your Regency with leg and door options. Like all Regency products, the Hearth Heater operates during
power outages, providing a convenient cooktop surface as well.
Page 17
H2100 with re gular faceplate, nic kel accent door and blower.
H2100 with re gular faceplate, go ld accent door and blower.H2100 with g old door, regular fa ceplate, brass face plate trim and bl ower.
Standard FeaturesOptional Features
EPA Certified w
Single rod draft control w
Airwash system w
Brick-lined firebox w
Convector airmate (built-in) w
Cast iron door in gold, black**, gold accent or w
nickel accent
Nickel hinge caps and handle (for black door w
upgrade)
Cast iron legs in gold, black or brushed nickel w
(see diagram on p.22)
Regular or oversize faceplate (black trim w
included)
Brass faceplate trim w
Regency stainless steel flex liner kit w
2-speed blower w
Specifications
H2100
Maximum BTU*70,000
Typical Sq. Ft. Heated80 0 -150 0
Optimum Efficiency72%
Maximum Log Size18"
Burn Time (Typical)*up to 8 hrs
Emissions (grams/hr)3.5g
Firebox Size1.6 cu. ft.
Flue Size6"
Minimum Fireplace Opening
Width8"
Height20"
Depth-
* Length of burn time and BTU range depend on type of wood,
moisture content, climate conditions and installation
** Black doors come with gold handles & gold hinge caps
17
Page 18
Inside your Regency Wood Stove
Non-catalytic Technology
Regency uses non-catalytic technology which
means that the airflow in the firebox is directed
in such a way that smoke is reburned. This creates greater efficiency, a spectacular fire and
results in cleaner emissions.
By combining non-catalytic technology with
durable construction, Regency builds wood
fireplaces that are guaranteed to last. These
stove and insert diagrams illustrate the airflow
and durable components that make Regency
your heating solution.
Convector Airmate
Directs convection heat
into your room. Allows
closer clearances.
Heat Reflective Baffle
Designed to reflect heat
back into the firebox to
enhance reburn. Improves
temperature distribution and
efficiency of the firebox.
Exhaust
Limited Lifetime Warranty
All Regency products are warrantied
for a lifetime of great looks, ease of
use and superb performance. Ask
your Regency dealer for details.
Heavy Gauge Steel
Used throughout the stove to ensure
long term durability and increase radiant heat.
Stainless Steel Air Tubes
Injects secondary air into firebox
to create reburn. Provides cleaner,
more complete combustion.
Heavy Duty Hinge Pins
To ensure long term durability.
18
Firebox
Airtight and lined with firebrick
to ensure wood is burned
completely to deliver clean
efficient heat.
Side Shields
Insulates stove to prevent heat
loss and allows convective air to
be warmed against side of stove.
Single Rod Draft Control
Simple and easy to control
heat output and size of fire.
Removable Ash Drawer
For safe and easy clean up.
Fits seamlessly into design
of stove.
Airwash System
Engineered to keep your glass clean
automatically by creating airflow across
inside of glass. Stove must burn at
maximum for 30 minutes for Airwash to
occur.
Ceramic Safety Glass
Tested and certified to withstand very
high temperatures. Allows heat to
radiate through the glass.
Heavy Duty Cam Latch
Ensures airtight seal for controlled
airflow.
Page 19
Options
Convenient Ash Removal System
1. Open door
2. Pull out drawer3. Slide cover on top4. Carr y awa yLe g A sh Draw er
Base Options
24 Karat Gold Plate d Cast Iron LegsB rushed Nickel Cast Iron LegsBlack Cast Iron LegsBlack Pedestal
Cast Iron Doors
Black Cast Iron DoorGold Cast Iron DoorGold Accent Cast Iron D oorNickel Accent Cast Iron Door
Screen Doors
A compact ash drawer
system is also featured
on the leg version.
For wood s toves and inserts.For R90 & EX90 wood f ireplaces
Convector Airmate
The convector airmate scoops super heated air
from the back and top of the stove and directs it
to the living area in front. This heat dispersion reduces temperatures behind the unit and allows it
to be inst al le d eve n c los er to th e w all.
Powerful Blower
The blower can dramatically increase the circulation
of heat in your home. It includes dual speed settings and an automatic heat sensor which turns
the blower on and o at predetermined temperatures.
19
Page 20
A
F
F
C
C
B
E
6"
6"
6"
6"
16"
16"
D
G
K
H
J
I
B
E
B
A
B
E
B
A
D
C
B
E
Specications - Wood Stoves
FRONT WITH
PEDESTAL
TOP
FRONT WITH LEGS
Minimum Clearance to Combustible Materials
Please read the section below carefully as clearances depend on
whether the optional airmate convector or the rear heat deflector
is installed on the stove. Measurements “From Unit” are from the
top plate of the stove to a side wall or to a corner, and from the
rear heat shield to a back wall.
DimensionsA**BC***DE* *
Sm al l F110 0
Medium F2400
Large F3100
Med ium S 2400
** M easured t o top of fl ue collar fo r height
*** Including Ash Lip
Classic St oves
Maximum BTU*
Typical Sq . Ft. Heate d
Optimum Efficienc y
Maximum Log Size
Burn Time (Typical)*
Emissions (grams/hr)
Firebox Size
Flue Size
* Le ngth of bu rn time an d BTU range depend on t ype of wo od, climat e conditio ns and ins tallation .
Resident ial Installatio n “C” Vent (Single Wall)
Sm al l F110 0
Med ium S 2400
Medium F2400
Large F3100
with Air Mate13"11"8"25"17. 5"20"
with Rea r Deflec tor15"10.5"11"27"17"23"
with Step Top16"11"6"28"17. 5"17. 5 "
with Air Mate16"11"6"28"17. 5"17. 5 "
with Rea r Deflec tor18"12"6.5"30"18 .5"19.5"
with Air Mate18"12"8.5"32"18. 5"2 2"
with Rea r Deflec tor20"14"10.5 "34"20.5"24"
30 -1/4 "24"20"6"31-3/4"
32-1/ 16"24"27-3/8"6"33-1 /2"
33-5/16"28"25-1/4 "6"34 -3/4"
34-3/ 8"24"27-3/8"6"35- 7/8 "
Flat TopStep Top
F110 0F24 00F310 0S2400
Small Stov eMedium StoveLarge StoveMe dium Stove
55,00075,00080,00075,000
60 0 -120 01000-22002000-35001000-2200
73.8%77%71%77%
18"18"21"18 "
up to 8 hr sup to 8 hr sup to 10 hr sup to 8 h rs
3.0g3.4g4.2g3.4g
1.4 cu. ft .2.3 c u. ft.2.9 cu. ft.2.3 cu. f t.
6"6"6"6"
FROM UNITFR OM CORNERFROM FLUE CE NTER-LINE
ABCDEF
These c learances are cer tified cleara nces for the s tove, however, the cleara nce to the combus tibles and the s ingle wall stove pip e must also be
maintaine d. You can reduce the stove pipe cleara nce with a stove p ipe heat shield.
20
Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is
required from the stove collar to the ceiling level.
Resident ial Close Clear ance
(To be ins talled wit h required pipe compon ents)ABCDEF
Sm al l F110 0
Med ium S 2400
Medium F2400
Large F3100
with Air Mate9"5"3"21"11.5"15"
with Rea r Deflec tor13 .5"5"5"25. 5"11.5"17"
with Step Top15"5.5"4"27"12"15 .5"
with Air Mate15"5.5"4"27"12"15. 5
with Rea r Deflec tor15"6. 5"6"27"13"17.5 "
with Air Mate16"9.5"8.5"30"16"22"
with Rea r Deflec tor20"12"8.5"34"18.5"22"
FROM UNITFR OM CORNERFROM FLUE CE NTER-LINE
Minimum Alcove Clearance to Combustible Materials
The Regency® Freestanding models have been alcove approved and must be installed with a
listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 84 in. / Maximum depth of alcove - 36 in.
Minimum A lcove Clearance
Sm al l F110 0
Med ium S 2400
Medium F2400
Large F3100
with Air Mate11"7"23"13.5"4 6"
with Rea r Deflec tor13"5"25"11.5"50"
with Step Top15"5.5"27"12 "54"
with Air Mate15"5.5"27"12"54"
with Rea r Deflec tor15"6. 5"27"13"54"
with Air Mate16"9.5"30"16"60"
with Rea r Deflec tornot appr oved for Alcov e
FROM UNITFROM FLUE C ENTER-LINEMIN. WIDT H
GHIJK
Mobile Home Close Clearance (To be installed with required pipe components)
“C” Vent single wall pipe is not approved for mobile home installations. (Refer to mobile home instructions)
Mobile H ome Close C learanceFROM UNITFROM CORNERFROM FLUE CENTER-LI NE
(To be ins talled wit h required pipe compon ents)ABCDEF
Sm al l F110 0
Med ium S 2400
Medium F2400
Large F3100
with Air Mate11"6"6"23"12.5"18"
with Rea r Deflec tor13"5"9"25"11 .5"21"
with Step Top15"5.5"4"27"12"15 .5"
with Air Mate15"5.5"4"27"12"15.5"
with Rea r Deflec tor15"6. 5"6"27"13"17.5 "
with Air Mate18"9.5"10 "32"16"23.5"
with Rea r Deflec tor20"12"10"34"18.5"23.5"
Page 21
CLASSIC WOOD STOVE FLOOR PROTECTION
D
A
B
C
D
A
A
B
B
C
D
A
A
6"
B
B
C
6"
USA FLOOR PROTECTION
Flush Wall Hearth Re quirement s
Sm al l F110 0
Med ium S 2400
Medium F2400
Large F3100
CANADA FLO OR PROTECTI ON
Flush Wall Hearth Re quirement s
Sm al l F110 0
Med ium S 2400
Medium F2400
Large F3100
USA FLOOR PROTECTION
Corner H earth Req uirements
Sm al l F110 0
Med ium S 2400
Med ium F 240 0
Large F3100
with Air Mate36"38"36"37 "36"38"36"38"
with Rea r Deflec tor3 6"38"36"37"36"37 "36"37 "
with Step Top36"4 6"36"45"36"45"36"45"
with Air Mate36"46"36"45"36"45"36"45"
with Rea r Deflec tor3 6"46"3 6"45"36"45"36"45"
with Air Mate40"43"4 0"43"40"43"40"43"
with Rea r Deflec tor40"43"40"43"40"43"Not approved
with Air Mate40"42"4 0"41"4 0"42"40"42"
with Rea r Deflec tor40"42"4 0"41"40"41"40"41"
with Step Top40"50"40"49"40"49"40"49"
with Air Mate40"50"40"49 "40"49"40"49"
with Rea r Deflec tor40"50"40"49 "4 0"49"40"49 "
with Air Mate44"47"44"47 "4 4"47"4 4"47 "
with Rea r Deflec tor4 4"47 "44"47"44"4 4"N ot approved f or alcove
with Air Mate3 6"52.75" 45.75" 21.25"36"47.75" 40.75" 16.25"36"50.75" 43.75" 19.25 "
with Rea r Deflec tor36"57. 2 5 " 49.2 5"25"36"49.75 " 42.75" 18.2 5"36"58.25" 50.25"26"
with Step Top36"57. 5 "53.5"26. 5"36"55"52.5"24.75"36"55"52.25" 24.75"
with Air Mate3 6"57. 5 "53.5"26.5"36"55"52.5"24.75"36"55"52.25" 24.75"
with Rea r Deflec tor36"58"54"27"36"5 7. 5 "53.5"27"36"5 7. 5 "53.5"27"
with Air Mate40"60. 75"53"24.25"40"60.75"53"24. 25"40"60.25" 54.5" 24.2 5"
with Rea r Deflec tor40"63.5"53.5 " 26.25"40"60.75"53"24.2 5"40"63"54.5" 24.2 5"
Residen tial “C” VentRe sidential C lose Cleara nce
ABABABAB
Residen tial “C” VentRe sidential C lose Cleara nce
ABABABAB
Residen tial “C” VentResident ial Close Cl earance
ABCDABCDABCD
Mobile H ome
Close C learance
Mobile H ome
Close C learance
Alcove
for alcov e
Alcove
Mobile H ome
Close C learance
Corner Installations
If the rear clearance to combustibles is less
than 6", for corner installations the corners
may be angled to take advantage of the closer
clearances.
CANADA FLO OR PROTECTI ON
Corner H earth Req uirements
Sm al l F110 0
Med ium S 2400
Med ium F 240 0
Large F3100
Residen tial “C” VentResident ial Close Cl earance
ABCDABCDABCD
with Air Mate40"54.75 " 47.75" 19.25"4 0"49.75" 42.75" 14. 25"40"52.75" 45.75" 17. 2 5 "
with Rea r Deflec tor4 0"59. 25" 51.2 5"23"40"51.75" 4 4.75" 16.25"40"60.25" 52.25"24"
with Step Top40"5 9.5"55.5"28. 5"4 0"57"54.5" 26.75"40"57"54.25" 26.75"
with Air Mate40"5 9.5"55.5"28. 5"4 0"57"54.5" 26.75"40"57"54.25" 26.75"
with Rea r Deflec tor4 0"60"56"29"40"59.5 "55. 5"29"4 0"5 9.5"55.5"29"
with Air Mate4 4"62.75"55 "22.25"44"62.75"55"2 2.25"44"62 .25" 56.5" 22. 25"
with Rea r Deflec tor4 4"65.5"55. 5" 24.2 5"44"62.75"55"22.25"44"65"56.5" 22. 25"
Mobile H ome
Close C learance
Floor Protection
A combustible floor must be protected by non-combustible material (like tile, concrete board, or certified to UL-1618
or as defined by local codes) extending beneath the heater and a minimum of 6" (USA) or 8" (250mm) (Canada) from
each side and minimum 16" (USA) or 18" (450mm) (Canada) from the front face of stove and minimum 6" (USA) or 8"
(250mm) (Canada) or the rear clearance to combustibles, whichever is smaller, from the rear of the stove.
When installed with horizontal venting, non-combustible floor protection must be installed beneath the flue pipe and
extend 2" (51mm) beyond each side.
Depth (w/ standard flue adaptor)
(w/ offset flue adaptor)
Masonry & Factory Built Fireplace Clearances
The minimum required clearances to combustible materials when installed into a masonry replace are:
Small I1200
Med ium I 240 0
Larg e I310 0
Heart h Heater H2100
*Note: If the hearth ex tension is flush with the f loor (item F) it must extend 19.5 in. in front of the body face (item E) (I1100, I3100 & H2100 only).
**Note: H earth exten sion width (G) is me asured from ed ge of fuel doo r to side of hear th.
Regular Face plate (W x H)
Oversi ze Faceplate (W x H)
* including ashlip
Maximum BTU*
Typical Sq . Ft. Heate d
Optimum Efficienc y
Maximum Log Size
Burn Time (Typical)*
Emissions (grams/hour)
Firebox Size
Flue Size
* Length of burn time and BTU range depend on type of wood, moisture content, climate conditions and installation.
I1200I240 0I3100H210 0
Small Ins ertMedium InsertL arge Inser tMedium Insert
38" x 26-1/8"4 0" x 30"44" x 32"40-1/4" x 30"
44" x 30 -1/8"48 " x 33"50" x 34 -1/2"48" x 33"
I1200I240 0I3100H210 0
Small Ins ertMedium InsertL arge Inser tMedium Insert
55,00075,00080,00070,000
600-10001000-20001800-300080 0 -150 0
73.8%77%71%72%
18"18"21"18"
up to 8 hr sup to 8 hrsup to 10 hr sup to 8 hr s
3.0g3.4g4.2g3.5g
1.4 cu. ft .2.3 cu. ft.2.9 cu. ft.1.6 cu. f t.
6"6"6"6"
I3100 TOP
H2100 TOP
Hearth Heater Minimum Fireplace Openings
28" (with l egs)
Illustrates Hearth Heater with classic leg option.
Page 23
C
center lin e
D
E
A
B
38"
43-5/8"
14-5/8"
13-3/8"
28"
9-5/8"
25"
15"
4-3/4"
50-1/2"
42-5/8"
3-5/8"
1-3/8"
7-7/8"
29-1/8"
31"
37-3/8"
E
D
C
B
A
F
F
J
G
G
H
I
K
L
Specications - Wood Fireplaces
38"
43-5/8"
14-5/8"
13-3/8"
28"
9-5/8"
25"
15"
4-3/4"
50-1/2"
42-5/8"
29-1/8"
43"
38-3/4"
C
center lin e
D
E
A
B
UNIT DIMENSIONS
SPECIFICATIONSR90 WarmHearth PlusExcalibur EX90
Maximum BTU*70,00070,000
Typical Sq. Ft. Heated1,000-2,2001,000-2,200
Efficiency (EPA)74 %74%
Maximum Log Size20"20"
Burn Time (Typical)*up to 8 hrsup to 8 hrs
Emissions (grams/hr)3.72g3.72g
Firebox Size2.5 cu. f t.2.5 cu. ft.
Flue Size8"8"
* Length of burn time and BTU range depend on type of wood, moisture content,
climate conditions and installation
FRAMING
FramingUSACanada
A9 6 -1/4"115-3 /8 "
B4 8 -1/ 8"5 7-5/8"
C68"81 -1/2 "
D24 -1/ 2 "3 1-1/4 "
CLEARANCE TO COMBUSTIBLES
E3"9 -3/4"
F22"30"
G13 -3/4"13 -3/4"
H28"28"
I14-5/ 8"14-5/8"
J0"11"
K44"44"
L50 -3/4"5 0-3/4
US only: Chase must be ventilated
with one 30 square inch vent grill. The
vent grill must draw air from inside the
home and not from outside.
Minimum Clearance to Combustibles
ASide Wall From Louver O pening (EX90: to surround edge)18"24"18"24"
BMantel Height (min.) From Louver Opening18"18"18 "18 "
CMantel Depth (max.)10"10"10 "10"
Non-Combustible Hearth Requirement
DHearth Width40"40"40"40"
EHearth Depth18"18"18"18"
R90E X90
USACanadaUS ACanada
NOTE: All product specications are subject to change
without notice. Before installing refer to the relevant
product manual for full and up to date information.
23
Page 24
We want you to enjoy your beautiful Regency replace for years to come. To help you gure out which product is just right for your home, ll inthe following worksheet. Once complete, visit your nearest Regency dealer. Your professional Regency dealer will assess your needs - includinglocal building codes - and install your Regency.
replace selection worksheet
Mantel dept
h
H
ea
rth t
o
m
a
nt
e
l
enin
g
hei
g
ht
Drop in fireplac
e
thickn
ess
Depth in firepla
c
e
ack hei
g
ht
XX%
Cert no. XXX-XXX-000
designyour own
replace
Your Regency® matches your home and lifestyle perfectly. How do we know that? Because you designed it
yourself!
Visit www.regency-re.com today and surf through our
selection of products and accessories to design your
own replace. The endless options are just a click away!
Change the style until you have your perfect replace...
then ask your friends and family for their opinion!
Click on Fireplace Design Centre at www.regency-re.com
and then visit your authorized local dealer to design
your own replace.
1. BASIC PRODUCT FUNCTION QUESTIONS
a. I would like my inbuilt to provide me with:
Supplemental heating Priority heating
b. The room/rooms I would like to heat are: Square feet
2. FIREPLACE PRODUCT TYPE AND MEASUREMENTS
a. I am:
Installing a new fireplace
Installing into an existing fireplace
b. Fill in the following measurements:Ceiling Height: